Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Direct Writing of X-ray Gratings Using Zone-Plate-Array Lithography (ZPAL)

With the objective of providing the synchrotron and free-electron-laser communities with rapid turnaround and low prices for the highest quality and most advanced gratings and diffractive-focusing optics, LumArray has made specific improvements to its ZP-150 maskless photolithography system, which is based on Zone-Plate-Array Lithography (ZPAL), a technology unique to Lumarray. ZPAL’s advantages include an ability to correct in software for systematic patterning errors. Emphasis was placed on interferometric measurements of various contributors to patterning errors using Fizeau interferometry and a Mireau technique that was developed specifically for measuring errors within a micron-scale area. Average line-placement error was reduced below 20 nm using both pattern-file distortion and address-grid modification. The preferred implementation, address-grid modification, is hardware-based and requires no user intervention while also correcting more types of error. With continued iteration and refinement of the error measurements, we anticipate achieving global line-placement error below10nm. In order to investigate line-edge smoothness and high-frequency line-placement errors, a scheme for inspecting micron-sized areas was invented and implemented based on Mireau interferometry. This enabled the various contributions to be separately evaluated and measured. These included: exposure-dose variation, pattern-writing strategy and errors in the positioning of the microlenses. Deleterious crosstalk between microlenses was minimized via a pattern-dependent software modification. The impact of exposure threshold was revealed and adjustment made. The impact of address-grid fineness on line-edge roughness was likewise shown. Lastly, techniques were developed to measure and correct errors in the positioning of microlenses within the array. We expect final calibration of microlens positions to within 5nm.

42 ENGINEERING↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On Compatible Transfer Operators in Nonsymmetric Algebraic Multigrid

The standard goal for an effective algebraic multigrid (AMG) algorithm is to develop relaxation and coarse-grid correction schemes that attenuate complementary error modes. In the nonsymmetric setting, coarse-grid correction Π will almost certainly be nonorthogonal (and divergent) in any known standard product, meaning ∥Π∥ > 1. This introduces a new consideration, that one wants coarse-grid correction to be as close to orthogonal as possible, in an appropriate norm. In addition, due to nonorthogonality, Π may actually amplify certain error modes that are in the range of interpolation. Relaxation must then not only be complementary to interpolation, but also rapidly eliminate any error amplified by the nonorthogonal correction, or the algorithm may diverge. Here this paper develops analytic formulae on how to construct “compatible” transfer operators in nonsymmetric AMG such that ∥Π∥ = 1 in some standard matrix-induced norm. Discussion is provided on different options for the norm in the nonsymmetric setting, the relation between “ideal” transfer operators in different norms, and insight into the convergence of nonsymmetric reduction-based AMG.

97 MATHEMATICS AND COMPUTING↗

Cone-Beam Computed Tomographic Image Guidance for Lung Cancer Radiation Therapy

Purpose: To determine the geometric accuracy of lung cancer radiotherapy using daily volumetric, cone-beam CT (CBCT) image guidance and online couch position adjustment. Methods and Materials: Initial setup accuracy using localization CBCT was analyzed in three lung cancer patient cohorts. The first (n = 19) involved patients with early-stage non-small-cell lung cancer (NSCLC) treated using stereotactic body radiotherapy (SBRT). The second (n = 48) and third groups (n = 20) involved patients with locally advanced NSCLC adjusted with manual and remote-controlled couch adjustment, respectively. For each group, the couch position was adjusted when positional discrepancies exceeded {+-}3 mm in any direction, with the remote-controlled couch correcting all three directions simultaneously. Adjustment accuracy was verified with a second CBCT. Population-based setup margins were derived from systematic ({sigma}) and random ({sigma}) positional errors for each group. Results: Localization imaging demonstrates that 3D positioning errors exceeding 5 mm occur in 54.5% of all delivered fractions. CBCT reduces these errors; post-correction {sigma} and {sigma} ranged from 1.2 to 1.9 mm for Group 1, with 82% of all fractions within {+-}3 mm. For Group 2, {sigma} and {sigma} ranged between 0.8 and 1.8 mm, with 76% of all treatment fractions within {+-}3 mm. For Group 3, the remote-controlled couch raised this to 84%, and {sigma} and {sigma} were reduced to 0.4 to 1.7 mm. For each group, the postcorrection setup margins were 4 to 6 mm, 3 to 4 mm, and 2 to 3 mm, respectively. Conclusions: Using IGRT, high geometric accuracy is achievable for NSCLC patients, potentially leading to reduced PTV margins, improved outcomes and empowering adaptive radiation therapy for lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-body potential model based on cosine series expansion for ionic materials

There is a method to construct a two-body potential model for ionic materials with a Fourier series basis and we examine it. For this method, the coefficients of cosine basis functions are uniquely determined by solving simultaneous linear equations to minimize the sum of weighted mean square errors in energy, force and stress, where first-principles calculation results are used as the reference data. As a validation test of the method, potential models for magnesium oxide are constructed. The mean square errors appropriately converge with respect to the truncation of the cosine series. This result mathematically indicates that the constructed potential model is sufficiently close to the one that is achieved with the non-truncated Fourier series and demonstrates that this potential virtually provides minimum error from the reference data within the two-body representation. The constructed potential models work appropriately in both molecular statics and dynamics simulations, especially if a two-step correction to revise errors expected in the reference data is performed, and the models clearly outperform two existing Buckingham potential models that were tested. Moreover, the good agreement over a broad range of energies and forces with first-principles calculations should enable the prediction of materials behavior away from equilibrium conditions, such as a system under irradiation.

36 MATERIALS SCIENCE↗

Investigating the Link Between Radiologists Gaze, Diagnostic Decision, and Image Content

Objective: To investigate machine learning for linking image content, human perception, cognition, and error in the diagnostic interpretation of mammograms. Methods: Gaze data and diagnostic decisions were collected from six radiologists who reviewed 20 screening mammograms while wearing a head-mounted eye-tracker. Texture analysis was performed in mammographic regions that attracted radiologists attention and in all abnormal regions. Machine learning algorithms were investigated to develop predictive models that link: (i) image content with gaze, (ii) image content and gaze with cognition, and (iii) image content, gaze, and cognition with diagnostic error. Both group-based and individualized models were explored. Results: By pooling the data from all radiologists machine learning produced highly accurate predictive models linking image content, gaze, cognition, and error. Merging radiologists gaze metrics and cognitive opinions with computer-extracted image features identified 59% of the radiologists diagnostic errors while confirming 96.2% of their correct diagnoses. The radiologists individual errors could be adequately predicted by modeling the behavior of their peers. However, personalized tuning appears to be beneficial in many cases to capture more accurately individual behavior. Conclusions: Machine learning algorithms combining image features with radiologists gaze data and diagnostic decisions can be effectively developed to recognize cognitive and perceptual errors associated with the diagnostic interpretation of mammograms.

Tourassi, Georgia↗

Correcting for Circumsolar and Near-Horizon Errors in Sky Cover Retrievals from Sky Images

Fractional sky cover amounts retrieved from sky imagery are overestimated significantly at times due to occurrences of “whitening” near the sun, and near the horizon for low sun, in the images. This phenomenon occurs due to forward scattering of visible light by aerosols and haze, and the intensity range limitations of the detectors of the cameras used to record the sky images. Our results suggest that when the problem occurs, the magnitude of the overestimate is typically on the order of about 10% to 20% fractional sky cover. To help alleviate this problem, a statistical analysis of the time series of the areas in the image near the sun position and along the horizon centered on the solar azimuth angle has been developed. This statistical analysis requires that images be captured frequently, at least once per minute. For times when the overestimation is detected as occurring, a correction is applied to the retrieved sky cover amounts. When the sky cover amount correction is applied, analysis indicates that the result better matches the actual sky conditions present, as noted by visual inspection of the sky images in question. In addition, frequency-of-occurrence histogram comparisons show that the adjusted results improve the agreement with other methodologies and expectations. Thus, the methodology presented here helps produce more accurate fractional sky cover retrievals.

54 ENVIRONMENTAL SCIENCES↗

Iterative Stress Reconstruction Algorithm to Estimate Three-Dimensional Residual Stress Fields in Manufactured Components

Residual stress (RS) significantly impacts the mechanical performance of components. Measurement of RS often provides incomplete data in terms of components of stress and spatial density. Employing such fields in finite element simulations results in significant modification of the field to achieve equilibrium and compatibility among strains. To overcome this, an iterative stress reconstruction algorithm (ISRA) is developed to estimate 3D RS fields that satisfy equilibrium, are stress component-wise complete, and represent the characterized data sampled. An Al 7075-T651 plate and an additively manufactured (AM) A36 steel wall are considered for RS reconstruction using measurement data from the literature. A maximum variation of ~2.5 MPa in the Al plate, and ~10 MPa in the steel wall are observed between the reconstructed and measured stresses. Furthermore, unknown stress components emerge and reach significant magnitudes (upto ~2.3 MPa in the Al plate and ~45 MPa in the AM wall) during ISRA. Indeed, it is found that minor errors in measurement or data processing are eliminated through the physical requirements during ISRA. Employing a reconstructed RS field is hence not just more accurate given its compatibility, but it additionally corrects for minor errors in measurement. Furthermore, it is found that spatially dense measurement data result in convergence with fewer iterations. Finally, although ISRA yields a nonunique solution dependent on boundary conditions, measurement errors, fitting errors, and mesh density, it accommodates for uncertainties and inaccuracies in measurement, as opposed to failing to reach a physically realistic converged solution.

42 ENGINEERING↗

STUDY OF CALIBRATION OF SOLAR RADIO SPECTROMETERS AND THE QUIET-SUN RADIO EMISSION

This work presents a systematic investigation of the influence of weather conditions on the calibration errors by using Gaussian fitness, least chi-square linear fitness, and wavelet transform to analyze the calibration coefficients from observations of the Chinese Solar Broadband Radio Spectrometers (at frequency bands of 1.0–2.0 GHz, 2.6–3.8 GHz, and 5.2–7.6 GHz) during 1997–2007. We found that calibration coefficients are influenced by the local air temperature. Considering the temperature correction, the calibration error will reduce by about 10%–20% at 2800 MHz. Based on the above investigation and the calibration corrections, we further study the radio emission of the quiet Sun by using an appropriate hybrid model of the quiet-Sun atmosphere. The results indicate that the numerical flux of the hybrid model is much closer to the observation flux than that of other ones.

79 ASTRONOMY AND ASTROPHYSICS↗

Parallax-corrected VISST-derived pixel-level products from satellite GOES-16

The NASA Langley group led by William Smith produced GOES-16 satellite cloud retrievals over an approximate 10 by 10 degree region over the CACTI field campaign location. These retrievals are described here: https://www.arm.gov/capabilities/vaps/visst and are available for download here . They use algorithms historically called VISST that are now referred to as SatCORPS. More information can be found in Trepte et al. (2019), Minnis et al. (2021), and Yost et al. (2021). If using this dataset, please cite these references, the CACTI VISST dataset DOI found at the download link above, and this dataset’s DOI. The CACTI VISST pixel-level retrievals are on a 2 km spatial grid and available every 15 minutes (every 10 minutes late in the campaign), producing 21,765 files for the entire field campaign between October 2018 and April 2019. They are not corrected for parallax error, which is an offset in the actual geographical location of a cloud above the surface due to the satellite viewing the cloud partly from the side off nadir. This dataset applies a correction for parallax using the location relative to the satellite and the retrieved cloud top height above the surface, which allows the dataset to be geo-located with surface-based observations. The parallax correction for each location depends on the longitude, latitude and cloud top height above ground level (AGL) for that longitude and latitude in the original VISST files. The cloud top height AGL requires first computing the surface elevation at each VISST grid point. Data from the Advanced Spaceborne Thermal Emission and Reflection (ASTER) Global Digital Elevation Map Version 3 at 30-m resolution is projected onto the VISST grid using conservative coarsening (conserving surface elevation) in the xESMF Python package. The surface elevation is then subtracted from the VISST-retrieved cloud top height above mean sea level. These cloud top heights AGL are then combined with longitude and latitude to estimate the latitude and longitude corrections. Due to variability in cloud top height, the parallax shifts produce an irregular grid of values since higher cloud tops are shifted further than lower cloud tops. A ball tree-based neighbor search with Haversine distance is performed using the Python-based scikit-learn library to find the nearest VISST grid point to each parallax correction-shifted point. The data value of the shifted point is then assigned to that VISST grid point. In this manner, the irregular geographical shifts to correct for parallax are projected back to the rectilinear VISST grid. Because relatively higher clouds should obscure lower clouds, the variable values for the highest cloud top are preferentially chosen if two or more values are assigned to a grid point. The parallax correction should be viewed as an improved but still imperfect estimation of the cloud top locations, largely because the cloud top height is an imperfect retrieval. Please see the attached README document for further information. Users are encouraged to contact the authors with any additional questions.

54 ENVIRONMENTAL SCIENCES↗

Linear Regression Systematics of the Q-weak Main Detector Asymmetry

The Q-weak collaboration has made the first direct measurement of the proton's weak charge at Jefferson Lab to tightly constrain new, parity-violating electron-quark interactions at the multi-TeV scale. Our experiment measured the ?200 ppb parity-violating asymmetry in the scattering of longitudinally polarized electrons from an unpolarized liquid hydrogen target at a luminosity of 1.8x10^39. Careful setup of the injector helped to suppress helicity correlated differences in beam position, angle, and energy which create false asymmetries due to changes in detector acceptance and the kinematic dependences of the e+p cross section. Measured differences in beam position were consistent among all 6 beam position monitors in front of the target, with a precision of ?1 nanometer. The size of corrections depends on the helicity correlated beam parameter differences, and averaged about 35 ppb per shift of data. The data were regressed using 10 different sets of Independent Variables. These were expected to give similar corrections yet showed differences at the +-10 ppb level. In this presentation I'll summarize how these different schemes have not only been helpful in understanding the sensitivities of the main detector but in assigning errors to the corrections.

Mack, David↗

Electronic structure calculations with the Tran-Blaha modified Becke-Johnson Density Functional

We report a series of calculations testing the predictions of the Tran-Blaha functional for the electronic structure and magnetic properties of condensed systems. We find a general improvement in the properties of semiconducting and insulating systems, relative to calculations with standard generalized gradient approximations, although this is not always by the same mechanism as other approaches such as the quasiparticle GW method. In ZnO the valence bands are narrowed and the band gap is increased to a value in much better agreement with experiment. The Zn d states do not move to higher binding energy as they do in local-density approximation+U calculations. The functional is effective for systems with hydride anions, where correcting self-interaction errors in the 1s state is important. Similarly, it correctly opens semiconducting gaps in the alkaline-earth hexaborides. It correctly stabilizes an antiferromagnetic insulating ground state for the undoped cuprate parent CaCuO{sub 2}, but seriously degrades the agreement with experiment for ferromagnetic Gd relative to the standard local-spin-density approximation and generalized gradient approximations. This is due to positioning of the minority-spin 4f states at too low an energy. Conversely, the position of the La 4f conduction bands of La{sub 2}O{sub 3} is in reasonable accord with experiment as it is with standard functionals. The functional narrows the Fe d bands of the parent compound LaFeAsO of the iron high-temperature superconductors while maintaining the high Fe spectral weight near the Fermi energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated Disposal Facility FY2011 Glass Testing Summary Report. Erratum

This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011). The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory Testing of Bulk Vitrified Low-Activity Waste Forms to Support the 2005 Integrated Disposal Facility Performance Assessment. Erratum

This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011). The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Disposal Facility FY 2012 Glass Testing Summary Report, Erratum

This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011) The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnetic Tuning of 2.8 min In-Vacuum Undulator

This report presents the magnetic tuning results and the final magnetic performance of the In-Vacuum Undulator 2.8 m S/N A13006. In order to improve the magnetic field quality in term of phase error and to reduce the field integral errors as well as the multipole field errors, different inhouse corrections have been carried out with Neomax's engineers. Although the vendor’s data were found satisfactory, the discrepancy between their magnetic field measurement results and BNL’s was not acceptable both for field integrals and phase error [1].

36 MATERIALS SCIENCE↗

Erratum: “Accurate modeling of the hose instability in plasma wakefield accelerators” [Phys. Plasmas 25, 056703 (2018)]

Here, we would like to correct a typographical error which was introduced in Eqs. (5), (11), (14), (20a), and (20b) during revision of Ref. 1. The series expansion of the plasmaelectron phase space density to the first order of ⟨x⟩ and ⟨px⟩ [Eq. (5) in Ref. 1] correctly reads f p ≈ f p 0 - cos θ (⟨x⟩∂r+ ⟨px⟩∂pr)f p,0 The zeroth-order term, f p,0 , was not printed in Ref. 1. Accordingly, the correct expansion of the wakefield potential [Eq. (11) in Ref. 1] is ψ(r,θ) ≈ ψ0(r) -cos θ X p ∂ r ψ 0 (r), the correct expansion of the source term of the wakefield potential [Eq. (14) in Ref. 1] is S(r, θ) ≈ S 0 (r) - cos θ X p ∂ r S 0 (r), and the correct expansions of the force terms [Eqs. (20a) and (20b) in Ref. 1] are F r,b ≈ F r,b,o - cos θ X b ∂ r Fr,b,0, F r,b ≈ F r,p,o - cos θ ⟨x⟩ ∂ r F r,p,0 , The zeroth order terms in Eqs. (5), (11), (14), (20a), and (20b) are missing in the printing of Ref. 1 but were fully taken into account for the calculation of all derived equations of the mathematical model. The developed mathematical model and physical conclusions in Ref. 1 are therefore all unaltered by, and consistent with, the above corrections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The orbit and transit prospects for β pictoris b constrained with one milliarcsecond astrometry

A principal scientific goal of the Gemini Planet Imager (GPI) is obtaining milliarcsecond astrometry to constrain exoplanet orbits. However, astrometry of directly imaged exoplanets is subject to biases, systematic errors, and speckle noise. Here, we describe an analytical procedure to forward model the signal of an exoplanet that accounts for both the observing strategy (angular and spectral differential imaging) and the data reduction method (Karhunen–Loève Image Projection algorithm). We use this forward model to measure the position of an exoplanet in a Bayesian framework employing Gaussian processes and Markov-chain Monte Carlo to account for correlated noise. In the case of GPI data on β Pic b, this technique, which we call Bayesian KLIP-FM Astrometry (BKA), outperforms previous techniques and yields 1σ errors at or below the one milliarcsecond level. We validate BKA by fitting a Keplerian orbit to 12 GPI observations along with previous astrometry from other instruments. The statistical properties of the residuals confirm that BKA is accurate and correctly estimates astrometric errors. Our constraints on the orbit of β Pic b firmly rule out the possibility of a transit of the planet at 10-σ significance. However, we confirm that the Hill sphere of β Pic b will transit, giving us a rare chance to probe the circumplanetary environment of a young, evolving exoplanet. As a result, we provide an ephemeris for photometric monitoring of the Hill sphere transit event, which will begin at the start of April in 2017 and finish at the end of January in 2018.

79 ASTRONOMY AND ASTROPHYSICS↗