Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Introduction to the Special Session on Thermal Remote Sensing Data for Earth Science Research: The Critical Need for Continued Data Collection and Development of Future Thermal Satellite Sensors

There is a rich and long history of thermal infrared (TIR) remote sensing data for multidisciplinary Earth science research. The continuity of TIR data collection, however, is now in jeopardy given there are no planned future Earth observing TIR remote sensing satellite systems with moderately high spatial resolutions to replace those currently in orbit on NASA's Terra suite of sensors. This session will convene researchers who have actively worked in the field of TIR remote sensing to present results that elucidate the importance of thermal remote sensing to the wider Earth science research community. Additionally, this session will also exist as a forum for presenting concepts and ideas for new thermal sensing systems with high spatial resolutions for future Earth science satellite missions, as opposed to planned systems such as the Visible/Infrared Imager/Radiometer (VIIRS) suite of sensors on the National Polar-orbiting Operational Environmental Satellite System (NPOESS) that will collect TIR data at very coarse ~~~iairesolutions.

Quattrochi, Dale a.↗

Continuous data stream FIFO magnetic bubble domain shift register

There is described a simple first-in, first out (FIFO) magnetic bubble domain shift register which has continuous data storage capability. In a preferred embodiment, two parallel detector branches are associated with a main storage loop. The bubbles in the storage loop are replicated toward each detector branch by passive replicators in the storage loop. Annihilators associated with each of the replicators and each of the detectors are arranged an appropriate distance from the replicators so that selective energization of the annihilators permits certain bits to propagate to one detector and other bits to propagate to the other detector. Connection of the detectors in an appropriate bridge circuit permits full data rate reclamation.

Chen, Thomas T.↗

Noise Radiation from a Continuous Mold-Line Link Flap Configuration

The results of an experimental study of the noise from a Continuous Mold-Line Link (CML) flap are presented. Acoustic and unsteady surface pressure measurements were performed on a main element wing section with a half-span CML flap in NASA Langley s Quiet Flow Facility. The acoustic data were acquired with a medium aperture directional array (MADA) of microphones. The Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) method is applied to determine the spatial distribution and strength of the noise sources over the surface of the test model. A Coherent Output Power (COP) method which relates the output from unsteady surface pressure sensors to the output of the MADA is also used to obtain more detailed characteristics of the noise source distribution in the trailing edge region of the CML. These results are compared to those obtained for a blunt flap to quantify the level of noise benefit that is achieved with the CML flap. The results indicate that the noise from the CML region of the flap is 5 to 17 dB lower (depending on flap deflection and Mach number) than the noise from the side edge region of the blunt flap. Lower noise levels are obtained for all frequencies. Spectral analysis of the noise from the cove region of the CML and blunt flap models also reveal a spectral peak in the high frequency range that is related to noise scattering at the trailing edge of the main element. The peaks in the CML and blunt flap cove noise spectra are close in level and often exceed blunt side edge noise. Applying a strip of serrated tape to the trailing edge of the CML flap model main airfoil, reduced the peak but increased other noise somewhat. Directivity measurements show that the CML flap can be more directional than the blunt flap.

Hutcheson, Florence V.↗

Neural Networks as a Tool for Constructing Continuous NDVI Time Series from AVHRR and MODIS

The long term Advanced Very High Resolution Radiometer-Normalized Difference Vegetation Index (AVHRR-NDVI) record provides a critical historical perspective on vegetation dynamics necessary for global change research. Despite the proliferation of new sources of global, moderate resolution vegetation datasets, the remote sensing community is still struggling to create datasets derived from multiple sensors that allow the simultaneous use of spectral vegetation for time series analysis. To overcome the non-stationary aspect of NDVI, we use an artificial neural network (ANN) to map the NDVI indices from AVHRR to those from MODIS using atmospheric, surface type and sensor-specific inputs to account for the differences between the sensors. The NDVI dynamics and range of MODIS NDVI data at one degree is matched and extended through the AVHRR record. Four years of overlap between the two sensors is used to train a neural network to remove atmospheric and sensor specific effects on the AVHRR NDVI. In this paper, we present the resulting continuous dataset, its relationship to MODIS data, and a validation of the product.

Brown, Molly E.↗

The Use of Simulated Visible/Infrared Imager/Radiometer Suite (VIIRS) and Landsat Data Continuity Mission (LDCM) Imagery for Coral Reef Monitoring

Coral reefs are some of the most biologically rich and economically important ecosystems on Earth. Coral reefs are Earth's largest biological structures and have taken thousands of years to form. Coral reefs not only provide important habitat for many marine animals and plants, but they also provide humanity with food, jobs, chemicals, protection against storms, and life-saving pharmaceuticals. Severe bleaching events have occurred that have dramatic long-term ecological impacts to corals, including loss of reef-building corals, changes in benthic habitat, and, in some cases, changes in larval fish populations (Holden and Ledrew, 1998). Some researchers suggest that 10 percent of Earth s coral reefs have already been destroyed and that another 60 percent are in danger. Scientists have proposed that as much as 95 percent of Jamaica's reefs are dying or dead. This poster reports on a Rapid Prototyping Capability (RPC) experiment done to determine whether future NASA sensors - the Visible/Infrared Imager/Radiometer Suite (VIIRS) and Landsat Data Continuity Mission (LDCM) - could generate key data products for the Integrated Coral Reef Observation Network (ICON)/Coral Reef Early Warning System (CREWS) Decision Support Tool (DST) operated by the National Oceanic and Atmospheric Administration (NOAA).

Estep, L.↗

An Operational Land Imager for the Landsat Data Continuity Mission

The National Aeronautics and Space Administration (NASA) released a request for proposals (RFP) on January 09, 2007 for an Operational Land Imager (OLI). The RFP specified the OLI as the principal sensor for the Landsat Data Continuity Mission (LDCM), the successor mission to Landsat 7. The RFP provides requirements for OLI performance, special calibration tests, and mission assurance without specifying a particular technical design. The performance specifications derive from the heritage and societal benefits of data from the previous Landsat satellites, the high standards set by the performance of the Landsat 7 Enhanced Thematic Mapper-Plus, direction from the Executive Office of the President, cognizance of current technology, and an eye to the future of land remote sensing beyond the LDCM. The specification includes nine spectral bands (four visible, one near infrared, three shortwave infrared, and one panchromatic band), spatial resolution of 30 m with the exception of a 15 m panchromatic resolution, stringent radiometric performance and absolute calibration, and accurate image geolocation with precise band-to-band and multitemporal image-to-image registration. Proposals were due on February 23, 2007 with selection and contract award anticipated by June 2007. The RFP requires delivery of a well-characterized instrument for spacecraft integration within 39 months of contract award. This schedule leads to a target LDCM launch date of July, 2011.

Irons, James R.↗

Continued Development of the Advanced Stirling Convertor (ASC)

The Advanced Stirling Convertor (ASC) is being developed under contract with the NASA Glenn Research Center (GRC) and is supported by NASA s Science Mission Directorate for potential use in future radioisotope power systems having significantly increased efficiency and higher specific power compared to the current thermoelectric systems. An ASC with a lower temperature (approx.650 C) Inconel heater head is currently being substituted into the DOE/Lockheed Martin Advanced Stirling Radioisotope Generator (ASRG) program with a predicted convertor efficiency of 34 percent (AC electrical out to heat input ) at a temperature ratio of 2.7 and is expected to deliver approximately 75 W(sub ac). Continued development of the higher temperature (approx.850 C) version using existing materials and fabrication techniques in the hot portions is reported on here. The higher temperature ASC is expected to have 38 percent efficiency (AC electrical out to heat input) at a temperature ratio of 3.1 and is expected to deliver approximately 88 W(sub ac). The high temperature ASC also has approximately 30 C higher rejection temperature, which allows for further reduced system mass because of the reduced radiator size. Six higher temperature and hermetically sealed convertors are being built under this effort for extended life testing at GRC.

Wong, Wayne A.↗

Landsat Data Continuity Mission Calibration and Validation

The primary payload for the Landsat Data Continuity Mission (LDCM) is the Operational Land Imager (OLI), being built by Ball Aerospace and Technologies, under contract to NASA. The OLI has spectral bands similar to the Landsat-7 ETM+, minus the thermal band and with two new bands, a 443 nm band and 1375 nm cirrus detection band. On-board calibration systems include two solar diffusers (routine and pristine), a shutter and three sets of internal lamps (routine, backup and pristine). Being a pushbroom opposed to a whiskbroom design of ETM+, the system poses new challenges for characterization and calibration, chief among them being the large focal plane with 75000+ detectors. A comprehensive characterization and calibration plan is in place for the instrument and the data throughout the mission including Ball, NASA and the United States Geological Survey, which will take over operations of LDCM after on-orbit commissioning. Driving radiometric calibration requirements for OLI data include radiance calibration to 5% uncertainty (1 q); reflectance calibration to 3% uncertainty (1 q) and relative (detector-to-detector) calibration to 0.5% (J (r). Driving geometric calibration requirements for OLI include bandto- band registration of 4.5 meters (90% confidence), absolute geodetic accuracy of 65 meters (90% CE) and relative geodetic accuracy of 25 meters (90% CE). Key spectral, spatial and radiometric characterization of the OLI will occur in thermal vacuum at Ball Aerospace. During commissioning the OLI will be characterized and calibrated using celestial (sun, moon, stars) sources and terrestrial sources. The USGS EROS ground processing system will incorporate an image assessment system similar to Landsat-7 for characterization and calibration. This system will have the added benefit that characterization data will be extracted as part of the normal image data processing, so that the characterization data available will be significantly larger than for Landsat-7 ETM+.

Markham, Brian L.↗

Continuous-Flow System Produces Medical-Grade Water

A continuous-flow system utilizes microwave heating to sterilize water and to thermally inactivate endotoxins produced in the sterilization process. The system is designed for use in converting potable water to medical-grade water. Systems like this one could be used for efficient, small-scale production of medical- grade water in laboratories, clinics, and hospitals. This system could be adapted to use in selective sterilization of connections in ultra-pure-water-producing equipment and other equipment into which intrusion by microorganisms cannot be tolerated. Lightweight, port - able systems based on the design of this system could be rapidly deployed to remote locations (e.g., military field hospitals) or in response to emergencies in which the normal infrastructure for providing medical-grade water is disrupted. Larger systems based on the design of this system could be useful for industrial production of medical-grade water. The basic microwave-heating principle of this system is the same as that of a microwave oven: An item to be heated, made of a lossy dielectric material (in this case, flowing water) is irradiated with microwaves in a multimode microwave cavity. The heating is rapid and efficient because it results from absorption of microwave power throughout the volume of the lossy dielectric material. In this system, a copper tube having a length of 49.5 cm and a diameter of 2.25 cm serves as both the microwave cavity and the sterilization chamber. Microwave power is fed via a coaxial cable to an antenna mounted inside the tube at mid-length (see figure). Efficient power transfer occurs due to the shift in wavelength associated with the high permittivity of water combined with the strong coupling of 2.45-GHz microwaves with rotational-vibrational transitions of the dipolar water molecule.

Akse, James R.↗

Probabilistic Multi-Factor Interaction Model for Evaluating Continuous Smooth Curves

The Multi-Factor Interaction Model (MFIM) is used to evaluate the divot weight (foam weight ejected) from launch external tanks. The MFIM has sufficient degrees of freedom to evaluate a large number of factors that may contribute to the divot ejection. It also accommodates all interactions by its product form. Each factor has an exponent that satisfies only two points the initial and final points. They are selected so that the MFIM will generate a common curve to fit the individual point data. The results show that the approach used generates the continuous curve.

Chamis, Christos C.↗

Evaluation of an Airborne Spacing Concept to Support Continuous Descent Arrival Operations

This paper describes a human-in-the-loop experiment of an airborne spacing concept designed to support Continuous Descent Arrival (CDA) operations. The use of CDAs with traditional air traffic control (ATC) techniques may actually reduce an airport's arrival throughput since ATC must provide more airspace around aircraft on CDAs due to the variances in the aircraft trajectories. The intent of airborne self-spacing, where ATC delegates the speed control to the aircraft, is to maintain or even enhance an airport s landing rate during CDA operations by precisely achieving the desired time interval between aircraft at the runway threshold. This paper describes the operational concept along with the supporting airborne spacing tool and the results of a piloted evaluation of this concept, with the focus of the evaluation on pilot acceptability of the concept during off-nominal events. The results of this evaluation show a pilot acceptance of this airborne spacing concept with little negative performance impact over conventional CDAs.

Murdoch, Jennifer L.↗

Landsat Data Continuity Mission (LDCM) - Optimizing X-Band Usage

The NASA version of the low-density parity check (LDPC) 7/8-rate code, shortened to the dimensions of (8160, 7136), has been implemented as the forward error correction (FEC) schema for the Landsat Data Continuity Mission (LDCM). This is the first flight application of this code. In order to place a 440 Msps link within the 375 MHz wide X band we found it necessary to heavily bandpass filter the satellite transmitter output . Despite the significant amplitude and phase distortions that accompanied the spectral truncation, the mission required BER is maintained at < 10(exp -12) with less than 2 dB of implementation loss. We utilized a band-pass filter designed ostensibly to replicate the link distortions to demonstrate link design viability. The same filter was then used to optimize the adaptive equalizer in the receiver employed at the terminus of the downlink. The excellent results we obtained could be directly attributed to the implementation of the LDPC code and the amplitude and phase compensation provided in the receiver. Similar results were obtained with receivers from several vendors.

Garon, H. M.↗

Fiber-Optic Continuous Liquid Sensor for Cryogenic Propellant Gauging

An innovative fiber-optic sensor has been developed for low-thrust-level settled mass gauging with measurement uncertainty <0.5 percent over cryogenic propellant tank fill levels from 2 to 98 percent. The proposed sensor uses a single optical fiber to measure liquid level and liquid distribution of cryogenic propellants. Every point of the sensing fiber is a point sensor that not only distinguishes liquid and vapor, but also measures temperature. This sensor is able to determine the physical location of each point sensor with 1-mm spatial resolution. Acting as a continuous array of numerous liquid/vapor point sensors, the truly distributed optical sensing fiber can be installed in a propellant tank in the same manner as silicon diode point sensor stripes using only a single feedthrough to connect to an optical signal interrogation unit outside the tank. Either water or liquid nitrogen levels can be measured within 1-mm spatial resolution up to a distance of 70 meters from the optical interrogation unit. This liquid-level sensing technique was also compared to the pressure gauge measurement technique in water and liquid nitrogen contained in a vertical copper pipe with a reasonable degree of accuracy. It has been demonstrated that the sensor can measure liquid levels in multiple containers containing water or liquid nitrogen with one signal interrogation unit. The liquid levels measured by the multiple fiber sensors were consistent with those virtually measured by a ruler. The sensing performance of various optical fibers has been measured, and has demonstrated that they can survive after immersion at cryogenic temperatures. The fiber strength in liquid nitrogen has also been measured. Multiple water level tests were also conducted under various actual and theoretical vibration conditions, and demonstrated that the signal-to-noise ratio under these vibration conditions, insofar as it affects measurement accuracy, is manageable and robust enough for a wide variety of spacecraft applications. A simple solution has been developed to absorb optical energy at the termination of the optical sensor, thereby avoiding any feedback to the optical interrogation unit

Xu. Wei↗

The Thermal Infrared Sensor on the Landsat Data Continuity Mission

The Landsat Data Continuity Mission (LDCM), a joint NASA and USGS mission, is scheduled for launch in December, 2012. The LDCM instrument payload will consist of the Operational Land Imager (OLI), provided by Ball Aerospace and Technology Corporation (BATC} under contract to NASA and the Thermal Infrared Sensor (TIRS), provided by NASA's Goddard Space Flight Center (GSFC). This paper outlines the design of the TIRS instrument and gives an example of its application to monitoring water consumption by measuring evapotranspiration.

Reuter, Dennis↗

A Comparison of MERRA and NARR Reanalysis Datasets with the DOE ARM SGP Continuous Forcing data

In this study, the atmospheric state, precipitation, cloud fraction, and radiative fluxes from Modern Era Retrospective-analysis for Research and Applications (MERRA) and North American Regional Reanalysis (NARR) are collected and compared with the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) continuous forcing during the period 1999-2001. For the atmospheric state, the three datasets have excellent agreement for the horizontal wind components and air temperature. NARR and ARM have generally good agreement for humidity, except for several biases in the PBL and in the upper troposphere. MERRA, on the other hand, suffers from a year-round negative bias in humidity except for the month of June. For the vertical pressure velocity, significant differences exist with the largest biases occurring during the spring upwelling and summer downwelling periods. Although NARR and MERRA share many resemblances to each other, ARM outperforms these reanalyses in terms of correlation with cloud fraction. Because the ARM forcing is constrained by observed precipitation that gives the adequate mass, heat, and moisture budgets, much of the precipitation (specifically during the late spring/early summer) is caused by smaller-scale forcing that is not captured by the reanalyses. Both NARR and MERRA capture the seasonal variation of CF observed by ARM radar-lidar and GOES with high correlations (0.92-0.78), but having negative biases of 14% and 3%, respectively. Compared to the ARM observations, MERRA shows a better agreement for both SW and LW fluxes except for LW-down (due to a negative bias in water vapor), NARR has significant positive bias for SW-down and negative bias for LW-down under clear- and all-sky conditions . The NARR biases result from a combination of too few clouds and a lack of sufficient extinction by aerosols and water vapor in the atmospheric column. The results presented here represent only one location for a limited time period, and more comparisons at different locations and longer time period are needed.

Kennedy, Aaron D.↗

Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

Pappas, D.↗

An Event-Based Approach to Distributed Diagnosis of Continuous Systems

Distributed fault diagnosis solutions are becoming necessary due to the complexity of modern engineering systems, and the advent of smart sensors and computing elements. This paper presents a novel event-based approach for distributed diagnosis of abrupt parametric faults in continuous systems, based on a qualitative abstraction of measurement deviations from the nominal behavior. We systematically derive dynamic fault signatures expressed as event-based fault models. We develop a distributed diagnoser design algorithm that uses these models for designing local event-based diagnosers based on global diagnosability analysis. The local diagnosers each generate globally correct diagnosis results locally, without a centralized coordinator, and by communicating a minimal number of measurements between themselves. The proposed approach is applied to a multi-tank system, and results demonstrate a marked improvement in scalability compared to a centralized approach.

Daigle, Matthew↗