Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Delta modulation

The conclusions of the design research of the song adaptive delta modulator are presented for source encoding voice signals. The variation of output SNR vs input signal power/when 8, 9, and 10 bit internal arithmetic is employed. Voice intelligibility tapes to test the 10-bit system are used. An analysis of a delta modulator is also presented designed to minimize the in-band rms error. This is accomplished by frequency shaping the error signal in the modulator prior to hard limiting. The result is a significant increase in the output SNR measured after low pass filtering.

Schilling, D. L.↗

Sky-Scanning Sun-Tracking Airborne Radiometer (3STAR): Instrument Design, Flight Testing, and Tracking Performance

The Sky-Scanning, Sun-Tracking Airborne Radiometer (3STAR) adapts commercial radiometer technology developed for the ocean color research community to airborne measurement of spectrally resolved solar irradiance and sky radiance. These atmospheric observations are used to derive aerosol optical depth (AOD), supporting localized AOD inputs for atmospheric correction of satellite and airborne data over terrestrial and aquatic (including optically dark) targets. The ability to regionally “tune” atmospheric correction schemes with relevant spatial AOD supports constraining atmospheric correction of remote sensing reflectance. Very wide dynamic range has been achieved for multi-channel band-pass-filter-radiometers originally designed for deployment into the water column. By actively tracking and directly pointing to the Sun, the light attenuation by aerosol particles in the atmospheric column can be quantified. These measurements improve knowledge of atmospheric constituents and the atmospheric corrections required to improve remote sensing capabilities for interpreting reflectance measurements from the Earth surface. 3STAR incorporates a custom Sun-tracking/sky-scanning pointing head, a Sun-tracking camera, and a commercially available, cylindrical, 19-channel radiometer tube assembly. An accurate and responsive mount and tracking system has been developed and certified to NASA and Naval Air Systems Command (NAVAIR) airworthiness standards for deployment into the aircraft slipstream. Ground and flight testing indicate typical tracking errors of less than 0.1 degrees, well within the field of view of the radiometer as required to minimize measurement uncertainty from alignment error. Preliminary AOD measurements compare to within 0.013 with 15 measurements from an Aerosol Robotic Network (AERONET) Cimel instrument at 500 nm wavelength and low solar angle.

Atmosphere↗

Implementation of Talbot–Lau x-ray deflectometry in the pulsed power environment using a copper X-pinch backlighter

A Talbot–Lau x-ray deflectometer can map electron density gradients in high energy density plasmas, as well as provide information about plasma elemental composition through single-image x-ray refraction and attenuation measurements. A new adaptation to a pulsed power environment used backlighting from copper X-pinches, allowing for electron density mapping of a low-Z object. Even though the X-pinch backlighter is not properly optimized for emitting x-rays in terms of source size and photon fluence, Moire fringe patterns with contrast up to 14% and fringe shift due to refraction on a beryllium object are obtained. Due to the proximity of the deflectometer with the X-pinch (~6 cm), it is shown that a protective filter is required to avoid damage in the closest (i.e., source) grating due to both plasma debris and mechanical shock. Regarding grating survival, these did not show any damage due to the intense magnetic field or heating induced by plasma radiation. Electron density on beryllium was measured with a difference lower than 16%. The areal electron density mapping of the sample was limited by source size characteristics, in similarity to transmission radiography. These results show the potential of plasma electron density as well as material mapping through Talbot–Lau x-ray deflectometry in a pulsed power environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LENS: Learning Enabled Network Synthesis

RTRC and UMD have developed novel machine learning based methods under the ARPA-E DIFFERENTIATE program for rapid acceleration of hypothesis generation in complex architecture design spaces involving both discrete choices of component inclusion and interconnection and continuous parametric decisions. The project named Learning Enabled Network Synthesis (LENS) further demonstrated the developed methods on challenging electrical power converter design problems by identifying the most suitable circuit topologies and simultaneously selecting the most appropriate components to achieve optimized design of power converter with improved performances. We demonstrated that LENS could enable exploration of very large design space of circuit topologies and components by addressing the limitations of conventional design process in non-linear, high switching speed, multi-dimensional power converter design and optimization. The key innovation developed in LENS is the seamless integration of statistical learning and logical reasoning techniques and building on the individual strengths of these techniques for rapid hypothesis discovery. The main component of LENS comprises of: 1) Graph Reasoning Engine (GRE) to enforce composition rules that rapidly reject all discrete architectures that are composed incorrectly and generates an adaptive database of feasible designs which can be used by ML modules, 2) Graph Generative Learning module which is a deep neural network based generative model for graph architectures which can enable design space exploration beyond the dataset generated by the GRE, 3) Graph Reduced Order Model (ROM) for graph domains for accelerating computation of output metrics, and 4) Active learning and Rule Discovery module for sample efficient learning and extracting logical rules from the learned ML models which will be integrated in the GRE to enhance the filtering effectiveness. LENS approach can be applied to any design domains where designs can be represented as multi-attribute graphs. The LENS team integrated the various technical innovations listed above into an optimization pipeline and exercised the optimization pipeline on the converter design problem. The LENS project demonstrated that the developed AI/ML technologies can be used to generate novel converter circuits >45x faster than experts on chosen use-cases. This can enable faster design space exploration and identification of new designs which are not considered by experts due to the increasing design space complexity. This has significant potential impact on the public and energy needs of the country. It is currently estimated that 30% of all electrical powers generated passes through power converters. The future estimate is that 80% of all power generated would be passing through converters. LENS fills a critical gap in this space since by accelerating the design process the designers would be able to generate more efficient converters which can lead to significant energy savings for the country.

42 ENGINEERING↗

NASA Tech Briefs, January 2011

The topics include: 1) Distributed Aerodynamic Sensing and Processing Toolbox; 2) Collaborative Supervised Learning for Sensor Networks; 3) Hazard Detection Software for Lunar Landing; 4) Onboard Nonlinear Engine Sensor and Component Fault Diagnosis and Isolation Scheme; 5) Network-Capable Application Process and Wireless Intelligent Sensors for ISHM; 6) Interface Supports Multiple Broadcast Transceivers for Flight Applications; 7) FPGA Sequencer for Radar Altimeter Applications; 8) Miniature Sapphire Acoustic Resonator - MSAR; 9) Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plume Constituents; 10) SAD5 Stereo Correlation Line-Striping in an FPGA; 11) Hybrid Composite Cryogenic Tank Structure; 12) Nanoscale Deformable Optics; 13) Reliability-Based Design Optimization of a Composite Airframe Component; 14) Zinc Oxide Nanowire Interphase for Enhanced Lightweight Polymer Fiber Composites; 15) Plasma Igniter for Reliable Ignition of Combustion in Rocket Engines; 16) Wire Test Grip Fixture; 17) A Sub-Hertz, Low-Frequency Vibration Isolation Platform; 18) Carbon Nanofibers Synthesized on Selective Substrates for Nonvolatile Memory and 3D Electronics; 19) Nanoparticle/Polymer Nanocomposite Bond Coat or Coating; 20) High-Resolution Wind Measurements for Offshore Wind Energy Development; 21) Spring Tire; 22) Marsviewer 2008; 23) Mission Services Evolution Center Message Bus; 24) Major Constituents Analysis for the Vehicle Cabin Atmosphere Monitor; 25) Astronaut Health Participant Summary Application; 26) Adaption of the AMDIS Method to Flight Status on the VCAM Instrument; 27) Natural Language Interface for Safety Certification of Safety-Critical Software; 28) Cryogenic Caging for Science Instrumentation; 29) Wide-Range Neutron Detector for Space Nuclear Applications; 30) In Situ Guided Wave Structural Health Monitoring System; 31) Multiplexed Energy Coupler for Rotating Equipment; 32) Attitude Estimation in Fractionated Spacecraft Cluster Systems; 33) Full Piezoelectric Multilayer-Stacked Hybrid Actuation/Transduction Systems; 34) Active Flow Effectors for Noise and Separation Control; 35) Method and System for Temporal Filtering in Video Compression Systems; 36) Apparatus for Measuring Total Emissivity of Small, Low-Emissivity Samples; 37) Multiple-Zone Diffractive Optic Element for Laser Ranging Applications; 38) Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver; 39) Two-Photon-Absorption Scheme for Optical Beam Tracking; 40) High-Sensitivity, Broad-Range Vacuum Gauge Using Nanotubes for Micromachined Cavities; 41) Wide-Field Optic for Autonomous Acquisition of Laser Link; 42) Extracting Zero-Gravity Surface Figure of a Mirror; 43) Modeling Electromagnetic Scattering From Complex Inhomogeneous Objects; 44) Visual Object Recognition and Tracking of Tools; 45) Method for Implementing Optical Phase Adjustment; 46) Visual SLAM Using Variance Grid Maps; 47) Rapid Calculation of Spacecraft Trajectories Using Efficient Taylor Series Integration; 48) Efficient Kriging Algorithms; 49) Predicting Spacecraft Trajectories by the WeavEncke Method; 50) An Augmentation of G-Guidance Algorithms; 51) Comparison of Aircraft Icing Growth Assessment Software; 52) Silicon-Germanium Voltage-Controlled Oscillator at 105 GHz; 53) Estimation of Coriolis Force and Torque Acting on Ares-1; 54) Null Lens Assembly for X-Ray Mirror Segments; and 55) High-Precision Pulse Generator.

Source record↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of an L-band Microwave Radiometer with Active Mitigation of Interference

Radio frequency interference (RFI) impairs L-band radiometry outside the protected 20 MHz frequency band around 1413 MHz. However, bandwidths of 100 MHz or more are desired for certain remote sensing applications as well as certain astronomy applications. Because much of the RFI in this band is from radars with pulse lengths on the order of microseconds, traditional radiometers (i.e., those which directly measure total power or power spectral density integrated over time scales of milliseconds or greater) are poorly-suited to this task. Simply reducing integration time and discarding contaminated outputs may not be a practical answer due to the wide variety of modulations and pulse lengths observed in L-band RFI signals, the dynamic and complex nature of the associated propagation channels, and the logistical effort associated with post-measurement data editing. This motivates the design and development of radiometers capable of coherent sampling and adaptive, real-time mitigation of interference. Such a radiometer will be described in this presentation. This design is capable of coherently-sampling up to 100 MHz bandwidth at L-band. RFI mitigation is implemented in FPGA components so that real-time suppression is achieved. The system currently uses a cascade of basic time- and frequency-domain detection and blanking techniques; more advanced algorithms are under consideration. The modular FPGA-based architecture provides other benefits, such as the ability to implement extremely stable digital filters and the ability to reconfigure the system "on the fly". An overview of the basic design along with on-the-air results from an initial implementation will be provided in the presentation. Related L-band RFI surveys will be described to illustrate the relevance of this approach in a variety of operating conditions.

Hampson, G. A.↗

Design of an L-band Microwave Radiometer with Active Mitigation of Interference

Radio frequency interference (RFI) impairs L-band radiometry outside the protected 20 MHz frequency band around 1413 MHz. However, bandwidths of 100 MHz or more are desired for certain remote sensing applications as well as certain astronomy applications. Because much of the RFI in this band is from radars with pulse lengths on the order of microseconds, traditional radiometers (i.e., those which directly measure total power or power spectral density integrated over time scales of milliseconds or greater) are poorly-suited to this task. Simply reducing integration time and discarding contaminated outputs may not be a practical answer due to the wide variety of modulations and pulse lengths observed in L-band RFI signals, the dynamic and complex nature of the associated propagation channels, and the logistical effort associated with post-measurement data editing. This motivates the design and development of radiometers capable of coherent sampling and adaptive, real-time mitigation of interference. Such a radiometer will be described in this presentation. This design is capable of coherently-sampling up to 100 MHz bandwidth at L-band. RFI mitigation is implemented in FPGA components so that real-time suppression is achieved. The system currently uses a cascade of basic time- and frequency- domain detection and blanking techniques; more advanced algorithms are un- der consideration. The modular FPGA-based architecture provides other benefits, such as the ability to implement extremely stable digital filters and the ability to reconfigure the system "on the fly". An overview of the basic design along with on-the-air results from an initial implementation will be provided in the presentation. Related L-band RFI surveys will be described to illustrate the relevance of this approach in a variety of operating conditions.

Ellingson, S. W.↗

IsoMatchMS : Open-Source Software for Automated Annotation and Visualization of High Resolution MALDI-MS Spectra

Due to its speed, accuracy, and adaptability to various sample types, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has become a popular method to identify molecular isotope profiles from biological samples. Often MALDI-MS data do not include tandem MS fragmentation data, and thus the identification of compounds in samples requires external databases so that the accurate mass of detected signals can be matched to known molecular compounds. Most relevant MALDI-MS software tools developed to confirm compound identifications are focused on small molecules (e.g., metabolites, lipids) and cannot be easily adapted to protein data due to their more complex isotopic distributions. Here, we present an R package called IsoMatchMS for the automated annotation of MALDI-MS data for multiple datatypes: intact proteins, peptides, and glycans. This tool accepts already derived molecular formulas or, for proteomics applications, can derive molecular formulas from a list of input peptides or proteins including proteins with post-translational modifications. In conclusion, visualization of all matched isotopic profiles is provided in a highly accessible HTML format called a trelliscope display, which allows users to filter and sort by several parameters such as match scores and the number of peaks matched. IsoMatchMS simplifies the annotation and visualization of MALDI-MS data for downstream analyses.

47 OTHER INSTRUMENTATION↗

Structure and permeation mechanism of a mammalian urea transporter

As an adaptation to infrequent access to water, terrestrial mammals produce urine that is hyperosmotic to plasma. To prevent osmotic diuresis by the large quantity of urea generated by protein catabolism, the kidney epithelia contain facilitative urea transporters (UTs) that allow rapid equilibration between the urinary space and the hyperosmotic interstitium. Here we report the first X-ray crystal structure of a mammalian UT, UT-B, at a resolution of 2.36 {angstrom}. UT-B is a homotrimer and each protomer contains a urea conduction pore with a narrow selectivity filter. Structural analyses and molecular dynamics simulations showed that the selectivity filter has two urea binding sites separated by an approximately 5.0 kcal/mol energy barrier. Functional studies showed that the rate of urea conduction in UT-B is increased by hypoosmotic stress, and that the site of osmoregulation coincides with the location of the energy barrier.

59 BASIC BIOLOGICAL SCIENCES↗

Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy

Purpose: Real-time tracking of implanted fiducials in cine megavoltage (MV) imaging during volumetric modulated arc therapy (VMAT) delivery is complicated due to the inherent low contrast of MV images and potential blockage of dynamic leaves configurations. The purpose of this work is to develop a clinically practical autodetection algorithm for motion management during VMAT. Methods: The expected field-specific segments and the planned fiducial position from the Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system were projected onto the MV images. The fiducials were enhanced by applying a Laplacian of Gaussian filter in the spatial domain for each image, with a blob-shaped object as the impulse response. The search of implanted fiducials was then performed on a region of interest centered on the projection of the fiducial when it was within an open field including the case when it was close to the field edge or partially occluded by the leaves. A universal template formula was proposed for template matching and normalized cross correlation was employed for its simplicity and computational efficiency. The search region for every image was adaptively updated through a prediction model that employed the 3D position of the fiducial estimated from the localized positions in previous images. This prediction model allowed the actual fiducial position to be tracked dynamically and was used to initialize the search region. The artifacts caused by electronic interference during the acquisition were effectively removed. A score map was computed by combining both morphological information and image intensity. The pixel location with the highest score was selected as the detected fiducial position. The sets of cine MV images taken during treatment were analyzed with in-house developed software written in MATLAB (The Mathworks, Inc., Natick, MA). Five prostate patients were analyzed to assess the algorithm performance by measuring their positioning accuracy during treatment. Results: The algorithm was able to accurately localize the fiducial position on MV images with success rates of more than 90% per case. The percentage of images in which each fiducial was localized in the studied cases varied between 23% and 65%, with at least one fiducial having been localized between 40% and 95% of the images. This depended mainly on the modulation of the plan and fiducial blockage. The prostate movement in the presented cases varied between 0.8 and 3.5 mm (mean values). The maximum displacement detected among all patients was of 5.7 mm. Conclusions: An algorithm for automatic detection of fiducial markers in cine MV images has been developed and tested with five clinical cases. Despite the challenges posed by complex beam aperture shapes, fiducial localization close to the field edge, partial occlusion of fiducials, fast leaf and gantry movement, and inherently low MV image quality, good localization results were achieved in patient images. This work provides a technique for enabling real-time accurate fiducial detection and tumor tracking during VMAT treatments without the use of extra imaging dose.

60 APPLIED LIFE SCIENCES↗

SU-F-J-23: Field-Of-View Expansion in Cone-Beam CT Reconstruction by Use of Prior Information

Purpose: Cone-beam CT (CBCT) has become an integral part of online patient setup in an image-guided radiation therapy (IGRT). In addition, the utility of CBCT for dose calculation has actively been investigated. However, the limited size of field-of-view (FOV) and resulted CBCT image with a lack of peripheral area of patient body prevents the reliability of dose calculation. In this study, we aim to develop an FOV expanded CBCT in IGRT system to allow the dose calculation. Methods: Three lung cancer patients were selected in this study. We collected the cone-beam projection images in the CBCT-based IGRT system (X-ray volume imaging unit, ELEKTA), where FOV size of the provided CBCT with these projections was 410 × 410 mm{sup 2} (normal FOV). Using these projections, CBCT with a size of 728 × 728 mm{sup 2} was reconstructed by a posteriori estimation algorithm including a prior image constrained compressed sensing (PICCS). The treatment planning CT was used as a prior image. To assess the effectiveness of FOV expansion, a dose calculation was performed on the expanded CBCT image with region-of-interest (ROI) density mapping method, and it was compared with that of treatment planning CT as well as that of CBCT reconstructed by filtered back projection (FBP) algorithm. Results: A posteriori estimation algorithm with PICCS clearly visualized an area outside normal FOV, whereas the FBP algorithm yielded severe streak artifacts outside normal FOV due to under-sampling. The dose calculation result using the expanded CBCT agreed with that using treatment planning CT very well; a maximum dose difference was 1.3% for gross tumor volumes. Conclusion: With a posteriori estimation algorithm, FOV in CBCT can be expanded. Dose comparison results suggested that the use of expanded CBCTs is acceptable for dose calculation in adaptive radiation therapy. This study has been supported by KAKENHI (15K08691).

60 APPLIED LIFE SCIENCES↗

A simple novel device for air sampling by electrokinetic capture

A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

47 OTHER INSTRUMENTATION↗

Method and Apparatus for Evaluating the Visual Quality of Processed Digital Video Sequences

A Digital Video Quality (DVQ) apparatus and method that incorporate a model of human visual sensitivity to predict the visibility of artifacts. The DVQ method and apparatus are used for the evaluation of the visual quality of processed digital video sequences and for adaptively controlling the bit rate of the processed digital video sequences without compromising the visual quality. The DVQ apparatus minimizes the required amount of memory and computation. The input to the DVQ apparatus is a pair of color image sequences: an original (R) non-compressed sequence, and a processed (T) sequence. Both sequences (R) and (T) are sampled, cropped, and subjected to color transformations. The sequences are then subjected to blocking and discrete cosine transformation, and the results are transformed to local contrast. The next step is a time filtering operation which implements the human sensitivity to different time frequencies. The results are converted to threshold units by dividing each discrete cosine transform coefficient by its respective visual threshold. At the next stage the two sequences are subtracted to produce an error sequence. The error sequence is subjected to a contrast masking operation, which also depends upon the reference sequence (R). The masked errors can be pooled in various ways to illustrate the perceptual error over various dimensions, and the pooled error can be converted to a visual quality measure.

Watson, Andrew B.↗

Systems and methods of adaptive two-wavelength single-camera imaging thermography (ATSIT) for accurate and smart in-situ process temperature measurement during metal additive manufacturing

A two-wavelength, single-camera imaging thermography system for in-situ temperature measurement of a target, comprising: a target light path inlet conduit for receiving a target light beam reflected from the target; a beam splitter installed in a splitter housing at a distal end of the target light path conduit, wherein the beam splitter divides the target light beam into a first light beam and a second light beam; a first light path conduit emanating from the splitter housing comprising a first aperture iris installed within the first light path conduit for aligning the first light beam; a first band pass filter installed within the first light path conduit for regulating the first light beam to a first wavelength λ1 and an optional half waveplate installed within the first light path conduit to modulate a polarization ratio of the first light beam of λ1 wavelength; a second light path conduit emanating from the splitter housing comprising a second aperture iris installed within the second light path conduit for aligning the second light beam; a second band pass filter installed within the second light path conduit for regulating the second light beam to a second wavelength λ2; a junction housing, wherein distal ends of each of the first and second light path conduits are connected to the junction housing; a polarizing beam splitter installed in the junction housing, wherein the polarizing beam splitter reflects the first light beam of λ1 wavelength along the same path or a parallel path of the second light beam of λ2 wavelength that passes directly through the polarizing beam splitter unreflected to create a merged light beam comprising light of λ1 and λ2 wavelengths; and a light path outlet conduit connected to the junction for directing the merged beam to a high-speed camera for imaging.

Zhao, Xiayun↗

Improved Dynamical Constraints on the Mass of the Central Black Hole in NGC 404

We explore the nucleus of the nearby 10{sup 9} M{sub ⊙} early-type galaxy, NGC 404, using Hubble Space Telescope (HST)/STIS spectroscopy and WFC3 imaging. We first present evidence for nuclear variability in UV, optical, and infrared filters over a time period of 15 years. This variability adds to the already substantial evidence for an accreting black hole at the center of NGC 404. We then redetermine the dynamical black hole mass in NGC 404 including modeling of the nuclear stellar populations. We combine HST/STIS spectroscopy with WFC3 images to create a local color–M/L relation derived from stellar population modeling of the STIS data. We then use this to create a mass model for the nuclear region. We use Jeans modeling to fit this mass model to adaptive optics stellar kinematic observations from Gemini/NIFS. From our stellar dynamical modeling, we find a 3σ upper limit on the black hole mass of 1.5×10{sup 5} M{sub ⊙}. Given the accretion evidence for a black hole, this upper limit makes NGC 404 the lowest mass central black hole with dynamical mass constraints. We find that the kinematics of H{sub 2} emission line gas show evidence for non-gravitational motions preventing the use of gas dynamical modeling to constrain the black hole mass. Our stellar population modeling also reveals that the central, counter-rotating region of the nuclear cluster is dominated by ∼1 Gyr old populations.

79 ASTRONOMY AND ASTROPHYSICS↗

The human as a detector of changes in variance and bandwidth

The detection of changes in random process variance and bandwidth was studied. Psychophysical thresholds for these two parameters were determined using an adaptive staircase technique for second order random processes at two nominal periods (1 and 3 seconds) and damping ratios (0.2 and 0.707). Thresholds for bandwidth changes were approximately 9% of nominal except for the (3sec,0.2) process which yielded thresholds of 12%. Variance thresholds averaged 17% of nominal except for the (3sec,0.2) process in which they were 32%. Detection times for suprathreshold changes in the parameters may be roughly described by the changes in RMS velocity of the process. A more complex model is presented which consists of a Kalman filter designed for the nominal process using velocity as the input, and a modified Wald sequential test for changes in the variance of the residual. The model predictions agree moderately well with the experimental data. Models using heuristics, e.g. level crossing counters, were also examined and are found to be descriptive but do not afford the unification of the Kalman filter/sequential test model used for changes in mean.

Curry, R. E.↗

Systematic methods for knowledge acquisition and expert system development

Nine cooperating rule-based systems, collectively called AUTOCREW, were designed to automate functions and decisions associated with a combat aircraft's subsystem. The organization of tasks within each system is described; performance metrics were developed to evaluate the workload of each rule base, and to assess the cooperation between the rule-bases. Each AUTOCREW subsystem is composed of several expert systems that perform specific tasks. AUTOCREW's NAVIGATOR was analyzed in detail to understand the difficulties involved in designing the system and to identify tools and methodologies that ease development. The NAVIGATOR determines optimal navigation strategies from a set of available sensors. A Navigation Sensor Management (NSM) expert system was systematically designed from Kalman filter covariance data; four ground-based, a satellite-based, and two on-board INS-aiding sensors were modeled and simulated to aid an INS. The NSM Expert was developed using the Analysis of Variance (ANOVA) and the ID3 algorithm. Navigation strategy selection is based on an RSS position error decision metric, which is computed from the covariance data. Results show that the NSM Expert predicts position error correctly between 45 and 100 percent of the time for a specified navaid configuration and aircraft trajectory. The NSM Expert adapts to new situations, and provides reasonable estimates of hybrid performance. The systematic nature of the ANOVA/ID3 method makes it broadly applicable to expert system design when experimental or simulation data is available.

Belkin, Brenda L.↗