Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “application benchmarks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Finding a common ground for RCM experiments. Part B: Benchmark study on ethanol ignition

Rapid compression machines (RCMs) are widely used to investigate gas phase reaction kinetics of various kind of fuels at application relevant conditions. In principle, the operation of an RCM is based on the idea of compressing a homogenous pre-mixed fuel-air mixture by a piston. Usually creviced pistons ensure a homogenous adiabatic core in the center of the reaction chamber which permits the assumption of an isentropic relation between the measured pressure and gas temperature. Despite the ideal core gas compression, non-ideal effects such as heat loss, differences in the compression behavior, and ultimately non-standardized design and operation of rapid compression machines lead to different experimental results in different facilities at nominally the same end of compression conditions. In this study ignition delay times of ethanol are investigated at four different conditions in five independent RCMs. As expected, the raw results of the different facilities indeed show notable differences at the same end of compression conditions. However, according to the adiabatic core hypothesis the agreement between kinetic simulations and experiments should be consistent for all facilities provided that the facility effects are correctly accounted for. To elaborate upon this hypothesis, a kinetic mechanism is optimized to reflect the experimental results of all facilities. In the end, the optimized mechanism predicts all experimental data within the expected uncertainty. This confirms the reliability of RCM experiments for kinetic investigations and the validity of the effective volume approach in simulating RCM data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systematic design of active spaces for multi-reference calculations of singlet–triplet gaps of organic diradicals, with benchmarks against doubly electron-attached coupled-cluster data

Singlet–triplet gaps in diradical organic π-systems are of interest in many applications. In this work, we calculate them in a series of molecules, including cyclobutadiene and its derivatives and cyclopentadienyl cation, by using correlated participating orbitals within the complete active space (CAS) and restricted active space (RAS) self-consistent field frameworks, followed by second-order perturbation theory (CASPT2 and RASPT2). These calculations are evaluated by comparison with the results of doubly electron-attached (DEA) equation-of-motion (EOM) coupled-cluster (CC) calculations with up to 4-particle–2-hole (4p-2h) excitations. Finally, we find active spaces that can accurately reproduce the DEA-EOMCC(4p-2h) data while being small enough to be applicable to larger organic diradicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ASSESSMENT OF MULTIPHASE CFD WITH ZERO CLOSURE MODEL FOR BOILING WATER REACTOR FUEL ASSEMBLIES

Extension of existing boiling closures to the high void fraction conditions of BWRs is one of challenges for M-CFD applications. This paper presents the assessment of an Eulerian M-CFD model with Zero closure model that has been specifically designed for two-phase flow and heat transfer applications in BWR fuel assemblies. The baseline Zero closure aims at including the simplest and most robust representation of the key physical mechanisms, rather than aiming at absolute accuracy of the predictions. The capabilities of M-CFD with Zero were evaluated against the international OECD/NRC BFBT benchmark data through the comparative analyses of local void fraction, sub-channel void fraction error and exit quality. INL high performance computing system has been employed to demonstrate the scalability of the M-CFD application to nuclear reactor fuel assemblies. The M-CFD simulation results show a good agreement with the experimental data for both quantitative and qualitative results, with the highest uncertainty being observed in the prediction of the local void fraction profile at low void fraction condition. This paper presents a recent view of the best practices for M-CFD of BWR fuel assemblies to provide a useful reference to identify and overcome common challenges in the applications of M-CFD tools. We provide recommendations for geometric modeling, mesh generation and solver configurations to optimize the methodology application.

97 MATHEMATICS AND COMPUTING↗

Frontiers of the Physics of Dense Plasmas and Planetary Interiors: Experiment, Theory, Applications

We review recent developments of dynamic x-ray characterization experiments of dense matter, with particular emphasis on conditions relevant to interiors of terrestrial and gas giant planets. These studies include characterization of compressed states of matter in light elements by x-ray scattering and imaging of shocked iron by radiography. We examine several applications of this work. These include the structure of massive 'Super Earth' terrestrial planets around other stars, the 40 known extrasolar gas giants with measured masses and radii, and Jupiter itself, which serves as our benchmark for giant planets. We are now in an era of dramatic improvement in our knowledge of the physics of materials at high density. For light elements, this theoretical and experimental work has many applications, including internal confinement fusion as well as the interiors of gas giant planets. For heavy elements, experiments on silicates and iron at high pressure are helping to better understand the Earth, as well as terrestrial planets as a class of objects. In particular, the discovery of rocky and gaseous planets in other planetary systems has opened our imaginations to planets not found in our own solar system. While the fields of experiments of matter at high densities, first principles calculations of equations of state (EOS), planetary science, and astronomy do progress independently of each other, it is important for there to be communication between fields. For instance, in the realm of planets, physicists can learn of key problems that exist in the area of planetary structure, and how advances in our understanding of input physics could shed new light in this area. Astronomers and planetary scientists can learn where breakthroughs in physics of materials under extreme conditions are occurring, and be ready to apply these findings within their fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmark microgravity experiments and computations for 3D dendritic-array stability in directional solidification

In this study, we present a comprehensive quantitative analysis of stability bands for dendritic arrays during directional solidification of a transparent succinonitrile-0.46 wt % camphor alloy, spanning a broad range of pulling velocities. Taking advantage of the microgravity environment aboard the International Space Station where most convection effects are suppressed, we obtain unique measurements that quantify the stable primary spacing range of spatially extended three-dimensional dendritic array structures under purely diffusive growth conditions. Through carefully designed velocity jump experiments and detailed examination of sub-grain boundary dynamics, we characterize key instabilities, including elimination and tertiary branching, shedding new light on the mechanisms governing dynamic dendritic spacing selection in extended 3D arrays. Phase field simulations are performed to characterize the stability limits of dendritic array structures for quantitative comparison with the flight experiments. Although the simulations capture general trends, significant deviations are noted at the upper stability boundary, indicating the influence of additional, unexplored factors. These findings contribute to a deeper understanding of dendritic growth dynamics and offer valuable benchmark data that could aid in refining predictive models and improving control of dendritic microstructures in metallurgical applications.

36 MATERIALS SCIENCE↗

Comparative evaluation of deep learning workloads for leadership-class systems

Deep learning (DL) workloads and their performance at scale are becoming important factors to consider as we design, develop and deploy next-generation high-performance computing systems. Since DL applications rely heavily on DL frameworks and underlying compute (CPU/GPU) stacks, it is essential to gain a holistic understanding from compute kernels, models, and frameworks of popular DL stacks, and to assess their impact on science-driven, mission-critical applications. At Oak Ridge Leadership Computing Facility (OLCF), we employ a set of micro and macro DL benchmarks established through the Collaboration of Oak Ridge, Argonne, and Livermore (CORAL) to evaluate the AI readiness of our next-generation supercomputers. In this paper, we present our early observations and performance benchmark comparisons between the Nvidia V100 based Summit system with its CUDA stack and an AMD MI100 based testbed system with its ROCm stack. We take a layered perspective on DL benchmarking and point to opportunities for future optimizations in the technologies that we consider.

Yin, Junqi↗

Digital in-line holography of dusty plasmas

A digital in-line holography (DIH) approach for the instantaneous measurement of the three-dimensional positions of micrometer sized particles in a radio frequency gas discharge is presented. The applicability of this method to a strongly coupled dusty plasma is demonstrated. The performance of DIH is benchmarked and special attention is paid to its spatial and temporal resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the adiabatic representation of Meyer-Miller electronic-nuclear dynamics

The Meyer-Miller (MM) classical vibronic (electronic + nuclear) Hamiltonian for electronically non-adiabatic dynamics—as used, for example, with the recently developed symmetrical quasiclassical (SQC) windowing model—can be written in either a diabatic or an adiabatic representation of the electronic degrees of freedom, the two being a canonical transformation of each other, thus giving the same dynamics. Although most recent applications of this SQC/MM approach have been carried out in the diabatic representation—because most of the benchmark model problems that have exact quantum results available for comparison are typically defined in a diabatic representation—it will typically be much more convenient to work in the adiabatic representation, e.g., when using Born-Oppenheimer potential energy surfaces (PESs) and derivative couplings that come from electronic structure calculations. The canonical equations of motion (EOMs) (i.e., Hamilton’s equations) that come from the adiabatic MM Hamiltonian, however, in addition to the common first-derivative couplings, also involve second-derivative non-adiabatic coupling terms (as does the quantum Schrödinger equation), and the latter are considerably more difficult to calculate. This paper thus revisits the adiabatic version of the MM Hamiltonian and describes a modification of the classical adiabatic EOMs that are entirely equivalent to Hamilton’s equations but that do not involve the second-derivative couplings. The second-derivative coupling terms have not been neglected; they simply do not appear in these modified adiabatic EOMs. This means that SQC/MM calculations can be carried out in the adiabatic representation, without approximation, needing only the PESs and the first-derivative coupling elements. Here, the results of example SQC/MM calculations are presented, which illustrate this point, and also the fact that simply neglecting the second-derivative couplings in Hamilton’s equations (and presumably also in the Schrödinger equation) can cause very significant errors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerated kinetic Monte Carlo: A case study; vacancy and dumbbell interstitial diffusion traps in concentrated solid solution alloys

Vacancy and self-interstitial atomic diffusion coefficients in concentrated solid solution alloys can have a non-monotonic concentration dependence. Here, the kinetics of monovacancies and $\langle$100$\rangle$ dumbbell interstitials in Ni–Fe alloys are assessed using lattice kinetic Monte Carlo (kMC). The non-monotonicity is associated with superbasins, which impels using accelerated kMC methods. Detailed implementation prescriptions for first passage time analysis kMC (FPTA-kMC), mean rate method kMC (MRM-kMC), and accelerated superbasin kMC (AS-kMC) are given. The accelerated methods are benchmarked in the context of diffusion coefficient calculations. The benchmarks indicate that MRM-kMC underestimates diffusion coefficients, while AS-kMC overestimates them. In this application, MRM-kMC and AS-kMC are computationally more efficient than the more accurate FPTA-kMC. Our calculations indicate that composition dependence of migration energies is at the origin of the vacancy’s non-monotonic behavior. In contrast, the difference between formation energies of Ni–Ni, Ni–Fe, and Fe–Fe dumbbell interstitials is at the origin of their non-monotonic diffusion behavior. Additionally, the migration barrier crossover composition—based on the situation where Ni or Fe atom jumps have lower energy barrier than the other one—is introduced. KMC simulations indicate that the interplay between composition dependent crossover of migration energy and geometrical site percolation explains the non-monotonic concentration-dependence of atomic diffusion coefficients.

36 MATERIALS SCIENCE↗

A parallel, distributed memory implementation of the adaptive sampling configuration interaction method

The many-body simulation of quantum systems is an active field of research that involves several different methods targeting various computing platforms. Many methods commonly employed, particularly coupled cluster methods, have been adapted to leverage the latest advances in modern high-performance computing. Selected configuration interaction (sCI) methods have seen extensive usage and development in recent years. However, the development of sCI methods targeting massively parallel resources has been explored only in a few research works. Here, we present a parallel, distributed memory implementation of the adaptive sampling configuration interaction approach (ASCI) for sCI. In particular, we will address the key concerns pertaining to the parallelization of the determinant search and selection, Hamiltonian formation, and the variational eigenvalue calculation for the ASCI method. Load balancing in the search step is achieved through the application of memory-efficient determinant constraints originally developed for the ASCI-PT2 method. The presented benchmarks demonstrate near optimal speedup for ASCI calculations of Cr 2 (24e, 30o) with 10 6 , 10 7 , and 3 × 10 8 variational determinants on up to 16 384 CPUs. Importantly, to the best of the authors’ knowledge, this is the largest variational ASCI calculation to date.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-F-201-00: Practical Guidelines for Commissioning Advanced Brachytherapy Dose Calculation Algorithms

With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of the clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-F-201-01: Identify Key Clinical Applications Needing Advanced Dose Calculation in Brachytherapy

With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of the clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-F-201-03: Evaluate Clinical Cases Using Commercially Available Systems and Compare to TG-43 Dosimetry

With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of the clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.

60 APPLIED LIFE SCIENCES↗

Commercial Building Energy Saver, API (CBES API) v2.0

The CBES API provides Application Programming Interface to a suite of functions to improve energy efficiency of buildings, including building energy benchmarking, preliminary retrofit analysis using a pre-simulation database DEEP, and detailed retrofit analysis using energy modeling with the EnergyPlus simulation engine. New capabilities in version 2.0 include renewable technologies (PV, storage), advanced HVAC systems, demand response measures, TDV (Time Dependent Valuation energy) metrics, as well as shading from adjacent buildings, trees or roof obstructions. The CBES API is used to power the LBNL CBES Web App. It can be used by third party developers and vendors.

Hong, Tianzhen↗

Analysis of SCALE Criticality and Sensitivity Calculations for Reflected HEU Cylinders

The SCALE code package offers multiple nuclear data libraries and sensitivity and uncertainty (S/U) methods supporting and derived from Monte Carlo (MC) transport. The CSAS and TSUNAMI-3D sequences use KENO MC, utilizing either continuous-energy (CE) cross sections or multigroup (MG) cross section libraries. TSUNAMI-3D has two CE calculational methods: the iterated fission probability (IFP) method, and the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method. Previous work has shown poor agreement between CLUTCH and confirmatory direct perturbation calculations in specific applications (e.g., fissionable and polyethylene reflectors). The HEU-MET-FAST-084 (HMF-084) International Criticality Safety Benchmark Evaluation Project evaluation consists of 27 cylindrical highly enriched uranium metal cores with 14 unique reflector materials of 0.5 and 1 in. thicknesses. Included in this list of reflector materials are natural uranium and polyethylene. This work utilized SCALE 6.2.4 models of the HMF-084 evaluation, with additional non-physical configurations to test both the MG bias and CLUTCH functionality across a variety of reflector material thicknesses. The evaluation’s use of concentric cylinders allowed for examination of several MG self-shielding methods: infinite homogenous, cylindrical, and spherical. The results indicate that the use of polyethylene reflectors with CLUTCH is not fundamentally impossible but sensitive to geometry. The poor performance of CLUTCH with fissionable reflectors was reaffirmed. The 2 in. and greater polyethylene-reflected calculations demonstrate the necessity of using the 302-group library for fast systems. The nickel MG bias was substantial, as discussed in a companion paper, as were cobalt and iron.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantum Monte Carlo Endstation for Petascale Computing

The major achievements enabled by QMC Endstation grant include * Performance improvement on clusters of x86 multi-core systems, especially on Cray XT systems * New and improved methods for the wavefunction optimizations * New forms of trial wavefunctions * Implementation of the full application on NVIDIA GPUs using CUDA The scaling studies of QMCPACK on large-scale systems show excellent parallel efficiency up to 216K cores on Jaguarpf (Cray XT5). The GPU implementation shows speedups of 10-15x over the CPU implementation on older generation of x86. We have implemented hybrid OpenMP/MPI scheme in QMC to take advantage of multi-core shared memory processors of petascale systems. Our hybrid scheme has several advantages over the standard MPI-only scheme. * Memory optimized: large read-only data to store one-body orbitals and other shared properties to represent the trial wave function and many-body Hamiltonian can be shared among threads, which reduces the memory footprint of a large-scale problem. * Cache optimized: the data associated with an active Walker are in cache during the compute-intensive drift-diffusion process and the operations on an Walker are optimized for cache reuse. Thread-local objects are used to ensure the data affinity to a thread. * Load balanced: Walkers in an ensemble are evenly distributed among threads and MPI tasks. The two-level parallelism reduces the population imbalance among MPI tasks and reduces the number of point-to-point communications of large messages (serialized objects) for the Walker exchange. * Communication optimized: the communication overhead, especially for the collective operations necessary to determine ET and measure the properties of an ensemble, is significantly lowered by using less MPI tasks. The multiple forms of parallelism afforded by QMC algorithms make them ideal candidates for acceleration in the many-core paradigm. We presented the results of our effort to port the QMCPACK simulation code to the NVIDIA CUDA GPU platform. We restructured the CPU algorithms to express additional parallelism, minimize GPU-CPU communication, and efficiently utilize the GPU memory hierarchy. Using mixed precision on GT200 GPUs and MPI for intercommunication and load balancing, we observe typical full-application speedups of approximately 10x to 15x relative to quad-core Xeon CPUs alone, while reproducing the double-precision CPU results within statistical error. We developed an all-electron quantum Monte Carlo (QMC) method for solids that does not rely on pseudopotentials, and used it to construct a primary ultra-high-pressure calibration based on the equation of state of cubic boron nitride. We computed the static contribution to the free energy with the QMC method and obtained the phonon contribution from density functional theory, yielding a high-accuracy calibration up to 900 GPa usable directly in experiment. We computed the anharmonic Raman frequency shift with QMC simulations as a function of pressure and temperature, allowing optical pressure calibration. In contrast to present experimental approaches, small systematic errors in the theoretical EOS do not increase with pressure, and no extrapolation is needed. This all-electron method is applicable to first-row solids, providing a new reference for ab initio calculations of solids and benchmarks for pseudopotential accuracy. We compared experimental and theoretical results on the momentum distribution and the quasiparticle renormalization factor in sodium. From an x-ray Compton-profile measurement of the valence-electron momentum density, we derived its discontinuity at the Fermi wavevector finding an accurate measure of the renormalization factor that we compared with quantum-Monte-Carlo and G0W0 calculations performed both on crystalline sodium and on the homogeneous electron gas. Our calculated results are in good agreement with the experiment. We have been studying the heat of formation for various Kubas complexes of molecular hydrogen on Ti(1,2)ethylene-nH2 using Diffusion Monte Carlo. This work has been started and is ongoing. We are studying systems involving 1 and 2 Ti bonding sites with up to 10 hydrogen molecules in numerous configurations. This work will establish a benchmark that will test the accuracy of density functional calculations and establish the feasibility of our methods for similar systems.

97 MATHEMATICS AND COMPUTING↗