Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Integrating Light Curve and Atmospheric Modeling of Transiting Exoplanets

Spectral retrieval techniques are currently our best tool to interpret the observed exoplanet atmospheric data. Said techniques retrieve the optimal atmospheric components and parameters by identifying the best fit to an observed transmission/emission spectrum. Over the past decade, our understanding of remote worlds in our galaxy has flourished thanks to the use of increasingly sophisticated spectral retrieval techniques and the collective effort of the community working on exoplanet atmospheric models. A new generation of instruments in space and from the ground is expected to deliver higher quality data in the next decade; it is therefore paramount to upgrade current models and improve their reliability, their completeness, and the numerical speed with which they can be run. In this paper, we address the issue of reliability of the results provided by retrieval models in the presence of systematics of unknown origin. More specifically, we demonstrate that if we fit directly individual light curves at different wavelengths (L-retrieval), instead of fitting transit or eclipse depths, as it is currently done (S-retrieval), the said methodology is more sensitive against astrophysical and instrumental noise. This new approach is tested, in particular, when discrepant simulated observations from Hubble Space Telescope/Wide Field Camera 3 and Spitzer/IRAC are combined. We find that while S-retrievals converge to an incorrect solution without any warning, L-retrievals are able to flag potential discrepancies between the data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron Activation and Thermoluminescent Detector Responses to a Bare Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 11, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

Miller, Thomas Martin↗

Graph-learning approach to combine multiresolution seismic velocity models

SUMMARY The resolution of velocity models obtained by tomography varies due to multiple factors and variables, such as the inversion approach, ray coverage, data quality, etc. Combining velocity models with different resolutions can enable more accurate ground motion simulations. Toward this goal, we present a novel methodology to fuse multiresolution seismic velocity maps with probabilistic graphical models (PGMs). The PGMs provide segmentation results, corresponding to various velocity intervals, in seismic velocity models with different resolutions. Further, by considering physical information (such as ray path density), we introduce physics-informed probabilistic graphical models (PIPGMs). These models provide data-driven relations between subdomains with low (LR) and high (HR) resolutions. Transferring (segmented) distribution information from the HR regions enhances the details in the LR regions by solving a maximum likelihood problem with prior knowledge from HR models. When updating areas bordering HR and LR regions, a patch-scanning policy is adopted to consider local patterns and avoid sharp boundaries. To evaluate the efficacy of the proposed PGM fusion method, we tested the fusion approach on both a synthetic checkerboard model and a fault zone structure imaged from the 2019 Ridgecrest, CA, earthquake sequence. The Ridgecrest fault zone image consists of a shallow (top 1 km) high-resolution shear-wave velocity model obtained from ambient noise tomography, which is embedded into the coarser Statewide California Earthquake Center Community Velocity Model version S4.26-M01. The model efficacy is underscored by the deviation between observed and calculated traveltimes along the boundaries between HR and LR regions, 38 per cent less than obtained by conventional Gaussian interpolation. The proposed PGM fusion method can merge any gridded multiresolution velocity model, a valuable tool for computational seismology and ground motion estimation.

Geochemistry & Geophysics↗

SU-FF-T-469: Energy Spectra Reconstruction From Beta Emitters: A Study of the Sr-90/Y-90 Case

Purpose: Reconstruction of the energy spectrum of a 90Sr/90Yradioactive source for low dose (~1Gy) radiation biology experiments. Method and Materials:Electrons originated from a 25 {micro}Ci 90Sr/90Yradioactive source were recently used in radio-biology experiments to study the response of cancer cells to low dose irradiation (~1Gy). The beam was separated into individual energies using a dipole magnet, the number of exited electronsmeasured by a scintillating fiber based detector and the dose obtained using double-layered EBT films. The dipole was constructed from two 5.08 x 5.08 x 2.54 cm{sup 3}permanent magnets separated by a distance of 2 cm and having a maximum field of about 5 kG at the center. The beam entered the magnet through a 1 cm diameter, 0.5 cm thick leaded glass collimator. The detector was an array of 16 blue shifted 1 mm thick scintillating fibers. A realistic Geant4 simulation was used to account for the energy loss while electrons propagate throughout the system. The incident energy spectrum was generated from the NIST-logft calculation. Results: The data was first compared with measurements using a pancake frisker detector for an overall general assessment of the data quality, giving an agreement to within 15%. The average deviation of the data/simulation ratio is {+-}2.5%. A comparison between the measured and simulated mean energies gives an agreement to within 1{sigma} (less than 0.3%). Conclusion: The simple system developed for this work can serve as a mean for an efficient way to accurately reconstruct the energy distribution of charged particle emitters as well as to assess expected dose delivery to biological systems. Such data can also be used to benchmark low energy physics processes implemented in simulation tools for medical physics purpose.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset

Lawrence Berkeley National Laboratory (LBNL) contracted the National Ecological Observatory Network Airborne Observation Platform (NEON AOP) to observe watersheds of interest near Crested Butte, CO with remotely sensed data including imaging spectroscopy. The flight box design encompassed the watersheds, and flight design targeted a minimum of 30% overlap between adjacent flight lines. The total area surveyed was 334 km2 across 72 lines. Flight lines were oriented north-south for consistency in solar illumination geometry. Seven days were required to cover the flight area. Some areas were flown additional times to improve data quality or temporal coincidence between airborne acquisitions and field sampling. In total, 102 lines were collected and can be downloaded here: https://portal.nersc.gov/wfsfa/doi-10-15485-1617204/. The instrument used for the acquisition was an Airborne Visible-Infrared Imaging Spectrometer - Next Generation (AVIRIS-NG), which records radiance within 426 contiguous spectral bands in the wavelength range from 380 to 2510 nm. The instrument was flown at a target aboveground altitude of 1000 m for a processed data spatial resolution of 1 m. These data are non-orthorectified, radiance data that require further processing prior to use as a surface reflectance data set.

2018 NEON and 2025 CHESS Campaigns↗

Observed physical processes in mechanical tests of PBX9501 and recomendations for experiments to explore a possible plasticity/damage threshold

This memo discusses observations that have been made in regards to a series of monotonic and cyclic uniaxial experiments performed on PBX9501 by Darla Thompson under Enhanced Surveilance Campaign support. These observations discussed in Section Cyclic compression observations strongly suggest the presence of viscoelastic, plastic, and damage phenomena in the mechanical response of the material. In Secton Uniaxial data analysis and observations methods are discussed for separating out the viscoelastic effects. A crude application of those methods suggests the possibility of a critical stress below which plasticity and damage may be negligible. The threshold should be explored because if it exists it will be an important feature of any constitutive model. Additionally, if the threshold exists then modifications of experimental methods may be feasible which could potentially simplify future experiments or provide higher quality data from those experiments. A set of experiments to explore the threshold stress are proposed in Section Exploratory tests program for identifying threshold stress.

36 MATERIALS SCIENCE↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Status Report FY20 Q2

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (like a redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed, most primary component have been fabricated, primary components are being assembled in preparation for initial testing, and procurement is continuing with the secondary system components. Since the FY19 THETA status report, The THETA primary system components are at Argonne National Laboratory (ANL) and have been dry assembled. The secondary sodium system for heat rejection from intermediate heat exchanger has all been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger has been procured.

42 ENGINEERING↗

Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Photometric redshift estimation with convolutional neural networks and galaxy images: Case study of resolving biases in data-driven methods

Deep-learning models have been increasingly exploited in astrophysical studies, but these data-driven algorithms are prone to producing biased outputs that are detrimental for subsequent analyses. In this work, we investigate two main forms of biases: class-dependent residuals, and mode collapse. We do this in a case study, in which we estimate photometric redshift as a classification problem using convolutional neural networks (CNNs) trained with galaxy images and associated spectroscopic redshifts. We focus on point estimates and propose a set of consecutive steps for resolving the two biases based on CNN models, involving representation learning with multichannel outputs, balancing the training data, and leveraging soft labels. The residuals can be viewed as a function of spectroscopic redshift or photometric redshift, and the biases with respect to these two definitions are incompatible and should be treated individually. We suggest that a prerequisite for resolving biases in photometric space is resolving biases in spectroscopic space. Experiments show that our methods can better control biases than benchmark methods, and they are robust in various implementing and training conditions with high-quality data. Our methods hold promises for future cosmological surveys that require a good constraint of biases, and they may be applied to regression problems and other studies that make use of data-driven models. Nonetheless, the bias-variance tradeoff and the requirement of sufficient statistics suggest that we need better methods and optimized data usage strategies.

79 ASTRONOMY AND ASTROPHYSICS↗

Inference of the linear matter power spectrum at z = 0 using DESI DR1 Full-Shape data

Measurements of galaxy distributions at large cosmic distances capture clustering from the past. In this study, we use a cosmological model to translate these observations into the present-day galaxy distribution. Specifically, we reconstruct the 3D linear matter power spectrum at redshift z = 0 using Dark Energy Spectroscopic Instrument (DESI) Year 1 (DR1) galaxy clustering data and Cosmic Microwave Background (CMB) observations, assuming the ΛCDM model, and compare it to the result assuming the w 0 w a CDM model. Building on previous state-of-the-art methods, we apply Effective Field Theory (EFT) modelling of the galaxy power spectrum to account for small-scale effects in the 2-point statistics of galaxy data. Implementation of the EFT approach improves the modelling of the galaxy power spectrum, providing a more robust consistency test of the assumed cosmological model. By casting both CMB and galaxy clustering observations, spanning distinct redshift regimes, into k-space, we can identify discrepancies between the datasets of different redshifts, which would indicate potential inaccuracies in the assumed expansion history. While previous studies have shown consistency with ΛCDM, this work extends the analysis with higher-quality data to further test the expansion histories of both ΛCDM and w 0 w a CDM. Our findings show that both ΛCDM and w 0 w a CDM provide consistent fits to the linear matter power spectrum recovered from DESI DR1 data.

cosmological parameters from LSS↗

Closure Report for Corrective Action Unit 408: Bomblet Target Area Tonopah Test Range (TTR), Nevada, Revision 0

This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 408: Bomblet Target Area (TTR), Tonopah Test Range, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. Corrective Action Unit 408 is located at the Tonopah Test Range, Nevada, and consists of Corrective Action Site (CAS) TA-55-002-TAB2, Bomblet Target Areas. This CAS includes the following seven target areas: • Mid Target • Flightline Bomblet Location • Strategic Air Command (SAC) Target Location 1 • SAC Target Location 2 • South Antelope Lake • Tomahawk Location 1 • Tomahawk Location 2 The purpose of this CR is to provide documentation supporting the completed corrective actions and data confirming that the closure objectives for the CAS within CAU 408 were met. To achieve this, the following actions were performed: • Review the current site conditions, including the concentration and extent of contamination. • Implement any corrective actions necessary to protect human health and the environment. • Properly dispose of corrective action and investigation wastes. • Document Notice of Completion and closure of CAU 408 issued by the Nevada Division of Environmental Protection. From July 2009 through August 2010, closure activities were performed as set forth in the Streamlined Approach for Environmental Restoration Plan for CAU 408: Bomblet Target Area, Tonopah Test Range (TTR), Nevada. The purposes of the activities as defined during the data quality objectives process were as follows: • Identify and remove munitions of explosive concern (MEC) associated with DOE activities. • Investigate potential disposal pit locations. • Remove depleted uranium-contaminated fragments and soil. • Determine whether contaminants of concern (COCs) are present. • If COCs are present, determine their nature and extent, implement appropriate corrective actions, and properly dispose of wastes. Analytes detected during the closure activities were evaluated against final action levels to determine COCs for CAU 408. Assessment of the data indicated COCs are not present at CAS TA-55-002-TAB2; therefore, no corrective action is necessary. No use restrictions are required to be placed on this CAU because the investigation showed no evidence of remaining soil contamination or remaining debris/waste upon completion of all investigation activities. The MEC was successfully removed and dispositioned as planned using current best available technologies. As MEC guidance and general MEC standards acknowledge that MEC response actions cannot determine with 100 percent certainty that all MEC and unexploded ordnance (UXO) are removed, the clean closure of CAU 408 will implement a best management practice of posting UXO hazard warning signs near the seven target areas. The signs will warn future land users of the potential for encountering residual UXO hazards. The DOE, National Nuclear Security Administration Nevada Site Office, provides the following recommendations: • A Notice of Completion to the DOE, National Nuclear Security Administration Nevada Site Office, is requested from the Nevada Division of Environmental Protection for closure of CAU 408. • Corrective Action Unit 408 should be moved from Appendix III to Appendix IV of the Federal Facility Agreement and Consent Order.

54 ENVIRONMENTAL SCIENCES↗

Biomass production in the Lower Mississippi River Basin: Mitigating associated nutrient and sediment discharge to the Gulf of Mexico

Here, a watershed model was developed using the Soil andWater Assessment Tool (SWAT) that simulates nitrogen, phosphorus, and sediment loadings in the Lower Mississippi River Basin (LMRB). The LMRB SWAT model was calibrated and validated using 21 years of observed flow, sediment, and water-quality data. The baseline model results indicate that agricultural lands within the Lower Mississippi River Basin (LMRB) are the dominant sources of nitrogen and phosphorus discharging into the Gulf of Mexico. The model was further used to evaluate the impact of biomass production, in the presence of riparian buffers in the LMRB, on suspended-sediment and nutrient loading discharge from the Mississippi River into the Gulf of Mexico. The interplay among land use, riparian buffers, crop type, land slope, water quality, and hydrology were anlyzed at various scales. Implementing a riparian buffer in the dominant agricultural region within the LMRB could reduce suspended sediment, nitrogen, and phosphorus loadings at the regional scale by up to 65%, 38%, and 39%, respectively. Implementation of this land management practice can reduce the suspended-sediment content and improve the water quality of the discharge from the LMRB into the Gulf of Mexico and support the potential production of bioenergy and bio-products within the Mississippi River Basin.

54 ENVIRONMENTAL SCIENCES↗

In vacuo X-ray data collection from graphene-wrapped protein crystals

A method is reported for collecting room-temperature data from protein crystals under vacuum by protecting them with a thin graphene layer. The measurement of diffraction data from macromolecular crystal samples held in vacuo holds the promise of a very low X-ray background and zero absorption of incident and scattered beams, leading to better data and the potential for accessing very long X-ray wavelengths (>3 Å) for native sulfur phasing. Maintaining the hydration of protein crystals under vacuum is achieved by the use of liquid jets, as with serial data collection at free-electron lasers, or is side-stepped by cryocooling the samples, as implemented at new synchrotron beamlines. Graphene has been shown to protect crystals from dehydration by creating an extremely thin layer that is impermeable to any exchanges with the environment. Furthermore, owing to its hydrophobicity, most of the aqueous solution surrounding the crystal is excluded during sample preparation, thus eliminating most of the background caused by liquid. Here, it is shown that high-quality data can be recorded at room temperature from graphene-wrapped protein crystals in a rough vacuum. Furthermore, it was observed that graphene protects crystals exposed to different relative humidities and a chemically harsh environment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗