Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Large scale polymer toughening of two-dimensional materials revealed by in situ TEM fracture tests and multiscale simulations

Two-dimensional (2D) materials offer significant potential for applications in energy-harvesting devices, batteries, sensors, and transistors. However, their intrinsic brittleness makes them prone to mechanical failure, limiting their practical use. In this work, we perform in situ transmission electron microscopy (TEM) fracture tests on monolayer MoSe2 and uncover an extrinsic toughening effect induced by an ultrathin adsorbed polystyrene adlayer. This adlayer substantially enhances the fracture resistance of the 2D flakes. Through a combination of molecular dynamics simulations and finite element analysis, we elucidate the molecular mechanism behind this toughening effect. Further, it arises from the active crack-bridging behavior of entangled polymer chains and the formation of a fracture process zone that stabilizes crack propagation and increases the energy required for crack extension. The proposed toughening mechanism offers a pathway to improving the mechanical reliability of 2D material-based devices by mitigating the risk of sudden failure.

2D materials↗

Mechanical Properties of Functionally Graded Concrete Lining for Deep Underground Structures

With the mining depth of coal resources increasing, the thickness of traditional lining for deep mines becomes large. The bearing capacity of the outer lining cannot be fully utilized, so a new type of functionally graded lining structure (FGL) with radial Young’s modulus varying in gradient is proposed. In this study, through theoretical analysis and numerical simulation, the mechanical properties of the functionally graded lining were studied, including the characteristics of the elastic working state and the ultimate bearing state. The influences of the structural parameters of the functionally graded lining, including the inner radius, the thickness, Young’s modulus, the compressive strength of the concrete, Poisson’s ratio, and the number of layers on the mechanical properties were analyzed. The calculation formula of the ultimate bearing capacity of the lining and the calculation formula of the maximum tangential strain at the time of lining failure were put forward. The accuracy of the formula was verified by comparing with the numerical simulation results. The research results provide the basis for the construction of the design theory of a functionally graded lining structure and have great engineering significance for the construction of the kilometer-deep mines in the future.

Li, De-Chun↗

Comparison of AMZIRC and GRCop-84

The mechanical properties of two copper alloys with high thermal conductivity, GRCop-84 and AMZIRC, were compared. These are competing alloys in high temperature, high heat flux applications such as rocket nozzles. The GRCop-84 data presented was taken from previous work. The results of new tensile, creep, and compression tests on AMZIRC are presented. Tests were done on as-received hard drawn material, and on material that had been subjected to a heat treatment designed to simulate a brazing operation at 935 C. As-received AMZIRC was found to have excellent properties at temperatures below 550 C, with room temperature yield and ultimate tensile strengths of about 500 MPa, and ductile failures. By comparison, GRCop-84 s room temperature tensile yield and ultimate strengths are about 200 and 380 MPa respectively. However, the simulated brazing heat treatment substantially decreased the mechanical properties of AMZIRC; and the strength of as-received AMZIRC dropped precipitously as test temperatures exceeded 500 C. The properties of GRCop-84 were not significantly affected by the 935 C heat treatment. As a result, there appear to be advantages to GRCop- 84 over AMZIRC if use or processing temperatures of greater than 500 C are expected. Tensile creep tests were done at 500 and 650 C. At these temperatures, the creep properties of GRCop-84 were superior to AMZIRC s. At equivalent rupture life and stress, GRCop-84 was found to have a 150 C temperature advantage over AMZIRC; for equivalent rupture life and temperature GRCop-84 was two times stronger.

de Groh, Henry C. III↗

Lunar Simulant Deposition Technique for Dust Tolerance Studies

A renewed interest in lunar exploration has spawned an array of development efforts for lunar surface assets. These systems depend on the reliable operation of mechanisms and components that may be susceptible to performance degradations or failure due to dust. The Uniform Dust Deposition System was developed at the NASA Glenn Research Center to provide repeatable, uniform, and automated deposition of simulants on surfaces of interest for dust mitigation testing. The system is capable of depositing simulants on test articles up to 60 cm in diameter and 15 cm high in a dry air environment with less than 1 percent relative humidity while keeping users safe from aerosolized dust. The automation of the system allows for high testing throughput while not sacrificing test quality and allows the user to reduce data in parallel. The additional development of a simulant preparation technique complements the repeatability of the deposition physics during testing. The system includes an imaging subsystem that leverages the power of machine learning to count simulant particles and measure their size, thereby allowing for accurate predictions of surface deposition densities (coefficient of determination R^(2) = 0.93) from images alone. The coverage of dust on a surface was shown to be uniform (coefficient of variation CV < 0.11), allowing developers to accurately evaluate the performance of their technology with a prescribed amount of lunar simulant, information that can be used to develop and refine models. The accuracy of the system is currently less than desired for a single deposition run, with a standard deviation (SD) ranging from 18 to 24 mg, or 0.839 to 1.184 mg/sq. cm , for a 5-cm-diameter area. However, the accuracy can be improved by performing multiple deposition runs to build dust to a desired level. Testing has shown that a SD of 0.2 to 0.6 mg, or 0.076 to 0.227 mg/sq. cm, can be achieved for a 5-cm-diameter area using this technique.

Stephen Gerdts↗

Strength distributions of laminated FeNi-based metal amorphous nanocomposite ribbons

Metal Amorphous Nanocomposite (MANC) materials offer low losses at high magnetic switching frequency, enabling high power density motors with increased rotational speed. While MANCs have high strength, they are brittle. The use of motor components such as a rotor consisting of brittle material presents a reliability concern. Here, a promising MANC alloy is subjected to tensile tests and failure is observed with high-speed photography. A method is developed to prepare tensile specimens of laminated MANC and epoxy layers, simulating the stacking of an epoxy-impregnated tape-wound core. Tensile tests are conducted for single layer ribbon and for five- and ten-layer stacks of laminated material with thin layers of thermosetting epoxy. Failure distributions are shown to have increasing Weibull modulus with increasing layer count. The composite MANC material system is modeled using chain-of-bundles models. Using a k-failure model, we show that single ribbon strength distribution data can be used to predict well the failure distribution of laminated stacks. The agreement occurs when the assumed ineffective length, over which load is recovered in a failed layer, is comparable to the observed interlaminar separation length.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Arctic Amplification in the Community Earth System Models (CESM1 and CESM2)

We compare the Arctic amplification (AA) produced by the two Community Earth System Models CESM1 and CESM2, members of the CEMIP5 (Coupled Models Intercomparison Project phase 5) and CEMIP6 collections, respectively. We find that the CESM1 model reproduces the recent high values of the AA deduced from the observed temperature much better than the CESM2. The correlation coefficient within the 1970–2012 time period between CESM1-simulated AA and the observed one is 0.47, while the CESM2 simulation leads to an anticorrelation of r = –0.53. Even the more successful model (CESM1) is not able to reproduce recent high AA values of 4–5. The main cause of this failure is the model’s overestimate of the rate of increase in the mean global temperature in years post 1990. When the CESM1 model’s simulated trend of the mean global temperature is replaced in the expression for the AA by the observed temperature trend, the correlation coefficient increases from 0.47 to 0.75. The CESM1 model is among the best north American models in AA simulation while the CESM2 model is among the least successful.

54 ENVIRONMENTAL SCIENCES↗

Model predictive control of KSTAR equilibrium parameters enabled by TRANSP

Due to the complex behavior of tokamak plasmas and the importance of optimizing performance while avoiding instabilities and machine limits, plasma control algorithms are becoming increasingly dependent on sophisticated model-based control approaches. It is anticipated that the use of integrated modeling codes in the model-based control design process will reduce the amount of experimental time needed to implement new control algorithms by facilitating development of control-oriented models and enabling higher-fidelity closed-loop simulations. In this work, a reduced model is developed from a series of TRANSP simulations and is used to develop a model predictive control (MPC) algorithm for controlling important equilibrium parameters in KSTAR [1] discharges. The control algorithm uses the KSTAR neutral beam injection system and the target plasma current and plasma boundary as actuators, and optimizes the plasma stored energy, loop voltage, and internal inductance while avoiding constraints that could lead to disruptions. Higher fidelity testing of the control algorithm is performed using a flexible framework for enabling external processes to actively control plasma parameters in TRANSP simulations. Furthermore, closed-loop simulations demonstrate the ability of the control algorithm to respond to disturbances in density and confinement, handle actuator failures, and move the discharge to high non-inductive fraction conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A workflow to assess the efficacy of brine extraction for managing injection-induced seismicity potential using data from a CO 2 injection site near Decatur, Illinois

Injection of CO 2 for storage in a geologic formation increases pore pressure and alters in situ stresses. Depending on the orientation of any existing fault and fracture planes, such as critically stressed planes, this stress alteration will modify normal stresses acting on planes and could result in frictional sliding and release stored energy in the form of seismicity. Brine extraction (BE) is a technique that can be applied prior to, or during, CO 2 injection to reduce pore pressure for increasing storage capacity and, potentially, for reducing the likelihood of frictional sliding. Here a workflow is described to assess the efficacy of BE for mitigating frictional sliding (i.e., seismicity) during injection and entails: site characterization, stress calculations and failure assessment, static and dynamic modeling, and BE operational planning. Site characterization describes the stress field used to calculate the Coulomb Failure Function (CFF) that constrains allowable pore pressure changes and injection rates in the numerical simulation of CO 2 injection scenarios. The inclusion of BE in the workflow allows for determination of the potential need for pressure reduction, and evaluation of the effectiveness of this operation. Example application of the workflow using an injection field dataset near Decatur, IL, provides insight on fracture planes and stresses at the site, formation properties and the impact of variable CO 2 injection-rate targets on whether BE plans are required. The study workflow indicates that BE could enhance CO 2 injection rate by 39% and correspondingly reduce the potential for injection-induced seismicity as indicated by a reduction in CFF.

58 GEOSCIENCES↗

Impact Damage and Strain Rate Effects for Toughened Epoxy Composite Structures

Structural integrity of composite systems under dynamic impact loading is investigated herein. The GENOA virtual testing software environment is used to implement the effects of dynamic loading on fracture progression and damage tolerance. Combinations of graphite and glass fibers with a toughened epoxy matrix are investigated. The effect of a ceramic coating for the absorption of impact energy is also included. Impact and post impact simulations include verification and prediction of (1) Load and Impact Energy, (2) Impact Damage Size, (3) Maximum Impact Peak Load, (4) Residual Strength, (5) Maximum Displacement, (6) Contribution of Failure Modes to Failure Mechanisms, (7) Prediction of Impact Load Versus Time, and (8) Damage, and Fracture Pattern. A computer model is utilized for the assessment of structural response, progressive fracture, and defect/damage tolerance characteristics. Results show the damage progression sequence and the changes in the structural response characteristics due to dynamic impact. The fundamental premise of computational simulation is that the complete evaluation of composite fracture requires an assessment of ply and subply level damage/fracture processes as the structure is subjected to loads. Simulation results for the graphite/epoxy composite were compared with the impact and tension failure test data, correlation and verification was obtained that included: (1) impact energy, (2) damage size, (3) maximum impact peak load, (4) residual strength, (5) maximum displacement, and (6) failure mechanisms of the composite structure.

Chamis, Christos C.↗

Simulation evaluation of the control system command monitoring concept for the NASA V/STOL research aircraft (VSRA)

A control-system monitoring concept is described that has the potential of rapidly detecting computer command failures (hardware or software) in fly-by-wire control systems. The concept has been successfully tested on the NASA Vertical/Short Takeoff and Landing Research Aircraft (VSRA) in the Ames Research Center's Vertical Motion Simulator. The test was particularly stringent, since the VSRA is required to operate in a hazardous environment. The fidelity of the aircraft model used in the simulation was verified by flying both the simulated and actual aircraft in a precision hover task using specially designed targets.

Schroeder, J. A.↗

Certification and prediction of post-disturbance states in dynamic security assessment

Dynamic security assessment usually involves the simulation of system dynamics under large disturbances. The instant large disturbance occurs, the post-disturbance state of the system could deviate significantly from the pre-disturbance one. It is desirable and necessary to develop an efficient method to certify the existence of state and predict the approximate post-disturbance state because: (1) faster warning can be made in online assessment; and (2) the dynamic simulator can be given better initial values to calculate precise solutions, which prevents convergence failure brought on by poor initial values. We propose a novel approach for efficiently certifying and predicting the post-disturbance states in dynamic security assessment. Based on the fixed-point power flow mapping approach applied to salient pole generator models, the criterion for determining the existence and uniqueness of the post-disturbance solution is derived, and the bounds of post-disturbance solution can be rigorously characterized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of toolpath in large-format additive manufacturing with bio-derived composites

There has been growing interest in integrating bio-derived composites into Large-format additive manufacturing (LFAM) feedstocks to reduce the use of petroleum-derived materials and reduce the overall carbon footprint of LFAM. However, these materials present unique challenges during manufacturing due to their variability, which can lead to unintended deformations and failures attributable to suboptimal process conditions. While numerical modelling has been extensively employed to simulate numerous manufacturing processes, its application in LFAM with bio-derived composites remains limited. This study addresses this gap by systematically developing a numerical model to simulate the LFAM process using bio-based materials, specifically wood fiber-reinforced polylactic acid (PLA/WF). Experimental investigations were conducted to characterise the thermal and mechanical properties of additively manufactured PLA/WF specimens. Numerical simulations were performed to predict temperature profiles and deformations during LFAM. The effect of varying infill patterns, internal structures, and tool paths on the temperature distribution and deformation of printed parts was explored using the developed model. This article aims to advance the utilisation of bio-derived composites in LFAM systems and provide a comprehensive understanding of the LFAM process. The findings offer valuable insights for optimising process parameters and enhancing the performance of LFAM with bio-based composites.

Large-format additive manufacturing↗

A Scalable PDC Placement Technique for Fast and Resilient Monitoring of Large Power Grids

The wide-area measurement system (WAMS) is a key enabler of real-time monitoring of power grids. The essential goals of WAMS design are fast and resilient data transfer from phasor measurement units (PMU) to phasor data concentrators (PDC). We propose a scalable two-stage PDC placement technique for minimizing the end-to-end delay while maintaining resiliency. In the prescreening stage, the plausible candidates of PDC configurations are identified based on a graph theory-based multi-median function (MMF). Here, in this article, a computationally efficient meta-heuristic algorithm is used to address scalability. In the candidate selection stage, two different algorithms, namely, Suurballe's and Dijkstra's, are employed to identify the best of those plausible PDC configurations as the final design. This technique not only minimizes the hop paths between PMUs and PDCs, but also ensures network resiliency against single PMU, PDC, or communication link failure by incorporating the roles of PMUs in power grid observability into routing policy. Simulation results on the IEEE 57-bus test power system and the 2000-bus test power system demonstrate the effectiveness and scalability of the proposed technique.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ORNL Input to GDSA Repository Systems Analysis FY21

This document satisfies the M3 milestone M3SF-21OR010304082 titled “ORNL Input to GDSA Repository Systems.” This document describes the current status of Oak Ridge National Laboratory’s (ORNL’s) efforts related to analyses of dual-purpose canister (DPC) disposal in unsaturated alluvium with a focus on thermal hydrological constraints on criticality timing and power output. This analysis updates previous analyses of thermal hydrological constraints on timing and power output of a potential criticality event in Dual-Purpose Canisters (DPCs) in a hypothetical repository in unsaturated alluvium using a more realistic representation of heat transport inside dry DPCs. PFLOTRAN was used for the simulations of multiphase thermal hydrology near a single DPC. The scenario considers a DPC failure at 9000 years, allowing water to enter and eventually fill the DPC. Once the DPC is filled to a level that could support a criticality event, different values for criticality power output were added to the decay heat. The main objective is to bound the power output that could be produced by a criticality event without driving water out of the package. For the conditions analyzed here, following a package breach, the alluvial formation could supply enough water to allow enough accumulation in the DPC to support a criticality event. However, the power output that would be generated is limited to modest values by loss of water moderator due to evaporation and vapor diffusion. In the reference case scenario, the DPC would not start to fill with water until about 16,000 years post closure and would not fill to a level that allows a criticality event until approximately 25,000 years post closure. The long-term average power output that could be sustained without driving off the water and terminating the criticality event is limited to approximately 100 W. Sensitivity to assumed conditions and parameters in the reference case, especially the deep percolation rate, need to be addressed but could not be undertaken because of numerical failures of the PFLOTRAN code running in general mode in the dry conditions of an unsaturated alluvium repository

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Description and simulation of an integrated power and attitude control system concept for space-vehicle application

An Integrated Power and Attitude Control System (IPACS) concept with potential application to a broad class of space missions is discussed. A description is given of the basic concept of combining the onboard energy storage and attitude control functions by storing energy in spinning flywheels which are used to provide control torques. A shuttle-launched Research and Applications Module (RAM) A303B solar-observatory mission having stringent pointing requirements (1.0 arc second) is selected to investigate possible interactions between energy storage and attitude control. A simulation of this spacecraft involving actual laboratory-model control-system hardware is presented. Simulation results are discussed which indicate that the IPACS concept, even in a failure-mode configuration, can readily meet the RAM A303B pointing requirements.

Will, R. W.↗

Performance and economic risk evaluation of dispersed solar thermal power systems by Monte Carlo simulation

A preliminary comparative evaluation of dispersed solar thermal power plants utilizing advanced technologies available in 1985-2000 time frame is under way at JPL. The solar power plants of 50 KWe to 10 MWe size are equipped with two axis tracking parabolic dish concentrator systems operating at temperatures in excess of 1000 F. The energy conversion schemes under consideration include advanced steam, open and closed cycle gas turbines, stirling, and combined cycle. The energy storage systems include advanced batteries, liquid metal, and chemical. This paper outlines a simple methodology for a probabilistic assessment of such systems. Sources of uncertainty in the development of advanced systems are identified, and a computer Monte Carlo simulation is exercised to permit an analysis of the tradeoffs of the risk of failure versus the potential for large gains. Frequency distribution of energy cost for several alternatives are presented.

Manvi, R.↗

Software models: A Bayesian approach to parameter estimation in the Jelenski-Moranda software reliability model

Maximum likelihood estimation procedures for the Jelinski-Moranda software reliability model often give misleading answers. A reparameterization and a Bayesian analysis eliminate some of the problems incurred by MLE methods and often give better predictions on sets of real and simulated data. Practical difficulties in estimating the initial number of errors N and the failure rate of each error phi by the method of maximum likelihood are: N, the MLE of N, is occasionally infinite (i.e., the routines for calculating N and phi do not converge). It is shown that N is finite sub i only if the regression line of the interevent times t sub i vs. i has positive slope. A serious problem is that often N approximates n, the sample size, and sometimes N = n. Thus the MLE predicts that the program is perfect even when it is far from being so. Only when almost all failures have been removed can N and phi be trusted near the end of debugging.

Littlewood, B.↗

User's manual for a computer program for the emulation/simulation of a space station Environmental Control and Life Support System (ESCM)

This manual describes how to use the Emulation Simulation Computer Model (ESCM). Based on G189A, ESCM computes the transient performance of a Space Station atmospheric revitalization subsystem (ARS) with CO2 removal provided by a solid amine water desorbed subsystem called SAWD. Many performance parameters are computed some of which are cabin CO2 partial pressure, relative humidity, temperature, O2 partial pressure, and dew point. The program allows the user to simulate various possible combinations of man loading, metabolic profiles, cabin volumes and certain hypothesized failures that could occur.

Yanosy, James L.↗