Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “eclipse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Molecular Pivot-Hinge Installation to Evolve Topology in Rare-Earth Metal–Organic Frameworks

Linker desymmetrization has been witnessed as a powerful design strategy for the discovery of highly connected metal–organic frameworks (MOFs) with unprecedented topologies. Herein, we introduce molecular pivot-hinge installation as a linker desymmetrization strategy to evolve the topology of highly connected rare-earth (RE) MOFs, where a pivot group is placed in the center of a linker similar to a hinge. By tuning the composition of pivot groups and steric hindrances of the substituents on various linker rotamers, MOFs with various topologies can be obtained. The combination of L-SO 2 with C 2v symmetry and 12-connected RE9 clusters leads to the formation of a fascinating (4,12)-c dfs new topology. Interestingly, when replacing L-SO 2 with a tetrahedra linker L-O, the stacking behaviors of RE-organic layers switch from an eclipsed mode to a staggered stacking mode, leading to the discovery of an intriguing hjz topology. Additionally, the combination of the RE cluster and a linker [(L-(CH 3 ) 6 )] with more bulky groups gives rise to a flu topology with a new 8-c inorganic cluster. The diversity of these RE-MOFs was further enhanced through post-synthetic installation of linkers with various functional groups. Functionalization of each linker with acidic and basic units in the mesoporous RE-based PCN-90-SO 2 allows for efficient cascade catalytic transformation within the functionalized channels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hexaazatriphenylene‐Based Two‐Dimensional Conductive Covalent Organic Framework with Anisotropic Charge Transfer

Here, the development of covalent organic frameworks (COFs) with efficient charge transport is of immense interest for applications in optoelectronic devices. To enhance COF charge transport properties, electroactive building blocks and dopants can be used to induce extended conduction channels. However, understanding their intricate interplay remains challenging. We designed and synthesized a tailor-made COF structure with electroactive hexaazatriphenylene (HAT) core units and planar dioxin (D) linkages, denoted as HD-COF. With the support of theoretical calculations, we found that the HAT units in the HD-COF induce strong, eclipsed π–π stacking. The unique stacking of HAT units and the weak in-plane conjugation of dioxin linkages leads to efficient anisotropic charge transport. We fabricated HD-COF films to minimize the grain boundary effect of bulk COFs, which resulted in enhanced conductivity. As a result, the HD-COF films showed an electrical conductivity as high as 1.25 S cm −1 after doping with tris(4-bromophenyl)ammoniumyl hexachloroantimonate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and Electrocatalytic Activity of [FeFe]‐Hydrogenase Model Complexes with Non‐Innocent Chelating Nitrogen‐Donor Ligands

To probe the influence of redox non‐innocent ligands on a well‐known class of [FeFe]‐hydrogenase models, three new asymmetrically disubstituted diiron complexes of the general formula (µ‐SRS)[Fe(CO) 3 ][Fe(CO)(N‐N)] {SRS = propane‐1,3‐dithiolate (pdt) or benzene‐1,2‐dithiolate (bdt), and N‐N = 2,2′‐bipyridine (bipy) or 2,2′‐bipyrimidine (bpym)} have been synthesized from their parent hexacarbonyls and characterized. The new complexes, (µ‐pdt)Fe 2 (CO) 4 (κ 2 ‐bpym) ( 2 ), (µ‐bdt)Fe 2 (CO) 4 (κ 2 ‐bipy) ( 3 ), and (µ‐bdt)Fe 2 (CO) 4 (κ 2 ‐bpym) ( 4 ), were fully characterized by spectroscopic and electrochemical techniques, and the results are compared to those of a related complex, (µ‐pdt)Fe 2 (CO) 4 (κ 2 ‐bipy) ( 1 ). The crystal structures of 2 – 4 show that, in each complex, the two iron units are in an eclipsed orientation, and the N‐N ligand lies in the basal plane. IR spectra and electrochemical analyses indicate that electron density at the iron centers decreases in the order 1 > 2 > 3 > 4 . Furthermore, compound 2 undergoes a ligand‐centered reduction at the same potential that the hexacarbonyl precursor undergoes its first reduction. However, unlike the 2,2′‐bipy derivatives 1 and 3 , the 2,2′‐bpym complexes 2 and 4 are not effective catalysts for electrochemical proton reduction from acetic acid.

Roy, Souvik↗

An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique

To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random and systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Materials and engineering endeavors towards practical sodium-ion batteries

Sodium-ion batteries are making inroads toward better acceptance by both research and industry communities as promising electrochemical energy storage systems for stationary battery applications. Here, the extreme dedication to lithium-ion batteries, since the early 90s, has eclipsed any significant development around room temperature Na-ion batteries, despite the materials availability advantage the latter have over the Li-ion battery counterparts. Benefiting from the substantial knowledge accumulated on Li-ion batteries, tremendous progress rapidly occurred with focus on solving the fundamental issues encountered at the component, system and cost levels in Na-ion batteries. In this review, we discuss the key aspects that make Na-ion batteries enable the research of a wide spectrum of sodium-based materials and electrolytes, which further catalyzes the development of plethora of energy storage systems.

25 ENERGY STORAGE↗

Induced seismicity red-light thresholds for enhanced geothermal prospects in the Netherlands

Prospects for geothermal energy in the Netherlands have renewed concerns around induced earthquakes. Risks from induced earthquakes are managed by traffic light protocols (TLPs), where the red-light is chosen as the stop-point before exceeding a tolerance to risk. Here, we simulate post-shut-in earthquake scenarios based on realistic information for the Netherlands. We focus on three risk metrics: aggregates like nuisance and damage impacts and also local personal risk (LPR) – a likelihood of building collapse fatality for an individual. Our results show that the severity of these risks varies spatially by orders of magnitude. Prior induced seismicity (e.g., the 2012 Huizinge event) provides a reference baseline to calibrate the Dutch earthquake risk tolerances. We find that these calibrated risk tolerances are similar to those observed in North America, suggesting an underlying sociological ‘license to operate.’ Furthermore, the use of calibrated risk tolerances results in nuisance concerns completely eclipsing the other two metrics. We compare our results to a hypothetical Groningen geothermal operation and find that our approach sets red-light thresholds approximately one magnitude unit below the ML 3.6 Huizinge event. Overall, our results provide a first-order recommendation for red-light thresholds and proactive management of Dutch enhanced geothermal induced seismicity.

15 GEOTHERMAL ENERGY↗

Prospective Evaluation to Establish a Dose Response for Clinical Oral Mucositis in Patients Undergoing Head-and-Neck Conformal Radiotherapy

Purpose: We conducted a clinical study to correlate oral cavity dose with clinical mucositis, perform in vivo dosimetry, and determine the feasibility of obtaining buccal mucosal cell samples in patients undergoing head-and-neck radiation therapy. The main objective is to establish a quantitative dose response for clinical oral mucositis. Methods and Materials: Twelve patients undergoing radiation therapy for head-and-neck cancer were prospectively studied. Four points were chosen in separate quadrants of the oral cavity. Calculated dose distributions were generated by using AcQPlan and Eclipse treatment planning systems. MOSFET dosimeters were used to measure dose at each sampled point. Each patient underwent buccal sampling for future RNA analysis before and after the first radiation treatment at the four selected points. Clinical and functional mucositis were assessed weekly according to National Cancer Institute Common Toxicity Criteria, Version 3. Results: Maximum and average doses for sampled sites ranged from 7.4-62.3 and 3.0-54.3 Gy, respectively. A cumulative point dose of 39.1 Gy resulted in mucositis for 3 weeks or longer. Mild severity (Grade {<=} 1) and short duration ({<=}1 week) of mucositis were found at cumulative point doses less than 32 Gy. Polymerase chain reaction consistently was able to detect basal levels of two known radiation responsive genes. Conclusions: In our sample, cumulative doses to the oral cavity of less than 32 Gy were associated with minimal acute mucositis. A dose greater than 39 Gy was associated with longer duration of mucositis. Our technique for sampling buccal mucosa yielded sufficient cells for RNA analysis using polymerase chain reaction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Organ Motion on Conformal vs. Intensity-Modulated Pelvic Radiotherapy for Prostate Cancer

Purpose: To compare an intensity-modulated radiotherapy (IMRT) planning approach for prostate pelvic RT with a conformal RT (CRT) approach taking into account the influence of organ-at-risk (OAR) motion. Methods and Materials: A total of 20 male patients, each with one planning computed tomography scan and five to eight treatment computed tomography scans, were used for simulation of IMRT and CRT for delivery of a prescribed dose of 50 Gy to the prostate, seminal vesicles, and pelvic lymph nodes. Planning was done in Eclipse without correcting for OAR motion. Evaluation was performed using the CRT and IMRT dose matrices and the planning and treatment OAR outlines. The generalized equivalent uniform dose (gEUD) was calculated for 894 OAR volumes using a volume-effect parameter of 4, 12, and 8 for bowel, rectum and bladder, respectively. For the bowel, the gEUD was normalized to a reference volume of 200 cm{sup 3}. For each patient and each OAR, an average of the treatment gEUDs (gEUD{sub treat}) was calculated for CRT and IMRT. The paired t test was used to compare IMRT with CRT and gEUD{sub treat} with gEUD{sub plan}. Results: The mean gEUD{sub treat} was reduced from 43 to 40 Gy, 47 to 46 Gy, and 48 to 45 Gy with IMRT for the bowel, rectum, and bladder, respectively (p < 0.001). Differences between the gEUD{sub plan} and gEUD{sub treat} were not significant (p > 0.05) for any OAR but was >6% for the bowel in 6 of 20 patients. Conclusion: Intensity-modulated RT reduced the bowel, rectum, and bladder gEUDs also under influence of OAR motion. Neither CRT nor IMRT was robust against bowel motion, but IMRT was not less robust than CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calcifications Are Potential Surrogates for Prostate Localization in Image-Guided Radiotherapy

Purpose: To investigate the feasibility of using calcifications as surrogates for the prostate position during cone-beam computed tomography (CBCT) image-guided radiotherapy. Methods and Materials: The twice-weekly CBCT images taken during the treatment course of 4 patients were retrospectively studied for the stability of the calcifications. The geometric center of three fiducial markers was used as the reference. The planning CT images of 131 prostate patients recently treated with external beam radiotherapy at our center were reviewed to estimate the calcification occurrence rate. Analysis was conducted using the Varian Eclipse treatment planning system. Two patients were treated using prostate calcifications as the landmark in on-line registration. Both the Varian standard and the low-dose CBCT modes were used for imaging. Results: The calcifications were found to be stable during the treatment course. At the 95% confidence interval, the difference between the distance from an identified calcification to the fiducial markers on CBCT and the distance on the planning CT scans was 0.2 {+-} 2.0 mm, 0.8 {+-} 2.2 mm, and 0.4 {+-} 2.4 mm in the left-right, anteroposterior, and superoinferior direction, respectively. Of the 131 patients, 46 (35%) had well-defined calcifications either inside the prostate or near the borders. Our experience in treating the first 2 patients demonstrated that the calcifications are easily distinguished on low-dose scans and that calcification registration can be precisely performed. Conclusion: The results of our study have shown that calcifications can be reliable markers of prostate position and allow for precise image guidance with a low-imaging dose. With this approach, potentially about one-third of prostate patients could benefit from precise image guidance without the invasive use of markers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Isocenter Location for Intensity Modulated Stereotactic Treatment of Small Intracranial Targets

Purpose: To quantify the impact of isocenter location on treatment plan quality for intensity-modulated stereotactic treatment of small intracranial lesions. Methods and Materials: For 18 patients previously treated by stereotactic-intensity modulated radiosurgery (IMRS) or intensity-modulated radiation therapy (IMRT), a retrospective virtual planning study was conducted wherein the impact of isocenter location on plan quality was measured. Treatment indications studied included six arteriovenous malformations, six acoustic neuromas, and six intracranial metastases, ranging in volume from 0.71 to 3.21 cm{sup 3} (mean = 2.26 cm{sup 3}), 1.08 to 2.84 cm{sup 3} (mean = 1.73 cm{sup 3}), and 0.19 to 2.30 cm{sup 3} (mean = 0.79 cm{sup 3}), respectively. Variation of isocenter location causes the geometric grid of pencil beams into which the target is segmented for intensity-modulated treatment to be altered. The impact of this pencil-beam-grid redefinition on achievable conformity index was quantified for three collimators (Varian Millennium 120; BrainLab MM3; Nomos binary Mimic) and three treatment planning systems (TPS; Varian Eclipse v6.5; BrainLab BrainScan v5.31; Best-Nomos Corvus v6.2), resulting in the evaluation of 3,446 treatment plans. Results: For all patients, collimator, and TPS combinations studied, a significant variation in plan quality was observed as a function of isocenter and pencil-beam-grid relocation. Optimization of isocenter location resulted in treatment plan conformity variations as large as 109% (min = 15%, mean = 51%, max = 109%). Conclusion: Optimization of isocenter location for IMRT/IMRS treatment of small intracranial lesions in which pencil-beam dimensions are comparable to target dimensions, can result in significant improvements in treatment plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy Treatment Plans With RapidArc for Prostate Cancer Involving Seminal Vesicles and Lymph Nodes

Purpose: Dosimetric results and treatment delivery efficiency of RapidArc plans to those of conventional intensity-modulated radiotherapy (IMRT) plans were compared using the Eclipse treatment planning system for high-risk prostate cancer. Materials and Methods: This study included 10 patients. The primary planning target volume (PTV{sub P}) contained prostate, seminal vesicles, and pelvic lymph nodes with a margin. The boost PTV (PTV{sub B}) contained prostate and seminal vesicles with a margin. The total prescription dose was 75.6 Gy (46.8 Gy to PTV{sub P} and an additional 28.8 Gy to PTV{sub B}; 1.8 Gy/fraction). Three plans were generated for each PTV: Multiple-field IMRT, one-arc RapidArc (1ARC), and two-arc RapidArc (2ARC). Results: In the primary IMRT with PTV{sub P}, average mean doses to bladder, rectum and small bowel were lower by 5.9%, 7.7% and 4.3%, respectively, than in the primary 1ARC and by 3.6%, 4.8% and 3.1%, respectively, than in the primary 2ARC. In the boost IMRT with PTV{sub B}, average mean doses to bladder and rectum were lower by 2.6% and 4.8% than with the boost 1ARC and were higher by 0.6% and 0.2% than with the boost 2ARC. Integral doses were 7% to 9% higher with RapidArc than with IMRT for both primary and boost plans. Treatment delivery time was reduced by 2-7 minutes using RapidArc. Conclusion: For PTVs including prostate, seminal vesicles, and lymph nodes, IMRT performed better in dose sparing for bladder, rectum, and small bowel than did RapidArc. For PTVs including prostate and seminal vesicles, RapidArc with two arcs provided plans comparable to those for IMRT. The treatment delivery is more efficient with RapidArc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic, Single-Dose Irradiation of Lung Tumors: A Comparison of Absolute Dose and Dose Distribution Between Pencil Beam and Monte Carlo Algorithms Based on Actual Patient CT Scans

Purpose: Dose calculation based on pencil beam (PB) algorithms has its shortcomings predicting dose in tissue heterogeneities. The aim of this study was to compare dose distributions of clinically applied non-intensity-modulated radiotherapy 15-MV plans for stereotactic body radiotherapy between voxel Monte Carlo (XVMC) calculation and PB calculation for lung lesions. Methods and Materials: To validate XVMC, one treatment plan was verified in an inhomogeneous thorax phantom with EDR2 film (Eastman Kodak, Rochester, NY). Both measured and calculated (PB and XVMC) dose distributions were compared regarding profiles and isodoses. Then, 35 lung plans originally created for clinical treatment by PB calculation with the Eclipse planning system (Varian Medical Systems, Palo Alto, CA) were recalculated by XVMC (investigational implementation in PrecisePLAN [Elekta AB, Stockholm, Sweden]). Clinically relevant dose-volume parameters for target and lung tissue were compared and analyzed statistically. Results: The XVMC calculation agreed well with film measurements (<1% difference in lateral profile), whereas the deviation between PB calculation and film measurements was up to +15%. On analysis of 35 clinical cases, the mean dose, minimal dose and coverage dose value for 95% volume of gross tumor volume were 1.14 {+-} 1.72 Gy, 1.68 {+-} 1.47 Gy, and 1.24 {+-} 1.04 Gy lower by XVMC compared with PB, respectively (prescription dose, 30 Gy). The volume covered by the 9 Gy isodose of lung was 2.73% {+-} 3.12% higher when calculated by XVMC compared with PB. The largest differences were observed for small lesions circumferentially encompassed by lung tissue. Conclusions: Pencil beam dose calculation overestimates dose to the tumor and underestimates lung volumes exposed to a given dose consistently for 15-MV photons. The degree of difference between XVMC and PB is tumor size and location dependent. Therefore XVMC calculation is helpful to further optimize treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Volume Is a Prognostic Factor in Non-Small-Cell Lung Cancer Treated With Chemoradiotherapy

Purpose: To investigate whether primary tumor and nodal volumes defined on radiotherapy planning scans are correlated with outcome (survival and recurrence) after combined-modality treatment. Methods and Materials: A retrospective review of patients with Stage III non-small-cell lung cancer treated with chemoradiation at Brigham and Women's Hospital/Dana-Farber Cancer Institute from 2000 to 2006 was performed. Tumor and nodal volume measurements, as computed by Eclipse (Varian, Palo Alto, CA), were used as independent variables, along with existing clinical factors, in univariate and multivariate analyses for association with outcomes. Results: For patients treated with definitive chemoradiotherapy, both nodal volume (hazard ratio [HR], 1.09; p < 0.01) and tumor volume (HR, 1.03; p < 0.01) were associated with overall survival on multivariate analysis. Both nodal volume (HR, 1.10; p < 0.01) and tumor volume (HR, 1.04; p < 0.01) were also associated with local control but not distant metastases. Conclusions: In addition to traditional surgical staging variables, disease burden, measured by primary tumor and nodal metastases volume, provides information that may be helpful in determining prognosis and identifying groups of patients for which more aggressive local therapy is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer: A Dose-Escalation Planning Study

Purpose: To evaluate the potential for dose escalation with intensity-modulated radiotherapy (IMRT) in positron emission tomography-based radiotherapy planning for locally advanced non-small-cell lung cancer (LA-NSCLC). Methods and Materials: For 35 LA-NSCLC patients, three-dimensional conformal radiotherapy and IMRT plans were made to a prescription dose (PD) of 66 Gy in 2-Gy fractions. Dose escalation was performed toward the maximal PD using secondary endpoint constraints for the lung, spinal cord, and heart, with de-escalation according to defined esophageal tolerance. Dose calculation was performed using the Eclipse pencil beam algorithm, and all plans were recalculated using a collapsed cone algorithm. The normal tissue complication probabilities were calculated for the lung (Grade 2 pneumonitis) and esophagus (acute toxicity, grade 2 or greater, and late toxicity). Results: IMRT resulted in statistically significant decreases in the mean lung (p <.0001) and maximal spinal cord (p = .002 and 0005) doses, allowing an average increase in the PD of 8.6-14.2 Gy (p {<=}.0001). This advantage was lost after de-escalation within the defined esophageal dose limits. The lung normal tissue complication probabilities were significantly lower for IMRT (p <.0001), even after dose escalation. For esophageal toxicity, IMRT significantly decreased the acute NTCP values at the low dose levels (p = .0009 and p <.0001). After maximal dose escalation, late esophageal tolerance became critical (p <.0001), especially when using IMRT, owing to the parallel increases in the esophageal dose and PD. Conclusion: In LA-NSCLC, IMRT offers the potential to significantly escalate the PD, dependent on the lung and spinal cord tolerance. However, parallel increases in the esophageal dose abolished the advantage, even when using collapsed cone algorithms. This is important to consider in the context of concomitant chemoradiotherapy schedules using IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Accelerator-Based Intensity-Modulated Total Marrow Irradiation Technique for Treatment of Hematologic Malignancies: A Dosimetric Feasibility Study

Purpose: To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Methods and Materials: Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. Results: A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. Conclusion: The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Single Fraction Partial Breast Radiotherapy for Early-Stage Breast Cancer

Purpose: Several recent series evaluating external beam accelerated partial breast irradiation (PBI) have reported adverse cosmetic outcomes, possibly related to large volumes of normal tissue receiving near-prescription doses. We hypothesized that delivery of external beam PBI in a single fraction to the preoperative tumor volume would be feasible and result in a decreased dose to the uninvolved breast compared with institutional postoperative PBI historical controls. Methods and Materials: A total of 17 patients with unifocal Stage T1 breast cancer were identified. Contrast-enhanced subtraction magnetic resonance images were loaded into an Eclipse treatment planning system and used to define the target volumes. A 'virtual plan' was created using four photon beams in a noncoplanar beam arrangement and optimized to deliver 15 Gy to the planning target volume. Results: The median breast volume was 1,713 cm{sup 3} (range: 1,014-2,140), and the median clinical target volume was 44 cm{sup 3} (range: 26-73). In all cases, 100% of the prescription dose covered 95% of the clinical target volume. The median conformity index was 0.86 (range: 0.70-1.12). The median percentage of the ipsilateral breast volume receiving 100% and 50% of the prescribed dose was 3.8% (range: 2.2-6.9) and 13.3% (range: 7.5-20.8) compared with 18% (range: 3-42) and 53% (range: 24-65) in the institutional historical controls treated with postoperative external beam PBI (p = .002). The median maximum skin dose was 9 Gy. The median dose to 1 and 10 cm{sup 3} of skin was 6.7 and 4.9 Gy. The doses to the heart and ipsilateral lung were negligible. Conclusion: Preoperative PBI resulted in a substantial reduction in ipsilateral breast tissue dose compared with postoperative PBI. The skin dose appeared reasonable, given the small volumes. A prospective Phase I trial evaluating this technique is ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Combined Intensity-Modulated Radiotherapy (IMRT) and Proton Therapy Versus IMRT Alone for Pelvic and Para-Aortic Radiotherapy in Gynecologic Malignancies

Purpose: To perform a dosimetric comparison of intensity-modulated radiotherapy (IMRT), passive scattering proton therapy (PSPT), and intensity-modulated proton therapy (IMPT) to the para-aortic (PA) nodal region in women with locally advanced gynecologic malignancies. Methods and Materials: The CT treatment planning scans of 10 consecutive patients treated with IMRT to the pelvis and PA nodes were identified. The clinical target volume was defined by the primary tumor for patients with cervical cancer and by the vagina and paravaginal tissues for patients with endometrial cancer, in addition to the regional lymph nodes. The IMRT, PSPT, and IMPT plans were generated using the Eclipse Treatment Planning System and were analyzed for various dosimetric endpoints. Two groups of treatment plans including proton radiotherapy were created: IMRT to pelvic nodes with PSPT to PA nodes (PSPT/IMRT), and IMRT to pelvic nodes with IMPT to PA nodes (IMPT/IMRT). The IMRT and proton RT plans were optimized to deliver 50.4 Gy or Gy (relative biologic effectiveness [RBE)), respectively. Dose-volume histograms were analyzed for all of the organs at risk. The paired t test was used for all statistical comparison. Results: The small-bowel V{sub 20}, V{sub 30}, V{sub 35}, andV{sub 40} were reduced in PSPT/IMRT by 11%, 18%, 27%, and 43%, respectively (p < 0.01). Treatment with IMPT/IMRT demonstrated a 32% decrease in the small-bowel V{sub 20}. Treatment with PSPT/IMRT showed statistically significant reductions in the body V{sub 5-20}; IMPT/IMRT showed reductions in the body V{sub 5-15}. The dose received by half of both kidneys was reduced by PSPT/IMRT and by IMPT/IMRT. All plans maintained excellent coverage of the planning target volume. Conclusions: Compared with IMRT alone, PSPT/IMRT and IMPT/IMRT had a statistically significant decrease in dose to the small and large bowel and kidneys, while maintaining excellent planning target volume coverage. Further studies should be done to correlate the clinical significance of these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Personalized Assessment of kV Cone Beam Computed Tomography Doses in Image-guided Radiotherapy of Pediatric Cancer Patients

Purpose: To develop a quantitative method for the estimation of kV cone beam computed tomography (kVCBCT) doses in pediatric patients undergoing image-guided radiotherapy. Methods and Materials: Forty-two children were retrospectively analyzed in subgroups of different scanned regions: one group in the head-and-neck and the other group in the pelvis. Critical structures in planning CT images were delineated on an Eclipse treatment planning system before being converted into CT phantoms for Monte Carlo simulations. A benchmarked EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions of kVCBCT scans with full-fan high-quality head or half-fan pelvis protocols predefined by the manufacturer. Based on planning CT images and structures exported in DICOM RT format, occipital-frontal circumferences (OFC) were calculated for head-and-neck patients using DICOMan software. Similarly, hip circumferences (HIP) were acquired for the pelvic group. Correlations between mean organ doses and age, weight, OFC, and HIP values were analyzed with SigmaPlot software suite, where regression performances were analyzed with relative dose differences (RDD) and coefficients of determination (R{sup 2}). Results: kVCBCT-contributed mean doses to all critical structures decreased monotonically with studied parameters, with a steeper decrease in the pelvis than in the head. Empirical functions have been developed for a dose estimation of the major organs at risk in the head and pelvis, respectively. If evaluated with physical parameters other than age, a mean RDD of up to 7.9% was observed for all the structures in our population of 42 patients. Conclusions: kVCBCT doses are highly correlated with patient size. According to this study, weight can be used as a primary index for dose assessment in both head and pelvis scans, while OFC and HIP may serve as secondary indices for dose estimation in corresponding regions. With the proposed empirical functions, it is possible to perform an individualized quantitative dose assessment of kVCBCT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗