Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

A coupled ground heat flux–surface energy balance model of evaporation using thermal remote sensing observations

Abstract. One of the major undetermined problems in evaporation (ET) retrieval using thermal infrared remote sensing is the lack of a physically based ground heat flux (G) model and its integration within the surface energy balance (SEB) equation. Here, we present a novel approach based on coupling a thermal inertia (TI)-based mechanistic G model with an analytical surface energy balance model, Surface Temperature Initiated Closure (STIC, version STIC1.2). The coupled model is named STIC-TI. The model is driven by noon–night (13:30 and 01:30 local time) land surface temperature, surface albedo, and a vegetation index from MODIS Aqua in conjunction with a clear-sky net radiation sub-model and ancillary meteorological information. SEB flux estimates from STIC-TI were evaluated with respect to the in situ fluxes from eddy covariance measurements in diverse ecosystems of contrasting aridity in both the Northern Hemisphere and Southern Hemisphere. Sensitivity analysis revealed substantial sensitivity of STIC-TI-derived fluxes due to the land surface temperature uncertainty. An evaluation of noontime G (Gi) estimates showed 12 %–21 % error across six flux tower sites, and a comparison between STIC-TI versus empirical G models also revealed the substantially better performance of the former. While the instantaneous noontime net radiation (RNi) and latent heat flux (LEi) were overestimated (15 % and 25 %), sensible heat flux (Hi) was underestimated (22 %). Overestimation (underestimation) of LEi (Hi) was associated with the overestimation of net available energy (RNi−Gi) and use of unclosed surface energy balance flux measurements in LEi (Hi) validation. The mean percent deviations in Gi and Hi estimates were found to be strongly correlated with satellite day–night view angle difference in parabolic and linear pattern, and a relatively weak correlation was found between day–night view angle difference versus LEi deviation. Findings from this parameter-sparse coupled G–ET model can make a valuable contribution to mapping and monitoring the spatiotemporal variability of ecosystem water stress and evaporation using noon–night thermal infrared observations from future Earth observation satellite missions such as TRISHNA, LSTM, and SBG.

Bhattacharya, Bimal K.↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, a LIBS system was designed and assembled at NASA Langley Research Center (LaRC) to enable detection of ultralow concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization of CFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is also presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity.

Surface characterization, Carbon fiber reinforced ↗

Probing biolabels for high throughput biosensing via synchrotron radiation SEIRA technique

Bio-diagnostic assays of high complexity rely on nanoscaled assay recognition elements that can provide unique selectivity and design-enhanced sensitivity features. High throughput performance requires the simultaneous detection of various analytes combined with appropriate bioassay components. Nanoparticle induced sensitivity enhancement, and subsequent multiplexed capability Surface-Enhanced InfraRed Absorption (SEIRA) assay formats are fitting well these purposes. SEIRA constitutes an ideal platform to isolate the vibrational signatures of targeted bioassay and active molecules. The potential of several targeted biolabels, here fluorophore-labeled antibody conjugates, chemisorbed onto low-cost biocompatible gold nano-aggregates substrates have been explored for their use in assay platforms. Dried films were analyzed by synchrotron radiation based FTIR/SEIRA spectro-microscopy and the resulting complex hyperspectral datasets were submitted to automated statistical analysis, namely Principal Components Analysis (PCA). The relationships between molecular fingerprints were put in evidence to highlight their spectral discrimination capabilities. We demonstrate that robust spectral encoding via SEIRA fingerprints opens up new opportunities for fast, reliable and multiplexed high-end screening not only in biodiagnostics but also in vitro biochemical imaging.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Millimeter-Wave Thermal Analysis Development and Application to GEN IV Reactor Materials

New millimeter-wave thermal analysis instrumentation has been developed and studied for characterization of materials required for diverse fuel and structural needs in high temperature reactor environments such as the Next Generation Nuclear Plant (NGNP). A two-receiver 137 GHz system with orthogonal polarizations for anisotropic resolution of material properties has been implemented at MIT. The system was tested with graphite and silicon carbide specimens at temperatures up to 1300 ºC inside an electric furnace. The analytic and hardware basis for active millimeter-wave radiometry of reactor materials at high temperature has been established. Real-time, non contact measurement sensitivity to anisotropic surface emissivity and submillimeter surface displacement was demonstrated. The 137 GHz emissivity of reactor grade graphite (NBG17) from SGL Group was found to be low, ~ 5 %, in the 500 – 1200 °C range and increases by a factor of 2 to 4 with small linear grooves simulating fracturing. The low graphite emissivity would make millimeter-wave active radiometry a sensitive diagnostic of graphite changes due to environmentally induced stress fracturing, swelling, or corrosion. The silicon carbide tested from Ortek, Inc. was found to have a much higher emissivity at 137 GHz of ~90% Thin coatings of silicon carbide on reactor grade graphite supplied by SGL Group were found to be mostly transparent to millimeter-waves, increasing the 137 GHz emissivity of the coated reactor grade graphite to about ~14% at 1250 ºC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A comparison of experimental and theoretical results for leakage, pressure distribution, and rotordynamic coefficients for annular gas seals

The importance of seal behavior in rotordynamics is discussed and current annular seal theory is reviewed. A Nelson's analytical-computational method for determining rotordynamic coefficients for this type of compressible-flow seal is outlined. Various means for the experimental identification of the dynamic coefficients are given, and the method employed at the Texas A and M University (TAMU) test facility is explained. The TAMU test apparatus is described, and the test procedures are discussed. Experimental results, including leakage, entrance-loss coefficients, pressure distributions, and rotordynamic coefficients for a smooth and a honeycomb constant-clearance seal are presented and compared to theoretical results from Nelson's analysis. The results for both seals show little sensitivity to the running speed over the test range. Agreement between test results and theory for leakage through the seal is satisfactory. Test results for direct stiffness show a greater sensitivity to fluid pre-rotation than predicted. Results also indicate that the deliberately roughened surface of the honeycomb seal provides improved stability versus the smooth seal.

Nicks, C. O.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Ligand-Induced Size-Dependent Circular Dichroism in Quantum Dots

Recent experiments have probed the chiral properties of semiconductor nanocrystal (NC) quantum dots (QDs), but understanding the circular dichroism line shape, excitonic features, and chirality induction mechanism remains a challenge. We propose an atomistic pseudopotential method to model chiral ligand passivated QDs, computing circular dichroism (CD) spectra for CdSe QDs (2.6-3.8 nm). We find strong agreement between calculated and measured line shapes, predicting consistent bisignate line shapes with decreasing CD magnitude as size increases. Further, our analysis reveals the origin of bisignate line shapes, arising from nondegenerate excitons with opposing angular momenta. We also explore the impact of chiral ligand orientation on QD surfaces, observing changes in the optical activity magnitude and sign. This orientation sensitivity offers the means to distinguish ordered from disordered ligand configurations, facilitating the study of order-disorder transitions at ligand-QD interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrophoretic concentration of DNA at nanoporous polymer membranes for separations and diagnostics.

We report on the use of thin ({approx}30 micron) photopatterned polymer membranes for on-line preconcentration of single- or double-stranded DNA samples prior to electrophoretic analysis. Shaped UV laser light is used to quickly ({approx}10 seconds) polymerize a highly crosslinked polyacrylamide plug. By applying an electric field across the membrane, DNA from a dilute sample can be concentrated into a narrow zone (<100 micron wide) at the outside edge of the membrane. The field at the membrane can then be reversed, allowing the narrow plug to be cleanly injected into a separation channel filled with a sieving polymer for analysis. Concentration factors >100 are possible, increasing the sensitivity of analysis for dilute samples. We have fabricated both neutral membranes (purely size-based exclusion) as well as anionic membranes (size and charge exclusion), and characterized the rate of preconcentration as well as the efficiency of injection from both types of membrane, for DNA, ranging from a 20 base ssDNA oligonucleotide to >14 kbp dsDNA. We have also investigated the effects of concentration polarization on device performance for the charged membrane. Advantages of the membrane preconcentration approach include the simplicity of device fabrication and operation, and the generic (non-sequence specific) nature of DNA capture, which is useful for complex or poorly characterized samples where a specific capture sequence is not present. The membrane preconcentration approach is well suited to simple single-level etch glass chips, with no need for patterned electrodes, integrated heaters, valves, or other elements requiring more complex chip fabrication. Additionally, the ability to concentrate multiple charged analytes into a narrow zone enables a variety of assay functionalities, including enzyme-based and hybridization-based analyses.

59 BASIC BIOLOGICAL SCIENCES↗

Delta V errors due to attitude correction maneuvers of a spinning spacecraft

A statistical error analysis has been performed to evaluate the change in velocity of a spin stabilized spacecraft due to thruster induced attitude correction maneuvers. Analytical expressions were developed to determine the mean and variance of the velocity in terms of the nominal values and uncertainties of key spacecraft parameters. These parameters include thrust, thruster timing, thruster alignment, plume impingement force and estimated spacecraft mass. Typical values of these parameters and their uncertainties for NASA's Galileo spacecraft were used to evaluate these expressions. The results of the analysis allow the effect of attitude correction maneuvers to be evaluated with respect to the functional requirements on nongravitational acceleration. Other results include the identification of major sources of delta V error and studies of the sensitivity of delta V to variations in the error sources.

Zipursky, H. J.↗

Aeroelastic response of metallic and composite propfan models in yawed flow

An analytical investigation of aeroelastic response of metallic and composite propfan models in yawed flow was performed. The analytical model is based on the normal modes of a rotating blade and the three dimensional unsteady lifting surface aerodynamic theory including blade mistuning. The calculated blade stresses or strains are compared with published wind tunnel data on two metallic and three composite propfan wind tunnel models. The comparison shows a good agreement between theory and experiment. Additional parametric results indicate that blade response is very sensitive to the blade stiffness and also to blade frequency and mode shape mistuning. From these findings, it is concluded that both frequency and mode shape mistuning should be included in aeroelastic response analysis. Furthermore, both calculated and measured strains show that combined blade frequency and mode shape mistuning has beneficial effects on response due to yawed flow.

Kaza, Krishna Rao V.↗

Design and analysis of photonic crystal micro-cavity based optical sensor platform

In this paper, the design of a two-dimensional photonic crystal micro-cavity based integrated-optic sensor platform is proposed. The behaviour of designed cavity is analyzed using two-dimensional Finite Difference Time Domain (FDTD) method. The structure is designed by deliberately inserting some defects in a photonic crystal waveguide structure. Proposed structure shows a quality factor (Q) of about 1e5 and the average sensitivity of 500nm/RIU in the wavelength range of 1450 – 1580 nm. Sensing technique is based on the detection of shift in upper-edge cut-off wavelength for a reference signal strength of –10 dB in accordance with the change in refractive index of analyte.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity/Uncertainty Analysis for Nuclear Criticality Safety Validation [Slides]

Sensitivity coefficients predict the expected change in a response ($\kappa$) due to a change in some input parameter ($\Sigma$). These responses can be k eff (or ratios of reaction rates). These input parameters are typically nuclear data. The coefficients are dimensionless ratios. What would happen to the system k eff if some piece of data were changed by some amount? The coefficient is calculated without making the change.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lunar Neutral Exposphere Properties from Pickup Ion Analysis

Composition and structure of neutral constituents in the lunar exosphere can be determined through measurements of phase space distributions of pickup ions borne from the exosphere [1]. An essential point made in an early study [ 1 ] and inferred by recent pickup ion measurements [2, 3] is that much lower neutral exosphere densities can be derived from ion mass spectrometer measurements of pickup ions than can be determined by conventional neutral mass spectrometers or remote sensing instruments. One approach for deriving properties of neutral exospheric source gasses is to first compare observed ion spectra with pickup ion model phase space distributions. Neutral exosphere properties are then inferred by adjusting exosphere model parameters to obtain the best fit between the resulting model pickup ion distributions and the observed ion spectra. Adopting this path, we obtain ion distributions from a new general pickup ion model, an extension of a simpler analytic description obtained from the Vlasov equation with an ion source [4]. In turn, the ion source is formed from a three-dimensional exospheric density distribution, which can range from the classical Chamberlain type distribution to one with variable exobase temperatures and nonthermal constituents as well as those empirically derived. The initial stage of this approach uses the Moon's known neutral He and Na exospheres to deriv e He+ and Na+ pickup ion exospheres, including their phase space distributions, densities and fluxes. The neutral exospheres used are those based on existing models and remote sensing studies. As mentioned, future ion measurements can be used to constrain the pickup ion model and subsequently improve the neutral exosphere descriptions. The pickup ion model is also used to estimate the exosphere sources of recently observed pickup ions on KAGUYA [3]. Future missions carrying ion spectrometers (e.g., ARTEMIS) will be able to study the lunar neutral exosphere with great sensitivity, yielding the necessary ion velocity spectra needed to further analysis of parent neutral exosphere properties.

Hartle, R. E.↗

System and method for high precision isotope ratio destructive analysis

A system and process are disclosed that provide high accuracy and high precision destructive analysis measurements for isotope ratio determination of relative isotope abundance distributions in liquids, solids, and particulate samples. The invention utilizes a collinear probe beam to interrogate a laser ablated plume. This invention provides enhanced single-shot detection sensitivity approaching the femtogram range, and isotope ratios that can be determined at approximately 1% or better precision and accuracy (relative standard deviation).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical model of dielectrophoretic water vapor condensation during multiphase flow of electrically charged water droplets in air

Water droplet growth in air, influenced by vapor diffusion and electrical charging, has significant implications for indoor air quality, cloud formation, and aerosol dynamics. Here, this study presents a comprehensive theoretical model that describes the growth dynamics of electrically charged water droplets under external electric fields, incorporating diffusion, electrostatic, and dielectrophoretic forces to enhance understanding and practical applications in air dehumidification and environmental control. A theoretical model was established to analyze the growth dynamics of the charged water droplets. The approach extended the thermodynamic framework of the Modified Kelvin-Thomson equation by integrating electrostatic and dielectrophoretic effects, enabling a comprehensive evaluation of vapor concentration near the surface of charged droplets. A sensitivity analysis was performed to assess the roles of droplet size, electric field intensity, surface charge, and vapor concentration on condensation rates. The study progressed beyond the classical diffusion-limited growth of neutral droplets, addressing the behavior of charged droplets in electrohydrodynamic environments. The model highlighted the significance of dielectrophoretic drift flux for dipolar vapor molecules, especially in micron-sized droplets ranging from 10 to 100 µm. Findings demonstrated that, for smaller droplets subjected to elevated electrical charge, average growth rates varied from 0.3 to 1.6 µm/s if the air relative humidity increased from 50 to 100 %. Analytical results are corroborated by numerical simulations, which exhibited strong concordance, thereby validating the proposed theoretical approach. This research introduced an innovative and scalable analytical methodology for electric field-enhanced droplet growth, offering valuable insights into the advancement of energy-efficient air dehumidification, water desalination, and atmospheric water harvesting technologies.

42 ENGINEERING↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (Final Report)

Carbon capture and sequestration (CCS) technologies that can operate with a high degree of operating flexibility could provide necessary electric grid flexibility in a system with high shares of variable renewables. This project examines the deployment and dispatch potential of twelve unique flexible CCS (FLECCS) technologies that encompass post-combustion carbon dioxide (CO 2 ) capture designs, concepts using a storage media to enable energy arbitrage, and hybrid processes that integrate CCS with direct air capture (DAC) for flexibility with net zero or negative CO 2 emissions. FLECCS technology potential is explored with a multi-model, multi-scale framework including the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model (CEM) and the PLEXOS production cost model (PCM). Innovative methods were developed to represent FLECCS technology operating modes, performance, and cost in the two models. ReEDS was then used to simulate nine scenarios for each FLECCS technology, three CO 2 emissions price futures reaching $\$$150, $\$$225, and $\$$300/tCO 2 in 2050; and three scenarios for FLECCS technology deployment favorability relative to competing technologies. For each CO 2 price and reference FLECCS favorability, the 2050 infrastructures from ReEDS model are downscaled and implemented in PLEXOS to examine hourly dispatch under detailed operational constraints that are not included in ReEDS. FLECCS technologies exhibited a wide range of deployment potential ranging from none to several hundred gigawatts of capacity, with outcomes highly sensitive to input cost and performance parameters that are inherently highly uncertain. When deployed, FLECCS tended to displace a combination of wind, solar, and natural gas-based technologies rather than supporting increased renewable deployment. As a result, CO 2 emissions reductions facilitated by FLECCS deployment tended to come with higher overall system costs and electricity prices. When economically competitive, FLECCS technologies can contribute significant flexible generation and firm capacity to the grid, but continued technology development and an expanded analytical scope are necessary to fully understand FLECCS deployment potential its impact on the electric power sector. Follow-on analysis incorporating captured CO 2 tax credit value from the Inflation Reduction Act (IRA) and other potential policy scenarios could be particularly valuable, as this policy can substantially change the relative competitiveness of FLECCS technologies.

03 NATURAL GAS↗