Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Fuel droplet combustion

An analytical model is developed that demonstrates the behavior of fuel drop ignition, and experimental results are presented that describe the effect of aerodynamic shattering on the process of fuel drop ignition. It is shown that the explosive ignition of a fuel drop which interacts with a shock wave in an oxidizing atmosphere depends upon the production of a fuel-oxidizer mixture in the wake of the original drop. The creation of this mixture is dependent on the formation of fine spray as a result of the aerodynamic shattering of the original fuel drop, the evaporation of the fine spray, and the mixing of the fuel vapor with the surrounding hot oxidizer. Only then does the explosive ignition occur as a result of the chemical reaction between the gaseous fuel and oxidizer.

Kauffman, C. W.↗

Analysis of Skylab IV fluid mechanic science demonstration

Several science demonstrations performed on Skylab III and IV were concerned with the behavior of fluid drops free floating in microgravity. These demonstrations, with large liquid drops, included the oscillation, rotation, impact and coalescence, and air injection into the drops. Rayleigh's analysis of the oscillation of spherical drops of a liquid predicts accurately the effect of size and surface tension on the frequency of vibrated water globules in the Skylab demonstration. However, damping occurred much faster than predicted by Lamb's or Scriven's analyses of the damping time for spherical drops. The impact demonstrations indicated that a minimum velocity is necessary to overcome surface forces and effect a coalescence, but a precise criterion for the coalescence of liquids in low g could not be determined.

Klett, M. G.↗

Susceptibility measurements on the superconducting properties of Nb-Ge alloys

A susceptibility apparatus to measure superconducting properties of samples made in the MSFC Drop Tube was used to measure the transition temperature (Tc) and susceptibilities of Nb and Nb Ge Alloys prepared in bulk spherical (2-4 mm diameter) form using a 32 m drop tube in which containerless low gravity solidification could take place. Results indicate that a drop tube processing environment was beneficial for increasing the Tc of the superconducting phase of the material over that of arc melted material. The increase in Tc is found to be related to the amount of solidification of the total sample that took place before reaching the bottom of the drop tube. In phase and quadrature phase measurements of the specimen's susceptibility indicated that some improvement in homogeneity takes place in drop tube processing. These phase measurements also indicated little or no shielding of a lower Tc phase by a higher Tc filamentary structure.

Rathz, T. J.↗

Comparison of Three Multicylinder Icing Meters and Critique of Multicylinder Method

Three multicylinder cloud meters, fundamentally similar but differing in important details, were compared in use at the Mount Washington Observatory. Determinations of liquid water content were found to agree within the limits of the probable error, but the two instruments designed by the National Advisory Committee for Aeronautics indicated larger drop sizes than did the Observatory's instrument, apparently because of spurious ice catch on the rather rough surface of the larger cylinders. Comparisons of drop-size distribution were largely indeterminate., In a critique of the method, the probable error of determination of liquid water content was found to be +/-8 percent; of drop size, +/-6 percent; and of drop-size distribution, about +/-0.7 unit of the modulus of distribution. Of the systematic errors, run-off of unfrozen water is most important, blow-off and erosion seldom being hampering. Revision of collection-efficiency computations for cylinders in clouds with distributed drop sizes was found necessary and also revision of one of the correction-factor graphs heretofore used. The assumption of constant ice density in deriving cylinder size was found to be permissible for cylinders 1 inch or more in diameter.

Howell, Wallace E.↗

A variational approach to the study of capillary phenomena

The problem of determining the free surface of a liquid in a capillary tube, and of a liquid drop, sitting first on a horizontal plane and then on more general surfaces is considered. With some modifications, the method applies to the study of pendent drops and of rotating drops as well. The standard capillary problem, i.e. the determination of the free surface of a liquid in a thin tube of general cross section, which resuls from the simultaneous action of surface tension, boundary adhesion and gravity is discussed. It turns out that in this case the existence of the solution surface depends heavily on the validity of a simple geometric condition about the mean curvature of the boundary curve of the cross section of the capillary tube. Some particular examples of physical interest are also be discussed. Liquid drops sitting on or hanging from a fixed horizontal plane are discussed. The symmetry of the solutions (which can actually be proved, as consequence of a general symmetrization argument) now plays the chief role in deriving both the existence and the regularity of energy-minimizing configurations. When symmetry fails (this is the case, for example, when the contact angle between the drop and the plate is not constant, or when the supporting surface is not itself symmetric), then more sophisticated methods must be used. Extensions in this direction are outlined.

Emmer, M.↗

A theoretical and experimental study of turbulent nonevaporating sprays

Measurements and analysis limited to the dilute portions of turbulent nonevaporating sprays injected into a still air environment were completed. Mean and fluctuating velocities and Reynolds stress were measured in the continuous phase. Liquid phase measurements included liquid mass fluxes, drop sizes and drop size and velocity correlation. Initial conditions needed for model evaluation were measured at a location as close to the injector exit as possible. The test sprays showed significant effects of slip and turbulent dispersion of the discrete phase. The measurements were used to evaluate three typical models of these processes: (1) a locally homogenous flow (LHF) model, where slip between the phases were neglected; (2) a deterministic separated flow (DSF) model, where slip was considered but effects of drop dispersion by turbulence were ignored; and (3) a stochastic separated flow (SSF) model, where effects of interphase slip and turbulent dispersion were considered using random-walk computations for drop motion. The LHF and DSF models did not provide very satisfactory predictions for the present measurements. In contrast, the SSF model performed reasonably well with no modifications in the prescription of eddy properties from its original calibration. Some effects of drops on turbulence properties were observed near the dense regions of the sprays.

Solomon, A. S. P.↗

Structure of nonevaporating sprays. I - Initial conditions and mean properties

Structure measurements were completed within the dilute portion of axisymmetric nonevaporating sprays. Measurements included: mean velocities, velocity fluctuations, and Reynolds stress of the gas phase; and mean velocities, fluctuating velocities, mass flux, and diameter distributions of the drop phase. The measurements were used to evaluate three typical methods of analyzing sprays: (1) a locally homogeneous flow (LHF) analysis, where slip between the phases is neglected; (2) a deterministic separated flow (DSF) analysis, where slip is considered but effects of drop interactions with turbulence are ignored; and (3) a stochastic separated flow (SSF) analysis, where effects of both slip and turbulence are considered using random-walk computations for drop motion. Measurements of initial conditions of both phases near the injector, mean gas-phase properties, and liquid flux distributions are described herein. Best agreement between predictions and measurements was obtained with the SSF model, which provided a reasonable representation of turbulent dispersion of drops. A companion paper presents additional measurements of drop continuous phase properties.

Solomon, A. S. P.↗

Water jet/spray measurement analysis

The objective of this study was to provide analysis of data obtained under a previous contract entitled Characterization of Drop Spectra from High Volume Flow Water Jets. Measurements of drop spectra were obtained in the spray resulting from the breakup of high volume flow water jets from a variety of nozzle types. The drop spectra measurements were obtained from two drop spectrometers covering a range from 10 microns to 12 millimeters diameter. The task addressed was to select representative spectra from the individual tests and provide analyses in both numerical and graphical formats as outlined in the proposal. The intended application of these results is an evaluation of the feasibility of fog clearing by high volume water sprays. During the tests, a fog event occurred making it possible to test the concept of fog clearing. Visual range data and fog drop spectra were analyzed, with particular emphasis placed on the modification of these parameters due to the water spray.

Lala, G. G.↗

Modeling of dense sprays from LOX/H2 coaxial injectors under supercritical conditions

Assumptions commonly employed in the analytical description of a thin spray become unacceptable as the droplet density and droplet volume displacement become large. Changes in the semiempirical models describing drop-drop or drop-gas interactions as well as in the basic modeling approach itself may be necessary. A number of efforts undertaken to improve such models of the atomization-evaporation process to render them applicable in the dense-spray, supercritical regime are described. The improvements include those for variable drop density, supercritical properties, stripping evaporation and drop reincorporation into the liquid stream. The models are developed for use with the ARICC three-phase finite difference combustion code. Selected results from a sample calculation are presented, demonstrating the enhanced realism achievable with the upgraded models.

Liang, P. Y.↗

Two-phase flow

An experimental program to characterize the spray from candidate nozzles for icing-cloud simulation is discussed. One canidate nozzle, which is currently used for icing research, has been characterized for flow and drop size. The median-volume diameter (MVD) from this air-assist nozzle is compared with correlations in the literature. The new experimental spray facility is discussed, and the drop-size instruments are discussed in detail. Since there is no absolute standard for drop-size measurements and there are other limitations, such as drop -size range and velocity range, several instruments are used and results are compared. A two-phase model was developed at Pennsylvania State University. The model uses the k-epsilon model of turbulence in the continous phase. Three methods for treating the discrete phase are used: (1) a locally homogeneous flow (LHF) model, (2) a deterministic separated flow (DSF) model, and (3) a stochastic separated flow (SSF) model. In the LHF model both phases have the same velocity and temperature at each point. The DSF model provides interphase transport but ignores the effects of turbulent fluctuations. In the SSF model the drops interact with turbulent eddies whose properties are determined by the k-epsilon turbulence model. The two-phase flow model has been extended to include the effects of evaporation and combustion.

Tacina, Robert R.↗

Atmospheric science

The following types of experiments for a proposed Space Station Microgravity Particle Research Facility are described: (1) growth of liquid water drop populations; (2) coalescence; (3) drop breakup; (4) breakup of freezing drops; (5) ice nucleation for large aerosols or bacteria; (6) scavenging of gases, for example, SO2 oxidation; (7) phoretic forces, i.e., thermophoresis versus diffusiophoresis; (8) Rayleigh bursting of drops; (9) charge separation due to collisions of rimed and unrimed ice; (10) charged drop dynamics; (11) growth of particles in other planetary atmospheres; and (12) freezing and liquid-liquid evaporation. The required capabilities and desired hardware for the facility are detailed.

Hamill, Patrick↗

Containerless processing of undercooled melts

Containerless drop tube processing allows for significant levels of liquid undercooling through control of parameters such as sample size, surface coating and cooling rate. A laboratory scale (3 m) drop tube has been developed which allows the undercooling and solidification behavior of powder samples to be evaluated under low gravity free-fall conditions. The level of undercooling obtained in an InSb-Sb eutectic alloy has been evaluated by comparing the eutectic spacing in drop tube samples with a spacing/undercooling relationship established using thermal analysis techniques. Undercoolings of 0.17 and 0.23 T(e) were produced by processing under vacuum and He gas conditions respectively. Alternatively, the formation of an amorphous phase in a Ni-Nb eutectic alloy indicates that undercooling levels of approximately 500 C were obtained by drop tube processing. The influence of droplet size and gas environment on undercooling behavior in the Ni-Nb eutectic was evaluated through their effect on the amorphous/crystalline phase ratio. To supplement the structural analysis, heat flow modeling has been developed to describe the undercooling history during drop tube processing, and the model has been tested experimentally.

Shong, D. S.↗

Acoustic containerless experiment system: A non-contact surface tension measurement

The Acoustic Containerless Experiment System (ACES) was flown on STS 41-B in February 1984 and was scheduled to be reflown in 1986. The primary experiment that was to be conducted with the ACES module was the containerless melting and processing of a fluoride glass sample. A second experiment that was to be conducted was the verification of a non-contact surface tension measurement technique using the molten glass sample. The ACES module consisted of a three-axis acoustic positioning module that was inside an electric furnace capable of heating the system above the melting temperature of the sample. The acoustic module is able to hold the sample with acoustic forces in the center of the chamber and, in addition, has the capability of applying a modulating force on the sample along one axis of the chamber so that the molten sample or liquid drop could be driven into one of its normal oscillation modes. The acoustic module could also be adjusted so that it could place a torque on the molten drop and cause the drop to rotate. In the ACES, a modulating frequency was applied to the drop and swept through a range of frequencies that would include the n = 2 mode. A maximum amplitude of the drop oscillation would indicate when resonance was reached and from that data the surface tension could be calculated. For large viscosity samples, a second technique for measuring surface tension was developed. The results of the ACES experiment and some of the problems encountered during the actual flight of the experiment will be discussed.

Elleman, D. D.↗

Noncontact measurement of high temperature using optical fiber sensors

The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.

Claus, R. O.↗

Isolation of crystallizing droplets by electrostatic levitation

The principles of electrostatic levitation where the positioning and stabilization of a sample are accomplished by applying appropriate electrostatic forces to a charged sample are outlined, and attention is focused on a feedback control algorithm, drop-launching method, and four-drop levitator. Drop levitation in 1-g is discussed, and crystal-growth experiments are presented. An experiment in which the protein concentration of a levitated drop is controlled by a feedback system is described. During levitation, the drop evaporation rate is controlled in a programmed way in order to acquire proper protein concentration levels for both nucleation and growth. The containerless approach of protein crystal growth when applied in the space environment is assessed.

Rhim, Won-Kyu↗

Materials processing in low gravity

Several NASA facilities are available for low gravity experimentation: the Drop Facilities at NASA Marshall and the KC-135 at NASA Johnson. The use of these facilities allows for a rather inexpensive method of determining whether or not particular experiments will be worthwhile candidates for space experiments. Equipment currently available include various furnaces for the Drop Tube, the Drop Tower, and the KC-135. The furnaces for the Drop Tube include both an electron beam and electromagnetic levitation furnace. A vacuum furnace is used for the Drop Tower. Several furnaces used in performing KC-135 solidification experiments include the Automated Directional Solidification Furnace, the Isothermal Casting Furnace, the Rapid Melt/Rapid Quench and the Polymer/Video Furnaces.

Workman, Gary L.↗

Studies on fuel spray characteristics in high-pressure environment

The present study deals with several issues involving the improvement of physical submodels and the computational efficiency in modeling dense fuel sprays. To improve the computational efficiency, a parcel PDF approach is implemented which can account for turbulent dispersion within each computational parcel. The advantage of a parcel PDF tracking method is to reduce the number of computational parcels representing the spray dynamics as well as to obtain grid-independent solutions for two-phase flows. To account for the dense spray effects, an existing drop collision and coalescence model, two breakup models, and a Reitz's wave instability model were used. These models were incorporated into a state-of-the-art multiphase all-speed transient flow solution procedure. Comparative performance for two breakup models as well as the turbulence modulation effects are also studied. Validation cases include the nonevaporating and evaporating solid-cone dense sprays. The predictions show a reasonably good agreement with available experimental results in terms of spray penetration, drop sizes, gas and drop mean velocities, and gas and drop rms velocities. The numerical results indicate that the present parcel PDF model has the capability of accurately representing drop dispersion in dense sprays with manageable number of computational parcels.

Shang, H. M.↗

Dynamic and Flight Tests on Rubber-Cord and Oleo-Rubber-Disk Landing Gears for an F6C-4 Airplane

The investigation described in this report was conducted for the purpose of comparing an oleo-rubber-disk and a rubber-cord landing gear, built for use on an F6C-4 airplane. The investigation consisted of drop tests under various loading conditions and flight tests on an F6C-4 airplane. In the drop tests the total work done on each gear and the work done on each of the shock-absorbing units were determined. For both drop tests and flight tests the maximum loads and accelerations were determined. The comparative results showed that the oleo gear was slightly superior in reducing the ordinary landing shocks, that it had a greater capacity for work, and that it was very superior in the reduction of the rebound. The results further showed that for drops comparable to very severe landings, the rubber-cord gear was potentially more effective as a shock-reducing mechanism. However, due to the construction of this chassis, which limited the maximum elongation of the cords, this gear was incapable of withstanding as severe tests as the oleo gear. The action of the oleo gear was greatly inferior to the action of an ideal gear. The maximum accelerations encountered during the flight tests for severe landings were 3.64g for the rubber-cord gear and 2.27g for the oleo gear. These were less than those experienced in free drops of 7 inches on either gear.

Peck, William C↗