Saving Energy, Saving Money [Slides]
Make sure you have CO detectors installed; Test batteries regularly; Have your furnace serviced annually; Don’t use grills or generators indoors.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Make sure you have CO detectors installed; Test batteries regularly; Have your furnace serviced annually; Don’t use grills or generators indoors.
Decontaminated salt solution from Tank 50 at the Savannah River Site (SRS) is known to contain dissolved mercury species which are present as hydroxides and oxides. These species are reported in analytical measurements as the organic cation [CH 3 Hg] + and the inorganic cation Hg 2+ . The salt solution is mixed with cementitious reagents, blast-furnace slag (BFS) and thermally beneficiated Class F fly ash in the Saltstone Processing Facility and pumped into engineered Saltstone Disposal Units, (SDUs), to produce a solidified waste form. The solidified waste form, saltstone, encapsulates and chemically stabilizes the mercury and other contaminants, sequestering them from release into the environment. With the discovery of methylmercury in the salt solution, testing was performed to determine the extent to which saltstone prepared with methylmercury (MeHg) retains mercury in the Toxicity Characteristic Leaching Procedure (TCLP). Results from this testing indicated that the amount of mercury extracted remained below the regulatory limit, and that the saltstone formulation with a greater proportion of BFS performed slightly better at retaining Hg in the solid.
A fire occurred in a CEM MARS 6 analytical microwave during microwave-assisted, acid digestion of a soil sample in a Research and Development (R&D) laboratory. The soil sample had been pretreated at 550°C for approximately 4 hours in a furnace prior to digesting in the microwave. Less than 1-gram aliquots of the pretreated soil sample were placed into separate microwave reaction vessels along with an acid mixture used for digestion. The microwave was used to facilitate digestion of the samples. Microwave reaction vessels were loaded with acid and soil samples, sealed in cassettes, and the cassettes placed onto a microwave carousel. A temperature probe that senses the reaction temperature during the run was inserted into the Reference Cell thermowell. The contents of the Reference Cell were identical to the contents of the other reaction cells. The researcher initiated the run and then left the laboratory to perform other work. Upon returning to check the digestion run, flames and smoke were observed originating from the microwave. The researcher exited the lab, immediate emergency actions were taken, and the local fire department responded and extinguished the fire. No personnel were injured, and no facility structural damage occurred. The affected microwave is a total loss. The fire investigation revealed the most credible cause of the fire is an incompatible temperature probe that did not accurately measure temperature of the liquid phase of the Reference sample.
The focus of this project was to observe and simulate the solidification of uranium metal at the crystallographic level from its molten state. Melting experiments were conducted at two different scales to observe microstructural evolution using either a laboratory-scale induction furnace (hundreds of grams of metal) or a microscope heating stage (hundreds of milligrams of metal), respectively. Experimental parameters and characterization data were then used to inform a phase field model of gamma-U crystal growth as dendrites with or without secondary phase impurities in the form of uranium carbide particles. Finally, training datasets were generated by the phase field model as inputs to a neural network, developed with the aim of providing a faster, cheaper surrogate model for microstructural simulations within a given parameter space. Progress is reported herein for each of these task areas. Ultimately, 1) an optical microscope heating stage capability has been stood-up for uranium metal solidification studies, 2) a phase field model was advanced to simulate multiple uranium grains growing in the presence of carbide impurity particles and 3) a neural network was constructed and optimized to predict the microstructure features of individually growing uranium crystals.
Savannah River National Laboratory is developing a separations flowsheet for the recovery of valuable elements from irradiated 242 Pu targets. The primary impetus for this effort is to recover the rich amount of 244 Pu contained in the targets, however, the targets also contain other valuable isotopes such as heavy Cm and 241,243 Am. DGA Resin, developed by Eichrom Technologies Inc., was selected to recover these materials from the 7 – 9 M HNO 3 matrix raffinate of the anion exchange process used to separate Pu. The resin has a high affinity for trivalent actinides and rare earth elements (REEs) in moderate to strong nitric acid. After loading the resin, the extracted materials (including Cm and Am) are to be recovered as oxides in a two-step process by thermally drying and reducing the mass and volume of the resin in the process column followed by calcination of the resultant residue. It is desirable to reduce the amount of residual HNO 3 in the resin bed prior to these furnace operations, but the reduced acid concentration is known to lower the distribution coefficients of the components of interest to the extractant. The purpose of this study was to validate the loading capacity of the resin and determine losses to be expected from rinsing the loaded resin with dilute HNO 3 .
This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.
This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.
This presentation will report the rational design and fabrication of NETL’s highly permeable non-aging thin film composite (TFC) membranes for CO2 capture from various industrial point sources. This talk will also cover the design, computational fluid dynamic simulation, 3D printing, and permeation testing of plate-and-frame membrane modules for an upcoming field demonstration at U. S. Steel’s Edgar Thomson Plant in Braddock, PA. The field test will demonstrate membrane-based CO2 capture from a blast furnace for decarbonization of steel manufacturing for the first time in the U.S. A mobile gas permeation test unit is currently under design and construction for the field test, which is scheduled to take place in 2025.
GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.
In support of performing follow on irradiation experiments with previously irradiated materials, the Halden Reactor Project developed unique and state of the art capabilities to refabricate and re-instrument previously irradiated materials. Such materials were used in in-pile tests at the Halden reactor, and out-of-pile tests for example using furnaces as a heat source. The decision to close the Halden Reactor Project results in the loss of this refabrication and reinstrumentation capability. As a result, the United States Department of Energy has determined to develop refabrication and re-instrumentation capability at the unique shielded facilities at Idaho National Laboratory. The development of refabrication capability has been completed and demonstrated. This report focuses on the complementary aspects of re-instrumentation and the progress to date. Halden spent nearly 30 years developing both refabrication and reinstrumentation. Collaboration with Halden is allowing INL to develop this capability much more rapidly. The results include development of the capability to drill annular center holes in ceramic UO2 fuel pellets, development of fuel rod end caps with feedthroughs for centerline instrumentation inside the rodlet, The procurement of both fuel drilling and welding demonstration equipment from Halden, evaluation of surface thermocouple attachments to support better understanding of temperature measurement uncertainties, and finally, the conceptual design of a new shielded enclosure where advanced refabrication and re-instrumentation equipment can be housed. The authors would like to thank the numerous colleagues at INL and Halden who provided support in accomplishing this work. Their support both material and intellectual is invaluable in advancing the state of the art and establishing the capabilities for refabrication and re-instrumentation at INL.
Development towards the various realizations of the FCC machine requires optimization of sub-GHz elliptical cavities for high-gradient and high-Q operation, both in pulsed and CW mode, for application in the booster and collider portions. Previous development work validated the proposed 800 MHz 5-cell elliptical RF design, showing reasonable performance after EP treatment. However, the stringent high-Q (3.8e+10) and high-gradient (24 MV/m) goals of the FCC machine cavities will require further development, relying on advanced surface processing techniques developed at 1.3 GHz, such as medium-temperature furnace baking. We describe the development and preparation of 1- and 5- cell 800 MHz cavities for the high-Q program. In parallel, we discuss the design progress and strategies for integrating the 800 MHz cavities into cryomodules to be implemented in both the booster and collider rings.
The performance of superconducting radiofrequency (SRF) cavities is critical to enabling the next generation of efficient high-energy particle accelerators. Recent developments have focused on altering the surface impurity profile through \textit{in-situ} baking, furnace baking, and doping to introduce and diffuse beneficial impurities such as nitrogen, oxygen, and carbon. However, the precise role and properties of each impurity are not well understood. In this work, we attempt to disentangle the role of nitrogen and oxygen impurities through time-of-flight secondary ion mass spectrometry of niobium samples baked at temperatures varying from 75-800 $^\circ$C with and without nitrogen injection. From these results, we developed treatments recipe that decouple the effects of oxygen and nitrogen in doping treatments. Understanding how these impurities and their underlying mechanisms drive further optimization in the tailoring of impurity profiles for high-performance SRF cavities.
This report presents the testing results of rhodium-based self-powered neutron detectors (Rh-SPND) irradiated in a furnace dry tube from ambient temperature to 850°C at the Ohio State University Research Reactor. The purpose of the experiment is to demonstrate the technique and application of a temperature compensation technique for the Rh-SPND. This is performed by characterizing the temperature effects observed in past experiments—a displacement current and a stabilized dark current—of the Rh-SPND as a function of temperature under the models of shifting space charges as a product of photoconductivity properties. Low-power irradiation at the OSURR was performed with stabilized temperatures of ambient, 550, 575, 600, 625, 650, 675, and 700°C were first performed to obtain the curve fit parameters that describes the temperature effects. The results provided further insight for the behavior of the SPND at high temperatures in accordance with available insulation conductivity models. Transition points from photoconductivity to ionic conductivity were identified in the range of 550–600°C. Additionally, transition points ionic to electric conductivity were observed in the range of 675–700°C, however, the data was not able to fully capture the transition and did not have enough resolution to provide predictive compensation based only on temperature readings.
DayLyte Batteries is developing an aqueous Sodium-Air battery made with abundant materials while being half to a third the weight of Li-ion to power electric aircraft, electric vehicles and provide renewable energy on demand. To make this battery practical, DayLyte is developing a thin film ceramic Nasicon solid electrolyte amenable to rapid scaleup as well as a protective coating that will protect the solid electrolyte from 50wt% NaOH during the battery’s end-of-discharge while still allowing Na-ions to pass back and forth. If the thin film solid electrolyte and stable coating can be developed it will open the world to step change in battery performance all while not sacrificing the environment on the way. The project was designed to first focus on making and characterizing the Nasicon membrane followed by measuring its electrochemical performance, then assembling a full cell, optimizing its NaOH stability and then optimize the overall prototype design. Over the past two years, we have significantly improved the Nasicon film uniformity, demonstrated protective ligands that are stable in 50wt% NaOH by measuring no mass change with a quartz crystal microbalance, tested different heating methods like tube furnace and rapid heating and developed glassy carbon coatings on the current collector to prevent Nasicon-current collector alloying. We have found that getting film uniformity as measured by electrochemical impedance spectroscopy (EIS) is difficult because of different factors like surface roughness, deposition uniformity and heat treatment time and uniformity. The glassy carbon coating should significantly reduce the surface roughness and by tuning the coating conditions the film deposition uniformity improves and using an automated heating method should lead to much improved film uniformity.
This report serves to present the evaluation results of commercial radiation detectors (SPNDs) with the potential to accomplish the data objectives—having sufficient gamma and fast neutron sensitivity—at temperatures near 650°C. The detectors chosen for evaluation are gamma ion chambers from Exosens (previously known as Photonis) models CRGA11 and CRGE32 and tantalum-based self-powered neutron detectors (Ta-SPND) from Mirion. The evaluation was performed in a series of heat irradiations from ambient to 850°C in the 9.5-inch dry tube furnace at the Ohio State University Research Reactor (OSURR). Ion chamber counting curves were measured to evaluate sensor operability at temperature. Detector sensitivity to reactor power and temperature were measured and presented in curve fit parameters. The curve fit equations were used to identify the suggested operational temperatures based on reactor power. Overall, it was evaluated that the CRGA11 was not significantly affected by temperatures up to 650°C and is operable—with higher temperature-contributed signals—up to 700°C. The CRGE32 was more affected by the high temperatures compared to the CRGA11. As a result of increasing temperature, the leakage current was a dominating factor. While the detector can operate up to 600°C and 700°C with lowered high voltage, it is not recommended unless a suitably strong gamma flux field is present. Finally, Ta SPND did not demonstrate good performance beyond 350°C due to the presence of an unknown phenomenon at changing temperatures. The study of the phenomenon is an active research topic outside the scope of this project.
In the era of modern computing, quantum bits (or qubits) are extensively researched due to their ability to perform computations exponentially faster than classical computers. One promising method for synthesizing qubits on a macroscopic scale is through superconductor diodes (SDs). Unfortunately, SDs are currently limited by their dependence on extremely low temperatures (T ≈ 0K), which restricts their practical usability at larger scales. To address this limitation, researchers are exploring new materials and methods to identify superconductors with higher critical temperatures. My research at the Lawrence Livermore National Laboratory (LLNL) focuses on synthesizing and characterizing superconductor diodes to determine their efficiency for quantum computing applications. Bismuth thin films were synthesized with magnetron sputtering with separate thicknesses which provides information on methods to alter their resistivity. Bismuth was characterized as the topological insulator used in the diode, and its resistivity was measured using a standard four-point probe technique with 1 mA current. Bismuth (99.99% pure) was then purified in a tubular furnace at 400C to use within a Josephson junction as a topological insulator. Niobium and Tantalum Josephson junctions were then synthesized, and they were characterized using a lock-in amplifier four-point probe technique. Materials such as niobium and tantalum are used in high-entropy alloy research, which is a relatively new class of material that has little research within the superconductor diode community, yet the current research shows promise. We anticipate that testing high-entropy superconductors will reveal crucial factors, potentially leading to the development of high-temperature superconductors in the future.
The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.
This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.