Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “helicity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Double helical structure of the twist-bend nematic phase investigated by resonant X-ray scattering at the carbon and sulfur K-edges

The mesogenic dimer displaying nematic and N TB phases was investigated by resonant X-ray scattering at both C and S absorption K-edges and supported by single X-ray crystallography. In the crystal resonant studies revealed the forbidden reflection in non-resonant diffraction similar to that found in the NTB phase. Finally, the lack of a second harmonic in both C and S resonant X-ray scattering supports the double helical structure of the twist-bend nematic phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designed asymmetric coordination helicates with bis-β-diketonate ligands

A new bis-(β-diketone) ligand featuring built-up structural asymmetry yields non-symmetric Fe(III) and Ga(III) dinuclear, triple-stranded helicates by design. Their structural properties have been studied, both in solid state and in solution, and compared with their corresponding symmetric analogues. Finally, the robustness observed shows the potential of this synthetic strategy to develop non-symmetric helicoidal motifs with specific functional groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous liquid-phase synthesis of nickel phosphide nanoparticles in a helically coiled tube reactor

The continuous liquid phase synthesis of nickel phosphide (Ni 2 P) nanoparticles was studied in a helically coiled tube (HCT) reactor both in single-phase and two-phase slug flows. The reactants were nickel acetylacetonate and tri-n-octylphosphine (TOP) in a 1-octadecane solvent. For the single-phase mode, various parameters such as reaction temperature, residence time, TOP concentration, and P/Ni ratio were studied. It was found that lower temperatures of 320 and 340 °C resulted in the formation of mixed Ni 12 P 5 and Ni 2 P phases, while a higher temperature of 360 °C gave mostly Ni 2 P, with particle sizes increasing from 28 to 42 nm. Upon varying the contact time between 88 and 340 s at 360 °C, a likely sequence of reaction involved an amorphous phase that was transformed in parallel to Ni, Ni 12 P 5 , and Ni 2 P. When the flow in the HCT was changed to a two-phase slug flow by using N 2 to split the continuous liquid phase into small liquid columns, the product was nearly 100% Ni 2 P and the particle size was as small as 3–4 nm. This was attributed to the enhanced mass transfer in the small liquid columns of the slug flow that led to higher reaction rates. Finally, it is highlighted that the HCT operated in a slug flow is an efficient and continuous method for the fabrication of nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A ferric guest inside a spin crossover ferrous helicate

A designed dimetallic Fe(II) helicate made with biphenylene-bridged bispyrazolylpyridine ligands and exhibiting a process of spin crossover at temperatures above ambient is shown to encapsulate an S = 5/2 tris-oxalato Fe(III) ion. The spin relaxation dynamics of this guest are strongly reduced upon encapsulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Z{sub eff} profile measurement system with an optimized Czerny-Turner visible spectrometer in large helical device

Z{sub eff} measurement system using a visible spectrometer has been newly designed and constructed instead of an old interference filter system to eliminate line emissions from the signal and to measure the Z{sub eff} value in low-density plasmas. The system consists of the Czerny-Turner-type spectrometer with a charge-coupled device camera and 44 optical fibers vertical array. The spectrometer is equipped with an additional toroidal mirror for further reduction in the astigmatism in addition to a flat and two spherical mirrors and three gratings (110, 120, and 1200 grooves/mm) with 30 cm focal length. The images from 44 optical fibers can be detected without astigmatism in a wavelength range of 200-900 nm. Combination of the optical fiber (core diameter: 100 {mu}m) with the lens (focal length: 30 mm) provides spatial resolution of 30 mm at the plasma center. Results clearly indicate a very good focus image of the fiber and suggest the absence of the cross-talk between adjacent fiber images. Absolute intensity calibration has been done using a standard tungsten lamp to analyze the Z{sub eff} value. The bremsstrahlung profile and resultant Z{sub eff} profile have been obtained after Abel inversion of the signals observed in large helical device plasmas with elliptical poloidal cross section.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a phase contrast imaging system based on a yttrium aluminum garnet laser with folded beam for observations of density fluctuations in compact helical system

A near-infrared laser phase contrast optical system incorporating a folded beam was developed in order to measure the distribution of density fluctuations in a high-temperature plasma. The coherent light source used was an yttrium aluminum garnet laser stabilized by a ring oscillator. The probe beam system separates and reflects the incident and exiting beams with a polarizer and a fully reflective mirror with a waveplate. This system was employed with a compact helical system to detect fluctuations at the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy resolved soft x-ray imaging using a charge coupled device camera for long pulse discharges in the Large Helical Device

Energy resolved soft x-ray imaging system using a charge coupled device camera and a multifilter disk has recently been installed to the Large Helical Device for the measurements in the long pulse discharges. Eight images with different cutoff energies are measured sequentially during a single discharge by rotating a filter disk mounting eight beryllium filters with different thicknesses. A tangential line-integrated profile for a specific photon energy range can be obtained by taking intensity difference between two images measured with a filter pair of adjacent thicknesses. The typical photon energy corresponding to each difference ranges from 1.9 to 4.8 keV with the bandwidth of 2-3 keV. In the initial results, the difference in the line-integrated soft x-ray profile by the energy range has been clearly observed. This diagnostic method can possibly be applied to the observation of the dependence of two dimensional soft x-ray profile on photon energy range especially if local non-Maxwellian component appears in electron energy distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast ion measurement using a hybrid directional probe in the large helical device

A hybrid directional probe was newly installed in the large helical device for fast ion measurement. The collector of the probe mounts a thermocouple to estimate local power flux and can be also utilized as a collector of a conventional Langmuir probe; therefore, the hybrid directional probe can simultaneously measure both local power density flux and current flux at the same collector surface. The concept and design of the hybrid directional probe, the calibration of the power density measurement, and preliminary result of the fast ion measurement are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic field fluctuation measurement with a heavy ion beam probe in the Large Helical Device

The measurements of magnetic field fluctuation with a heavy ion beam probe (HIBP) in the Large Helical Device (LHD) are considered in this article. Measured value reflects not only the fluctuation at the observation point (sample volume) but also the fluctuation on the beam path. These effects (called as the path integral effects) are considered and calculated for variations of fluctuations in LHD. The distortion of the measured profile by the path integral effect is not significant at the peak of the fluctuation amplitude. In contrast, in the region far from the peak, phony signals due to path integral effects are observed. Finally, the resolution of magnetic field fluctuation measurements with our HIBP system is estimated. Estimated results show that the magnitude of 4.1x10{sup -5} T can be measured with our system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ion charge exchange spectroscopy measurement using a radially injected neutral beam on the large helical device

An experimental technique to investigate fast ion confinement based on charge exchange spectroscopy of H{sub {alpha}}-light was applied to evaluate the confinement property of perpendicular fast ions in large helical device (LHD). Sensitivities of the H{sub {alpha}} spectra to the pitch angles of injected neutral beams (NBs) and these to the angle between the sight line of the measurement and NB injection path are examined. The energy dependence of the charge exchange cross section significantly affects the observed spectra since the driving NB is injected perpendicular to the magnetic field lines in the geometry of LHD. The measured spectra are compared to the spectra of GNET simulation results and the simulated spectra agreed well with the experimental measurement when we take into account the contribution of halo neutrals. Although it is difficult to obtain the fast ion distribution functions directly, this technique provides useful experimental data in benchmarking simulation codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of electrostatic potential fluctuation using heavy ion beam probe in large helical device

Heavy ion beam probe (HIBP) for large helical device (LHD) has been improved to measure the potential fluctuation in high-temperature plasmas. The spatial resolution is improved to about 10 mm by controlling the focus of a probe beam. The HIBP is applied to measure the potential fluctuation in plasmas where the rotational transform is controlled by electron cyclotron current drive. The fluctuations whose frequencies change with the time constant of a few hundreds of milliseconds and that with a constant frequency are observed. The characteristics of the latter fluctuation are similar to those of the geodesic acoustic mode oscillation. The spatial profiles of the fluctuations are also obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pellet charge exchange helium measurement using neutral particle analyzer in large helical device

It is very important to investigate the confinement of {alpha} particles, which will be produced by nuclear reactions in ITER and fusion reactors. The pellet charge exchange (PCX) measurement is one of the most powerful methods because it can directly provide the profile of the {alpha} particle energy spectra in a plasma. In the large helical device, PCX using tracer encapsulated solid pellet (TESPEL) has been tried in many hydrogen and helium plasmas, including helium accelerated by using the cyclotron resonance heating. In the PCX, we use the compact neutral particle analyzer without simultaneous mass separation ability. The helium particle measurement can be achieved by the application of voltage in the condenser plate. The scattering of hydrogen particle is carefully considered during the estimation of the helium amount. The radial helium profiles can also be obtained by comparing four TESPEL injection shots with/without higher harmonic fast wave heating and at applied plate voltages for He or H, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of collective Thomson scattering system using 77 GHz gyrotron for bulk and tail ion diagnostics in the large helical device

Collective Thomson scattering (CTS) system is expected to be a strong diagnostic tool for measuring thermal and fast ion distribution function at a local point inside plasmas. The electron cyclotron resonance heating system using a gyrotron at the frequency range of 77 GHz has been installed at the large helical device (LHD). The feasibility of CTS system using the 77 GHz gyrotron is assessed in terms of scattering spectrum and a background noise of the electron cyclotron emission, which affect the signal to noise ratio, with the realistic plasma parameters and incident port locations of LHD. Based on the calculated scattering spectra for bulk and tail fast ion diagnostics, the scattering radiation receiver system with gyrotron frequency feedback circuit is proposed to avoid the frequency chirping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of spatial structure of plasma potential and density fluctuations by multichannel heavy ion beam probe on large helical device

Heavy ion beam probe (HIBP) on large helical device is currently equipped with three channel detectors, which can observe three spatial points simultaneously inside the plasma with resolution of {approx}10 mm. The beam trajectories and observation point location are calculated numerically and optimized allowing for the identification of the mode structure in multichannel (up to 9) HIBP measurements. The calculations show that the radial and poloidal wavenumbers can be identified by proper changing and choosing of the beam energy and trajectory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗