Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Increasing Efficiency at the NTF by Optimizing Model AoA Positioning

The National Transonic Facility (NTF) at NASA Langley Research Center (LaRC) is a national resource for aeronautical research and development. The government, military and private industries rely on the capability of this facility for realistic flight data. Reducing the operation costs and keeping the NTF affordable is essential for aeronautics research. The NTF is undertaking an effort to reduce the time between data points during a pitch polar. This reduction is being driven by the operating costs of a cryogenic facility. If the time per data point can be reduced, a substantial cost savings can be realized from a reduction in liquid nitrogen (LN2) consumption. It is known that angle-of-attack (AoA) positioning is the longest lead-time item between points. In January 2005 a test was conducted at the NTF to determine the cause of the long lead-time so that an effort could be made to improve efficiency. The AoA signal at the NTF originates from onboard instrumentation then travels through a number of different systems including the signal conditioner, digital voltmeter, and the data system where the AoA angle is calculated. It is then fed into a closed loop control system that sets the model position. Each process along this path adds to the time per data point affecting the efficiency of the data taking process. Due to the nature of the closed loop feed back AoA control and the signal path, it takes approximately 18 seconds to take one pitch pause point with a typical AoA increment. Options are being investigated to reduce the time delay between points by modifying the signal path. These options include: reduced signal filtering, using analog channels instead of a digital volt meter (DVM), re-routing the signal directly to the AoA control computer and implementing new control algorithms. Each of these has potential to reduce the positioning time and together the savings could be significant. These timesaving efforts are essential but must be weighed against possible loss of data quality. For example, a reduction in filtering can introduce noise into the signal and using analog channels could result in some loss of accuracy. Data quality assessments need to be performed concurrently with timesaving techniques since data quality parameters are essential in maintaining facility integrity. This paper will highlight time saving efforts being undertaken or studied at the NTF. It will outline the instrumentation and computer systems involved in setting of the model pitch attitude then suggest changes to the process and discuss how these system changes would effect the time between data points. It also discusses the issue of data quality and how the potential efficiency changes in the system could affect it. Lastly, it will discuss the possibility of using an open loop control system and give some pros and cons of this method.

Crawford, Bradley L.↗

Building Analytics Tool Deployment at Scale: Benefits, Costs, and Deployment Practices

Buildings are becoming more data-rich. Building analytics tools, including energy information systems (EIS) and fault detection and diagnostic (FDD) tools, have emerged to enable building operators to translate large amounts of time-series data into actionable findings to achieve energy and non-energy benefits. To expedite data analytics adoption and facilitate technology innovation, building owners, technology developers, and researchers need reliable cost–benefit data and evidence-based guidance on deployment practices. This paper fulfills these needs with the energy use and survey data from a wide-ranging research and industry partnership program that covers thousands of buildings installed with analytics tools. The paper indicates that after two years of implementation, organizations using FDD tools and EIS tools achieved 9% and 3% median annual energy savings, respectively. The median base cost and annual recurring cost for FDD are USD 0.65 per square meter (m2) (USD 0.06 per square foot [ft2]) and USD 0.22 per m2 (USD 0.02 per ft2), and are USD 0.11 per m2 (USD 0.01 per ft2) and USD 0.11 per m2 (USD 0.01 per ft2) for EIS. The common metrics and analyses that are used in the tools to support the discovery of energy efficiency measures are summarized in detail. Two best practice examples identified to maximize the benefits of tool implementation are also presented. Opportunities to advance the state of technology include simplified data integration and management, and more efficient processes for acting on analytics outputs. Compared with previous efforts in the literature, the findings presented in this paper demonstrate the effectiveness of building analytics tools with the largest known dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Reliability Analyses of AC and 380V DC Distribution in Data Centers

Modern data centers consume large amounts of electricity, resulting in high operational costs. The efficiency of a data center power distribution system can be increased, and the operational cost reduced, if the number of power conversion stages can be minimized and more efficient converters, such as wide bandgap (WBG) converters, are used. This can be achieved by using DC distribution voltage at the rack level by eliminating extra conversion stages. In this paper, benchmarks for both AC and 380V DC data centers were developed and efficiency analyses were performed for an entire year. The impact of integrating photovoltaic (PV) systems into the data centers has also been analyzed in both cases in terms of efficiency. The results show that 380V DC data centers are more efficient than AC data centers with and without PV integration. Furthermore, the reliability of an AC system was compared to a 380V DC architecture with Tier-IV standard. Monte-Carlo simulations were used to perform reliability analyses for different levels of redundancy in the Uninterruptible Power Supply (UPS) system for both cases. In conclusion, the simulation results showed that the 380V DC distribution system had a higher level of reliability than the AC distribution system in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commentary: The Materials Project: A materials genome approach to accelerating materials innovation

Accelerating the discovery of advanced materials is essential for human welfare and sustainable, clean energy. In this paper, we introduce the Materials Project (www.materialsproject.org), a core program of the Materials Genome Initiative that uses high-throughput computing to uncover the properties of all known inorganic materials. This open dataset can be accessed through multiple channels for both interactive exploration and data mining. The Materials Project also seeks to create open-source platforms for developing robust, sophisticated materials analyses. Future efforts will enable users to perform ''rapid-prototyping'' of new materials in silico , and provide researchers with new avenues for cost-effective, data-driven materials design.

36 MATERIALS SCIENCE↗

A unique modulation system for two channel data transmission

A simple low cost system is reported for the telemetry of information from meteorological rocket payloads including parachute borne systems. It uses S- or L-band microwave links with low cost oscillator type transmitters. An extension of this system to transmit two channels of data simultaneously by standard time and frequency multiplexing techniques as a sampled pulse is described. One channel is represented by the pulse repetition rate while the other channel is represented by the instantaneous duty cycle of the pulse train.

Melrose, B. T.↗

AEOSS design guide for system analysis on Advanced Earth-Orbital Spacecraft Systems

Advanced Earth Orbital Spacecraft System (AEOSS) enables users to project the requried power, weight, and cost for a generic earth-orbital spacecraft system. These variables are calculated on the component and subsystem levels, and then the system level. The included six subsystems are electric power, thermal control, structure, auxillary propulsion, attitude control, and communication, command, and data handling. The costs are computed using statistically determined models that were derived from the flown spacecraft in the past and were categorized into classes according to their functions and structural complexity. Selected design and performance analyses for essential components and subsystems are also provided. AEOSS has the feature permitting a user to enter known values of these parameters, totally and partially, at all levels. All information is of vital importance to project managers of subsystems or a spacecraft system. AEOSS is a specially tailored software coded from the relational database program of the Acius; 4th Dimension with a Macintosh version. Because of the licensing agreement, two versions of the AEOSS documents were prepared. This version AEOSS Design Guide, is for users to exploit the full capacity of the 4th Dimension. It is for a user who wants to alter or expand the program structures, the program statements, and the program procedures. The user has to possess a 4th Dimension first.

Lee, Hwa-Ping↗

AEOSS runtime manual for system analysis on Advanced Earth-Orbital Spacecraft Systems

Advanced earth orbital spacecraft system (AEOSS) enables users to project the required power, weight, and cost for a generic earth-orbital spacecraft system. These variables are calculated on the component and subsystem levels, and then the system level. The included six subsystems are electric power, thermal control, structure, auxiliary propulsion, attitude control, and communication, command, and data handling. The costs are computed using statistically determined models that were derived from the flown spacecraft in the past and were categorized into classes according to their functions and structural complexity. Selected design and performance analyses for essential components and subsystems are also provided. AEOSS has the feature permitting a user to enter known values of these parameters, totally and partially, at all levels. All information is of vital importance to project managers of subsystems or a spacecraft system. AEOSS is a specially tailored software coded from the relational database program of the Acius' 4th Dimension with a Macintosh version. Because of the licensing agreements, two versions of the AEOSS documents were prepared. This version, AEOSS Runtime Manual, is permitted to be distributed with a finite number of the restrictive 4D Runtime version. It can perform all contained applications without any programming alterations.

Lee, Hwa-Ping↗

Central Processor Acts as High-Speed DMA Controller

Computer-system architecture enables system host central processor (CP) to make high-speed, direct-memory-access (DMA) data transfers without cost and complexity of adding dedicated DMA controller. New system, CCP used as DMA controller, obviating need for dedicated DMA controller; yet maximum transfer rates equivalent to those obtained with dedicated DMA controller. Useful wherever dedicated DMA controller desired because of required data-transfer rates.

Blaha, Matthew S.↗

Next Generation Environmentally-Friendly Driving Feedback Systems Research and Development

The objective of this project is to design, develop, and demonstrate a next-generation, federal safety- and emission-complaint driving feedback system that can be deployed across the existing vehicle fleet and improve fleet average fuel efficiency by at least 2%. The project objective was achieved with the driving feedback system that encourages fuel-efficient vehicle travel and operation through: 1) Eco-Routing Navigation module that suggests the most fuel-efficient route from one stop to the next, 2) Eco-Driving Feedback module that provides sensible information, recommendation, and warning regarding fuel-efficient vehicle operation, and 3) Eco-Score and Eco-Rank module that provides a means for driving performance tracking, self-evaluation, and peer comparison. The system also collects and stores vehicle travel and operation data, which are used by Algorithm Updating module to customize the other modules for specific vehicles and adapts them to specific drivers over time. The driving feedback system was designed and developed as an aftermarket technology that can be retrofitted to vehicles in the existing fleet. It consists of a mobile application for smart devices running Android operating system, a vehicle on-board diagnostics connector, and a data server. While the system receives and utilizes real-time vehicle and engine data from the vehicle’s controller area network bus through the vehicle’s on-board diagnostic connector, it does not modify or interfere with the vehicle’s controller area network bus, and thus, is in compliance with federal safety and emission regulations. The driving feedback system was demonstrated and then installed on 45 vehicles from three different fleets for field operational test. These include 15 private vehicles of the general public, 15 pickup trucks of the California Department of Transportation that are assigned to individual employees for business use, and 15 shuttle buses of the Riverside Transit Agency that are used for paratransit service. Detailed vehicle travel and operation data including route taken, driving speed, acceleration, braking, and the corresponding fuel consumption, were collected both before and during the test period. The data analysis results show that the fleet average fuel efficiency improvements for the three fleets with the use of the driving feedback system are in the range of 2% to 9%. The economic viability of the driving feedback system is high. A fully deployed system would require capital investment in smart device ($150-$350) and on-board diagnostics connector ($50-$100) as well as paying operating costs for wireless data plan and subscription fees ($20-$30 per month) for connecting to the data server and receiving various system services. For individual consumers who already own a smart device (such as smartphone) and commercial fleets that already use some kind of telematics services, the costs for deploying this driving feedback system would be much lower.

33 ADVANCED PROPULSION SYSTEMS↗

Integration of sensing and computing in an intelligent decision support system for homeland security defense

We propose an intelligent decision support system based on sensor and computer networks that incorporates various component techniques for sensor deployment, data routing, distributed computing, and information fusion. The integrated system is deployed in a distributed environment composed of both wireless sensor networks for data collection and wired computer networks for data processing in support of homeland security defense. We present the system framework and formulate the analytical problems and develop approximate or exact solutions for the subtasks: (i) sensor deployment strategy based on a two-dimensional genetic algorithm to achieve maximum coverage with cost constraints; (ii) data routing scheme to achieve maximum signal strength with minimum path loss, high energy efficiency, and effective fault tolerance; (iii) network mapping method to assign computing modules to network nodes for high-performance distributed data processing; and (iv) binary decision fusion rule that derive threshold bounds to improve system hit rate and false alarm rate. These component solutions are implemented and evaluated through either experiments or simulations in various application scenarios. The extensive results demonstrate that these component solutions imbue the integrated system with the desirable and useful quality of intelligence in decision making.

59 BASIC BIOLOGICAL SCIENCES↗

Decision support for United States—Canada energy integration is impaired by fragmentary environmental and electricity system modeling capacity

The renewable energy transition is leading to increased electricity trade between the United States and Canada, with Canadian hydropower providing firm lower-carbon power and buffering variability of wind and solar generation in the U.S. However, long-term power purchase agreements and transborder transmission projects are controversial, with two of four proposed transmission lines between Quebec, Canada and the northeast U.S. cancelled since 2018. Here, we argue that controversies are exacerbated by a lack of open-source data and tools to understand tradeoffs of new hydropower generation and transmission infrastructure in comparison to alternatives. This gap includes impacts that incremental transmission and generation projects have on the economics of the entire system, for example, how new transmission projects affect exports to existing markets or incentivize new generation. We identify priority areas for data synthesis and model development, such as integrating linked hydropower and hydrologic interactions in energy system models and openly releasing (by utilities) or back-calculating (by researchers) hydropower generation and operational parameters. Publicly available environmental (e.g. streamflow, precipitation) and techno-economic (e.g. costs, reservoir size,) data can be used to parameterize freely usable and extensible models. Existing models have been calibrated with operational data from Canadian utilities that are not publicly available, limiting the range of scientific and commercial questions these tools have been used to answer and the range of parties that have been involved. Studies conducted using highly resolved, national-scale public data exist in other countries, notably, the United States, and demonstrate how greater transparency and extensibility can drive industry action. Improved data availability in Canada could facilitate approaches that (1) increase participation in decarbonization planning by a broader range of actors; (2) allow independent characterizations of environmental, health, and economic outcomes of interest to the public; and (3) identify decarbonization pathways consistent with community values.

13 HYDRO ENERGY↗

Novel Flow Sheet for Low Energy CO 2 Capture Enabled by Biocatalyst Delivery System

This report documents a preliminary Techno-Economic Assessment (TEA) for processes utilizing Akermin’s second generation biocatalyst delivery system to enhance AKM24, a non- volatile salt solution for CO 2 capture. Biocatalyst enhanced AKM24 offers the potential to reduce the cost of CO 2 capture in flue gas applications due to its improved equilibrium and stoichiometric properties that result in double the absorption capacity relative to previously demonstrated biocatalyst enhanced solvents. The study assumes a new supercritical pulverized coal fired power plant with a net output of 550 MWe after 90% CO 2 capture and uses the June 2011 cost basis (August 2012 update of Bituminous Baseline Study, or BBS). Power plant modeling, capital cost review, and economic calculations were provided by WorleyParsons. Rate-based CO2 capture process modeling and equipment sizing was performed by Akermin using AspenPlus® V8.4, customized to accurately predict thermodynamics, kinetics, and physical properties of the AKM-24 solvent based on available laboratory data. Equipment capital costs were estimated using Aspen Process Economic Analyzer™ which compared well with published baseline cost estimates. Quotes of equipment costs and power consumption for vacuum blower and CO 2 compression equipment were also provided by Man Diesel & Turbo. Three process scenarios were examined for Akermin biocatalyst enhanced solvent systems including: Case-1A: an absorption-desorption system operated with a reboiler pressure of 0.16 bara (60°C); Case-2A: an absorption-desorption system with moderate vacuum assisted regeneration at 0.40 bara (80°C); and finally, Case-2B: a conventional absorption-desorption system with near atmospheric pressure regeneration at 1.07 bara (105°C). The estimated increases in cost of electricity (ICOE) for these cases were $58.1/MWh, $47.3/MWh and $46.4/MWh, respectively. Case 2B had the best results for this analysis achieving an estimated 30% reduction in ICOE relative to the NETL Case 12 (v2) baseline of $66.3/MWh ICOE. Likewise, Case-2B achieved capture costs of $53.0/tCO2 and 65.7/tCO 2 avoided, which equates to 20.2% and 31.4% savings relative to the Case 12 baseline ($66.4/tCO 2 and $95.9/tCO 2 avoided). While Case 2A and 2B have similar results, Case 2A requires further development. Focus on Case 2B is recommended for this project because its cost performance is closest to the DOE goals, and has it has the best potential to achieve a successful demonstration at the next scale.

Reardon, John↗

Unsupervised classification for region of interest in X-ray ptychography

X-ray ptychography offers high-resolution imaging of large areas at a high computational cost due to the large volume of data provided. To address the cost issue, we propose a physics-informed unsupervised classification algorithm that is performed prior to reconstruction and removes data outside the region of interest (RoI) based on the multimodal features present in the diffraction patterns. The preprocessing time for the proposed method is inconsequential in contrast to the resource-intensive reconstruction process, leading to an impressive reduction in the data workload to a mere 20% of the initial dataset. This capability consequently reduces computational time dramatically while preserving reconstruction quality. Through further segmentation of the diffraction patterns, our proposed approach can also detect features that are smaller than beam size and correctly classify them as within the RoI.

97 MATHEMATICS AND COMPUTING↗

FORCE Development Status Update: Vertical Integration and Benchmarking of System Dynamics

Recent efforts to establish effective models for grid energy analysis, especially given the increase in variable renewable energy (VRE) sources and the economic challenges faced by traditional nuclear energy, have generated new technological considerations. One effort to improve the economic viability of nuclear power involves investigating integrated energy systems (IES) which include secondary energy systems that introduce flexibility and secondary market possibilities to existing and perceived future nuclear energy generation technologies. To analyze the technical and economic potential of IES, the Framework for Optimization of Resources and Economics (FORCE) tool suite was developed through a collaboration among national laboratories. Within the FORCE tool suite, the Holistic Energy Resource Optimization Network (HERON) provides algorithms for analyzing the long-term viability of potential IES technologies, while HYBRID provides algorithms and models to achieve high-resolution analysis of coupling physics over a short time period. Continued maturing of the FORCE tool suite requires further interconnections between the various tools in the suite in order to ensure consistent analysis. Analyses performed by applying HYBRID to transient process modeling should be easily harvestable as inputs to HERON analyses. The first item in this status update is a demonstration of an automated data pipeline for loading data from HYBRID into HERON analyses. Application of HYBRID results to HERON, as part of using the FORCE tool suite, relies on robust modeling assumptions for the various models included in HYBRID. The second result of this status update is the benchmarking and validation of cost and operational data, with a particular focus on natural gas energy generators. These generators are benchmarked with a focus on contrasting them with proposed thermal energy storage (TES) technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

IEA Wind Task 26 - Multi-national Case Study of the Financial Cost of Wind Energy: Work Package 1 Final Report

The lifetime cost of wind energy is comprised of a number of components including the investment cost, operation and maintenance costs, financing costs, and annual energy production. Accurate representation of these cost streams is critical in estimating a wind plant's cost of energy. Some of these cost streams will vary over the life of a given project. From the outset of project development,investors in wind energy have relatively certain knowledge of the plant's lifetime cost of wind energy. This is because a wind energy project's installed costs and mean wind speed are known early on, and wind generation generally has low variable operation and maintenance costs, zero fuel cost, and no carbon emissions cost. Despite these inherent characteristics, there are wide variations in thecost of wind energy internationally, which is the focus of this report. Using a multinational case-study approach, this work seeks to understand the sources of wind energy cost differences among seven countries under International Energy Agency (IEA) Wind Task 26 - Cost of Wind Energy. The participating countries in this study include Denmark, Germany, the Netherlands, Spain, Sweden,Switzerland, and the United States. Due to data availability, onshore wind energy is the primary focus of this study, though a small sample of reported offshore cost data is also included.

17 WIND ENERGY↗

Bio-Restore Workshop Summary Report

This report summarizes the results of a Bioenergy Technologies Office-sponsored public workshop held at Argonne National Laboratory on September 25–26, 2019. The purpose of the Bio-Restore Workshop was to bring together experts to discuss the current state of the technology and to identify data and R&D relevant to the bio-restore concept. Specific topics included using dedicated energy crops and other biomass sources to provide environmental benefits, implementing algae technologies (e.g., wastewater treatment, direct bloom harvest, turf scrubbers, macroalgae), quantifying and valorizing ecosystem services, developing low-cost sensors and data management systems, and integrating “bio-restore biomass” with supply chain needs. For the purposes of the workshop, the term “bio-restore biomass” refers to terrestrial and algal biomass that provides environmental benefits when produced or harvested. For terrestrial biomass, this primarily includes energy crops (herbaceous and woody), other cellulosic biomass, and waste biomass. For algal biomass, this includes wastewater treatment algal biomass, algal blooms, algal turf scrubbers/attached growth systems, and macroalgae. Types of biomass not of interest to the workshop discussions include oilseed crops, crops generally grown for food or feed, and algae grown in artificial light conditions or other energy-intensive cultivation designs.

09 BIOMASS FUELS↗

AUTOMATIC CLASSIFICATION OF VARIABLE STARS IN CATALOGS WITH MISSING DATA

We present an automatic classification method for astronomical catalogs with missing data. We use Bayesian networks and a probabilistic graphical model that allows us to perform inference to predict missing values given observed data and dependency relationships between variables. To learn a Bayesian network from incomplete data, we use an iterative algorithm that utilizes sampling methods and expectation maximization to estimate the distributions and probabilistic dependencies of variables from data with missing values. To test our model, we use three catalogs with missing data (SAGE, Two Micron All Sky Survey, and UBVI) and one complete catalog (MACHO). We examine how classification accuracy changes when information from missing data catalogs is included, how our method compares to traditional missing data approaches, and at what computational cost. Integrating these catalogs with missing data, we find that classification of variable objects improves by a few percent and by 15% for quasar detection while keeping the computational cost the same.

79 ASTRONOMY AND ASTROPHYSICS↗