Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high angular resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

VLA Imaging of Protoplanetary Environments

We continue to use the Very Large Array (VLA) of the National Radio Astronomy Observatories (NRAO) to make high resolution images of thermal emission in the protoplanetary environment of nearby young stars. The VLA provides two unique capabilities. First, the angular resolution for imaging thermal emission is unmatched by any other facility. For the A array, the synthesized beam at a wavelength of 7 mm corresponds to a linear scale similar to the orbital radius of Jupiter at the distance of nearby dark clouds Eke Taurus. Second, the long millimeter wavelengths accessible to the VLA are particularly advantageous at this high resolution since the emission is (almost) entirely optically thin and probes the full disk column, including the innermost regions that remain opaque to shorter wavelengths.

Wilner, David J.↗

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS)

EUNIS (Extreme Ultraviolet Normal Incidence Spectrograph) is a high-efficiency extreme ultraviolet spectrometer that is expected to fly for the first time in 2004 as a sounding rocket payload. Using two independent optical systems, EUNIS will probe the structure and dynamics of the inner solar corona high spectral resolution in two wavelength regions: 17-21 nm with 3.5 pm resolution and 30-37 nm with 7 pm resolution. The long wavelength channel includes He II 30.4 nm and strong lines from Fe XI-XVI; the short wavelength channel includes strong lines of Fe IX-XIII. Angular resolution of 2 arcsec is maintained along a slit covering a full solar radius. EUNIS will have 100 times the throughput of the highly successful SERTS payloads that have preceded it. There are only two reflections in each optical channel, from the superpolished, off-axis paraboloidal primary and the toroidal grating. Each optical element is coated with a high-efficiency multilayer coating optimized for its spectral bandpass. The detector in each channel is a microchannel plate image intensifier fiber- coupled to three 1K x 1K active pixel sensors. EUNIS will obtain spectra with a cadence as short as 1 sec, allowing unprecedented studies of the physical properties of evolving and transient structures. Diagnostics of wave heating and reconnection wil be studied at heights above 2 solar radii, in the wind acceleration region. The broad spectral coverage and high spectral resolution will provide superior temperature and density diagnostics and will enable underflight calibration of several orbital instruments, including SOHO/CDS and EIT, TRACE, Solar-B/EIS, and STEREO/EUVI. EUNIS is supported by NASA through the Low Cost Access to Space Program in Solar and Heliospheric Physics.

Oegerle, William↗

Large-aperture high-resolution X-ray collimator for the Solar Maximum Mission

A description is presented of a flight-qualified large-aperture 12 x 12-arcsec angular resolution multigrid X-ray collimator developed for the Solar Maximum Mission (SMM) flat crystal spectrometer. This collimator, designed for the 1.4-22.4-A wavelength range, utilizes an optical bench/metering structure to align and support prealigned grid subassemblies. The optical bench is a lightweight, rigid, and stable aluminum honeycomb structure. The grids are of a compound and bimetallic design, having 63.5-micron square holes on an 88.9-micron spacing in 8-micron thick gold, which is in turn supported by a 76-micron thick Invar grid having 600-micron square holes on a 739-micron spacing. The small apertures in the gold provide the 12-arcsec collimation with the Invar grids providing wide angle off-axis blocking out to an approximately 35 arcmin view angle. The collimator has seven individual channels, four of a 5.1- x 10-cm area and three of a 1.3- x 10-cm area. Laboratory measurements gave an average angular resolution of 12.5 arcsec FWHM with 0.259 transmission for the large-area channels and 12.0 arcsec and 0.200 transmission for the small-area channels. A thermal filter composed of two layers of approximately 1000-A thick aluminum prevents solar heating of the front collimator grids by absorbing longer wavelength radiation while passing most of the X radiation in the band of interest.

Nobles, R. A.↗

A Light and Effective Wide Field Monitor for Gamma Ray Bursts and Transient Sources

We present here a concept for a light and low-power wide field monitor working in the X-ray range, suitable for simultaneous imaging of large portions of the sky and GRB localizations. Our concept evolves from and improves on the design of the 5-kg SuperAGILE experiment, flying on the AGILE mission and currently delivering arcmin-localizations of GRBs at a rate of about 1/month. Similar to SuperAGILE, our concept is based on position sensitive silicon detectors equipped with one-dimensional coded masks. Different options are available for the detector, whose properties, combined with the scientific requirements, drive the design of the experiment. Our approach is based on a modular detector. The experiment design can then be tailored to specific scientific goals of the experiment or the mission (e.g., to cite GRBs only: the brightest GRBs/XRFs on a large field of view - FoV, or many low-fluence GRBs/XRFs on a smaller FoV, or the low energy spectrum of the prompt event, or the detection of high-z GRBs). In this paper we describe the concept, the main detector properties and outline some possible experiment configurations, with examples of their expected performance. Different experiment configurations in terms of area, FoV, angular resolution may be designed starting from the same detectors. Instead, the band-pass is mostly related to the detector properties. A key point of our project is the high degree of readiness of the detectors that are at production level and may be immediately proposed for a future experiment onboard missions with high readiness requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization fraction of Planck Galactic cold clumps and forecasts for the Simons Observatory

ABSTRACT We measure the mean-squared polarization fraction of a sample of 6282 Galactic cold clumps at 353 GHz, consisting of Planck Galactic cold clump (PGCC) catalogue category 1 objects [flux densities measured with signal-to-noise ratio (S/N) > 4]. At 353 GHz, we find the mean-squared polarization fraction, which we define as the mean-squared polarization divided by the mean-squared intensity, to be (4.79 ± 0.44) × 10−4 equation to an $11\, \sigma$ detection of polarization. We test if the polarization fraction depends on the clumps’ physical properties, including flux density, luminosity, Galactic latitude, and physical distance. We see a trend towards increasing polarization fraction with increasing Galactic latitude, but find no evidence that polarization depends on the other tested properties. The Simons Observatory, with angular resolution of order 1 arcmin and noise levels between 22 and $54\, \mu$K−arcmin at high frequencies, will substantially enhance our ability to determine the magnetic field structure in Galactic cold clumps. At $\ge 5\, \sigma$ significance, we predict the Simons Observatory will detect at least ∼12 000 cold clumps in intensity and ∼430 cold clumps in polarization. This number of polarization detections would represent a two orders of magnitude increase over the current Planck results. We also release software that can be used to mask these Galactic cold clumps in other analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopy of states in 136 Ba using the 138 Ba(p,t) reaction

Background: The 136 Ba isotope is the daughter nucleus in 136 Xe $ββ$ decay. It also lies in a shape transitional region of the nuclear chart, making it a suitable candidate to test a variety of nuclear models. Purpose: To obtain spectroscopic information on states in 136 Ba, which will allow a better understanding of its low-lying structure. These data may prove useful to constrain future 136 Xe → 136 Ba neutrinoless $ββ$ decay matrix element calculations. Methods: Here, a 138 Ba(p, t) reaction was used to populate states in 136 Ba up to approximately 4.6 MeV in excitation energy. The tritons were detected using a high-resolution Q3D magnetic spectrograph. A distorted wave Born approximation analysis was performed for the measured triton angular distributions. Results: 102 excited states in 136 Ba were observed, out of which 52 are reported for the first time. Definite spin-parity assignments are made for 26 newly observed states, while previously ambiguous assignments for ten other states are resolved. Together with other available data, the results are used to determine level densities in 136 Ba. These were compared with theory predictions, obtained using shell model calculations with Hamiltonians previously used for 136 Xe neutrinoless $ββ$ decay matrix element evaluations. Conclusions: The shell model predicted level densities agree reasonably well for the two Hamiltonians. However the results for theory and experiment are found to agree only at lower energies, diverging from one another for the higher lying states, with the discrepancy increasing with energy. This is presumably because of lower production cross sections for a majority of the higher-lying predicted states and the experimental limitations in resolving a large number of nearly degenerate states predicted by the theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of optical/IR blocking filters for the Lynx X-ray Microcalorimeter [Design of optical/IR blocking filters for the Lynx S-ray Microcalorimeter (LXM)]

The Lynx mission concept, under development ahead of the 2020 Astrophysics Decadal Review, includes the Lynx X-ray Microcalorimeter (LXM) as one of its main instruments. The LXM uses a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution nondispersive spectroscopy in the soft x-ray waveband (0.2 to 15 keV) with exquisite angular resolution. Similar to other x-ray microcalorimeters, the LXM uses a set of blocking filters mounted within the dewar that pass the photons of interest (x-rays) while attenuating the out-of-band long-wavelength radiation. Such filters have been successfully used on previous orbital and suborbital instruments; yet, the Lynx science objectives, which emphasize observations in the soft x-ray band (<1 keV), pose more challenging requirements on the set of LXM blocking filters. We present an introduction to the design of the LXM optical/IR blocking filters and discuss recent advances in filter capability targeted at LXM. In addition, we briefly describe the external filters and the modulated x-ray sources to be used for onboard detector calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, less EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recent Cross-Section Results from MicroBooNE

MicroBooNE is a liquid argon time projection chamber in the Booster Neutrino Beam at Fermilab. The large event rate and 3 mm wire spacing of the detector provide high-statistics, precise-resolution imaging of neutrino interactions leading to low-threshold, high-efficiency event reconstruction with full angular coverage. As such, this is an ideal place to probe neutrino-argon interactions in the hundreds-of-MeV to few-GeV energy range, and to study the impact of nuclear effects through detailed measurements of hadronic final states. These proceedings present recent measurements of neutrino interactions in MicroBooNE, including inclusive charged-current interactions, neutral-pion production, and measurements of low-energy protons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Survey of the galactic background radiation at 3.93 and 6.55 MHz

A survey of the galactic background radiation at 3.93 and 6.55 MHz is presented for the region between declinations of -60 and +60 deg. The observations were obtained with the 229-m traveling-wave V-antenna on the Radio Astronomy Explorer-1 satellite with an angular resolution of the order of one steradian. The results are consistent with the findings of high-resolution ground-based surveys at low frequencies and provide a first step in extending such observations over the whole sky.

Alexander, J. K.↗

The Circumstellar Environment of Low Mass Star Forming Regions

The final technical report of the NASA grant project is presented. The goals of the grant were to: (1) analyze the data from the Far-Infrared (FIR) Camera on board the Kuiper Airborne Observatory (KAO); (2) acquire additional data at other wavelengths for models and (4) to develop source models for the Young stellar objects (YSOs)under study. The complete Spectral Energy Distribution (SED) from 10 microns out to 1.3 mm for all sources being studied have been obtained. The FIR imaging data was processed to reveal the maximum angular resolution possible, which allows us to model the disk. To model the disk we have the high resolution millimeter interferometry data. In summary the results to date are: (1) the vast majority of embedded YSOs in Taurus are compact at 100 microns. The models mos consistent with our data and other observations are either dominated by disk emissions, or envelopes that have relatively steep density gradients; (2) the submillimeter/millimeter photometer suggests that models are very successful. Disk emission plays an important role and must be considered when predicting the overall emission. (3) in the two cases, where we seem to have extended emission, we have to investigate other possible source models than a Shu collapse.

Butner, Harold M.↗

Prospects for GLAST

The Gamma-ray Large Area Space Telescope (GLAST), scheduled for launch in late 007, is a satellite based observatory to study the high energy gamma-ray sky. There are two instruments on GLAST: the Large Area Telescope (LAT) which provides coverage from 20 MeV to over 300 GeV, and the GLAST Burst Monitor (GBM) which provides supportive observations of transients from 8 keV to 30 MeV. GLAST will provide well beyond those achieved by the highly successful EGRET instrument on the Compton Gamma-Ray Observatory, with dramatic improvements in sensitivity, angular resolution and energy range. The very large field of view will make it possible to observe approx. 20% of the sky at any instant, and the entire sky on timescale of a few hours. This talk includes a description of the instruments, the opportunities for guest investigators, and the mission status.

McEnery, Julie↗

Design of Optical/IR Blocking Filters for the Lynx X-Ray Microcalorimeter

The Lynx mission concept, under development ahead of the 2020 Astrophysics Decadal Review, includes the Lynx X-ray Microcalorimeter (LXM) as one of its primary instruments. The LXM uses a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution nondispersive spectroscopy in the soft x-ray waveband (0.2 to 15 keV) with exquisite angular resolution. Similar to other x-ray microcalorimeters, the LXM uses a set of blocking filters mounted within the dewar that pass the photons of interest (x-rays) while attenuating the out-of-band long-wavelength radiation. Such filters have been successfully used on previous orbital and suborbital instruments; however, the Lynx science objectives, which emphasize observations in the soft x-ray band (<1keV), pose more challenging requirements on the set of LXM blocking filters. We present an introduction to the design of the LXM optical/IR blocking filters and discuss recent advances in filter capability targeted at LXM. In addition, we briefly describe the external filters and the modulated x-ray sources to be used for onboard detector calibration.

Eckart, Megan E.↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

The future of high energy gamma ray astronomy and its potential astrophysical implications

Future satellites should carry instruments having over an order of magnitude greater sensitivity than those flown thus far as well as improved energy and angular resolution. The information to be obtained from these experiments should greatly enhance knowledge of: the very energetic and nuclear processes associated with compact objects; the structure of our galaxy; the origin and dynamic pressure effects of the cosmic rays; the high energy particles and energetic processes in other galaxies; and the degree of matter-antimatter symmetry of the universe. The relevant aspects of extragalactic gamma ray phenomena are emphasized along with the instruments planned. The high energy gamma ray results of forthcoming programs such as GAMMA-1 and the Gamma Ray Observatory should justify even more sophisticated telescopes. These advanced instruments might be placed on the space station currently being considered by NASA.

Fichtel, C. E.↗

A comparison of high resolution radio and far-infrared maps of M 17

New 3.5-cm radio and 69-micron far-infrared maps of M17, both made with an angular resolution of about 1.5 arcmin, are presented. Each map has three distinct maxima. Two of the maxima on the far-IR map agree in position with the corresponding maxima on the radio map. However, the positions of the brightest peak in the radio and far-infrared maps, located in the SW part of M17, differ by 4.6 + or - 2.2 s in right ascension and +44 + or - 20 sec in declination, with the far-infrared peak lying between the radio peak and the dense molecular cloud southwest of the H II region. It is believed that the positional offset of the radio and far-infrared peak is physically significant. The origin of the far-infrared radiation appears to be thermal emission from dust at the interface of the ionized gas and molecular cloud. This interface region is probably heated by radiation from the H II region.

Wilson, T. L.↗

Characterization of shaped Bragg crystal assemblies for narrowband x-ray imaging

X-ray imaging using shaped crystals in Bragg reflection is a powerful technique used in high-energy-density physics experiments. The characterization of these crystal assemblies with conventional x-ray sources is very difficult because of the required angular resolution of the order of ~10 μrad and the narrow bandwidth of the crystal. The 10-J, 1-ps Multi-Terawatt (MTW) laser at the Laboratory for Laser Energetics was used to characterize a set of Bragg crystal assemblies. The small spot size (of the order of 5 μm) and the high power (>10 18 W/cm 2 ) of this laser make it possible to measure the spatial resolution at the intended photon energy. A set of six crystals from two different vendors was checked on MTW, showing an unexpectedly large variation in spatial resolution of up to a factor of 4.

47 OTHER INSTRUMENTATION↗

HIGH-VELOCITY MOLECULAR OUTFLOW IN CO J = 7-6 EMISSION FROM THE ORION HOT CORE

Using the Caltech Submillimeter Observatory 10.4 m telescope, we performed sensitive mapping observations of {sup 12}CO J = 7-6 emission at 807 GHz toward Orion IRc2. The image has an angular resolution of 10'', which is the highest angular resolution data toward the Orion Hot Core published for this transition. In addition, thanks to the on-the-fly mapping technique, the fidelity of the new image is rather high, particularly in comparison with previous images. We have succeeded in mapping the northwest-southeast high-velocity molecular outflow, whose terminal velocity is shifted by {approx}70-85 km s{sup -1} with respect to the systemic velocity of the cloud. This yields an extremely short dynamical time scale of {approx}900 years. The estimated outflow mass loss rate shows an extraordinarily high value, on the order of 10{sup -3} M {sub sun} yr{sup -1}. Assuming that the outflow is driven by Orion IRc2, our result agrees with the picture so far obtained for a 20 M {sub sun} (proto)star in the process of formation.

79 ASTRONOMY AND ASTROPHYSICS↗