Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Cryogenic Optical Performance of the Cassini Composite Infrared Spectrometer (CIRS) Flight Telescope

The CIRS half-meter diameter beryllium flight telescope's optical performance was tested at the instrument operating temperature of 170 Kelvin. The telescope components were designed at Goddard Space Flight Center (GSFC) but fabricated out of house and then assembled, aligned and tested upon receipt at GSFC. A 24 inch aperture cryogenic test facility utilizing a 1024 x 1024 CCD array was developed at GSFC specifically for this test. The telescope's image quality (measured as encircled energy), boresight stability and focus stability were measured. The gold coated beryllium design exceeded the image performance requirement of 80% encircled energy within a 432 microns diameter circle.

Losch, Patricia↗

Image Sensors Enhance Camera Technologies

In the 1990s, a Jet Propulsion Laboratory team led by Eric Fossum researched ways of improving complementary metal-oxide semiconductor (CMOS) image sensors in order to miniaturize cameras on spacecraft while maintaining scientific image quality. Fossum s team founded a company to commercialize the resulting CMOS active pixel sensor. Now called the Aptina Imaging Corporation, based in San Jose, California, the company has shipped over 1 billion sensors for use in applications such as digital cameras, camera phones, Web cameras, and automotive cameras. Today, one of every three cell phone cameras on the planet feature Aptina s sensor technology.

Source record↗

RTN-095: The Vera C. Rubin Observatory Data Preview 1

We present Rubin Data Preview 1 (DP1), the first release of data from the NSF-DOE Vera C. Rubin Observatory, consisting of raw and calibrated single-epoch images, coadds, difference images, detection catalogs, and other derived data products. DP1 is based on 1792 science-grade optical/near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera, LSSTComCam, on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile during the first on-sky commissioning campaign in late 2024. DP1 covers a total of ~15 sq. deg. over seven roughly equally-sized non-contiguous fields, each independently observed in six broad photometric bands, ugrizy, spanning a range of stellar densities and latitudes and overlapping with external reference datasets. The median image quality across all bands, measured by the FWHM of the point-spread function, is approximately 1.13 arcseconds, with the sharpest images reaching about 0.65 arcseconds. DP1 contains approximately 2.3 million distinct astrophysical objects, of which 1.6 million are extended in at least one band, and 431 solar system objects, of which 93 are new discoveries. DP1 is approximately 3.5 TB in size and available to Rubin data rights holders via the Rubin Science Platform, a cloud-based environment for the analysis of petascale astronomical data. While small compared to future LSST releases, its high quality and diversity of data support a broad range of early science investigations across all four LSST themes, providing a valuable opportunity to engage with Rubin data ahead of the start of full operations in late 2025.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

THE FREQUENCY OF HOT JUPITERS IN THE GALAXY: RESULTS FROM THE SuperLupus SURVEY

We present the results of the SuperLupus Survey for transiting hot Jupiter planets, which monitored a single Galactic disk field spanning 0.66 deg{sup 2} for 108 nights over three years. Ten candidates were detected: one is a transiting planet, two remain candidates, and seven have been subsequently identified as false positives. We construct a new image quality metric, S{sub j} , based on the behavior of 26,859 light curves, which allows us to discard poor images in an objective and quantitative manner. Furthermore, in some cases we are able to identify statistical false positives by analyzing temporal correlations between S{sub j} and transit signatures. We use Monte Carlo simulations to measure our detection efficiency by injecting artificial transits onto real light curves and applying identical selection criteria as used in our survey. We find at 90% confidence level that 0.10{sup +0.27}{sub -0.08}% of dwarf stars host a hot Jupiter with a period of 1-10 days. Our results are consistent with other transit surveys, but appear consistently lower than the hot Jupiter frequencies reported from radial velocity surveys, a difference we attribute, at least in part, to the difference in stellar populations probed. In light of our determination of the frequency of hot Jupiters in Galactic field stars, previous null results for transiting planets in open cluster and globular cluster surveys no longer appear anomalously low.

79 ASTRONOMY AND ASTROPHYSICS↗

Astrometric performance of the Gemini multiconjugate adaptive optics system in crowded fields

The Gemini multiconjugate adaptive optics system (GeMS) is a facility instrument for the Gemini South telescope. It delivers uniform, near-diffraction-limited image quality at near-infrared wavelengths over a 2 arcmin field of view. Together with the Gemini South Adaptive Optics Imager (GSAOI), a near-infrared wide-field camera, GeMS/GSAOI's combination of high spatial resolution and a large field of view will make it a premier facility for precision astrometry. Potential astrometric science cases cover a broad range of topics including exoplanets, star formation, stellar evolution, star clusters, nearby galaxies, black holes and neutron stars, and the Galactic Centre. In this paper, we assess the astrometric performance and limitations of GeMS/GSAOI. In particular, we analyse deep, mono-epoch images, multi-epoch data and distortion calibration. In this work, we find that for single-epoch, undithered data, an astrometric error below 0.2 mas can be achieved for exposure times exceeding 1 min, provided enough stars are available to remove high-order distortions. We show however that such performance is not reproducible for multi-epoch observations, and an additional systematic error of ~0.4 mas is evidenced. This systematic multi-epoch error is the dominant error term in the GeMS/GSAOI astrometric error budget, and it is thought to be due to time-variable distortion induced by gravity flexure.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-661: Quantitative MRI Assessment of a Novel Direction-Modulated Brachytherapy Tandem Applicator for Cervical Cancer

Purpose: To quantitatively evaluate the MR image quality of a novel direction modulated brachytherapy (DMBT) tandem applicator for cervical cancer, using the clinical MRI scanning protocol for image guided brachytherapy. Methods: The tungsten alloy-based applicator was placed in a water phantom and clinical imaging protocol was performed. Axial images were acquired using 2D turbo-spin echo (TSE) T2-weighted sequence on a 1.5T GE 450w MR scanner and an 8-channel body coil. As multi-channel receiver coil was used, inhomogeneities in the B1 receive field must be considered before performing the quantification process. Therefore the applicator was removed from the phantom and the whole imaging session was performed again for the water phantom with the same parameters. Images from the two scans were then subtracted, resulting in a difference image that only shows the applicator with its surrounding magnetic susceptibility dipole artifact. Line profiles were drawn and plotted on the difference image at various angles and locations along the tandem. Full width at half maximum (FWHM) was measured at all the line profiles to quantify the extent of the artifact. Additionally, the extent of the artifact along the diameter of the tandem was measured at various angles and locations. Results: After removing the background inhomogeneities of the receiver coil, FWHM of the tandem measured 5.75 ± 0.35 mm (the physical tandem diameter is 5.4 mm). The average extent of the artifacts along the diameter of the tandem measured is 2.14 ± 0.56 mm. In contrast to CT imaging of the same applicator (not shown here), the tandem can be easily identified without additional correction algorithms. Conclusion: This work demonstrated that the novel DMBT tandem applicator has minimal susceptibility artifact in T2-weighted images employed in clinical practice for MRI-guided brachytherapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-IeP1-09: MRI Evaluation of a Direction-Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer On 3T

Purpose: To assess image quality and artifact extent of a novel direction modulated brachytherapy (DMBT) tandem applicator on a 3T MRI using various clinical imaging sequences. Methods: The tandem applicator is composed of a tungsten alloy with 6 peripheral grooves covered with a PEEK tip. An MR-compatible phantom with similar dimensions to the female pelvis was manufactured. To visually assess the spatial shift of the applicator’s tip, a mountable radial-fiducial with 4 plastic rods, each of 3mm diameter, was designed to tightly fit on the applicator. The rods are separated by 16 mm and mounted at 90-degree relative to one another. The pelvis phantom was filled with a solution of MnCl2 to mimic T2 relaxation time of the cervix (60-80 ms at 3T).Imaging was performed on a 3T Philips Achieva using a 16-channel Torso coil array. Four MR sequences were tested: T2-weighted fast spin-echo (T2w-FSE), proton density weighted FSE (PDw-FSE), T1-weighted FSE (T1w-FSE) and T1 weighted spoiled gradient echo (T1w-GE). The spatial resolution was kept the same between all sequences: 0.6 × 0.6 × 3 mm{sup 3} with no slice gaps. Para-sagittal images were acquired with the applicator fixed at a 30-degree angle anterior to the B0- field to mimic clinical settings. Results: Minimal artifacts were observed on T2w-FSE, PDw-FSE and T1-FSE, while significant artifacts were seen on T1w-GE images. Artifacts induced in all 3 FSE sequences did not hinder accurate localisation of the tip and the applicator boundaries. The drift of the applicator’s centreline from the radial fiducials was measured and found to be < 1 mm for the 3 FSE sequences. Conclusion: The tungsten–based DMBT applicator can be potentially used on 3T with various clinical sequences without inducing significant artifacts. Further validation on patients as well as the evaluation of relative SNR among the different sequences is required.

60 APPLIED LIFE SCIENCES↗

Design and evaluation of controls for drift, video gain, and color balance in spaceborne facsimile cameras

The facsimile camera is an optical-mechanical scanning device which has become an attractive candidate as an imaging system for planetary landers and rovers. This paper presents electronic techniques which permit the acquisition and reconstruction of high quality images with this device, even under varying lighting conditions. These techniques include a control for low frequency noise and drift, an automatic gain control, a pulse-duration light modulation scheme, and a relative spectral gain control. Taken together, these techniques allow the reconstruction of radiometrically accurate and properly balanced color images from facsimile camera video data. These techniques have been incorporated into a facsimile camera and reproduction system, and experimental results are presented for each technique and for the complete system.

Katzberg, S. J.↗

Cryogenic Optical Performance of the Cassini Composite InfraRed Spectrometer (CIRS) Flight Telescope

The CIRS half-meter diameter beryllium flight telescope's optical performance was tested at the instrument operating temperature of 170 Kelvin. The telescope components were designed at Goddard Space Flight Center (GSFC) but fabricated out of house and then assembled, aligned and tested upon receipt at GSFC. A 24 inch aperture cryogenic test facility utilizing a 1024 x 1024 CCD array was developed at GSFC specifically for this test. The telescope,s image quality (measured as encircled energy), boresight stability and focus stability were measured. The gold coated beryllium design exceeded the cold image performance requirement of 80% encircled energy within a 460 micron diameter circle.

Losch, Patricia↗

Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts

Harmonic imaging is a new ultrasonographic technique that is designed to improve image quality by exploiting the spontaneous generation of higher frequencies as ultrasound propagates through tissue. We studied 51 difficult-to-image patients with blinded side-by-side cineloop evaluation of endocardial border definition by harmonic versus fundamental imaging. In addition, quantitative intensities from cavity versus wall were compared for harmonic versus fundamental imaging. Harmonic imaging improved left ventricular endocardial border delineation over fundamental imaging (superior: harmonic = 71.1%, fundamental = 18.7%; similar: 10.2%; P <.001). Quantitative analysis of 100 wall/cavity combinations demonstrated brighter wall segments and more strikingly darker cavities during harmonic imaging (cavity intensity on a 0 to 255 scale: fundamental = 15.6 +/- 8.6; harmonic = 6.0 +/- 5.3; P <.0001), which led to enhanced contrast between the wall and cavity (1.89 versus 1.19, P <.0001). Harmonic imaging reduces side-lobe artifacts, resulting in a darker cavity and brighter walls, thereby improving image contrast and endocardial delineation.

NASA Discipline Cardiopulmonary↗

Post Launch Calibration and Testing of the Geostationary Lightning Mapper on GOES-R Satellite

The Geostationary Operational Environmental Satellite R (GOES-R) series is the planned next generation of operational weather satellites for the United States National Oceanic and Atmospheric Administration (NOAA). The National Aeronautics and Space Administration (NASA) is procuring the GOES-R spacecraft and instruments with the first launch of the GOES-R series planned for October 2016. Included in the GOES-R Instrument suite is the Geostationary Lightning Mapper (GLM). GLM is a single-channel, near-infrared optical detector that can sense extremely brief (800 s) transient changes in the atmosphere, indicating the presence of lightning. GLM will measure total lightning activity continuously over the Americas and adjacent ocean regions with near-uniform spatial resolution of approximately 10 km. Due to its large CCD (1372x1300 pixels), high frame rate, sensitivity and onboard event filtering, GLM will require extensive post launch characterization and calibration. Daytime and nighttime images will be used to characterize both image quality criteria inherent to GLM as a space-based optic system (focus, stray light, crosstalk, solar glint) and programmable image processing criteria (dark offsets, gain, noise, linearity, dynamic range). In addition ground data filtering will be adjusted based on lightning-specific phenomenology (coherence) to isolate real from false transients with their own characteristics. These parameters will be updated, as needed, on orbit in an iterative process guided by pre-launch testing. This paper discusses the planned tests to be performed on GLM over the six-month Post Launch Test period to optimize and demonstrate GLM performance.

validation↗

Post Launch Calibration and Testing of the Geostationary Lightning Mapper on the GOES-R Satellite

The Geostationary Operational Environmental Satellite R (GOES-R) series is the planned next generation of operational weather satellites for the United States National Oceanic and Atmospheric Administration (NOAA). The National Aeronautics and Space Administration (NASA) is procuring the GOES-R spacecraft and instruments with the first launch of the GOES-R series planned for October 2016. Included in the GOES-R Instrument suite is the Geostationary Lightning Mapper (GLM). GLM is a single-channel, near-infrared optical detector that can sense extremely brief (800 microseconds) transient changes in the atmosphere, indicating the presence of lightning. GLM will measure total lightning activity continuously over the Americas and adjacent ocean regions with near-uniform spatial resolution of approximately 10 km. Due to its large CCD (1372x1300 pixels), high frame rate, sensitivity and onboard event filtering, GLM will require extensive post launch characterization and calibration. Daytime and nighttime images will be used to characterize both image quality criteria inherent to GLM as a space-based optic system (focus, stray light, crosstalk, solar glint) and programmable image processing criteria (dark offsets, gain, noise, linearity, dynamic range). In addition ground data filtering will be adjusted based on lightning-specific phenomenology (coherence) to isolate real from false transients with their own characteristics. These parameters will be updated, as needed, on orbit in an iterative process guided by pre-launch testing. This paper discusses the planned tests to be performed on GLM over the six-month Post Launch Test period to optimize and demonstrate GLM performance.

validation↗

Poster for 12th World Conference for Neutron Radiography (WCNR-12)

Complimentary Relationships Between Neutron Computed Radiography and Digital X-ray Radiography of Radioactive Specimens The Transient Reactor Test (TREAT) Facility is a 19,000 MW reactor located at the Idaho National Laboratory which is used for transient testing of materials and experiments. A neutron radiography facility is installed which allows for low resolution neutron imaging with a capability of items up to 20 cm wide and 400 cm long. Along with the neutron radiography facility, a 370 kV digital X-ray system is located onsite for when X-ray imaging is more practical or when rapid imaging is requested. The X-ray facility can accommodate specimens up to 61 cm wide and 1000 cm long. This poster discusses the complimentary relationship between transfer-method Neutron Computed Radiography (nCR) and Digital X-ray Radiography (DR) imaging of radioactive specimens along with practical applications for nuclear fuels and materials testing programs. Both nCR and DR images were acquired of inert gas and water filled apparatus containing differing materials at varying radiation levels. Highly radioactive items have no effect on nCR image quality whereas radioactivity has varying degrees of effect in DR. Radioactive items as high as 20 mSv/h have been successfully imaged using X-ray DR methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulating realistic imaging conditions for in situ liquid microscopy

In situ transmission electron microscopy enables the imaging of biological cells, macromolecular protein complexes, nanoparticles, and other systems in a near-native environment. In order to improve interpretation of image contrast features and also predict ideal imaging conditions ahead of time, new virtual electron microscopic techniques are needed. A technique for virtual fluid-stage high-angle annular dark-field scanning transmission electron microscopy with the multislice method is presented that enables the virtual imaging of model fluid-stage systems composed of millions of atoms. The virtual technique is exemplified by simulating images of PbS nanoparticles under different imaging conditions and the results agree with previous experimental findings. General insight is obtained on the influence of the effects of fluid path length, membrane thickness, nanoparticle position, defocus and other microscope parameters on attainable image quality.

Atomistic model↗

THE COLOR-MAGNITUDE RELATION FOR METAL-POOR GLOBULAR CLUSTERS IN M87: CONFIRMATION FROM DEEP HST/ACS IMAGING

Metal-poor globular clusters (GCs) are our local link to the earliest epochs of star formation and galaxy building. Studies of extragalactic GC systems using deep, high-quality imaging have revealed a small but significant slope to the color-magnitude relation for metal-poor GCs in a number of galaxies. We present a study of the M87 GC system using deep, archival HST/ACS imaging with the F606W and F814W filters, in which we find a significant color-magnitude relation for the metal-poor GCs. The slope of this relation in the I versus V-I color-magnitude diagram (gamma {sub I} = -0.024 +- 0.006) is perfectly consistent with expectations based on previously published results using data from the ACS Virgo Cluster Survey. The relation is driven by the most luminous GCs, those with M{sub I} {approx}< -10, and its significance is largest when fitting metal-poor GCs brighter than M{sub I} = -7.8, a luminosity which is {approx}1 mag fainter than our fitted Gaussian mean for the luminosity function (LF) of blue, metal-poor GCs ({approx}0.8 mag fainter than the mean for all GCs). These results indicate that there is a mass scale at which the correlation begins, and is consistent with a scenario where self-enrichment drives a mass-metallicity relationship. We show that previously measured half-light radii of M87 GCs from best-fit PSF-convolved King models are consistent with the more accurate measurements in this study, and we also explain how the color-magnitude relation for metal-poor GCs is real and cannot be an artifact of the photometry. We fit Gaussian and evolved Schechter functions to the luminosity distribution of GCs across all colors, as well as divided into blue and red subpopulations, finding that the blue GCs have a brighter mean luminosity and a narrower distribution than the red GCs. Finally, we present a catalog of astrometry and photometry for 2250 M87 GCs.

79 ASTRONOMY AND ASTROPHYSICS↗

Classification and Localization of Fracture-Hit Events in Low-Frequency Distributed Acoustic Sensing Strain Rate with Convolutional Neural Networks

Summary Distributed acoustic sensing (DAS) has been used in the oil and gas industry as an advanced technology for surveillance and diagnostics. Operators use DAS to monitor hydraulic fracturing activities, examine well stimulation efficacy, and estimate complex fracture system geometries. Particularly, low-frequency DAS can detect geomechanical events such as fracture hits because hydraulic fractures propagate and create strain rate variations in the rock. Analysis of DAS data today is mostly done post-job and subject to interpretation methods. However, the continuous and dense data stream generated live by DAS poses the opportunity for more efficient and accurate real-time data-driven analysis. The objective of this study is to develop a machine learning-based workflow that can identify and locate fracture-hit events in simulated strain rate responses correlated with low-frequency DAS data. In this paper, “fracture hit” refers to a hydraulic fracture originating from a stimulated well intersecting an offset well. We start with building a single fracture propagation model to produce strain rate patterns observed at a hypothetical monitoring well. This model is used to generate two sets of strain rate responses with one set containing fracture-hit events. The labeled synthetic data are then used to train a custom convolutional neural network (CNN) model for identifying the presence of fracture-hit events. The same model is trained again for locating the event with the output layer of the model replaced with linear units. We achieved near-perfect predictions for both event classification and localization. These promising results prove the feasibility of using CNN for real-time event detection from fiber-optic sensing data. Additionally, we use edge detection techniques to recognize fracture-hit event patterns in strain rate images. The fracture-hit location can be identified using recognized pixels in the image. The accuracy of edge detection-based location identification is also plausible, but edge detection is dependent on the assumption of pattern shape and image quality, hence it is less robust compared to CNN models. This comparison further supports the need for CNN applications in image-based real-time fiber-optic sensing event detection.

Engineering↗

Apodized RFI Filtering of Synthetic Aperture Radar Images

Fine resolution Synthetic Aperture Radar (SAR) systems necessarily require wide bandwidths that often overlap spectrum utilized by other wireless services. These other emitters pose a source of Radio Frequency Interference (RFI) to the SAR echo signals that degrades SAR image quality. Filtering, or excising, the offending spectral contaminants will mitigate the interference, but at a cost of often degrading the SAR image in other ways, notably by raising offensive sidelobe levels. This report proposes borrowing an idea from nonlinear sidelobe apodization techniques to suppress interference without the attendant increase in sidelobe levels. The simple post-processing technique is termed Apodized RFI Filtering (ARF).

42 ENGINEERING↗