Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Assessment of Governing Heat and Mass Transfer Coefficients for Cryogenic No-Vent Top-Off Modeling

No-vent fill / no-vent top-off (NVF/NVTO) is a method to enable the trans-fer of cryogenic propellants without the need to vent. Transferring propellants inmicrogravity environments is necessary to support the long-duration space missionsplanned for the coming decades. A key developmental milestone to developing thiscapability fully is the simulation and experimentation of NVF/NVTO in 1-g settings.This work seeks to advance the former by assessing the effectiveness of different heattransfer correlations used in a 1-g non-equilibrium model. Heat transfer correlationsfor natural convection and two-phase boiling heat transfer are compared against ex-perimental results for 34 different tests. Two distinct experiments, comprised of 21tests, are presented in detail here. These tests cover a variety of different injectionmethods, receiver tank geometries, receiver tank materials, cryogenic propellants, andinitial tank states. Overall for the cases tested in this work, the model was able topredict the pressure response within the receiver tank to a mean absolute percentageerror of 25.9%. The temperature response error rate was 29.5% and 24.9% for wall-gasand two-phase nodes, respectively. Compared to the worst case correlation set tested,the pressure prediction error rate represents a 31% improvement. For the cases pre-sented in this work, the mean pressure prediction error rate was 15.5%. Future workcould evaluate the effectiveness of this model against experiments conducted withdifferent propellants or different initial conditions. In its current form, however, themodel can still be used to help reduce design and testing time for 1-g experiments,enabling the quicker iteration that is necessary to meet the technological demands offuture space missions.

No-Vent Top Off↗

Liquefaction of Cryogenic Fluids for Production and Storage of Commodities on Extra-Terrestrial Surfaces

The Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) activity has been investigating concepts for the liquefaction of cryogenic fluids produced on the surface of the Moon and Mars. CryoFILL consists of four activities: liquid nitrogen liquefaction testing that was completed in 2019, liquid oxygen liquefaction testing planned to begin in early 2022, fiber-optic sensor temperature measurement system development, and lightweight vacuum jacketed systems designed for the atmosphere of Mars. Additional activities include the development and validation of numerical modeling systems at three stages: thermodynamic models of the liquefaction process for basic energy/mass estimates, nodal models to predict liquefaction tank system level performance, and computational fluid dynamics to assess fluid phenomena occurring within the tank, specifically condensation and stratification within the ullage. These developments form a combined liquefaction and storage solution to support Lunar and Martian exploration. Key testing results from liquid nitrogen testing as well as plans for liquid oxygen testing will be discussed including key sensitivities from analytical evaluation of completed test results. Progress on the development and improvements on fiber optic sensor testing and developments will also be provided. Finally, work on the progress of the lightweight vacuum jacketed systems being co-developed by NASA and industry will be summarized.

Liquefaction↗

NASA Meeting on Cryogenic Fuel Systems for Aircraft: Overview of Previous Workshops and Studies

NASA is holding a meeting on Cryogenic Fuel Systems for Aircraft. To help guide meeting focus, a brief review of previous studies and workshops is included delineated among airframe, propulsion, and fuel system topics. Information is limited to cryogenic fuel-related information, such as liquid methane (LNG) or liquid hydrogen. Older studies (from 1950s) as well as present efforts are briefly highlighted. A more comprehensive listing of recent efforts that may be pertinent are included in the bibliography.

Cryogenic fuel systems↗

Operational Techniques in Microgravity for Cryogenic Fluid Management

Management of cryogens in microgravity is a critical challenge for exploration missions to the Moon and Mars. Operational strategies to aid in cryogenic fluid management (CFM) are proposed and demonstrated using computational fluid dynamics simulations. Application of axial settling thrust is an essential – but potentially expensive – tool for CFM. Demonstrations show that its utilization and timing are important during certain unsettling events, such as engine cutoff. At other times, substantial savings can be realized by reducing the average acceleration (through pulsing thrusters, for example). If the metric for reaching a settled condition is a particular number of slosh periods, then fewer settling resources are needed with a lower acceleration. Alternatively, if a target wave amplitude is the settling objective, then a lower average acceleration will also allow for a higher allowable amplitude for the same heat transfer. Savings can also be obtained by rolling the vehicle, which can mitigate lateral slosh. Advantages and disadvantages of anti-slosh baffles are also discussed along with practical examples of their impact on CFM and ullage collapse. Ullage collapse examples are presented along with recommendations for slewing a vehicle with angular and translational acceleration to mitigate mixing between liquid and ullage.

Cryogenic Fluid Management↗

Improvement of Pressure Sensitive Paint in A Cryogenic Oxygen-Poor Environment

This report details specific improvements to the use of Pressure Sensitive Paint (PSP) in an oxygen-poor environment, with an emphasis on cryogenic PSP in the National Transonic Facility (NTF). For this work, several improvements to the application of PSP and data acquisition have been investigated in the 0.3-m Transonic Cryogenic Tunnel (generally considered a pilot facility for the NTF) and these results will be presented. In addition, several improvements to the existing PSP system at NTF are presented as well as a brief section on further improvements that can be investigated.

Cryogenic ground testing↗

Recent Concept Study for Cryogenic Fluid Management to Support Opposition Class Crewed Missions to Mars

NASA recently completed a mission concept study to evaluate the feasibility and propulsion technology development requirements for reduced travel duration crewed missions to Mars. A high-level goal of the study was to minimize the health impact on the crew caused by the space environment. This was implemented in the study by limiting the crew to a total of approximately-two years of in-space operations and travel time. For the initial mission, the crew would stay about 30 days on the Martian surface. The propulsive demands of such a mission are immense, and the study identified two advanced propulsion options with the potential to meet the mission requirements—both options rely on nuclear fission to provide efficient propulsive energy. One propulsion option was a nuclear electric propulsion (NEP)/Chem Hybrid, with a reactor and energy conversion system powering xenon propellant ion thrusters to provide an efficient, but lower-thrust, push for most of the mission duration. This concept also relied on a liquid oxygen/liquid methane (LO2/LCH4) chemical propulsion stage to provide high thrust for maneuvers while near the Earth and Mars. The second propulsion option was nuclear thermal propulsion (NTP), in which the reactor heats liquid hydrogen (LH2) propellant to expand through a nozzle for thrust at about twice the efficiency of the best chemical propulsion systems. Both vehicle concepts rely on storing large amounts of cryogenic propellant (either LO2/LCH4 or LH2) for multiple years in space without loss, far exceeding state-of-the-art capability. To enable this new capability, the team assumed the use of several advanced cryogenic fluid management (CFM) technologies and analyzed the integrated system performance. This included considering the vehicle-level effects of the size, mass, and power requirements of these CFM elements. Further, the team evaluated the development required to enable such a mission in the mid-2030 s and determined that it was feasible. The paper elaborates on the assumed CFM technologies, provides key analysis results, and illustrates the feasibility of technology development for the proposed solutions to the CFM challenges for each propulsion concept.

cryogenic propellant↗

Recent Advancements in Electrical Capacitance Mass Gauging for Cryogenic PropellantTanks

The current lack of unsettled mass gauging is a key roadblock for many space activities, such as orbital refueling, missions to the Moon and Mars, and nuclear thermal and nuclear electric propulsion technologies. Liquid can form any one of an infinite number of configurations in microgravity, such as floating in globs or accumulating on tank surfaces in discontiguous volumes, or both. Capacitive sensing requires no moving parts and dissipates close to zero heat, making it an ideal candidate for cryogenic fluid mass gauging in settled and unsettled configurations. Capacitive sensing has a history of proven use in space propellant tanks, including tanks on the space shuttle, Saturn V, and the Apollo Lunar Excursion Module. Modern capacitive sensor technology allows using the entire tank as the capacitor volume by placing electrodes on the tank walls and propellant management surfaces. Capacitance is directly related to density, and therefore to mass for fixed volumes. In this presentation, we discuss the concepts behind whole-tank capacitance mass gauging and associated engineering challenges. We describe recent efforts to develop a micro-g unsettled cryogenic mass gauge using whole-tank capacitance sensing, including the development of test beds, electronics, and algorithms. We describe several mathematical processing techniques, including empirical-based averaging, electrical capacitance volume tomography, and spatial regularization. A modeling study, performed using settled configurations in gravity and no gravity, and with a set of 100 random fluid configurations, has indicated that spatial regularization, in which capacitance measurements are weighted to account for non-uniform electric fields, yields a mass fraction accuracy of 8% for any fluid configuration. Such a sensor is expected to operate in real time with a sampling frequency of at least 1 kHz.

cryogenic↗

CFD Modeling of a Cryogenic Methane Drain Test with and without Induced Sloshing

Current planned NASA missions to the Moon and Mars involve the transfer of cryogenic propellants in orbit. These activities require large amounts of cryogenic propellant and the ability to transfer these fluids from one tank to another in an efficient manner. Predicting the pressurant required for the supply tank pressurization during the initial pressurization and expulsion process will be important to understand priori to reduce propellant margin.

Low Gravity Fluid Modeling↗

Thermal Desktop Modeling of the RRM3 On-Orbit Cryogenic Methane Storage and Active Cooling Experiment

The storing of cryogenic propellants is an enabling technology for NASA as it moves to expand future missions into low Earth orbit (LEO) and beyond. The Robotic Refueling Mission–3 (RRM3) experiment launched in 2018 and was designed to demonstrate tank self-pressurization during storage and active cooling of liquid methane in microgravity. Creating accurate models using existing datasets from flight experiments such as RRM3 is a vital step toward developing appropriate modeling tools to form pre-test predictions for future flight systems. The goal of this work was to create a working model in Thermal Desktop of the RRM3 source Dewar during the microgravity self-pressurization experiment. The pressure rise, temperature distribution of the fluid inside the tank, and the wall temperatures were all tracked and compared with test data. Initial results show good agreement between each of these metrics and the experimental results. This work is ongoing and will yield further insights into the thermal behavior of cryogens in microgravity.

Tank self-pressurization↗

NASA Cryogenic Fluid Management Flight Demonstration Summary: SpaceX 2020 Tipping Point

NASA Science and Technology Mission Directorate is investing in advancement of on-orbit cryogenic fluid management technologies by partnering with industry through Tipping Point contracts with the primary objective of reducing development costs and schedules for infusion into long duration missions utilizing cryogenic propellant. SpaceX was selected as a partner in 2020 to conduct a demonstration of CFM technologies on a Starship Mission. This presentation provides a summary of the top-level goals and objectives of this contract and how NASA has structured this partnership.

cryogenic fluid management↗

Nodal Modeling of Submerged Helium Injection Pressurization of a Cryogenic Propellant Tank

Subcooling of cryogenic propellant by helium injection is one of the most effective methods for suppressing bulk boiling and keeping subcooled propellant conditions for pre-launch, launch, and post-launch pressurization applications. For tank pressurization, submerged helium injection can substantially reduce helium consumption by infusing gaseous propellant into the tank ullage. This paper describes a thermodynamic model of the helium bubbling process in liquid oxygen to estimate the amount of oxygen vapor absorbed by the rising helium bubbles and the amount of subcooling of liquid oxygen due to evaporative heat and mass transfer. The physics of helium dissolution during the pressurization process is also modeled, primarily for liquid hydrogen propellant where the dissolution is more significant. The analyses were performed in a simulation model of tank pressurization built with Generalized Fluid System Simulation Program (GFSSP), a general-purpose flow network code developed at NASA/Marshall Space Flight Center. The numerical predictions of subcooling have been compared with the experimental data of Cho et al. which investigated the propellant subcooling effect as a function of system pressure, helium injection temperature, and flowrate for a non-drained submerged injection system. The numerical predictions of helium consumption have been compared with the test data from a NASA Centaur test vehicle which included both direct and submerged injection with draining of propellants. Hydrogen propellant testing of the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) conducted at NASA/Glenn Research Facility was also analyzed. The data used for the model validation were taken in 1-g, but the model was developed to be applicable in both multi-g and micro-g environments.

tank pressurization↗

Electrified Aircraft Propulsion Integration Concepts: Primary Fuel Cells and Cryogenic Hydrogen Storage

This presentation leverages lessons learned from the multiple activities funded by the National Aeronautics and Space Agency (NASA) to convey development paths for implementing an Electrified Aircraft Propulsion (EAP) system powered by primary fuel cells systems and fueled by cryogenically stored hydrogen. To reduce greenhouse gas emissions associated with all aspects of hydrogen-fueled aviation, this work minimizes required energy and time per payload distance at take-off so as to reduce emissions associated with ground operations and the production, liquefaction, transfer, and storage of hydrogen. The approach targets efficient system integration, maximizing hydrogen utilization efficiency, maximizing power system efficiency, and viable operational concepts for delivered payload distances. The discussion outlines the performance and compliance challenges revealed by analyses of current fuel cell and cryogenic management technologies. The conclusion offers potential mitigation strategies to the identified the performance and compliance challenges.

Fuel Cell↗

Simulations of Cryogenic Line Chilldown with Advanced Sub-Grid Wall Boiling Models

A meso-scale model developed at MIT [2][11] for boiling processes in water was adapted for cryogens and demonstrated for chilldown of propellant transfer lines in both liquid nitrogen and hydrogen. The sub-grid boiling model accurately captures the contributions to heat transfer from the generation of bubble nuclei, growth, and interaction of the bubbles in the microlayer as well as quenching of the boiling surface following bubble departure. It was adapted for cryogenic fluids using thermodynamic scaling concepts taking into account non-dimensional pressures and temperatures that are scaled by the corresponding critical values for the fluid. The boiling model was demonstrated for line chilldown in liquid nitrogen (Darr et al. [6]). The predicted wall temperature at which quenching occurs was close to the test data while the slope of the temperature curve after quenching is initiated, showing a steeper variation than the test data. Simulations were also performed for liquid hydrogen by simulating experiments of Hartwig et al. [7]. Chilldown times in liquid hydrogen are much more rapid due to higher heat transfer in the film boiling regime and accounting for the higher turbulence levels were found to be important. Furthermore, at the much lower fluid temperatures in liquid hydrogen flows, accounting for the variable thermal properties of the solid material is critical and has a dramatic impact on the quench times. The need for additional studies to better understand the evolution of the quench front in liquid hydrogen was noted.

Computational Fluid Dynamics↗

Validation & Verification of CFD Models for Cryogenic Fluid Management of Propellant Tanks in Space

This article describes the need and the strategy for CFD model development, validation, and verification for Cryogenic Fluid Management (CFM) of Propellant Tanks in Space. It describes the type of CFD models that must be developed to address the future needs of Space CFM. It also discusses the two classes of experiments currently used to validate the fidelity of the CFD models. These two experiment classes are: (a) the small-scale simulant fluid science experiments that are equipped with scientific diagnostics to elucidate the underlying two-phase fluid physics of the CFM processes; and (b) the large-scale cryogenic experiments that assess the engineering performance of the propellant tank for storage and transfer. The current status of the CFD model development and validation is briefly assessed by presenting examples of segregated two-phase flow problems that have been successfully modeled. The future model development directions for CFM situations involving more complex interpenetrating phases are also defined.

Cryogenic Fluid Management↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Joule-Thomson Cryogenic Nitrogen Orifice Flows

The Joule-Thomson Effect involves the expansion of a fluid through a throttling device, often a simple orifice, resulting in a change in the fluid's temperature. It has been leveraged in the design and analysis of Thermodynamic Vent Systems and integrated into injector designs for cryogenic no-vent fill tank-to-tank transfer testing. There is a scarcity of comprehensive data available to model the phenomenon effectively using tools such as GFSSP for cryogenic nitrogen flows. This experiment aims to model the Joule-Thomson effect of liquid nitrogen through seven traditionally manufactured, sharp-edged orifices manufactured by O’Keefe and three additively manufactured (AM) orifices manufactured by Cumberland Additive. The traditional orifice sizes were 0.016, 0.02, 0.024, 0.032, 0.037, and 0.04 inch in diameter. The three additive orifices had diameters with target/nominal sizes equal to the 0.016, 0.024, and 0.04 inch O’Keefe orifices. However, the actual diameters of the AM orifices were found to be 0.014, 0.024, and 0.035 inches due to additive manufacturing restrictions. Water was flowed through the orifices to verify that their flow coefficients matched published values and to establish flow coefficients for the AM orifices. Liquid nitrogen was flowed through the orifices in a separate test apparatus. The liquid nitrogen started as a subcooled liquid upstream of the orifice and transitioned into a two-phase gas-liquid mixture after passing through each orifice. The upstream pressure was set to 29 psia, 34 psia, 39 psia, and/or 42 psia or 44 psia. The pressure, temperature, and flow rate were measured upstream and downstream of the orifice for three trials at each set point. The average volumetric flow rate and Joule-Thomson Coefficients were calculated from this data. The AM orifices and traditionally manufactured orifices displayed similar results. This data will refine the dataset GFSSP uses to model the J-T Effect more accurately.

Joule-Thomson↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Modeling Self-Pressurization and Spray Bar Pressure Control of A Cryogenic Storage Tank in Normal Gravity

This paper presents computational fluid dynamics (CFD) models for simulating self-pressurization and spray-bar pressure control processes in a large-scale liquid hydrogen storage tank under normal gravity conditions. For self-pressurization, the model employs the kinetics-based Schrage equation alongside the volume-of-fluid (VOF) method to account for interfacial mass transfer. The CFD predictions of pressure and temperature are compared with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) experiment, and the predicted interfacial mass transfer rates are also presented. A CFD model simulating pressure control using a spray bar has also been developed. An Eulerian-Lagrangian approach models the interactions between discrete droplets and the continuous ullage (vapor) phase. The spray model is coupled with the VOF method by tracking droplets in the ullage and removing them when they reach the liquid interface. The T-sat model calculates droplet-ullage heat and mass transfer, where droplets warm up to the saturation temperature corresponding to the ullage vapor pressure before evaporating while remaining at the saturation temperature. The evolution of tank pressure, vapor temperature, and liquid temperature predicted by the CFD model is validated against data from the MHTB spray-bar mixing experiment. Overall, the CFD models agree with experimental data, demonstrating their capability to simulate self-pressurization and pressure control processes in large-scale cryogenic storage tanks. These models can be valuable tools for designing and optimizing cryogenic fluid management systems in future applications.

Computational Fluid Dynamics↗