Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coded source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

(U) A General-Purpose Code for Correlated Sampling Using Batch Statistics with MCNP6 for Fixed-Source Problems

Correlated sampling can be used to reduce the uncertainty of a difference of tallies by taking advantage of the negative covariance term in the sandwich formula. Booth first showed how correlated sampling can be applied with batch statistics using MCNP’s tally fluctuation chart (TFC) to reduce the uncertainty of a difference of tallies in fixed-source problems. Booth presented a problem in which a 1273% uncertainty in a difference was reduced to 8% by accounting for correlations. Researchers He and Su recently studied correlated sampling using the TFC in MCNP version 5. They determined that the code did not print enough digits in the TFC tally means for accurate batch statistics in some cases. After modifying the source code, they concluded that “correlated sampling can yield a standard deviation of about one magnitude smaller than that predicted by the direct, un-correlated simulation when the changes in system response are small (say about 1%), which is equivalent to saving in CPU time by a factor of 100. Such saving [sic] becomes less significant as the change in system response becomes larger.” He and Su provided the formulas needed to apply batch statistics to compute the correlated uncertainty of a difference of tallies. In this report, we follow up on their work by providing the formulas needed to apply batch statistics to compute the correlated uncertainty of a ratio of tallies and of a difference of two tallies divided by a third tally. We extend these formulas to differences and ratios of ratios. These formulas are applied to reduce the uncertainty associated with calculating a relative sensitivity. He and Su did not investigate the accuracy of their correlated sampling uncertainty estimates. We use their test problems and evaluate the accuracy of the uncertainty estimates by comparing with results obtained from random sampling, and, in simple cases, with theoretical values of the “exact” uncertainties. We find that the uncertainties obtained from batch statistics are accurate as long as at least 100 batches are used. We present a new computer code, COSUBS (COrrelated Sampling Using Batch Statistics), that reads MCNP6 TFCs and applies correlated sampling using batch statistics for the tally combinations that the user specifies. COSUBS is a very general tool that compares all TFCs for a base case and one or two perturbed cases. It computes uncertainties for ratios if given only a base case. This report is organized as follows. The equations to apply batch statistics to the difference of random tallies are reviewed in Sec. II. Section III presents the equations for applying batch statistics to a ratio of random tallies; this is useful for computing relative sensitivities using a one-sided finite difference and the relative sensitivity using the differential operator method. Section IV presents the equations for applying batch statistics to a difference of two random tallies divided by a third; this is useful for computing a relative sensitivities using a central difference. Section V presents the equations for applying batch statistics to a difference of two ratios with four random tallies. Section VI presents the equations for applying batch statistics to a one-sided finite difference estimate of the relative sensitivity of a ratio (this uses four random tallies). Section VII presents the equations for applying batch statistics to a central difference estimate of the relative sensitivity of a ratio (this uses six random tallies). Section VIII presents the equations for applying batch statistics to a sum of random tallies. Section IX discusses how to apply batch statistics using MCNP6. Section X presents COSUBS, describing its command-line options and logic. Sections XI through XVI present numerical results for various test problems. Section XVII is a summary and conclusions. Appendix A derives the theoretical Monte Carlo tally variance given certain assumptions; these variances are used to verify the batch statistics for some of the problems. Appendix B lists the MCNP6 input for the unperturbed example problem. Appendix C presents modifications made to MCNP6.3 to support this work.

97 MATHEMATICS AND COMPUTING↗

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer’s compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic translation of MPI source into a latency-tolerant, data-driven form

Hiding communication behind useful computation is an important performance programming technique but remains an inscrutable programming exercise even for the expert. We present Bamboo, a code transformation framework that can realize communication overlap in applications written in MPI without the need to intrusively modify the source code. Bamboo reformulates MPI source into the form of a task dependency graph that expresses a partial ordering among tasks, enabling the program to execute in a data-driven fashion under the control of an external runtime system. Experimental results demonstrate that Bamboo significantly reduces communication delays while requiring only modest amounts of programmer annotation for a variety of applications and platforms, including those employing co-processors and accelerators. Moreover, Bamboo's performance meets or exceeds that of labor-intensive hand coding. The translator is more than a means of hiding communication costs automatically; it demonstrates the utility of semantic level optimization against a wellknown library.

Communication-computation↗

SCALE Enhancements for Detailed Cask Dose Rate Analysis - Paper 37

The Nuclear Fuels Storage and Transportation Planning Project and the Used Fuel Disposition Campaign, both under the US Department of Energy (DOE) Office of Nuclear Energy, require the ability to predict k{sub eff}, heat generation and temperature distributions, and external dose rates from any combination of commercial spent nuclear fuel assemblies loaded into any type of licensed cask. Work in the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory has begun to develop the UNF-ST[and]DARDS system (Used Nuclear Fuel Storage, Transportation and Disposal Analysis Resource and Data System) that uses many of the nuclear analysis codes from the SCALE package, a comprehensive database of used nuclear fuel inventories from utilities, and a library of model template files to produce complete input files for the various types of UNF computational analyses. UNF-ST[and]DARDS uses the template files and input parameters that are applicable to a safety analysis to assemble and execute a complete input file, collect the output files and relevant information for subsequent calculations, and illustrate calculation results as a function of decay time and other relevant analysis parameters. This paper will focus on the shielding aspects and the ability to predict external dose rates from as-loaded casks. Realistic dose rate values based on actual canister fuel contents may be used in developing appropriate plans, procedures, and methods to keep personnel radiation exposures as low as reasonably achievable during cask repackaging and transportation operations, as well as in performing total system analyses and transportation risk evaluations. The MAVRIC shielding sequence of the SCALE package was created for the US Nuclear Regulatory Commission for analyzing dose rates outside of storage, transfer, or transportation casks loaded with spent nuclear fuel. MAVRIC contains automated variance reduction capabilities based on the CADIS and FW-CADIS methods that are effective for optimizing deep penetration Monte Carlo shielding problems for achieving low relative uncertainties in short computing times. MAVRIC uses the Denovo discrete ordinates code to compute importance maps and biased source terms for the Monaco fixed-source Monte Carlo code, which can use multi-group or continuous-energy cross section data. ORIGEN (Oak Ridge Isotope Generation and Depletion) is the SCALE computer code for calculating time-dependent isotopic concentrations during irradiation and decay for more than 2,200 nuclides that can be produced by nuclear fuel irradiation and activation. A series of SCALE enhancements was implemented to enable automatic decay heat and radiation source term generation and shielding safety analysis of as-loaded casks. The enhancements to SCALE made under this project will be a part of the SCALE 6.2 release expected in fall 2014. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Property of neoclassical GAMs induced by pellet generated plasma perturbations in the gyrokinetic code XGC

A pellet source model has been implemented into the gyrokinetic code XGC and applied to neoclassical geodesic acoustic mode (GAM) study as the first step to investigate potentially rapid kinetic spread of pellet-born particles following their injection into plasma. Here in this study, GAM oscillations of the radial electric field, as well as of their effect on the radial particle and energy fluxes, are studied and the observed frequencies agree with theoretical expectations. It is verified that (i) GAM oscillations are driven both within the pellet-fuelled region and for locations at a larger radius than this region and not for locations radially inside the pellet-fuelled region, and that, (ii) even though the poloidal spread along the magnetic field lines is fast, the time-averaged radial plasma transport under GAM oscillations is kept to roughly the same level as the neoclassical transport in the absence of plasma turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parser for Sabin-to-Mahoney Transition Model of Quasispecies Replication

This code is a data parse for preparing output from the Qspp agent-based stochastic simulation model for plotting in Excel. This code is specific to a set of simulations that were run for the purpose of preparing data for a publication. It is necessary to make this code open-source in order to publish the model code (Qspp), which has already been released. There is a necessity of assuring that results from using Qspp for a publication

Ecale Zhou, Carol↗

Parser for Sabin-to-Mahoney Transition Model of Quasispecies Replication

This code is a data parse for preparing output from the Qspp agent-based stochastic simulation model for plotting in Excel. This code is specific to a set of simulations that were run for the purpose of preparing data for a publication. It is necessary to make this code open-source in order to publish the model code (Qspp), which has already been released. There is a necessity of assuring that results from using Qspp for a publication

Ecale Zhou, Carol↗

Development of the computer code for multi-calculations of source term of spent fuel - 15351

Many PWR spent fuels have been transferred between the neighboring nuclear power plants at Kori, Hanbit, Hanwul site, and from nuclear power plant to the KAERI(Korea Atomic Energy Research Institute) for the research purpose in Korea. In case of the PHWR type spent fuels, these have been transferred from the spent fuel pool to an on-site dry storage facility. Total radioactivity of spent fuels has to be calculated before transport in advance by the regulation requirement. In case of PWR, KN-12 transport cask can transfer 12 spent fuel assemblies at one time and in case of PHWR, Hi-STAR 63 transport cask can transfer 120 spent fuel assemblies at one time. Therefore, total radioactivity of all transported spent fuel assemblies that are transported generally are calculated by using the ORIGEN-ARP to meet this regulatory requirement. Basically, ORIGEN-ARP calculates the one fuel assembly at one time. SCALE code including this code provides the batch mode to perform the multi-calculations of the source term. In this study, in order to use the batch mode of ORIGEN-ARP, ARP-auto program was developed to generate input files and batch file of ORIGEN-ARP automatically and to make the summary file extracting the result from output files of ORIGEN-ARP. This code enhances the efficiency at the field. The working time to complete the calculation of source terms of 120 spent fuel assemblies take only 20 minutes. In order to confirm the credibility of this code, total radioactivity of 12 spent fuel assemblies of 17x17 Westinghouse type were calculated and compared to the previous result. The initial enrichments of these spent fuels are 3.46 ∼ 3.50 w/o and burnups are 29 ∼ 43 GWD/MTU. As the results, the relative errors are about 0.9 ∼ 3.0%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data and Scripts associated with “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling.”

This data package is associated with the publication “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling” submitted to Geoscientific Model Development (Muller et al., 2024). In this manuscript, organic matter chemistry and thermodynamics are directly connected to reactive transport simulators through the newly developed Lambda-PFLOTRAN (Parallel Reactive Flow and Transport model) workflow tool that succinctly incorporates organic matter chemistry data generated from Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) into reaction networks to simulate aerobic respiration of the organic matter and the resulting biogeochemistry. Lambda-PFLOTRAN is a python-based workflow, executed through a Jupyter Notebook interface, that digests raw FTICR-MS data, develops a representative reaction network based on substrate-explicit thermodynamic modeling (also termed lambda modeling due to its key thermodynamic parameter λ used therein), and completes a biogeochemical simulation with the open source, reactive flow, and transport code PFLOTRAN. This data package contains Jupyter Notebook based workflows for two test cases for running biogeochemical simulations of organic matter oxidation identified by FTICR-MS. It contains four primary folders (workflow, data, src, and analysis), a file-level metadata file (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_flmd.csv) that lists all the files contained in this data package with a short description of each, and a data dictionary (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_dd.csv) file that describes the tabular column headers. The ‘workflow’ folder contains the Jupyter Notebook based workflows for running the lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘data’ folder contains the FTICR-MS data, initial conditions, and incubation data for test cases 1 and 2 in folders titled ‘WHONDRS’ and ‘Colloids’, respectively. The data folder also has a ‘Database’ folder containing a reaction network for bulk organic matter (assumed to be CH2O) and a general database for PFLOTRAN (hanford_rxn_network). The CH2O reaction network defines bulk organic matter oxidation. Biogeochemical simulations are completed for both the lambda binned organic matter and bulk organic matter reaction networks. The ‘hanford_rxn_network’ database includes information required for PFLTORAN simulations including ion size, molar mass, and charge of the aqueous species, gases, and minerals phases. The ‘src’ folder contains python source codes for performing lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘analysis’ folder contains outputs from the test cases 1 and 2 including lambda analysis, PFLOTRAN runs and the calibration results.

54 ENVIRONMENTAL SCIENCES↗

SICOPOLIS-AD v1: an open-source adjoint modeling framework for ice sheet simulation enabled by the algorithmic differentiation tool OpenAD

We present a new capability of the ice sheet model SICOPOLIS that enables flexible adjoint code generation via source transformation using the open-source algorithmic differentiation (AD) tool OpenAD.The adjoint code enables efficient calculation of the sensitivities of a scalar-valued objective function or quantity of interest (QoI) to a range of important, often spatially varying and uncertain model input variables, including initial and boundary conditions, as well as model parameters.Compared to earlier work on the adjoint code generation of SICOPOLIS, our work makes several important advances:(i) it is embedded within the up-to-date trunk of the SICOPOLIS repository – accounting for 1.5 decades of code development and improvements – and is readily available to the wider community;(ii) the AD tool used, OpenAD, is an open-source tool;(iii) the adjoint code developed is applicable to both Greenland and Antarctica, including grounded ice as well as floating ice shelves, with an extended choice of thermodynamical representations.A number of code refactorization steps were required. They are discussed in detail in an Appendix as they hold lessons for the application of AD to legacy codes at large.As an example application, we examine the sensitivity of the total Antarctic Ice Sheet volume to changes in initial ice thickness, austral summer precipitation, and basal and surface temperatures across the ice sheet.Simulations of Antarctica with floating ice shelves show that over 100 years of simulation the sensitivity of total ice sheet volume to the initial ice thickness and precipitation is almost uniformly positive, while the sensitivities to surface and basal temperature are almost uniformly negative. Sensitivity to austral summer precipitation is largest on floating ice shelves from Queen Maud to Queen Mary Land. The largest sensitivity to initial ice thickness is at outlet glaciers around Antarctica. Comparison between total ice sheet volume sensitivities to surface and basal temperature shows that surface temperature sensitivities are higher broadly across the floating ice shelves, while basal temperature sensitivities are highest at the grounding lines of floating ice shelves and outlet glaciers. A uniformly perturbed region of East Antarctica reveals that, among the four control variables tested here, total ice sheet volume is the most sensitive to variations in austral summer precipitation as formulated in SICOPOLIS.Comparison between adjoint- and finite-difference-derived sensitivities shows good agreement, lending confidence that the AD tool is producing correct adjoint code.The new modeling infrastructure is freely available at http://www.sicopolis.net (last access: 2 April 2020) under the development trunk.

58 GEOSCIENCES↗

Titanium alloy response sensitivity to variations in spectral reconstructions of National Ignition Facility xenon line-emission x-ray sources

Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.

Alloys↗

SU-F-T-28: Evaluation of BEBIG HDR Co-60 After-Loading System for Skin Cancer Treatment Using Conical Surface Applicator

Purpose: To evaluate the possibility of utilizing the BEBIG HDR 60Co remote after-loading system for malignant skin surface treatment using Monte Carlo (MC) simulation technique. Methods: First TG-43 parameters of BEBIG-Co-60 and Nucletron Ir-192-mHDR-V2 brachytherapy sources were simulated using MCNP6 code to benchmark the sources against the literature. Second a conical tungsten-alloy with 3-cm diameter of Planning-Target-Volume (PTV) at surface for use with a single stepping HDR source is designed. The HDR source is modeled parallel to treatment plane at the center of the conical applicator with a source surface distance (SSD) of 1.5-cm and a removable plastic end-cap with a 1-mm thickness. Third, MC calculated dose distributions from HDR Co-60 for conical surface applicator were compared with the simulated data using HDR Ir-192 source. The initial calculations were made with the same conical surface applicator (standard-applicator) dimensions as the ones used with the Ir-192 system. Fourth, the applicator wall-thickness for the Co-60 system was increased (doubled) to diminish leakage dose to levels received when using the Ir-192 system. With this geometry, percentage depth dose (PDD), and relative 2D-dose profiles in transverse/coronal planes were normalized at 3-mm prescription-depth evaluated along the central axis. Results: PDD for Ir-192 and Co-60 were similar with standard and thick-walled applicator. 2D-relative dose distribution of Co-60, inside the standard-conical-applicator, generated higher penumbra (7.6%). For thick-walled applicator, it created smaller penumbra (<4%) compared to Ir-192 source in the standard-conicalapplicator. Dose leakage outside of thick-walled applicator with Co-60 source was approximately equal (≤3%) with standard applicator using Ir-192 source. Conclusion: Skin cancer treatment with equal quality can be performed with Co-60 source and thick-walled conical applicators instead of Ir-192 with standard applicators. These conical surface applicator must be used with a protective plastic end-cap to eliminate electron contamination and over-dosage of the skin.

60 APPLIED LIFE SCIENCES↗

shiftNMFk 1.1: Robust Nonnegative matrix factorization with kmeans clustering and signal shift, for allocation of unknown physical sources, toy version for open sourcing with publications

This code is a toy (short) version of CODE-2016-83. From a general perspective, the code represents an unsupervised adaptive machine learning algorithm that allows efficient and high performance de-mixing and feature extraction of a multitude of non-negative signals mixed and recorded by a network of uncorrelated sensor arrays. The code identifies the number of the mixed original signals and their locations. Further, the code also allows deciphering of signals that have been delayed in regards to the mixing process in each sensor. This code is high customizable and it can be efficiently used for a fast macro-analyses of data. The code is applicable to a plethora of distinct problems: chemical decomposition, pressure transient decomposition, unknown sources/signal allocation, EM signal decomposition. An additional procedure for allocation of the unknown sources is incorporated in the code.

Alexandrov, BoianS.↗

shiftNMFk 1.1: Robust Nonnegative matrix factorization with kmeans clustering and signal shift, for allocation of unknown physical sources, toy version for open sourcing with publications

This code is a toy (short) version of CODE-2016-83. From a general perspective, the code represents an unsupervised adaptive machine learning algorithm that allows efficient and high performance de-mixing and feature extraction of a multitude of non-negative signals mixed and recorded by a network of uncorrelated sensor arrays. The code identifies the number of the mixed original signals and their locations. Further, the code also allows deciphering of signals that have been delayed in regards to the mixing process in each sensor. This code is high customizable and it can be efficiently used for a fast macro-analyses of data. The code is applicable to a plethora of distinct problems: chemical decomposition, pressure transient decomposition, unknown sources/signal allocation, EM signal decomposition. An additional procedure for allocation of the unknown sources is incorporated in the code.

Alexandrov, Boian S.↗

PFLOTRAN-RepoTREND Source Term Comparison Summary.

Code inter-comparison studies are useful exercises to verify and benchmark independently developed software to ensure proper function, especially when the software is used to model high-consequence systems which cannot be physically tested in a fully representative environment. This summary describes the results of the first portion of the code inter-comparison between PFLOTRAN and RepoTREND, which compares the radionuclide source term used in a typical performance assessment.

97 MATHEMATICS AND COMPUTING↗

Development of an Integrated Mechanistic Source Term Assessment Capability for Lead- and Sodium-Cooled Fast Reactors

The scope of this project entails development of mechanistic source term assessment capabilities to inform and guide plant design activities and to support license applications. The main objective of this project is to couple NL’s SAS4A safety analysis code with the FAI’s FATE facility modeling code for mechanistic source term assessments in liquid-metal-cooled fast reactors. The end product is a coupled SAS4A-FATE code system for integrated mechanistic source term assessments and Level-2 PRA as the precursor for off-site dispersion analyses (Level-3 PRA). The SAS4A code is used to model system transients with fuel failures and its results are linked to the FATE code to predict radionuclide transport through the reactor vessel cover gas and containment system. The integrated code package offers a state-of-the-art radionuclide tracking capability for a spectrum of accident scenarios consistent with the plant dynamic response including the reactivity feedback to support Probabilistic Risk Assessments (PRA).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nonlinear Optimization in "Synchrotron Radiation Workshop" Code

"Synchrotron Radiation Workshop" (SRW) is an open source physical optics computer code for calculation of detailed characteristics of Synchrotron Radiation (SR) generated by relativistic electrons in magnetic fields of arbitrary configuration. SRW also supports high-accuracy simulations of fully- and partially-coherent radiation propagation through X-ray optical beamlines, facilitated by so-called “Virtual Beamline” module. In this present tech note, we discuss the nonlinear optimization features of SRW with emphasis on the optimization library in SRW. This optimization library not only can be used to optimize the simulation beamline in SRW, it also can be integrated with real beamline operations and optimize the parameters based on real measurements. We also show some demos of the optimization library recently developed in SRW.

36 MATERIALS SCIENCE↗

Recent Advances in the Use of TRIPOLI-4 Monte Carlo Code for Radiation Protection and Shielding Calculations - Paper 47

TRIPOLI-4 is a general purpose radiation transport code. It uses the continuous-energy Monte Carlo method to simulate neutron, photon, electron and positron transport in three-dimensional geometries. The main application areas of TRIPOLI-4 code include radiation protection and shielding, fission reactor physics, nuclear criticality safety, fusion reactor design, and nuclear instrumentation. For the radiation protection and shielding calculations with TRIPOLI-4 code, miscellaneous radiation sources options, various variance reduction options, and many useful tally options are available. Perturbation calculations on material densities and nuclide concentrations are routinely used in radiation protection applications. Parallel calculations with TRIPOLI-4 are also easy to perform with a PC under the linux/unix OS. To help the users to get the feedback from their test runs during the input data preparation and adjustment and to analyze the intermediate and final results from their production runs, several user-interface tools have been introduced. By using some application cases in the fields of radiation shielding, radiation dosimetry, and gamma spectrometry, this paper summarizes and demonstrates some essential improvements and possibilities in the use of TRIPOLI-4 code on fixed source calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗