Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗

Phase instability-coupled fracture behavior in garnet LLZO solid electrolytes: a machine learning-enabled atomistic study

Fracture in the garnet-type solid electrolyte Li 7 La 3 Zr 2 O 12 (LLZO) poses a critical threat to both the performance and safety of solid-state batteries. To unravel the coupled chemomechanical processes that govern fracture in LLZO under external loading, we carry out large-scale molecular-dynamics simulations with a validated machine-learning force field. Our results demonstrate that triaxial stresses at crack flanks trigger a localized cubic-to-tetragonal phase transformation, which is accompanied by Li-ion rearrangement. The emergent tetragonal domains feature lattice contraction normal to the fracture plane, imposing coherent misfit strains that provide an additional driving force for further crack propagation. Crucially, introducing Li deficiencies stabilizes the cubic phase, postponing the phase transition and thereby delaying fracture initiation. These findings highlight the role of intrinsic phase instability in dictating LLZO's fracture resistance and its critical connection to local Li concentration. This chemomechanical coupling points toward targeted strategies to enhance the mechanical robustness of garnet electrolytes, including tuning Li content, ensuring dopant homogeneity, and refining processing protocols.

Materials science↗

Physical Property Measurements of Laboratory Prepared Saltstone Grout

The Saltstone Production Facility (SPF) built two new Saltstone Disposal Units (SDU), SDU 3 and SDU 5, in 2013. The variable frequency drive (VFD) for the grout transfer hose pump tripped due to high current demand by the motor during the initial radioactive saltstone transfer to SDU 5B on 12/5/2013. This was not observed during clean cap processing on July 5, 2013 to SDU 3A, which is a slightly longer distance from the SPF than is SDU 5B. Saltstone Design Authority (SDA) is evaluating the grout pump performance and capabilities to transfer the grout processed in SPF to SDU 3/5. To assist in this evaluation, grout physical properties are required. At this time, there are no rheological data from the actual SPF so the properties of laboratory prepared samples using simulated salt solution or Tank 50 salt solution will be measured. The physical properties of grout prepared in the laboratory with de-ionized water (DI) and salt solutions were obtained at 0.60 and 0.59 water to premix (W/P) ratios, respectively. The yield stress of the DI grout was greater than any salt grout. The plastic viscosity of the DI grout was lower than all of the salt grouts (including salt grout with admixture). When these physical data were used to determine the pressure drop and fluid horsepower for steady state conditions, the salt grouts without admixture addition required a higher pressure drop and higher fluid horsepower to transport. When 0.00076 g Daratard 17/g premix was added, both the pressure drop and fluid horsepower were below that of the DI grout. Higher concentrations of Daratard 17 further reduced the pressure drop and fluid horsepower. The uncertainty in the single point Bingham Plastic parameters is + 4% of the reported values and is the bounding uncertainty. Two different mechanical agitator mixing protocols were followed for the simulant salt grout, one having a total mixing time of three minutes and the other having a time of 10 minutes. The Bingham Plastic parameters were essentially the same for the salt grout without admixture. When Daratard 17 was added, the Bingham Plastic yield stress increased for the 10 minute mix. The simulant salt used in this task had similar physical properties of the Tank 50 3Q13 salt grout and is recommended for future use, if the salt solution in Tank 50 does not change. The design basis physical properties used to size the pumps and mixers at SPF were obtained from DPST-85-312. The grouts characterized in this report are bounded by the design basis density and Bingham Plastic yield stress. The opposite is true for the plastic viscosity. Steady state pressure drop calculations were performed for the design basis values using the flow rate for the clean cap and salt grouts and they bound the pressure drop of the grouts characterized in this report. A comparison of the lab prepared samples to PI ProcessBook data, specifically average pressure drop, indicate that the lab prepared samples are more viscous in nature than what is processed in the facility. This difference could be due to the applied shear rates which could be lower in the lab as compared to the facility and that fact the SPF added flush water, making this comparison more difficult. A perfunctory review of the PI ProcessBook data was discussed. It may be possible that the frequency that the distributed control system alters the grout pump speed to maintain grout hopper volume can negatively affect the efficiency of the grout pump.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sequential addition of short DNA oligos in DNA-polymerase-based synthesis reactions

A method of preselecting a multiplicity of DNA sequence segments that will comprise the DNA molecule of user-defined sequence, separating the DNA sequence segments temporally, and combining the multiplicity of DNA sequence segments with at least one polymerase enzyme wherein the multiplicity of DNA sequence segments join to produce the DNA molecule of user-defined sequence. Sequence segments may be of length n, where n is an odd integer. In one embodiment the length of desired hybridizing overlap is specified by the user and the sequences and the protocol for combining them are guided by computational (bioinformatics) predictions. In one embodiment sequence segments are combined from multiple reading frames to span the same region of a sequence, so that multiple desired hybridizations may occur with different overlap lengths.

59 BASIC BIOLOGICAL SCIENCES↗

Inventing an Energy Internet: Concepts, Architectures and Protocols for Smart Energy Utilization

In recent years, the Internet is revolutionizing information availability much like the Power Grid revolutionized energy availability a century earlier. We will explore the differences and similarities of these two critical infrastructures and identify ways for convergence which may lead to an energy internet. Pricing signals, nodal forecasting, and short-term elasticities are key concepts in smart energy flows respecting the delicate equilibrium involved in generation-demand and aiming at higher efficiencies. We will discuss how intelligent forecasting approaches operating at multiple levels (including device or nodal levels) can ameliorate the challenges of power storage. In addition to higher efficiencies, an energy internet may achieve significant reliability and security improvements and offer greater flexibility and transparency in the overall energy-environmental relation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ambient Ionization Mass Spectrometry Measurement of Aminotransferase Activity

A change in enzyme activity has been used as a clinical biomarker for diagnosis and is useful in evaluating patient prognosis. Current laboratory measurements of enzyme activity involve multi-step derivatization of the reaction products followed by quantitative analysis of these derivatives. This study simplified the reaction systems by using only the target enzymatic reaction and directly detecting its product. A protocol using paper spray mass spectrometry for identifying and quantifying the reaction product has been developed. Evaluation of the activity of aspartate aminotransferase (AST) was chosen as a proof-of-principle. The volume of sample needed is greatly reduced compared with the traditional method. Paper spray has a desalting effect that avoids sprayer clogging problems seen when examining serum samples by nanoESI. This very simple method does not require sample pretreatment and additional derivatization reactions, yet it gives high quality kinetic data, excellent limits of detection (60 ppb from serum), and coefficients of variation <10% in quantitation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron Neutron Capture Therapty (BNCT) in an Oral Precancer Model: Therapeutic Benefits and Potential Toxicity of a Double Application of BNCT with a Six-Week Interval

Given the clinical relevance of locoregional recurrences in head and neck cancer, we developed a novel experimental model of premalignant tissue in the hamster cheek pouch for long-term studies and demonstrated the partial inhibitory effect of a single application of Boron Neutron Capture Therapy (BNCT) on tumor development from premalignant tissue. The aim of the present study was to evaluate the effect of a double application of BNCT with a 6 week interval in terms of inhibitory effect on tumor development, toxicity and DNA synthesis. We performed a double application, 6 weeks apart, of (1) BNCT mediated by boronophenylalanine (BPA-BNCT); (2) BNCT mediated by the combined application of decahydrodecaborate (GB-10) and BPA [(GB-10 + BPA)-BNCT] or (3) beam-only, at RA-3 nuclear reactor and followed the animals for 8 months. The control group was cancerized and sham-irradiated. BPA-BNCT, (GB- 10 + BPA)-BNCT and beam-only induced a reduction in tumor development from premalignant tissue that persisted until 8, 3, and 2 months respectively. An early maximum inhibition of 100% was observed for all 3 protocols. No normal tissue radiotoxicity was detected. Reversible mucositis was observed in premalignant tissue, peaking at 1 week and resolving by the third week after each irradiation. Mucositis after the second application was not exacerbated by the first application. DNA synthesis was significantly reduced in premalignant tissue 8 months post-BNCT. A double application of BPA-BNCT and (GB-10 + BPA)-BNCT, 6 weeks apart, could be used therapeutically at no additional cost in terms of radiotoxicity in normal and dose-limiting tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pressure-Dependent Phase Behavior of Chemically Synthesized Ytterbium Hydride Nanoparticles and Confinement in CMK-3

In this work, we developed a chemical synthesis protocol to prepare both spherical and rod shaped YbH x nanoparticles and infiltrate a mesoporous CMK-3 structure with YbH x nanoparticles. The phase evolution of the YbH x nanoparticles was monitored as a function of the pressure in a diamond anvil cell. The cell volume of the Yb atom showed an unexpected positive deviation from the calculated equation of state (EoS) for the α-phase (space group Pnma) of YbH x . Additionally, the β-phase (space group Fm3̅m) YbH x nanoparticles appeared to become amorphous at approximately 27 GPa, although the same behavior was not observed in the Pnma (α-phase). The Pmna phase remained stable (measured up to 59.3 GPa) and showed a significantly higher than expected volume per Yb atom relative to the calculated EoS. This deviation could be attributed to the nanoscale effect on the thermodynamics of ytterbium hydride formation, which could provide a path forward to accessing higher order ytterbium hydrides (YbH x , x > 3) at pressures much lower than in the bulk metal.

diamond anvil cell↗

Photoinduced Magnetic Exchange-Jump Promotes Ground State Biradical Electron Spin Polarization

Photoinduced electron spin polarization (ESP) is reported in the electronic ground states of three Pt(II) complexes that are comprised of two S = ½ nitronyl nitroxide (NN) radicals attached through different length para-phenylethynyl bridges to the 3,6 positions of a catecholate (CAT, donor) and 4,4’-di-tert-butyl-2,2’-bipyridine (bpy, acceptor). Complexes 1-3 have from 17 to 41 bonds separating NN radicals, and display cw-EPR spectra consistent with |J NN-NN | >> |a N |, |J NN-NN | ≥ |a N |, and |J NN-NN | < |a N |, respectively, where J NN-NN is the magnetic exchange coupling between NN radicals in the electronic ground state, and a N is the isotropic 14 N hyperfine coupling constant. Light-induced transient EPR spectra characterized as enhanced ground-state absorption were observed for all three complexes using 532 nm pulsed laser excitation into the ligand-to-ligand charge transfer (LL’CT) band of the (CAT)Pt(bpy) chromophore. The magnitude of the observed ESP increases in the order 1 < 2 < 3 and is inversely correlated with the magnitude of ground-state J NN-NN . In addition to the experimental observation net absorptive polarization in 1-3, light excitation also produces multiplet polarization in 2. Since the weak dipolar coupling leads to strong spectral overlap of the absorptive and emissive components, the multiplet polarization is not observed in 1 and 3 and is very weak in 2. Here, the ability to spin polarize multiple radical spins with a single photon is anticipated to advance new photoinduced multi qubit/qudit ESP protocols for quantum information science applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overlooked branch turnover creates a widespread bias in forest carbon accounting

Most measurements and models of forest carbon cycling neglect the carbon flux associated with the turnover of branch biomass, a physiological process quantified for other organs (fine roots, leaves, and stems). Synthesizing data from boreal, temperate, and tropical forests (184,815 trees), we found that including branch turnover increased empirical estimates of aboveground wood production by 16% (equivalent to 1.9 Pg Cy −1 globally), of similar magnitude to the observed global forest carbon sinks. In addition, reallocating carbon to branch turnover in model simulations reduced stem wood biomass, a long-lasting carbon storage, by 7 to 17%. This prevailing neglect of branch turnover suggests widespread biases in carbon flux estimates across global datasets and model simulations. Branch litterfall, sometimes used as a proxy for branch turnover, ignores carbon lost from attached dead branches, underestimating branch C turnover by 38% in a pine forest. Modifications to field measurement protocols and existing models are needed to allow a more realistic partitioning of wood production and forest carbon storage.

Lim, Hyungwoo↗

MO-DE-210-04: Repositioning and Monitoring of Prostate Cancer Radiotherapy with a New 4D Ultrasound Intra-Modality IGRT Device

Purpose: We report our clinical experience using a non-invasive transperineal (TP) ultrasound (US) probe dedicated to pre-positioning and monitoring of prostate cancer patients. The accuracy of pre-treatment positioning was compared to CBCT for prostate and post-prostatectomy patients. Intrafraction motions were recorded for both localizations. The dosimetric impact of these displacements was finally investigated on prostate patients. Methods: Differences between CBCT/CT and TP-US/TP-US registrations were analyzed on 427 and 453 sessions for 13 prostate and 14 post-prostatectomy patients, respectively. Ten prostate patients’ dosimetries were retrospectively planned using 2 different protocols: 80Gy in 40 fractions and 36.25Gy in 5 fractions with a 5mm CTV- to- PTV margin. The delivery time was measured in order to analyze ranges of intrafraction motions related to each protocol. Mean prostate displacements were calculated for each patient and applied to the treatment isocenter coordinates to evaluate the dosimetric impact of these motions. Results: CBCT and TP-US shifts agreements at ±5mm were 76.6%, 95.1%, 96.3% and 90.3%, 85.0%, 97.6% in anterior- posterior, superior- inferior and left-right directions, for prostate and post-prostatectomy patients, respectively. Intrafraction motions were analyzed considering delivery times of 140 and 290s with an additional time of 120s for patient installation for doses of 2 and 7.25Gy, respectively. Intrafraction motions were patient-dependent and were larger as the irradiation time increased. Larger displacements were observed for prostate compared to post-prostatectomy localizations. Shifts above 3mm were observed on 17.6% and 4.5% of the 2Gy sessions against 30.6% and 7.3% of the 7.25Gy sessions in the anterior-posterior direction for prostate and post-prostatectomy localizations, respectively. Preliminary dosimetric results showed that intrafraction motions mainly impact the PTV coverage. Conclusion: 4D TP-US modality is a promising alternative to irradiating and/or invasive IGRT modalities for both inter and intrafraction motions management. Preliminary dosimetric results show that intrafraction monitoring is mandatory especially for hypofractionated treatments. M Fargier-Voiron was supported by a PhD grant from Elekta.

60 APPLIED LIFE SCIENCES↗

Recommendations for Minimum Required Diagnostics Information

The rapid growth of electrified transportation, including light- and medium-duty electric vehicles (EVs) as a mobility solution requires a reliable EV-charging infrastructure. To advance charging reliability, the ChargeX Consortium reports “Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure” and “Implementation Guide for Minimum Required Error Codes in Electric Vehicle Charging Infrastructure” provided recommendations for a set of minimum required error codes (MRECs), their functional and responsibility classifications, and a guide for their implementation, using Open Charge Point Protocol (OCPP) versions 1.6J4 and 2.0.1.5 These reports outline a recommended practice for consistent error reporting and interpretation, which is essential for communicating issues uniformly across the complex and diverse EV-charging ecosystem. However, MRECs are just one part of diagnosing issues; another critical part is obtaining enough information about the current state and performance of the various charging components to identify root causes for each of the error codes. This additional diagnostics data can be used by technicians or automated systems to understand the context around an issue, allowing for timely resolution, decreased maintenance costs, and increased charging reliability. During everyday operations, data are regularly collected and analyzed across the ecosystem. Although sharing of all that available data would be great for diagnostics, concerns on data ownership, privacy, and original equipment manufacturer (OEM) intellectual property pose a challenge. To overcome this obstacle, this report proposes a set of minimum required diagnostic information (MRDI) and recommends that the industry implement these uniformly across the North American EV charging ecosystem. MRDI provides a means to exchange only data deemed necessary for root cause determination.

33 ADVANCED PROPULSION SYSTEMS↗

Optimization of La 2–x Sr x CuO 4 Single Crystal Film Growth via Molecular Beam Epitaxy

Atomic layer-by-layer molecular beam epitaxy (ALL-MBE) combined with ozone is one of the best methods to fabricate single-crystal thin films of complex oxides. Cuprate such as La 2-x Sr x CuO 4 (LSCO) is a representative complex-oxide high-temperature superconductor (HTS) material. Our group utilizes this method to produce high-quality single-crystal HTS films with atomically smooth surfaces and interfaces. In addition, ALL-MBE enables us to engineer multilayer heterostructures with atomic precision. This allows the fabrication of tunnel junctions, various nanostructures, and other HTS devices of interest for superconducting electronics. We have synthesized over three thousand LSCO thin films in the past two decades. These films’ structural and electronic properties have been studied and characterized by various methods. Here, we distill the extensive experience we accumulated into a step-by-step protocol to fabricate atomically perfect LSCO films. The recipe includes substrate preparation, ozone generation and distillation, source calibration, the in situ monitoring of the film synthesis, post-growth annealing, and ex situ characterization. It discloses a reproducible way to fabricate single-crystal LSCO films for basic research and HTS electronic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of Surface Nitrides Created During "Doping" Heat Treatments of Niobium

The benefits of reduced RF losses from interstitial "doping" of niobium are well established. Many of the details involved in the process remain yet to be elucidated. The niobium surface reacted with low-pressure nitrogen at 800°C presents a surface with chemical reactivity different than standard niobium. While standard "recipes" are being used to produce cavities, we seek additional insight into the chemical processes that may be used to remove the "undesirable" as-formed surface layer. This may lead to new processing routes or quality assurance methods to build confidence that all surface "nitrides" have been removed. We report a series of alternate chemistry treatments and subsequent morphological examinations and interpret the results. We also introduce a new standardized Nb sample system in use for efficient characterization of varying doping protocols and cross-laboratory calibration.

Spradlin, J. K.↗

Multi-site Milling Strategy Reveals Significant Variation in Biomass Composition of Switchgrass ( Panicum virgatum ) Grown at Ten Locations

Cell wall composition influences biomass use as a forage and as a feedstock for biofuel and chemical conversion. To examine the influence of environment on composition of switchgrass (Panicum virgatum L.), we utilized a multi-environment experiment consisting of clones of switchgrass genotypes grown at up to ten locations in the continental US. We tested the influence of different milling treatments on biomass composition trait predictions via near-infrared reflectance spectroscopy (NIRS). We found that most compositional trait predictions (29/34) were significantly different (P < 0.05) when a single lot of biomass was subjected to disparate milling treatments, i.e., knife milling vs. knife milling with an additional cyclone milling. Further, depending on the plant material tested, three to eight compositional trait predictions vary (P < 0.05) when identical biomass was knife milled at different sites followed by cyclone milling at a single site, including for traits such as Klason lignin, nitrogen, and carbon. In some cases, variation due to milling site exceeded environmentally induced compositional variation of a single switchgrass genotype grown at different sites. From these observations, we recommend a protocol with two sequential millings that decouples growth environment from a particular mill. Utilizing this approach, we found that 46/46 biomass composition traits from the warm season herbaceous forage and switchgrass bioethanol NIRS equations vary significantly (P < 0.001) in clones of a switchgrass genotype (WBC) grown at ten sites, with the growth site representing the largest average source of variation (41%). This multi-site milling approach can be used to examine environmental and gene-by-environment influences on composition with the goal of optimizing cell wall composition in different environments for biomass utilization.

09 BIOMASS FUELS↗

A Lakehouse Architecture for the Management and Analysis of Heterogeneous Data for Biomedical Research and Mega-biobanks

Data Lakehouse is a new paradigm in data architectures that embodies and integrates already established concepts for the systematic management of disparate, large-scale data – a data lake for heterogeneous data management, use of open standards for high-performance querying, and systematic maintenance of the data "freshness". In addition to being a new concept, the data lakehouse is also still a conceptual construct. Many projects that use the lakehouse require maturing, empirical studies, and specific implementations. In this paper, we present our implementation of the data lakehouse concept in a biomedical research and health data analytics domain, and we discuss the implementation of some unique and novel features such as support for specialized access controls in support of HIPAA regulation and IRB protocols, and support for the FAIR standard.

Begoli, Edmon↗

SU-F-J-143: Initial Assessment of Image Quality of An Integrated MR-Linac System with ACR Phantom

Purpose/Objective(s): To assess the image quality of an integrated MR-Linac system and compare with other MRI systems that are primarily used for diagnostic purposes. Materials/Methods: An ACR MRI quality control (QC) phantom was used to evaluate the image quality of a fully integrated 1.5T MRI-Linac system recently installed at our institution. This system has a new split magnet design which gives the magnetic field strength of 1.5T. All images were acquired with a set of phased-array surface coils which are designed to have minimal attention of radiation beam. The anterior coil rests on a coil holder which keeps the anterior coil’s position consistent for QA purposes. The posterior coil is imbedded in the patient couch. Multiple sets of T1, T2/PD images were acquired using the protocols as prescribed by the ACR on three different dates, ranging 3 months apart. Results: The geometric distortion are within 0.5 mm in the axial scans and within 1mm in the saggital (z-direction) scans. Slice thickness accuracy, image uniformity, ghosting ratio, high contrast detectability are comparable to other 1.5T diagnostic MRI scanners. The low-contrast object detectability are lower comparatively, which is a result of using the body array coil. Additionally, the beam’s-eye-view images (oblique coronal and saggital images) have minimal geometric distortion at all linac gantry angles tested. No observable changes or drift in image quality is found from images acquired 3 month apart. Conclusion: Despite the use of a body array surface coil, the image quality is comparable to that of an 1.5T MRI scanner and is of sufficient quality to pass the ACR MRI accreditation program. The geometric distortion of the MRI system of the integrated MR-Linac is within 1mm for an object size similar to the ACR phantom, sufficient for radiation therapy treatment purpose. The authors received corporate sponsored research grants from Elekta which is the vendor for the MR-Linac evaluated in this study.

60 APPLIED LIFE SCIENCES↗