Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Ultra-Sensitive Measurements of Large-Volume Radioxenon Samples Using an Ultra-Low-Background Proportional Counter (ULBPC) (Final Report)

This project investigated the feasibility of analyzing radioxenon samples in much larger quantities than currently used by the International Monitoring System (IMS). There is interest within the PTS and the international community in the ability to obtain xenon samples using the output of industrial oxygen plants, which could provide samples that are larger by three orders of magnitude, or more, than those currently provided by IMS stations. Such samples would best be analyzed using internal-source gas proportional counters, though the details of that approach and its sensitivity and limits were previously not examined. This report details the outcomes of a task designed to 1) analyze xenon radioisotope data collected previously via internal-source gas proportional counting and 2) collect additional gas proportional counter measurements to determine feasible gas blends for large volume xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MIT OSO-7 X-ray experiment. A five color survey of the positions and time variations of cosmic X-ray sources

The all-sky, X-ray measurements are made in five broad energy bands from 0.5 to 60 keV with X-ray collimators of one and three degree FWHM response. Working with the onboard star sensor source locations may be determined to a precision of plus or minus 0.1 deg. The experiment is located in wheel compartment number three of the spacecraft. A time division logic system divides each wheel rotation into 256 data bins in each of which X-ray counts are accumulated over a 190 second interval. Measurement chain circuits include provision for both geometric and risetime anticoincidence. A detailed description of the instrument is included as is pertinent operating information.

Taylor, R. S.↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗

Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.↗

Detection of a very bright source close to the LMC supernova SN 1987A

High angular resolution observations of the supernova in the Large Magellanic Cloud, SN 1987A, have revealed a bright source separated from the SN by approximately 60 mas with a magnitude difference of 2.7 at 656 nm (H-alpha). Speckle imaging techniques were applied to data recorded with the CfA two-dimensional photon counting detector on the CTIO 4 m telescope on March 25 and April 2 to allow measurements in H-alpha on both nights and at 533 nm and 450 nm on the second night. The nature of this object is as yet unknown, though it is almost certainly a phenomenon related to the SN.

Nisenson, P.↗

Fatigue life estimates for helicopter loading spectra

Helicopter loading histories applied to notch metal samples are used as examples, and their fatigue lives are calculated by using a simplified version of the local strain approach. This simplified method has the advantage that it requires knowing the loading history in only the reduced form of ranges and means and number of cycles from the rain-flow cycle counting method. The calculated lives compare favorably with test data.

Khosrovaneh, A. K.↗

Fatigue life estimates for helicopter loading spectra

Helicopter loading histories applied to notch metal samples are used as examples, and their fatigue lives are calculated by using a simplified version of the local strain approach. This simplified method has the advantage that it requires knowing the loading history in only the reduced form of ranges and means and number of cycles from the rain-flow cycle counting method. The calculated lives compare favorably with test data.

Khosrovaneh, A. K.↗

Flexible Method for Inter-object Communication in C++

A method has been developed for organizing and sharing large amounts of information between objects in C++ code. This method uses a set of object classes to define variables and group them into tables. The variable tables presented here provide a convenient way of defining and cataloging data, as well as a user-friendly input/output system, a standardized set of access functions, mechanisms for ensuring data integrity, methods for interprocessor data transfer, and an interpretive language for programming relationships between parameters. The object-oriented nature of these variable tables enables the use of multiple data types, each with unique attributes and behavior. Because each variable provides its own access methods, redundant table lookup functions can be bypassed, thus decreasing access times while maintaining data integrity. In addition, a method for automatic reference counting was developed to manage memory safely.

Curlett, Brian P.↗

Microcracking in composite laminates under thermal and mechanical loading

Composites used in space structures are exposed to both extremes in temperature and applied mechanical loads. Cracks in the matrix form, changing the laminate thermoelastic properties. The goal of the present investigation is to develop a predictive methodology to quantify microcracking in general composite laminates under both thermal and mechanical loading. This objective is successfully met through a combination of analytical modeling and experimental investigation. In the analysis, the stress and displacement distributions in the vicinity of a crack are determined using a shear lag model. These are incorporated into an energy based cracking criterion to determine the favorability of crack formation. A progressive damage algorithm allows the inclusion of material softening effects and temperature-dependent material properties. The analysis is implemented by a computer code which gives predicted crack density and degraded laminate properties as functions of any thermomechanical load history. Extensive experimentation provides verification of the analysis. AS4/3501-6 graphite/epoxy laminates are manufactured with three different layups to investigate ply thickness and orientation effects. Thermal specimens are cooled to progressively lower temperatures down to -184 C. After conditioning the specimens to each temperature, cracks are counted on their edges using optical microscopy and in their interiors by sanding to incremental depths. Tensile coupons are loaded monotonically to progressively higher loads until failure. Cracks are counted on the coupon edges after each loading. A data fit to all available results provides input parameters for the analysis and shows them to be material properties, independent of geometry and loading. Correlation between experiment and analysis is generally very good under both thermal and mechanical loading, showing the methodology to be a powerful, unified tool. Delayed crack initiation observed in a few cases is attributed to a lack of preexisting flaws assumed by the analysis. Some interactions between adjacent ply groups are attributed to local stress concentrations. These two effects are not captured by the analysis due to its global nature. The analysis is conservative in these cases and agrees well with data after the observed onset of cracking.

Maddocks, Jason R.↗

Survivability of Microbes in Mars Wind Blown Dust Environment

Although the probability of Earth microbes growing (dividing) in the Martian environment is extremely low, the probability of their survival on the Martian surface is unknown. During the course of landed missions to Mars terrestrial microbes may reach the surface of Mars via inadequately sterilized spacecraft landers, rovers, or through accidental impact of orbiters. This investigation studied the potential for Earth microbes to survive in the windblown dust on the surface of Mars. The rationale for the study comes from the fact that Mars regularly has huge dust storms that engulf the planet, shading the surface from solar UV radiation. These storms serve as a mechanism for global transfer of dust particles. If live organisms were to be transported to the surface of Mars they could be picked up with the dust during a dust storm and transported across the planet. Washed, dried spores of Bacillus subtilis strain HA 101 were aseptically mixed with sterile sieved (size range of 1-5microns) Mars soil standard (obtained from NASA Johnson Space Center, Houston, Texas, USA), or Fe-montmorillonite such that the number of microbes equals 5 x 10(exp 6)/g dry wt soil. The microbe soil mixture was placed in a spherical 8 L Mars simulation chamber equipped with a variable speed rotor, gas ports and an Oriel deuterium UV lamp emitting light of wave lengths 180-400 nm. The chamber was sealed, flushed with a simulated Martian atmosphere (96.9% CO2, 3% O2, 0.1% H2O), and the pressure brought to 10 torr. The lamp and rotor were switched on to begin the experiment. Periodically samples were collected from the chamber, and the numbers of microbial survivors g soil was determined using plate counts and the most probable number method (MPN). The data indicate that Bacillus subtilis spores dispersed with Mars analog soil in a Mars atmosphere (wind blown dust) survive exposure to 5.13 KJ m-2 UV radiation, suggesting that Mars wind blown dust has potential to the protect microbes from solar UV radiation.

Mancinelli, Rocco L.↗

NASA Tech Briefs, October 2007

Topics covered include; Wirelessly Interrogated Position or Displacement Sensors; Ka-Band Radar Terminal Descent Sensor; Metal/Metal Oxide Differential Electrode pH Sensors; Improved Sensing Coils for SQUIDs; Inductive Linear-Position Sensor/Limit-Sensor Units; Hilbert-Curve Fractal Antenna With Radiation- Pattern Diversity; Single-Camera Panoramic-Imaging Systems; Interface Electronic Circuitry for an Electronic Tongue; Inexpensive Clock for Displaying Planetary or Sidereal Time; Efficient Switching Arrangement for (N + 1)/N Redundancy; Lightweight Reflectarray Antenna for 7.115 and 32 GHz; Opto-Electronic Oscillator Using Suppressed Phase Modulation; Alternative Controller for a Fiber-Optic Switch; Strong, Lightweight, Porous Materials; Nanowicks; Lightweight Thermal Protection System for Atmospheric Entry; Rapid and Quiet Drill; Hydrogen Peroxide Concentrator; MMIC Amplifiers for 90 to 130 GHz; Robot Would Climb Steep Terrain; Measuring Dynamic Transfer Functions of Cavitating Pumps; Advanced Resistive Exercise Device; Rapid Engineering of Three-Dimensional, Multicellular Tissues With Polymeric Scaffolds; Resonant Tunneling Spin Pump; Enhancing Spin Filters by Use of Bulk Inversion Asymmetry; Optical Magnetometer Incorporating Photonic Crystals; WGM-Resonator/Tapered-Waveguide White-Light Sensor Optics; Raman-Suppressing Coupling for Optical Parametric Oscillator; CO2-Reduction Primary Cell for Use on Venus; Cold Atom Source Containing Multiple Magneto- Optical Traps; POD Model Reconstruction for Gray-Box Fault Detection; System for Estimating Horizontal Velocity During Descent; Software Framework for Peer Data-Management Services; Autogen Version 2.0; Tracking-Data-Conversion Tool; NASA Enterprise Visual Analysis; Advanced Reference Counting Pointers for Better Performance; C Namelist Facility; and Efficient Mosaicking of Spitzer Space Telescope Images.

Source record↗

Update on Heavy-Meson Spectrum Tests of the Oktay--Kronfeld Action

We present updated results of a numerical improvement test with heavy-meson spectrum for the Oktay--Kronfeld (OK) action. The OK action is an extension of the Fermilab improvement program for massive Wilson fermions including all dimension-six and some dimension-seven bilinear terms. Improvement terms are truncated by HQET power counting at $\mathrm{O}(\Lambda^3/m_Q^3)$ for heavy-light systems, and by NRQCD power counting at $\mathrm{O}(v^6)$ for quarkonium. They suffice for tree-level matching to QCD to the given order in the power-counting schemes. To assess the improvement, we generate new data with the OK and Fermilab action that covers both charm and bottom quark mass regions on a MILC coarse $(a \approx 0.12~\text{fm})$ $2+1$ flavor, asqtad-staggered ensemble. We update the analyses of the inconsistency quantity and the hyperfine splittings for the rest and kinetic masses. With one exception, the results clearly show that the OK action significantly reduces heavy-quark discretization effects in the meson spectrum. The exception is the hyperfine splitting of the heavy-light system near the $B_s$ meson mass, where statistics are too low to draw a firm conclusion, despite promising results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects of the ICESat-2 Laser Altimetry Mission for Savanna Ecosystem Structural Studies Based on Airborne Simulation Data

The next planned spaceborne lidar mission is the Ice, Cloud and land Elevation Satellite 2 (ICESat-2), which will use the Advanced Topographic Laser Altimeter System (ATLAS) sensor, a photon counting technique. To pre-validate the capability of this mission for studying three dimensional vegetation structure in savannas, we assessed the potential of the measurement approach to estimate canopy height in an oak savanna landscape. We used data from the Multiple Altimeter Beam Experimental Lidar (MABEL), an airborne photon counting lidar sensor developed by NASA's Goddard Space Flight Center. ATLAS-like data was generated using the MATLAS simulator, which adjusts MABEL data's detected number of signal and noise photons to that expected from the ATLAS instrument. Transects flown over the Tejon ranch conservancy in Kern County, California, USA were used for this work. For each transect we chose to use data from the near infrared channel that had the highest number of photons. We segmented each transect into 50 m, 25 m and 14 m long blocks and aggregated the photons in each block into a histogram based on their elevation values. We then used an automated algorithm to identify cut off points where the cumulative density of photons from the highest elevation indicates the presence of the canopy top and likewise where such cumulative density from the lowest elevation indicates the mean terrain elevation. MABEL derived height metrics were moderately correlated to discrete return lidar (DRL) derived height metrics r(sub 2) and RMSE values ranging from 0.60 to 0.73 and 2.9 m to 4.4 m respectively) but MATLAS simulation resulted in more modest correlations with DRL indices r(sub 2) ranging from 0.5 to 0.64 and RMSE from 3.6 m to 4.6 m). Simulations also indicated that the expected number of signal photons from ATLAS will be substantially lower, a situation that reduces canopy height estimation precision especially in areas of low density vegetation cover. On the basis of the simulated data, there is reason to believe that the ability of ICESat-2 to estimate height in savannas will be comparable to the original ICESat mission although the respective sensors have different measurement principles.

Gwenzi, David↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVALUATION OF AN UPWARD TREND IN BACKGROUND COUNT RATES FROM A STACK PARTICULATE CONTINUOUS AIR MONITOR

The Pacific Northwest National Laboratory (PNNL) operates the Radiochemical Processing Laboratory (RPL), which is a multi-purpose, non-reactor nuclear research facility. Regulations require both continuous sampling and monitoring of radioactive particulates and tritium gas in the exhaust from the main stack. Releases of other radioactive gases, including planned releases of radon, are tracked separately in a database and reported. During the 2015 calibration of the RPL stack continuous air monitor (CAM), measured alpha and beta background count rates were much higher than expected, especially when compared to count rates from previous calibrations. The source of the higher background count rates was examined by trending of historical CAM measurements and a comparison to the sampler data. The analysis revealed that the sample results showed no increase in emissions, whereas the CAM showed a steady increase in count rates. Ultimately, the CAM filter was analyzed and found to contain higher-than-normal background levels of 220Rn progeny. Assessments were performed to determine the cause of the increased background values, including reviews of building research activities, radioactive material usage and storage, adequacy of procedures, and the potential for internal CAM contamination. Project reviews determined that a research activity involving 228Th was left in a semi-stored state, resulting in 220Rn being released from a hot cell into the exhaust system. The 228Th source material was subsequently repackaged and contained resulting in a decrease of CAM background count rates. An estimate of the 220Rn release was made and the contribution to the annual offsite dose from the facility was calculated. The released activity and reported dose results were well below the permit limits for the facility.

radon, 220Rn, environmental assessment, air monito↗

Small-scale fluctuations of the X-ray background

Fluctuations of the diffuse X-ray background are investigated using the Einstein Observatory Deep Survey data. Small angular-scale variations of the numbers of counts in the energy range 0.8-3.5 keV in the central 32 x 32 sq arcmin of the IPC are analyzed by means of the two-point correlation function. It is shown that detector modulation contributes substantially to the observed fluctuations. Instrumental effects are estimated and subtracted from the raw observations. The residual fluctuations are used to estimate the log N-log S relation of the X-ray sources below the Einstein sensitivity limit. Taking into account numerous uncertainties involved in this analysis, it is shown that the amplitude of fluctuations observed in the Deep Survey data is consistent with a relatively small number of sources producing the X-ray background.

Soltan, A. M.↗

Automating cell detection and classification in human brain fluorescent microscopy images using dictionary learning and sparse coding

Background Immunofluorescence (IF) plays a major role in quantifying protein expression in situ and understanding cell function. It is widely applied in assessing disease mechanisms and in drug discovery research. Automation of IF analysis can transform studies using experimental cell models. However, IF analysis of postmortem human tissue relies mostly on manual interaction, often subjected to low-throughput and prone to error, leading to low inter and intra-observer reproducibility. Human postmortem brain samples challenges neuroscientists because of the high level of autofluorescence caused by accumulation of lipofuscin pigment during aging, hindering systematic analyses. We propose a method for automating cell counting and classification in IF microscopy of human postmortem brains. Our algorithm speeds up the quantification task while improving reproducibility. New method Dictionary learning and sparse coding allow for constructing improved cell representations using IF images. These models are input for detection and segmentation methods. Classification occurs by means of color distances between cells and a learned set. Results Our method successfully detected and classified cells in 49 human brain images. We evaluated our results regarding true positive, false positive, false negative, precision, recall, false positive rate and F1 score metrics. We also measured user-experience and time saved compared to manual countings. Comparison with existing methods We compared our results to four open-access IF-based cell-counting tools available in the literature. Lastly, our method showed improved accuracy for all data samples. Conclusion The proposed method satisfactorily detects and classifies cells from human postmortem brain IF images, with potential to be generalized for applications in other counting tasks.

59 BASIC BIOLOGICAL SCIENCES↗