Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Preface to the Special Issue on Signal Processing, Data Acquisition and Front-end Systems for Radiation Detection and Measurements

This special issue of the Journal of Signal Processing Systems focuses on advancement of signal processing and data-acquisition for radiation detection and measurements. The seven articles included cover diverse topics within the scope of radiation detection ranging from understanding of fundamental fission process, instrumentation, and application of radiation interaction (e.g., tomography and imaging). The articles focus on signal processing for fission spectrometer, neutron and gamma-ray computed tomography and artificial intelligence methods, dynamic neutron imaging system, pulse-pileup correction in x-ray spectroscopy and calibration methods in radiation measurement.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Using yttrium as an indicator to estimate total rare earth element concentration: a case study of anthracite-associated clays from northeastern Pennsylvania

Abstract This study demonstrated using yttrium (Y) as an indicator to estimate the total rare earth element and Y contents (REY) in coal-associated samples and to facilitate selection of samples with high REY assays in a fast and inexpensive manner. More than 10 anthracite-associated samples were collected from each of three Pennsylvanian sites (sites B, J and C) based on Thorium gamma ray logging suggesting high REY content. Several samples from each site were analyzed by ICP-MS to determine the rare earth distribution patterns and to establish the site-specific linear equations of Y and REY. The Y contents of the remaining samples were measured by a portable X-ray fluorescence analyzer, and the REY values were estimated based on the site-specific linear equation developed earlier. R-squared values above 0.70 were obtained for all the estimation equations from all three sites on both a whole sample basis and an ash basis. Previously, ash content has been widely used as an indicator of high REY content. This may not be applicable for a specific site. Site B in this study is an example where ash contents could not be statistically correlated with REY, so using Y for estimation is more applicable. The demonstrated sample screening process is suitable for samples from sites that share more similar distribution patterns (either MREY or LREY or HREY) as well as for samples from sites that share multiple distribution patterns (LREY/MREY/HREY) depending on the desirable accuracy. The demonstrated process lowers the analytical cost from $70 to 80 dollars per sample to $10–15 per sample while significantly reducing the processing time and acid consumption for ICP digestion. This is particularly true when a relatively large sample size is involved, for example, 100 samples from one site analyzed by ICP-MS/OES.

Yang, Xiaojing↗

Unveiling the Universe with emerging cosmological probes

The detection of the accelerated expansion of the Universe has been one of the major breakthroughs in modern cosmology. Several cosmological probes (Cosmic Microwave Background, Supernovae Type Ia, Baryon Acoustic Oscillations) have been studied in depth to better understand the nature of the mechanism driving this acceleration, and they are being currently pushed to their limits, obtaining remarkable constraints that allowed us to shape the standard cosmological model. In parallel to that, however, the percent precision achieved has recently revealed apparent tensions between measurements obtained from different methods. These are either indicating some unaccounted systematic effects, or are pointing toward new physics. Following the development of CMB, SNe, and BAO cosmology, it is critical to extend our selection of cosmological probes. Novel probes can be exploited to validate results, control or mitigate systematic effects, and, most importantly, to increase the accuracy and robustness of our results. This review is meant to provide a state-of-art benchmark of the latest advances in emerging “beyond-standard” cosmological probes. We present how several different methods can become a key resource for observational cosmology. In particular, we review cosmic chronometers, quasars, gamma-ray bursts, standard sirens, lensing time-delay with galaxies and clusters, cosmic voids, neutral hydrogen intensity mapping, surface brightness fluctuations, stellar ages of the oldest objects, secular redshift drift, and clustering of standard candles. The review describes the method, systematics, and results of each probe in a homogeneous way, giving the reader a clear picture of the available innovative methods that have been introduced in recent years and how to apply them. The review also discusses the potential synergies and complementarities between the various probes, exploring how they will contribute to the future of modern cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification of $^{3}$He–$^{3}$H clusters in the $^{6}$Li+$^{89}$Y experiment using particle-$\gamma$ coincidence measurement

The 6 Li+ 89 Y experiment was performed to explore the reaction mechanism induced by a weakly bound nucleus 6 Li and its cluster configuration. Here, the particle-$\gamma$ coincidence method was used to identify the different reaction channels. The $\gamma$-rays coincident with 3 He/ 3 H indicate that the 3 H/ 3 He stripping reaction plays a significant role in the formation of Zr/Nb isotopes. The obtained results support the existence of a 3 He- 3 H cluster in 6 Li. Direct and sequential transfer reactions are adequately discussed, and the FRESCO code is used to perform precise finite-range cyclic redundancy check calculations. In the microscopic calculation, direct cluster transfer is more predominant than sequential transfer in 3 H transfer. However, the direct cluster transfer is of comparable magnitude to the sequential transfer in the 3 He transfer.

CRC calculations↗

Westcott g factors extended to arbitrary neutron energy spectra

Westcott 𝑔 factors are used in Neutron Activation Analysis (NAA) and Prompt Gamma-ray Activation Analysis (PGAA) to evaluate the impact of non-1∕𝑣 behavior in the neutron-capture cross sections of certain nuclei on activation product yields. This non-1∕𝑣 behavior arises from the presence of neutron resonances in the neutron- capture cross sections that overlap with the source neutron spectrum at low (< 5 eV) energies. Historically, Westcott 𝑔 factors that have been cataloged for NAA and PGAA applications are the result of calculations that assume a Maxwellian neutron flux distribution with a given temperature. In this work, we use this approach with updated neutron-capture cross sections from the Evaluated Nuclear Data File, version VIII.1 (ENDF/B-VIII.1) to tabulate Westcott 𝑔 factor values for a broad range of Maxwellian distribution temperatures, comparing the results against currently-available 𝑔 factors from International Atomic Energy Agency tables and other sources. Here, it was discovered during this analysis that the use of guided thermal and cold-neutron beams at certain facilities necessitates an approach for evaluating Westcott 𝑔 factors based on arbitrary non-Maxwellian spectra. In this paper, we present an approach for calculating 𝑔 factors with user-specified neutron spectra, and we demonstrate these methods to obtain Westcott 𝑔-factors for guided- and cold-neutron beams at the Budapest Research Reactor and the Forschungsreaktor München II reactor. As part of this work, open-source software has been developed that can be used to perform these calculations for applications in PGAA and NAA experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boron coated straw-based neutron multiplicity counter for neutron interrogation of TRISO fueled pebbles

Pebble bed reactors (PBRs) can improve the safety and economics of the nuclear energy production. PBRs rely on TRIstructural-ISOtropic (TRISO) fuel pebbles for enhanced fission product retention. Accurate characterization of individual fuel pebbles would enable the validation of computational models, efficient use of TRISO fuel, and improve fuel accountability. Here, we have developed and tested a new neutron multiplicity counter (NMC) based on 192 boron coated straw (BCS) detectors optimized for 235 U assay in TRISO fuel. The new design yielded a singles and doubles neutron detection efficiency of 4.71% and 0.174%, respectively, and a die-away time of 16.7 μs. The NMC has a low intrinsic gamma-ray detection efficiency of 8.71 x 10 –8 at an exposure rate of 80.3 mR/h. In simulation, a high-efficiency version of the NMC encompassing 396 straws was able to estimate the 235 U in a pebble with a relative uncertainty and error both below 2% in 100 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary investigation of 48 V-labeled VO(acac) 2 for cancer imaging: An initial proof-of-concept study

In this preliminary study, a procedure for synthesizing novel PET radiotracer vanadium-48-labeled-vanadyl acetylacetonate was developed, including radioisotope production via cyclotron, separation of 48 V, chelation as 48 VO(acac) 2 , and assessment through in vitro cellular studies. We employed the beam-stop setup in a cyclotron as the target holder to irradiate titanium foils in the reaction of nat Ti (p,n) 48 V. The radioisotope production rate was 4.84 ± 0.67 μCi/μA-h. Overall radiochemical yield was 12.86 ± 0.51% with gamma-ray spectroscopy showing no detectable contaminant peaks. HPLC of 48 VO(acac) 2 showed a retention time (1:48) corresponding closely to that (1:50) of commercial VO(acac) 2 , verifying the successful synthesis of 8VO(acac) 2 . In vitro cellular studies demonstrated radiotracer uptake and saturation around 0.48 nM. These studies pave the way for improving methodologies and in vivo experiments, including imaging studies, in future investigations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase distribution in Fischer-Tropsch mimicked slurry bubble column via computed tomography

This study aims to investigate the phases distribution and hydrodynamics in an air-Therminol LT-glass beads slurry bubble column reactor in bubbly and churn-turbulent flow regimes by implementing a gamma-ray computed tomography. It is found that gas holdup increases with increasing superficial gas velocity and operating pressure while increasing solids loading has an opposite effect on gas holdup measurements. It is noticed that the pressure effect is more significant at high solids loading and the solids loading is relatively more substantial at lower pressure. Solids loading has the most significant a stronger effect on the solids holdup profile than on the gas holdup profile. Current results were compared with the Sedimentation-Dispersion Model (SDM) predictions. Overall, the findings of this study advance the knowledge of the true behavior of phases distribution in FT mimicked slurry bubble columns which are pertinent in designing such reactors.

42 ENGINEERING↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Intrinsic scintillation performance & europium concentration effects in RbSr 2 I 5 and RbSr 2 Br 5 scintillators

Scintillators play crucial roles in homeland security applications like gamma ray spectroscopy and high energy X-ray radiography. For promising new scintillators, fine-tuning the luminescent dopant concentration is one avenue to further improve their performance and tailor their properties. In this work, the effects of europium dopant concentrations on the crystal growth, luminescence and scintillation properties of RbSr 2 Br 5 and RbSr 2 I 5 crystals was investigated. Nine transparent 7 mm diameter single crystals were grown via the Vertical Bridgman method. Here, the optical band gap of RbSr 2 Br 5 was 5.9 eV and that of RbSr 2 I 5 was 4.7 eV. High scintillation performance was achieved with a relatively low europium concentration of 1 mol%. For both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu crystals, light yield of 60–90,000 ph/MeV, energy resolution 2.8–4.0 % at 662 keV, and X-ray afterglow 0.79–1.5 % at 2 ms were obtained.

36 MATERIALS SCIENCE↗

Radiolysis of thermally dehydrated gibbsite

Aluminum hydroxide (gibbsite, Al (OH) 3 ) powders and their thermally dehydrated forms were rehydrated and irradiated with gamma rays to examine the effects of the collapse of the crystalline gibbsite structure as it is converted to alumina on the transport of precursors of molecular hydrogen to the surface. The amount of hydrogen gas, H 2 , production from irradiated gibbsite and its transition phases with adsorbed water increased substantially with increasing temperature for dehydration of the samples, up to a point. Furthermore, the production of H 2 for samples without water was considerably lower than the hydrated samples signifying the importance of surface water and the transport of precursors to the surface. EPR spectroscopy showed that the major radiolytic products are trapped electrons and related O – centers. Thermal gravimetric analysis (TGA) measurements of gibbsite dehydration established the temperatures of phase transitions from gibbsite to alumina. Changes to the surface and structure of gibbsite and its transition phases following irradiation were analyzed using nitrogen adsorption, powder X-ray diffraction (pXRD), Raman spectroscopy, electron paramagnetic resonance (EPR), and scanning electron microscopy (SEM). pXRD and Raman spectra showed amorphorization at about 300 °C, coupled to a substantial increase in specific surface area due to increasing porosity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Structure and Decay Data for A=167 Isobars

Experimental nuclear spectroscopic data are compiled and evaluated for 17 known nuclides of mass 167 (Sm, Eu, Gd, Tb, Dy, Ho, Er Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt), 23 years after the previous full evaluation by 2000Ba65. Detailed information is presented for each reaction and decay experiment. Combining all the available data, recommended values are provided for energies, spins and parities, and half-lives of levels, with energies, branching ratios and multipolarities of γ radiations, and characteristics of β and α radiations in radioactive decays. Here, the α decays of A=171 nuclei to A=167 daughters are included in this work, while for α decays of A=167 nuclei to A=163 daughters, consult Nuclear Data Sheets (2010Re03) or the ENSDF database for A=163. 167 Er, 167 Tm, 167 Yb, 167 Lu and 167 Ta are among the most extensively studied nuclides via decay and high-spin gamma-ray spectroscopy measurements, followed by 167 Ho, 167 Hf, 167 W, and 167 Os. Information for excited states in 167 Dy, 167 Re, and 167 Ir are limited; no excited states have yet been identified in 167 Sm, 167 Eu, 167 Gd, 167 Tb and 167 Pt, with the ground-state half-life of 167 Sm remaining unknown. This work supersedes the earlier evaluation of A=167 nuclei by 2000Ba65.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Structure and Decay Data for A=165 Isobars

Experimental nuclear spectroscopic data are compiled and evaluated for 18 known nuclides of mass 165 (Pm, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt). Detailed information is presented for each reaction and decay experiment. Combining all the available data, recommended values are provided for energies, spins and parities, and half-lives of levels, with energies, branching ratios and multipolarities of γ radiations, and characteristics of β and α radiations in radioactive decays. 165 Dy, 165 Ho, 165 Er, 165 Tm, 165 Yb, 165 Lu and 165 Hf are among the most extensively studied nuclides via decay and high-spin gamma-ray spectroscopy measurements, followed by limited data for 165 Tb, 165 Ta, 165 W, 165 Re, and 165 Os. No excited states have yet been identified in 165 Sm, 165 Gd, and 165 Pt, while for 165 Eu and 165 Ir, information is available for only the g.s. and an isomer, but with no γ rays. As a result, this work supersedes earlier evaluation of A=165 nuclides by 2006Ja09.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropic neutron response of trans-stilbene and impact on a handheld dual particle imager

Here this manuscript details measurements of the anisotropic light-output response of trans-stilbene, henceforth referred to as stilbene, along the three primary crystal planes and analyzes how this anisotropic response impacts neutron image reconstruction in a handheld dual particle imager (H2DPI). A prototype H2DPI composed of stilbene pillars (6 x 6 x 50 mm 3 ) coupled to silicon photomultipliers was built and is capable of imaging both fast neutrons and gamma rays from kilogram quantities of special nuclear material. Stilbene was chosen as the scintillating medium for the imager because of its pulse shape discrimination capability, time resolution and relatively high light output. A drawback to using stilbene, however, is the anisotropic response. A recoiling proton from a neutron elastic-scattering event in stilbene will yield different amounts of scintillation light depending on the direction of the recoiling proton with respect to the crystal lattice. This manuscript analyzes how this anisotropic response impacts neutron image reconstruction in 4π. The light output in the three primary crystal planes of stilbene were independently measured 6–7 times for proton recoil energies ranging from 0.5–5.0 MeV using a quasi-monoenergetic time-of-flight neutron source. The measured light-output data in the three crystal planes were fit with a semi-empirical function based on Birks’ formula. These fits were used to reconstruct the location of a 252 Cf source in front of the imager (0°, -0.8°), to the left of the imager (-90°, -0.8°) and directly above the imager (0°, 90°) to determine if it is necessary to apply the directionally-dependent response of stilbene to accurately reconstruct source locations. A bootstrapping technique was applied to the measured data sets to produce 1000 images composed of 2000 cone projections for each source location and each measured light-output curve. List-mode maximum likelihood expectation maximization was applied to each image; the highest pixel location and the full width at half maximum (FWHM) were then recorded. The average and standard deviations of these parameters were taken for each set of images. The maximum difference in the average azimuthal pixel location when varying between the appropriate and incorrect light-output curves for the source locations at (0°, -0.8°) and (-90°, -0.8°) were respectively found to be 1.85 ± 1.39° and 2.03 ± 1.78°. All other pixel locations and FWHMs were within a single standard deviation of uncertainty. Taken together, the anisotropic response of stilbene has negligible impact on the neutron image reconstruction capability of the H2DPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic glass scintillator bars with dual-ended readout

Organic glass scintillator (OGS) bars (6 × 6 × 50 mm 3 ) were melt-cast and characterized with dual-ended readout by silicon photomultiplier arrays. The results were compared to trans-stilbene bars of the same size. Energy resolution was measured via a 137 Cs Compton-coincidence experiment. Time resolution was determined via a 22 Na coincidence-timing experiment. Depth-of-interaction resolution was measured by moving a gamma ray fan beam along the major axis of the bars. Pulse shape discrimination capability and neutron light output were determined via a time-of-flight measurement of a 252 Cf source. The OGS bars exhibited better energy resolution at 478 keV (10.3 ± 0.5% vs. 11.2 ± 0.5%), better time resolution from 200–341 keVee (270 ps vs. 340 ps FWHM), slightly poorer depth-of-interaction resolution, poorer PSD performance, and higher neutron light output than the stilbene bars. Here, the low cost, ease of manufacturing, brightness, and excellent time resolution make OGS a strong candidate for use in compact radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗