Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Dynamic-Phasor Model of Transformer Inrush Simulation for Unbalanced Distribution System

Abstract— Power system stability is a critical concern, with respect to the increasing distributed energy resources, microgrids, and emphasis on enhancing resiliency. For stability analysis and evaluation, modeling and simulation capabilities are important. In this paper, the authors’ previous work on modeling transformer inrush dynamics is improved with a new formulation of the key equation that converts the dynamic-phasor into real-time value. Simulation results in an electromechanical time-scale are compared with PSCAD results in an electromagnetic time-scale to demonstrate the improvement. The impact of simulation step size is discussed. A bug in PSCAD transformer setting that leads to incorrect magnetizing flux and current under Delta winding type is identified and reported. In addition, explanations and analysis are provided on two modeling techniques utilized since the previous work. This work is being incorporated into the next release of GridLAB-D. The improved transformer inrush calculation enables more accurate predictions of current amplitudes for analyzing the dynamics of distribution operation and control.

power transformers, power system simulation, satur↗

How the NRC modernized its digital I&C infrastructure and where it goes from here

The NRC first formally developed infrastructure for the review of digital instrumentation and control (I&C) systems in the 1990’s. Although, the current U.S. fleet of nuclear power plants were originally designed and constructed with analog systems, the U.S. nuclear industry has for more that thirty years been working to upgrade these older systems with modern digital systems. Digital systems have many advantages but also pose different engineering challenges and need to be reviewed by the Nuclear Regulatory Commission (NRC) in a different way. Because of this the NRC started looking at its regulatory infrastructure to see if changes needed be made to support the expanded safe use of digital systems in nuclear power plants. Several efforts in the 1990’s included a review by the National Academies’ National Research Council, a review of the impact of potential new digital systems by the NRC staff as a result of advanced reactor designs and the NRC staff’s update to the I&C section of the Standard Review Plan (SRP) (Ref 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Balanced current-source inverter

A switching circuit for a current source inverter includes a first inverter leg, a second inverter leg, and a controller. The first inverter leg includes a first reverse-voltage-blocking (RB) switch, a second RB switch, and a third RB switch that are connected in series between a first bus line and a second bus line. The second inverter leg includes a fourth RB switch, a fifth RB switch, and a sixth RB switch are connected in series between the first bus line and the second bus line. The controller is configured to control a switch between an on-state and an off-state for each RB switch. When in the on-state, a reverse voltage is blocked by a respective RB switch, and a current with a positive polarity is conducted through the respective RB switch. When in the off-state, a voltage and the current are blocked by the respective RB switch.

Jahns, Thomas Merlin↗

Molten Salt Tritium Transport Experiment: A Versatile Fluoride Salt Loop for Validation of Tritium Transport Phenomena

Tritium is generated in Molten Salt Reactors (MSRs) from neutron capture by lithium and other constituents of the molten salt FLiBe. Tritium is a unique radionuclide as it readily permeates through hot structural materials. Thus, any material in contact with tritium laden molten salt is a potential pathway for release. Understanding tritium transport and devising adequate control strategies is necessary for the safe operation of MSRs. The Molten Salt Tritium Transport Experiment (MSTTE) is a forced-convection fluoride salt loop with the capability to inject hydrogen isotopes into flowing molten salt and to measure transport phenomena such as permeation through metals and evolution from free-surfaces. MSTTE is designed to be versatile to test potential control technology in future campaigns. This report focuses on the current design and analysis of MSTTE. Custom designed and fabricated experiment components such as the hydrogen injection system, permeation test section, diagnostics, and gas distribution system are discussed in detail. System-level tritium transport modeling using the System Analysis Module investigates experiment parameters such as hydrogen source terms, salt flow rate, and salt temperature. Computational fluid dynamics of the salt flow in the permeation test section informs design choices to establish fully developed flow in the measured permeation zone.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY23 ION Based Approaches to Address Labor and Knowledge Retention

This study will seek to outline the current problem facing the nuclear industry related to staffing, training, and retaining the necessary workforce for long-term sustainability. A review of published reports and knowledge gained by working in the nuclear energy sector will form the basis for this scoping study. This study will not seek to draw any conclusions regarding the underlying causes of these personnel issues but will attempt to ask questions and help outline future research. The Integrated Operations for Nuclear business model provides opportunities to partially mitigate some of the current issues facing staffing the nuclear fleet. Upgrading safety and control systems from analog to digital as advocated by the Integrated Operations for Nuclear process allows the nuclear facility to compete for the best and brightest candidates and offers them a broad and sustainable career path where their skills can be valued and utilized in the broader industrial sectors. This study will seek to identify the primary reasons that the nuclear industry is facing this labor crisis and seek to identify possible solutions that will be fully evaluated in future research.

42 ENGINEERING↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗

Intelligent Surrogate Model Development: Boosting Computational Efficiency for Autonomous Control of Advanced Reactors

Advanced reactors promise enhanced safety, greater efficiency, and waste reductions. To fully realize these benefits, it is crucial to address the need for autonomous or semi-autonomous control systems that require fewer operators. This research primarily supports the MARVEL autonomous control system, which requires real-time operation. However, the current RELAP5 reactor thermal hydraulic transient simulation is excessively time-consuming. Therefore, this study aims to leverage deep learning techniques to develop a surrogate model, providing a more efficient and accurate alternative for real-time performance. The model was trained using a combination of one-timestep prediction and scheduled sampling. It was then used for recursive prediction of the reactor state. This developed surrogate model significantly improves computational efficiency, achieving a 12 times acceleration.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time-Varying Output Delay Compensation-A Model-Free Approach and its Application on Cooperative On-Ramp Merging

This paper presents a model-free approach to compensate for time-varying output delay in networked control systems. The proposed architecture combines a model-free observer and the Smith predictor. The model-free observer estimates the current state while handling modeling errors and uncertainties of the system. The Smith predictor moves the effect of time delay outside the control closed-loop using the estimated delayed output and the actual output of the plant. The proposed method is applied to a cooperative on-ramp merging problem. First, an ultra-local model predictive control is implemented to provide a computationally efficient online speed planner agnostic to the vehicle dynamics. After that, a model-free observer is designed to estimate the current state. Finally, the proposed architecture is tested against a time-varying output delay with an upper bound of 200 milliseconds. The results demonstrate the effectiveness of the proposed method with improved tracking of intervehicle distance.

Waleed khan, Muhammad [The University of Texas at ↗

Projecting Stratocumulus Transitions on the Albedo—Cloud Fraction Relationship Reveals Linearity of Albedo to Droplet Concentrations

Satellite images show solid marine stratocumulus cloud decks (Sc) that break up over the remote oceans. The Sc breakup is initiated by precipitation and is accompanied by a strong reduction in the cloud radiative effect. Aerosol has been shown to delay the Sc breakup by postponing the onset of precipitation, however its climatic effect is uncertain. Here we introduce a new approach that allows us to re-cast currently observed cloud cover and albedo to their counterfactual cleaner world, enabling the first estimate of the radiative effect due to delayed cloud breakup. Using simple radiative approximation, the radiative forcing with respect to pre-industrial times due to delayed Sc breakup is –0.39 W m –2 . The radiative effect changes nearly linearly with aerosol due to the droplet concentration control on the cloud cover, suggesting a potentially accelerated warming if the current trend of reduction in aerosol emissions continues.

54 ENVIRONMENTAL SCIENCES↗

Reconfigurable Electrical Networks within a Conductive Hydrogel Composite

Soft materials that exhibit compliance, programmability, and reconfigurability can have a transformative impact as electronic skin for applications in wearable electronics/soft robotics. There has been significant progress in soft conductive materials; however, achieving electrically controlled and reversible changes in conductivity and circuit connectivity remains challenging. To overcome this limitation, a soft material architecture with reconfigurable conductive networks of silver flakes embedded within a hydrogel matrix is presented. The conductive networks can be reversibly created/disconnected through various stimuli, including current, humidity, or temperature. Such stimuli affect electrical connectivity of the hydrogel by controlling its water content, which can be modulated by evaporation under ambient conditions (passive dehydration), evaporation through electrical Joule heating (active dehydration), or absorption of additional water (rehydration). The resulting change in electrical conductivity is reversible and repeatable, endowing the composite with on-demand reconfigurable conductivity. To highlight this material's unique properties, it is shown that conductive traces can be reconfigured after severe damage and revert to lower conductivity after rehydration. Additionally, a quadruped robot is demonstrated that can respond to stimuli by changing direction following exposure to excess water, thereby achieving reprogrammable locomotion behaviors.

36 MATERIALS SCIENCE↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Quadrupling the depairing current density in the iron-based superconductor SmFeAsO1–xHx

Abstract Iron-based 1111-type superconductors display high critical temperatures and relatively high critical current densities J c . The typical approach to increasing J c is to introduce defects to control dissipative vortex motion. However, when optimized, this approach is theoretically predicted to be limited to achieving a maximum J c of only ∼30% of the depairing current density J d , which depends on the coherence length and the penetration depth. Here we dramatically boost J c in SmFeAsO 1– x H x films using a thermodynamic approach aimed at increasing J d and incorporating vortex pinning centres. Specifically, we reduce the penetration depth, coherence length and critical field anisotropy by increasing the carrier density through high electron doping using H substitution. Remarkably, the quadrupled J d reaches 415 MA cm –2 , a value comparable to cuprates. Finally, by introducing defects using proton irradiation, we obtain high J c values in fields up to 25 T. We apply this method to other iron-based superconductors and achieve a similar enhancement of current densities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Continental United States may lose 1.8 petagrams of soil organic carbon under climate change by 2100

Abstract Aims High‐resolution information on soils’ vulnerability to climate‐induced soil organic carbon (SOC) loss can enable environmental scientists, land managers, and policy makers to develop targeted mitigation strategies. This study aims to estimate baseline and decadal changes in continental US surface SOC stocks under future emission scenarios. Location Continental United States. Time period 2014–2100. Methods We used recent SOC field observations ( n = 6,213 sites), environmental factors ( n = 32), and an ensemble machine learning (ML) approach to estimate baseline SOC stocks in surface soils across the continental United States at 100‐m spatial resolution, and decadal changes under the projected climate scenarios of Coupled Model Intercomparison Project Phase Six (CMIP6) earth system models (ESMs). Results Baseline SOC projections from ML approaches captured more than 50% of variability in SOC observations, whereas ESMs represented only 6–16% of observed SOC variability. ML estimates showed a mean total loss of 1.8 Pg C from US surface soils under the high‐emission scenario by 2100, whereas ESMs showed no significant change in SOC stocks with wide variation among ESMs. Both ML and ESM predictions agree on the direction of SOC change (net emissions or sequestration) across 46–51% of continental US land area. These differences are attributable to the high‐resolution site‐specific data used in the ML models compared to the relatively coarse grid represented in CMIP6 ESMs. Main conclusions Our high‐resolution estimates of baseline SOC stocks, identification of key environmental controllers, and projection of SOC changes from US land cover types under future climate scenarios suggest the need for high‐resolution simulations of SOC in ESMs to represent the heterogeneity of SOC. We found that the SOC change is sensitive to key soil related factors (e.g. soil drainage and soil order) that have not been historically considered as input parameters in ESMs, because currently more than 95% variability in the SOC of CMIP6 ESMs is controlled by net primary productivity, temperature, and precipitation. Using additional environmental factors to estimate the baseline SOC stocks and predict the future trajectory of SOC change can provide more accurate results.

54 ENVIRONMENTAL SCIENCES↗

Deciphering the Dynamic Balance Between Solvation Strength and Polysulfides Reaction Heterogeneity in Practical Lithium‐Sulfur Batteries

Achieving stable interfacial chemistry in lithium–sulfur batteries under practical conditions remains a key barrier to commercialization. Here, we demonstrate that interfacial dynamics can be effectively regulated by coupling solvation-power control with intrinsic heterogeneity of sulfur redox chemistry through the introduction of a weakly solvating fluorinated cosolvent, LIB 1200ET (1200ET). Compared with conventional fluorinated ethers, 1200ET efficiently shifts Li + solvation environment toward a more non-coordinated configuration at low volume fractions, enabling substantial solvation modulation without significantly impairing sulfur redox kinetics. This solvation transition weakens Li + –solvent interactions while strengthening Li + –anion and Li + –lithium polysulfide (LPS) coordination, suppressing LPS solubility and promoting reconstruction of solid–electrolyte interphase (SEI). Regulated LPS chemistry, together with 1200ET, leads to formation of a S 4+ -rich, LiF-reinforced SEI with enhanced ionic conductivity and mechanical robustness. Spatially resolved sulfur K-edge X-ray absorption spectroscopy on pouch cells reveals pronounced current-density-dependent chemical heterogeneity, distinguishing kinetically dominated and solvation-controlled regions. Under practical conditions (3.7 mg cm −2 sulfur loading, E/S = 6 µL mg −1 ), a single-layer pouch cell delivers 527 mAh g −1 over 200 cycles at C/3, while an Ah-level multilayer pouch cell achieves an energy density of 358 Wh kg −1 . These results establish non-coordinating cosolvent-driven solvation engineering as a scalable strategy for practical Li–S batteries.

36 MATERIALS SCIENCE↗

A variable X-ray chopper system for phase-sensitive detection in synchrotron X-ray scanning tunneling microscopy

An ultra-high-vacuum compatible X-ray chopper system has been designed, constructed and integrated into the XTIP beamline at the Advanced Photon Source at Argonne National Laboratory. The XTIP beamline can operate at soft X-ray energies from 400 eV to 1900 eV while providing a focused beam down to about 10 µm × 10 µm into the synchrotron X-ray scanning tunneling microscopy (SX-STM) endstation instrument. The X-ray chopper is a critical component for separating topographic information from chemical information in SX-STM through phase-sensitive current detection. Depending on the experimental needs, the modulation frequency can be controlled from 100 Hz to 10 kHz. In addition, the chopper system is fully bakeable and can achieve a base pressure of 10 -10 mbar. Facilities for active water cooling have been designed, but passive cooling through copper braids has been shown to be sufficient at standard chopping frequencies. Using an Fe/Al 2 O 3 /CoAl(111) sample, the separation of the SX-STM current into a chemical component and a stable feedback signal is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precipitation in Northeast Mexico Primarily Controlled by the Relative Warming of Atlantic SSTs

Abstract Reconstructing hydroclimate over the Common Era is essential for understanding the dominant mechanisms of precipitation change and improving climate model projections, which currently suggest Northeast Mexico will become drier in the future. Tree‐ring reconstructions have suggested regional rainfall is primarily controlled by Pacific sea‐surface temperatures (SSTs). However, tree ring records tend to reflect winter‐spring rainfall, and thus may not accurately record total annual precipitation. Using the first multiproxy speleothem record spanning the last millennium, combined with results from an atmospheric general circulation model, we demonstrate mean annual rainfall in Northeast Mexico is highly sensitive to Atlantic SST variability. Our findings suggest future precipitation in Northeast Mexico is more dependent upon the warming of Tropical Atlantic SSTs relative to the Tropical Pacific.

Wright, Kevin T.↗