Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Implementation of a three-qubit quantum error-correction code in a cavity-QED setup

The correction of errors is of fundamental importance for the development of contemporary computing devices and robust communication protocols. In this paper we propose a scheme for the implementation of the three-qubit quantum repetition code, exploiting the interaction of Rydberg atoms with the quantized mode of a microwave cavity field. Quantum information is encoded within two circular Rydberg states of the atoms and encoding and decoding processes are realized within two separate microwave cavities. We show that errors due to phase-noise fluctuations could be efficiently corrected using a state-of-the-art apparatus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Limitations of quantum computing with Gaussian cluster states

We discuss the potential and limitations of Gaussian cluster states for measurement-based quantum computing. Using a framework of Gaussian-projected entangled pair states, we show that no matter what Gaussian local measurements are performed on systems distributed on a general graph, transport and processing of quantum information are not possible beyond a certain influence region, except for exponentially suppressed corrections. We also demonstrate that even under arbitrary non-Gaussian local measurements, slabs of Gaussian cluster states of a finite width cannot carry logical quantum information, even if sophisticated encodings of qubits in continuous-variable systems are allowed for. This is proven by suitably contracting tensor networks representing infinite-dimensional quantum systems. The result can be seen as sharpening the requirements for quantum error correction and fault tolerance for Gaussian cluster states and points toward the necessity of non-Gaussian resource states for measurement-based quantum computing. The results can equally be viewed as referring to Gaussian quantum repeater networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Convergent conductivity corrections to the Casimir force via exponential basis functions

A closed-form finite conductivity correction factor for the ideal Casimir force is proposed, based on exponential basis functions. Our method can facilitate experimental verifications of theories in the study of the Casimir force. A theoretical analysis is given to explain why our method is accurate at both large and small separation gaps. Numerical computations have been performed to confirm that our method is accurate in various experimental configurations. Our approach is widely applicable to various Casimir force interactions between metals and dielectrics. Our study can be extended to the study of the repulsive Casimir force as well.

36 MATERIALS SCIENCE↗

Experimental demonstration of nonlocal effects in the partial-collapse measurement and reversal process

We demonstrate experimentally the nonlocal reversal of a partial-collapse quantum measurement of a two-photon entangled state. Both the partial-collapse measurement and the reversal operation are implemented in linear optics with two displaced Sagnac interferometers, characterized by single-qubit quantum-process tomography. The recovered state is measured by quantum-state tomography, and its nonlocality is characterized by testing the Bell inequality. Our result will be helpful in quantum communication and quantum error correction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Blackbody-radiation correction to the polarizability of helium

The correction to the polarizability of helium due to blackbody radiation is calculated near room temperature. A precise theoretical determination of the blackbody radiation correction to the polarizability of helium is essential for dielectric gas thermometry and for the determination of the Boltzmann constant. We find that the correction, for not too high temperature, is roughly proportional to a modified hyperpolarizability (two-color hyperpolarizability), which is different from the ordinary hyperpolarizability of helium. Our explicit calculations provide a definite numerical result for the effect and indicate that the effect of blackbody radiation can be excluded as a limiting factor for dielectric gas thermometry using helium or argon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gerade-ungerade mixing in the hydrogen molecule

In homonuclear molecules, such as H{sub 2}, the rovibrational levels close to the dissociation threshold do not have definite symmetry with respect to the inversion of electronic variables. This effect--the gerade-ungerade mixing--results from interactions between magnetic moments of electrons and protons. We calculate this mixing on the level of adiabatic approximation and numerically solve the system of nuclear differential equations. It turns out that the corrections to the dissociation energy of rovibrational levels resulting from the mixing are negligible in comparison with the present accuracy of experiments. As a coproduct, an accurate clamped nuclei potential for the b {sup 3{Sigma}}{sub u}{sup +} state has been obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

Decoherence and dephasing errors caused by the dc Stark effect in rapid ion transport

We investigate the error due to the dc Stark effect for quantum information processing for trapped ion quantum computers using the scalable architecture proposed in D. Wineland et al. [J. Res. Natl. Inst. Stand. Technol. 103, 259 (1998)] and D. Kielpinski et al. [Nature (London) 417, 709 (2002)]. As the operational speed increases, dephasing and decoherence due to the dc Stark effect become prominent as a large electric field is applied for rapidly transporting ions. We estimate the relative significance of the decoherence and dephasing effects and find that the latter is dominant. We find that the minimum possible dephasing is quadratic in the length of a trap and an inverse cubic in the operational time scale. From these relations, we obtain the operational speed range at which the shifts, caused by the dc Stark effect, are no longer negligible, no matter on which trajectory the ion is transported. Without phase correction, the shortest time a qubit can be transferred across a 100-micrometer-long trap, without excessive error, is about 10 ns for a {sup 40}Ca{sup +} ion and 50 ps for a {sup 9}Be{sup +} ion. In practice, the accumulated error is difficult to track and to calculate; thus, our paper gives an estimate for the range of the speed limit imposed by the dc Stark effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dimuon radiation at relativistic energies available at the CERN Super Proton Synchrotron within a (3 + 1)D hydrodynamic + cascade model

We analyze dilepton emission from hot and dense matter using a hybrid approach based on the ultrarelativistic quantum molecular dynamics (UrQMD) transport model with an intermediate hydrodynamic stage for the description of heavy-ion collisions at relativistic energies. During the hydrodynamic stage, the production of lepton pairs is described by radiation rates for a strongly interacting medium in thermal equilibrium. In the low-mass region, hadronic thermal emission is evaluated by assuming vector meson dominance including in-medium modifications of the {rho} meson spectral function through scattering from nucleons and pions in the heat bath. In the intermediate-mass region, the hadronic rate is essentially determined by multipion annihilation processes. Emission from quark-antiquark annihilation in the quark gluon plasma (QGP) is taken into account as well. When the system is sufficiently dilute, the hydrodynamic description breaks down and a transition to a final cascade stage is performed. In this stage dimuon emission is evaluated as commonly done in transport models. By focusing on the enhancement with respect to the contribution from long-lived hadron decays after freezeout observed at the SPS in the low-mass region of the dilepton spectra, the relative importance of the different thermal contributions and of the two dynamical stages is investigated. We find that three separated regions can be identified in the invariant mass spectra. Whereas the very low and the intermediate-mass regions mostly receive contribution from the thermal dilepton emission, the region around the vector meson peak is dominated by the cascade emission. Above the {rho}-peak region the spectrum is driven by QGP radiation. Analysis of the dimuon transverse mass spectra reveals that the thermal hadronic emission shows an evident mass ordering not present in the emission from the QGP. A comparison of our calculation to recent acceptance-corrected NA60 data on invariant as well as transverse mass spectra is performed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated and differential fiducial cross-section measurements for the vector boson fusion production of the Higgs boson in the $H → WW^* → evμv$ decay channel at 13 TeV with the ATLAS detector

The vector-boson production cross-section for the Higgs boson decay in the H→WW*→eνμν channel is measured as a function of kinematic observables sensitive to the Higgs boson production and decay properties as well as integrated in a fiducial phase space. The analysis is performed using the proton-proton collision data collected by the ATLAS detector in Run 2 of the LHC at $\sqrt{s}$=13 TeV center-of-mass energy corresponding to an integrated luminosity of 139 fb -1 . The different flavor final state is studied by selecting an electron and a muon originating from a pair of W bosons and compatible with the Higgs boson decay. The data are corrected for the effects of detector inefficiency and resolution, and the measurements are compared with different state-of-the-art theoretical predictions. The differential cross-sections are used to constrain anomalous interactions described by dimension-six operators in an Effective Field Theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studying the underlying event in Drell-Yan and high transverse momentum jet production at the Tevatron

We study the underlying event in proton-antiproton collisions by examining the behavior of charged particles produced in association with a large transverse momentum jet ({approx}2.2 fb{sup -1}) or with a Drell-Yan lepton pair ({approx}2.7 fb{sup -1}) in the Z-boson mass region [70<M(pair)<110 GeV/c{sup 2}] as measured by CDF at 1.96 TeV center-of-mass energy. We use the direction of the lepton pair or the leading jet in each event to define regions of {eta}-{phi} space that are sensitive to the modeling of the underlying event. The data are corrected to the particle level to remove detector effects and are then compared with several QCD Monte Carlo models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Black and gray box learning of amplitude equations: Application to phase field systems

Here, we present a data-driven approach to learning surrogate models for amplitude equations and illustrate its application to interfacial dynamics of phase field systems. In particular, we demonstrate learning effective partial differential equations describing the evolution of phase field interfaces from full phase field data. We illustrate this on a model phase field system, where analytical approximate equations for the dynamics of the phase field interface (a higher-order eikonal equation and its approximation, the Kardar-Parisi-Zhang equation) are known. For this system, we discuss data-driven approaches for the identification of equations that accurately describe the front interface dynamics. When the analytical approximate models mentioned above become inaccurate, as we move beyond the region of validity of the underlying assumptions, the data-driven equations outperform them. In these regimes, going beyond black box identification, we explore different approaches to learning data-driven corrections to the analytically approximate models, leading to effective gray box partial differential equations.

42 ENGINEERING↗

Experimental Realization of Decoherence-Free Subspace in Neutron Interferometry

A decoherence-free subspace (DFS) is an important class of quantum-error-correcting (QEC) codes that have been proposed for fault-tolerant quantum computation. The applications of QEC techniques, however, are not limited to quantum-information processing (QIP). Here we demonstrate how QEC codes may be used to improve experimental designs of quantum devices to achieve noise suppression. In particular, neutron interferometry is used as a test bed to show the potential for adding quantum error correction to quantum measurements. We built a five-blade neutron interferometer that incorporates both a standard Mach-Zender configuration and a configuration based on a DFS. Experiments verify that the DFS interferometer is protected against low-frequency mechanical vibrations. We anticipate these improvements will increase the range of applications for matter-wave interferometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive two-pass cone-beam artifact correction using a FOV-preserving two-source geometry: A simulation study

The evolution to ever wider detector arrays that are able to cover whole organs with a single circular gantry sweep has revitalized the research efforts toward finding improved axial scanning algorithms and protocols. The authors propose a computed tomography scan and reconstruction concept using two sources, a single detector and a two-pass cone-beam correction method, as an integral part of the reconstruction. Compared with standard circular acquisition and reconstruction methods, the new concept excels with improved coverage and very low cone-beam artifact level also for short scan acquisitions, which makes it especially attractive for cardiac applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-175: Evaluation of the Relative Output Ratio for Collimator Jaw and MLC Defined Small Static 6MV Photon Fields

Purpose: To evaluate relative output ratio of collimator jaw and MLC defined small photon fields. Methods: Relative output ratios were measured using Gafchromic EBT3 film for a 6 MV photon beam on a Novalis Tx with HD120 MLC. Beam collimation was achieved by the jaws for 1.0 cm and 3.0 cm and MLC defined square field sizes between 0.5 cm and 1.0 cm with varying jaw settings between 2.0 and 4.0 cm. Film pieces were exposed to 4 Gy. Experiments were repeated with each session consisting of five consecutive exposures for the given MLC and/or jaw collimation and with the MLC and the jaws reset for each exposure. Films were scanned using EPSON 10000XL flatbed scanner approximately 24 hours after exposure in 48 bit RGB format at 150 dpi. Film calibration data were corrected for daily linac output variations. Doses were evaluated using the green channel with square ROI sizes of 0.1 – 0.6 cm. Converted doses were normalised for output ratio calculation using the 3.0 cm field as a machine specific reference field size. Mean output ratio and coefficient of variation (CV) were calculated for each experimental session. Results: For the Novalis 6 MV photon beam the output ratios between 0.719 and 0.872 have been measured for the jaw/MLC combinations tested. For a jaw setting of 4.0 cm field, the mean CV of the output ratios increased from 0.77% to 1.48% with decreasing MLC field size from 1.0 cm to 0.5 cm. For a nominal MLC 1.0 cm field, the CV increased to 1.00% from 0.77% with reducing jaw field size from 4.0 cm to 2.0 cm. Conclusion: The relative output ratio and the associated CV were dependent on the collimator jaw and MLC settings. The field size dependent CV showed similar trends to those reported in the literature.

60 APPLIED LIFE SCIENCES↗

SU-E-T-609: Evaluation of Transit Dosimetry Software Using Heterogeneous Phantom

Purpose: The purpose of this work was to evaluate limits and capabilities in the transit dosimetry software for use with the TomoTherapy system by irradiating a heterogeneous phantom. Methods: Helical TomoTherapy plan was created using CIRS phantom (model 062M) with nine various tissue equivalent inserts (lung inhale 0.2 g/cm{sup 3}, lung exhale 0.5 g/cm{sup 3}, adipose 0.96 g/cm{sup 3}, breast 0.99 g/cm{sup 3}, water 1.01 g/cm{sup 3}, muscle 1.06 g/cm{sup 3}, liver 1.07 g/cm{sup 3}, trabecular bone 1.16 g/cm{sup 3}, and dense bone 1.53 g/cm{sup 3}). Targets were contoured within every insert. The phantom was scanned with a 50 cm field of view and 3 mm slice width. Images were imported into the TomoTherapy TPS. A plan was generated to deliver 20 Gy to every insert (2 Gy per fraction) with a jaw width of 2.5 cm, a pitch of 0.430 and an actual modulation factor of 2.621. After the radiation delivery the planning CT, the RT structure, the RT plan, and the RT dose (DICOM format) as well as the exit detector sinogram were imported into the Dosimetry Check software (Math Resolutions, LLC). The 3D delivered doses were reconstructed from the exit detector data by correcting for phantom and couch attenuation. The resulting dose distribution were compared with the TPS planned dose using gamma index. Results: Using the clinical gamma criteria, 3% and 3 mm, all tissue equivalent inserts had a passing percentage of 100% except for 0.2 g/cm{sup 3} and 0.5 g/cm{sup 3} density inserts (gamma value of 81.67% and 99.18% respectively). Conclusion: The evaluated transit dosimetry software provides an independent verification of helical TomoTherapy plans giving additional confidence in the treatment delivery, however, an overestimation of the reconstructed dose in low density materials has been revealed. Implementation of Monte Carlo algorithm for exit dose reconstruction should improve dosimetric accuracy in heterogeneous patient tissues. Agreement with Math Resolutions.

60 APPLIED LIFE SCIENCES↗

A multifractal approach to space-filling recovery for PET quantification

Purpose: A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). Methods: A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV {sub mean}) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal and synthetic objects contaminated by partial volume effects (PVEs), validated on realistic {sup 18}F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical {sup 18}F-fluorothymidine PET test–retest dataset. Results: TLA estimates were stable for a range of resolutions typical in PET oncology (4–6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV {sub mean} or TV measurements across imaging protocols. Conclusions: The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.

60 APPLIED LIFE SCIENCES↗

SU-E-I-79: Source Geometry Dependence of Gamma Well-Counter Measurements

Purpose: To determine the effect of liquid sample volume and geometry on counting efficiency in a gamma well-counter, and to assess the relative contributions of sample geometry and self-attenuation. Gamma wellcounters are standard equipment in clinical and preclinical studies, for measuring patient blood radioactivity and quantifying animal tissue uptake for tracer development and other purposes. Accurate measurements are crucial. Methods: Count rates were measured for aqueous solutions of 99m- Tc at four liquid volume values in a 1-cm-diam tube and at six volume values in a 2.2-cm-diam vial. Total activity was constant for all volumes, and data were corrected for decay. Count rates from a point source in air, supported by a filter paper, were measured at seven heights between 1.3 and 5.7 cm from the bottom of a tube. Results: Sample volume effects were larger for the tube than for the vial. For the tube, count efficiency relative to a 1-cc volume ranged from 1.05 at 0.05 cc to 0.84 at 3 cc. For the vial, relative count efficiency ranged from 1.02 at 0.05 cc to 0.87 at 15 cc. For the point source, count efficiency relative to 1.3 cm from the tube bottom ranged from 0.98 at 1.8 cm to 0.34 at 5.7 cm. The relative efficiency of a 3-cc liquid sample in a tube compared to a 1-cc sample is 0.84; the average relative efficiency for the solid sample in air between heights in the tube corresponding to the surfaces of those volumes (1.3 and 4.8 cm) is 0.81, implying that the major contribution to efficiency loss is geometry, rather than attenuation. Conclusion: Volume-dependent correction factors should be used for accurate quantitation radioactive of liquid samples. Solid samples should be positioned at the bottom of the tube for maximum count efficiency.

60 APPLIED LIFE SCIENCES↗