Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Abstract for CRADA between NETL and the University of Massachusetts Lowell (AGMT-1275)

The demand for printed electronics over conventional electronics is growing each year due to their low costs, low material waste during manufacturing, and compatibility with flexible substrates. The development of inks for printed electronics is a challenge because each printing technology requires different viscosities and curing behaviors to create devices with controlled structures at the micron scale, or smaller. Carbon is a great candidate for fabricating printed electronics devices because it is inexpensive and earth abundant, easily functionalized to impart miscibility with solvent systems, and has electrical properties that can be tuned from insulating to conducting. Despite these advantages, carbons are rarely used for printed electronics because there is a scarcity of inks available for non-contact printing technologies. To address these challenges, the National Energy Technology Laboratory (NETL) will collaborate with the University of Massachusetts Lowell (Participant) through its Printed Electronics Research Collaborative (PERC) to develop engineered carbons and ink formulations optimized specifically for printing radio- and microwave-frequency electronic devices using ink jet, aerosol jet, syringe dispensing, and other additive manufacturing techniques. NETL will process coal, petroleum, and other carbon feedstocks to make engineered carbons with the appropriate composition, microstructure, surface functionalization, and particle morphologies needed to stabilize ink suspensions and impart useful electronic properties to printed devices. The University of Massachusetts Lowell will utilize these engineered carbons to determine which solvent systems and ink additives are needed to achieve the appropriate viscosity, stability, and printability to make useful ink formulations. The University of Massachusetts Lowell will then utilize these inks to manufacture printed resistors and conductors using inkjet, aerosol jet, and syringe dispensing printing methods and will characterize device performance using four-point probe resistivity measurements, contact angle measurements to assess wettability, adhesion evaluation to various substrates, and focused ion beam and scanning electron microscopy for surface and density investigations of printed devices.

36 MATERIALS SCIENCE↗

Northwest Open Automated Demand Response Technology Demonstration Project

The Lawrence Berkeley National Laboratory (LBNL) Demand Response Research Center (DRRC) demonstrated and evaluated open automated demand response (OpenADR) communication infrastructure to reduce winter morning and summer afternoon peak electricity demand in commercial buildings the Seattle area. LBNL performed this demonstration for the Bonneville Power Administration (BPA) in the Seattle City Light (SCL) service territory at five sites: Seattle Municipal Tower, Seattle University, McKinstry, and two Target stores. This report describes the process and results of the demonstration. OpenADR is an information exchange model that uses a client-server architecture to automate demand-response (DR) programs. These field tests evaluated the feasibility of deploying fully automated DR during both winter and summer peak periods. DR savings were evaluated for several building systems and control strategies. This project studied DR during hot summer afternoons and cold winter mornings, both periods when electricity demand is typically high. This is the DRRC project team's first experience using automation for year-round DR resources and evaluating the flexibility of commercial buildings end-use loads to participate in DR in dual-peaking climates. The lessons learned contribute to understanding end-use loads that are suitable for dispatch at different times of the year. The project was funded by BPA and SCL. BPA is a U.S. Department of Energy agency headquartered in Portland, Oregon and serving the Pacific Northwest. BPA operates an electricity transmission system and markets wholesale electrical power at cost from federal dams, one non-federal nuclear plant, and other non-federal hydroelectric and wind energy generation facilities. Created by the citizens of Seattle in 1902, SCL is the second-largest municipal utility in America. SCL purchases approximately 40% of its electricity and the majority of its transmission from BPA through a preference contract. SCL also provides ancillary services within its own balancing authority. The relationship between BPA and SCL creates a unique opportunity to create DR programs that address both BPA's and SCL's markets simultaneously. Although simultaneously addressing both market could significantly increase the value of DR programs for BPA, SCL, and the end user, establishing program parameters that maximize this value is challenging because of complex contractual arrangements and the absence of a central Independent System Operator or Regional Transmission Organization in the northwest.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On-demand fabrication of piezoelectric sensors for in-space structural health monitoring

Abstract Inflatable structures, promising for future deep space exploration missions, are vulnerable to damage from micrometeoroid and orbital debris impacts. Polyvinylidene fluoride-trifluoroethylene (PVDF-trFE) is a flexible, biocompatible, and chemical-resistant material capable of detecting impact forces due to its piezoelectric properties. This study used a state-of-the-art material extrusion system that has been validated for in-space manufacturing, to facilitate fast-prototyping of consistent and uniform PVDF-trFE films. By systematically investigating ink synthesis, printer settings, and post-processing conditions, this research established a comprehensive understanding of the process-structure-property relationship of printed PVDF-trFE. Consequently, this study consistently achieved the printing of PVDF-trFE films with a thickness of around 40 µ m, accompanied by an impressive piezoelectric coefficient of up to 25 pC N −1 . Additionally, an all-printed dynamic force sensor, featuring a sensitivity of 1.18 V N −1 , was produced by mix printing commercial electrically-conductive silver inks with the customized PVDF-trFE inks. This pioneering on-demand fabrication technique for PVDF-trFE films empowers future astronauts to design and manufacture piezoelectric sensors while in space, thereby significantly enhancing the affordability and sustainability of deep space exploration missions.

Instruments & Instrumentation↗

Secure Interoperable Open Smart Grid Demonstration Project

The Consolidated Edison, Inc., of New York (Con Edison) Secure Interoperable Open Smart Grid Demonstration Project (SGDP), sponsored by the United States (US) Department of Energy (DOE), demonstrated that the reliability, efficiency, and flexibility of the grid can be improved through a combination of enhanced monitoring and control capabilities using systems and resources that interoperate within a secure services framework. The project demonstrated the capability to shift, balance, and reduce load where and when needed in response to system contingencies or emergencies by leveraging controllable field assets. The range of field assets includes curtailable customer loads, distributed generation (DG), battery storage, electric vehicle (EV) charging stations, building management systems (BMS), home area networks (HANs), high-voltage monitoring, and advanced metering infrastructure (AMI). The SGDP enables the seamless integration and control of these field assets through a common, cyber-secure, interoperable control platform, which integrates a number of existing legacy control and data systems, as well as new smart grid (SG) systems and applications. By integrating advanced technologies for monitoring and control, the SGDP helps target and reduce peak load growth, improves the reliability and efficiency of Con Edison’s grid, and increases the ability to accommodate the growing use of distributed resources. Con Edison is dedicated to lowering costs, improving reliability and customer service, and reducing its impact on the environment for its customers. These objectives also align with the policy objectives of New York State as a whole. To help meet these objectives, Con Edison’s long-term vision for the distribution grid relies on the successful integration and control of a growing penetration of distributed resources, including demand response (DR) resources, battery storage units, and DG. For example, Con Edison is expecting significant long-term growth of DG. The SGDP enables the efficient, flexible integration of these disparate resources and lays the architectural foundations for future scalability. Con Edison assembled an SGDP team of more than 16 different project partners, including technology vendors, and participating organizations, and the Con Edison team provided overall guidance and project management. Project team members are listed in Table 1-1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power market models for the clean energy transition: State of the art and future research needs

As power systems around the world are rapidly evolving to achieve decarbonization objectives, it is crucial that power system planners and operators use appropriate models and tools to analyze and address the associated challenges. This paper provides a detailed overview of the properties of power market models in the context of the clean energy transition. We review common power market model methodologies, their readiness for low- and zero-carbon grids, and new power market trends. Based on the review, we suggest model improvements and new designs to increase modeling capabilities for future grids. The paper highlights key modeling concepts related to power system flexibility, with a particular focus on hydropower and energy storage, as well as the representation of grid services, price formation, temporal structure, and the importance of uncertainty. We find that a changing resource mix, market restructuring, and growing price uncertainty require more precise modeling techniques to adequately capture the new technology constraints and the dynamics of future power markets. In particular, models must adequately represent resource opportunity costs, multi-horizon flexibility, and energy storage capabilities across the full range of grid services. Moreover, at the system level, it is increasingly important to consider sub-hourly time resolution, enhanced uncertainty representation, and introduce co-optimization for dual market clearing of energy and grid services. Likewise, models should capture interdependencies between multiple energy carriers and demand sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Gas Storage Technology Consortium

The EMS Energy Institute at The Pennsylvania State University (Penn State) has managed the Gas Storage Technology Consortium (GSTC) since its inception in 2003. The GSTC infrastructure provided a means to accomplish industry-driven research and development designed to enhance the operational flexibility and deliverability of the nation's gas storage system, and provide a cost-effective, safe, and reliable supply of natural gas to meet domestic demand. The GSTC received base funding from the U.S. Department of Energy's (DOE) National Energy Technology Laboratory (NETL) Oil & Natural Gas Supply Program. The GSTC base funds were highly leveraged with industry funding for individual projects. Since its inception, the GSTC has engaged 67 members. The GSTC membership base was diverse, coming from 19 states, the District of Columbia, and Canada. The membership was comprised of natural gas storage field operators, service companies, industry consultants, industry trade organizations, and academia. The GSTC organized and hosted a total of 18 meetings since 2003. Of these, 8 meetings were held to review, discuss, and select proposals submitted for funding consideration. The GSTC reviewed a total of 75 proposals and committed co-funding to support 31 industry-driven projects. The GSTC committed co-funding to 41.3% of the proposals that it received and reviewed. The 31 projects had a total project value of $6,203,071 of which the GSTC committed $3,205,978 in co-funding. The committed GSTC project funding represented an average program cost share of 51.7%. Project applicants provided an average program cost share of 48.3%. In addition to the GSTC co-funding, the consortium provided the domestic natural gas storage industry with a technology transfer and outreach infrastructure. The technology transfer and outreach were conducted by having project mentoring teams and a GSTC website, and by working closely with the Pipeline Research Council International (PRCI) to jointly host technology transfer meetings and occasional field excursions. A total of 15 technology transfer/strategic planning workshops were held.

03 NATURAL GAS↗

Advanced Reactors Integrated Energy System: Thermal Energy Storage Island Design

The main topic of this research is integrated energy systems (IES) designed for pairing industrial thermal energy loads with advanced reactors (ARs). The Idaho National Laboratory (INL) Crosscutting Technology Development IES program and the National Reactor Innovation Center (NRIC) are seeking to develop, design, and construct an AR-IES demonstration platform that couples the thermal output from an AR operating at the INL/NRIC Demonstration of Microreactor Experiments (DOME) test bed in the Experimental Breeder II dome to a variable capacity load emulator (i.e., air-cooled radiator) and sensible thermal energy storage (TES) via a molten salt thermal energy transfer fluid. In the rapidly evolving landscape of energy supply and distribution, flexibility has emerged as a prized attribute, surpassing the traditional notions of stability and baseload generation capability. This shift in priorities is particularly evident in the context of nuclear power plants (NPPs), where adaptability over constant output is becoming more important. As our energy infrastructure and resources embraces the rise of distributed energy generation, the inherent variability in net demand continues to grow. Moreover, the use of nuclear energy as a source of heat for decarbonizing the industrial sector is becoming a very pressing topic. In such environment, advanced NPPs are poised to enter a more competitive energy market, delivering both, flexible electricity and heat. This shift motivates the exploration of TES systems, designed to empower NPPs with nimble responsiveness to market fluctuations, flexible heat delivery capabilities, and redefine their role in the energy field. TES systems offer the unique advantage of storing nuclear energy in its original form as heat, thereby affording unparalleled flexibility in its subsequent utilization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimal investment strategies for distributed generation in distribution networks with real option analysis

Efficient and well‐timed investment in distributed generation (DG) in distribution networks in the electricity market environment presents a big challenge for distribution companies. In this study, a real option valuation framework is proposed to determine the optimal investment strategies for DG including the investment location, size, and timing. Within the proposed framework, the profit from investing in DG is modelled, where the benefits include the operation cost savings and capacity update deferral benefit compared with a no‐DG‐investment scenario over the study period. Future power demands and electricity prices are modelled as stochastic variables. The candidate DG investment plans are considered as multiple mutually exclusive options, and the corresponding managerial flexibility for seizing opportunities and mitigating risk of loss upon an unfavourable unfolding of future uncertainties is assessed with real option analysis using the extended least square Monte Carlo method. The distribution of future investment strategies and optimal initial investment threshold levels under various scenarios are analysed in a case study to demonstrate the characteristics of the proposed framework and methodology.

Zou, Bo↗

LARGE SCALE REFRIGERATION PLANT FOR GROUND TESTING THE JAMES WEBB TELESCOPE AT NASA JOHNSON SPACE CENTER

The James Webb Telescope is the successor to the Hubble Telescope and will be placed in an orbit of 1.5 million km from earth. Before launch in 2014, the telescope will be tested in NASA Johnson Space Center's (JSC) space simulation chamber, Chamber A. The tests will be conducted at deep space conditions. Chamber A's helium cryo-panels are currently cooled down to 20 K by two Linde 3.5 kW helium refrigerators. The new 12.5 kW, 20-K helium coldbox described in this paper is part of the upgrade to the chamber systems for this large test program. The Linde coldbox will provide refrigeration in several operating modes where the temperature of the chamber is being controlled with a high accuracy due to the demanding NASA test requirements. The implementation of two parallel expansion turbine strings and the Ganni cycle—Floating Pressure process results in a highly efficient and flexible process that minimizes the electrical input power. This paper will describe the collaboration and execution of the coldbox project.

42 ENGINEERING↗

Report for LANSCE Futures Spring 2021 Workshop Series

The Los Alamos Neutron Science Center (LANSCE) has a long and successful history of delivering high-impact science for NNSA missions. The breadth of science LANSCE delivers is enabled by a unique combination of beam power, flexibility, and authorization basis. Though LANSCE is entering its 50th year of operations, current plans for the stockpile require LANSCE capabilities beyond 2050. These requirements demand a technical conversation about the accelerator and the long-term scientific vision for the facility, so we convened a set of workshops to initiate that conversation. The LANSCE Futures workshops spanned three capability areas of LANSCE: dynamic radiography, scattering science, and nuclear science. Participants included the relevant experts from the programs sponsoring LANSCE, the experimentalists utilizing the end-stations, and accelerator systems experts. A final workshop combined the three focus areas to begin the conversation about capabilities that could meet future mission needs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

DRIRU II - The NASA standard high performance Inertial Reference Unit

This paper discusses the design configuration, performance and environmental capability of NASA's Dry Rotor Inertial Reference Unit (DRIRU II) for use in spacecraft precision attitude stabilization systems. The system is a self-contained, strapdown, dual rate sensing unit for spacecraft requiring high accuracy, reliability and low power consumption. Modular construction of the basic unit, arrangement of gyros, electronic modules and power supplies, signal flow, and mounting are described. DRIRU II is designed to meet specified performance requirements for a minimum of two years of operating time in orbit and a reliability prediction analysis is presented. The characteristics of test equipment are given together with the results of the environmental, radiation, and magnetic field sensitivity tests. DRIRU II may be modified for unique requirements and the rate range and resolution options are tabulated. The flexibility of the unit afforded by the use of dry tuned gimbal gyros and its modular construction results in a system capable of satisfying the demanding requirements of a broad spectrum of future applications. The units are planned for the Solar Max, Landsat-D and ASPS missions in the 1980's.

Irvine, R. B.↗

Evolutionary growth for Space Station Freedom electrical power system

Over an operational lifetime of at least 30 yr, Space Station Freedom will encounter increased space station user requirements and advancing technologies. The space station electrical power system is designed with the flexibility to accommodate these emerging technologies and expert systems and is being designed with the necessary software hooks and hardware scars to accommodate increased growth demand. The electrical power system is planned to grow from the initial 75 kW up to 300 kW. The Phase 1 station will utilize photovoltaic arrays to produce the electrical power; however, for growth to 300 kW, solar dynamic power modules will be utilized. Pairs of 25 kW solar dynamic power modules will be added to the station to reach the power growth level. The addition of solar dynamic power in the growth phase places constraints in the initial space station systems such as guidance navigation and control, external thermal, truss structural stiffness, computational capabilities and storage which must be planned-in in order to facilitate the addition of the solar dynamic modules.

Marshall, Matthew F.↗

Evolutionary growth for Space Station Freedom electrical power system

Over an operational lifetime of at least 30 yr, Space Station Freedom will encounter increased Space Station user requirements and advancing technologies. The Space Station electrical power system is designed with the flexibility to accommodate these emerging technologies and expert systems and is being designed with the necessary software hooks and hardware scars to accommodate increased growth demand. The electrical power system is planned to grow from the initial 75 kW up to 300 kW. The Phase 1 station will utilize photovoltaic arrays to produce the electrical power; however, for growth to 300 kW, solar dynamic power modules will be utilized. Pairs of 25 kW solar dynamic power modules will be added to the station to reach the power growth level. The addition of solar dynamic power in the growth phase places constraints in the initial Space Station systems such as guidance, navigation, and control, external thermal, truss structural stiffness, computational capabilities and storage, which must be planned-in, in order to facilitate the addition of the solar dynamic modules.

Marshall, Matthew Fisk↗

Process Developed for Fabricating Engineered Pore Structures for High- Fuel-Utilization Solid Oxide Fuel Cells

Solid oxide fuel cells (SOFCs) have tremendous commercial potential because of their high efficiency, high energy density, and flexible fuel capability (ability to use fossil fuels). The drive for high-power-utilizing, ultrathin electrolytes (less than 10 microns), has placed an increased demand on the anode to provide structural support, yet allow sufficient fuel entry for sustained power generation. Concentration polarization, a condition where the fuel demand exceeds the supply, is evident in all commercial-based anode-supported cells, and it presents a significant roadblock to SOFC commercialization.

Sofie, Stephen W.↗

Autonomous Contingency Management In Urban Air Mobility: The Communication Network Awareness Machine System

Next Generation Air Transportation System (NextGen) has begun the modernization of the nation’s air transportation system (NAS), with goals to improve system safety, increase operation efficiency and capacity, provide enhanced predictability, resilience and robustness [1]. The overall objective of the Air Traffic Management-eXploration (ATM-X) project is to facilitate the goals of NextGen by conducting research to enable the growing demand of new, mission variant, air vehicles with safe access to the NAS. The implementation and utilization of new and burgeoning technologies that are both flexible, scalable, and systematically user-focused are requisite for ATM-X to achieve its intention of NAS safe entry [2]. Researchers from NASA Langley’s Flight Deck Integration Team have developed a system architecture that would allow ATM-X to leverage the necessary capabilities of an Increasingly Autonomous System (IAS), machine-agent that will promote the safe access and operation of air vehicles within what has become the byproduct of NextGen modernization, a Net-Centric airspace architecture and an Urban Air Mobility (UAM) community. Conducting flight operations within this type of architecture constrains the human-agent’s natural ability by data management. When the massive volume of data, its types, and the acquisition speed at which the data is ingested is observed it becomes evident that the human-agent will be functioning at an operational disadvantage. Therefore, the development and integration of intelligent machine-agents into the flight deck are a necessary implementation to achieve ATM-X overall objective of safe access and operation in the NAS.

Urban Air Mobility↗

Dynamic regulation of water potential in Juniperus osteosperma mediates ecosystem carbon fluxes

Summary Some plants exhibit dynamic hydraulic regulation, in which the strictness of hydraulic regulation (i.e. iso/anisohydry) changes in response to environmental conditions. However, the environmental controls over iso/anisohydry and the implications of flexible hydraulic regulation for plant productivity remain unknown. InJuniperus osteosperma, a drought‐resistant dryland conifer, we collected a 5‐month growing season time series ofin situ, high temporal‐resolution plant water potential () and stand gross primary productivity (GPP). We quantified the stringency of hydraulic regulation associated with environmental covariates and evaluated how predawn water potential contributes to empirically predicting carbon uptake. Juniperus osteospermashowed less stringent hydraulic regulation (more anisohydric) after monsoon precipitation pulses, when soil moisture and atmospheric demand were high, and corresponded with GPP pulses. Predawn water potential matched the timing of GPP fluxes and improved estimates of GPP more strongly than soil and/or atmospheric moisture, notably resolving GPP underestimation before vegetation green‐up. Flexible hydraulic regulation appears to allowJ. osteospermato prolong soil water extraction and, therefore, the period of high carbon uptake following monsoon precipitation pulses. Water potential and its dynamic regulation may account for why process‐based and empirical models commonly underestimate the magnitude and temporal variability of dryland GPP.

Plant Sciences↗