Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “active distribution systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Universal Passive Synchronization Method for Grid-Forming Inverters Without Mode Transition

Power systems are transforming with increasing levels of inverter-based resources (IBRs). This transformation requires critical roles of grid-forming (GFM) inverters replacing synchronous generators for bulk power system stabilization and ancillary services, also allowing flexible power system operation, such as microgrid that is operated by multiple GFM IBRs to achieve system resilience against contingencies. To realize the resilient power systems allowing flexible in-and-out operation of GFM IBRs potentially programmed with different primary controls, a synchronization method universally applicable, i.e., independent of control types, would be beneficial to ease the integration process, but it has not been actively studied. To fill the gap, this paper proposes a universal synchronization method that achieves a passive synchronization to enable a smooth transition in a grid with off-nominal system parameters, i.e., voltage and frequency. The logic proposed requires no modification on the primary control, thus applicable to any type of GFMs with a voltage reference input. To validate the concept, a simulation of an IEEE 13-bus benchmark system modified with 3 GFM inverters is presented. It simulates an inverter-driven black start scenario in which GFM inverters autonomously turn on and connect to the grid under heavy loading, using the synchronization logic. The case study demonstrates that GFM inverters can tune their voltage reference to smoothly synchronize without severe transients, and contribute to a seamless black start of the grid under unbalanced load conditions. Two GFM methods - Droop and dispatchable virtual oscillator control - are used for the demo to validate feasibility and interoperability of the passive synchronization.

black start↗

While legume-based rotation influences the chemical composition of mineral-associated organic matter, tillage has little effect on its persistence

Legume-based rotations are key to enhancing soil carbon (C) storage in stable forms such as mineral-associated organic matter (MAOM), improving soil health, and helping maintain long-term C stock. This study investigates how plant inputs and tillage practices influence the distribution, composition, and persistence of MAOM in wheat cropping systems when legumes are incorporated into the rotation. Soil samples were collected from Walla Walla silty loam of northeast Oregon, including conventional tillage (CT) and no-till (NT) treatments in a long-term dryland winter wheat (Triticum aestivum L.) and spring pea (Pisum sativum L.) rotation experiment, with an adjacent grass pasture (GP) plot serving as the baseline. Bulk soil, particulate organic matter (POM), and MAOM fractions were scanned using mid-infrared (Mid-IR) spectroscopy and analyzed for total C and nitrogen (N) as well as radiocarbon age, aggregate stability, and mineralizable C. In WP systems, NT promoted greater C accumulation and stabilization in MAOM than CT, reaching levels similar to those under native GP conditions. Furthermore, our findings indicate that decades of continuous legume-based rotation were insufficient to restore total bulk C content to levels observed in the undisturbed reference site (GP) in the 0–30 cm layer, with increases limited to the surface layer. The Mid-IR data provided insights into how cultivation may alter the chemical composition of MAOM. An increase in amide bands was observed in GP, while legume-based rotation systems favored an abundance of aliphatic (C-H) components in the MAOM fraction. In cultivated soils, C in MAOM exhibited longer residence times under arable conditions than in grassland, while POM remained an actively cycled pool across all treatments. Despite variations in the chemical composition of MAOM across treatments, mineralizable C emissions from MAOM fractions remained statistically unchanged during the 96-hour incubation period. Our findings suggest that soil physical protection, enhanced by reduced tillage, is the primary factor influencing MAOM cycling.

Carbon stabilization↗

Coupled-cluster techniques for computational chemistry: The CFOUR program package

An up-to-date overview of the CFOUR program system is given. After providing a brief outline of the evolution of the program since its inception in 1989, a comprehensive presentation is given of its well-known capabilities for high-level coupled-cluster theory and its application to molecular properties. Subsequent to this generally well-known background information, much of the remaining content focuses on lesser-known capabilities of CFOUR, most of which have become available to the public only recently or will become available in the near future. Each of these new features is illustrated by a representative example, with additional discussion targeted to educating users as to classes of applications that are now enabled by these capabilities. Lastly, some speculation about future directions is given, and the mode of distribution and support for CFOUR are outlined in the appendix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

When Spectral Modeling Meets Convolutional Networks: A Method for Discovering Reionization-era Lensed Quasars in Multiband Imaging Data

Over the last two decades, around 300 quasars have been discovered at z ≳ 6, yet only one has been identified as being strongly gravitationally lensed. We explore a new approach—enlarging the permitted spectral parameter space, while introducing a new spatial geometry veto criterion—which is implemented via image-based deep learning. We first apply this approach to a systematic search for reionization-era lensed quasars, using data from the Dark Energy Survey, the Visible and Infrared Survey Telescope for Astronomy Hemisphere Survey, and the Wide-field Infrared Survey Explorer. Our search method consists of two main parts: (i) the preselection of the candidates, based on their spectral energy distributions (SEDs), using catalog-level photometry; and (ii) relative probability calculations of the candidates being a lens or some contaminant, utilizing a convolutional neural network (CNN) classification. The training data sets are constructed by painting deflected point-source lights over actual galaxy images, to generate realistic galaxy–quasar lens models, optimized to find systems with small image separations, i.e., Einstein radii of θ E ≤ 1''. Visual inspection is then performed for sources with CNN scores of P lens > 0.1, which leads us to obtain 36 newly selected lens candidates, which are awaiting spectroscopic confirmation. These findings show that automated SED modeling and deep learning pipelines, supported by modest human input, are a promising route for detecting strong lenses from large catalogs, which can overcome the veto limitations of primarily dropout-based SED selection approaches.

High-redshift galaxies↗

A Multi-Instrument Cloud Condensation Nuclei Spectrum Product (Final Technical Report)

A wealth of observational data exists on the characteristics of atmospheric particulate matter, over multiple years, at the DOE ARM Southern Great Plains (SGP) Central Facility site. This site is located in a region of the country that frequently experiences weather extremes, and that is removed from many local sources of pollution but is affected by transported smoke, dust, and urban emissions. The relationships between particulate matter, cloud formation and evolution, and precipitation are therefore of strong interest, and are being explored via modeling on a variety of scales. These models require as input detailed information on the characteristics of particles capable of serving as the nuclei for cloud formation. Sufficient data exist to be able to put together a picture of the nature of the total aerosol and the cloud condensation nuclei (CCN) subset, and their variability, through merged data products. This study was aimed at exploiting the multiple measurement types at SGP to develop the first such multi-year estimates. Further, the resulting data were analyzed to understand temporal patterns ranging from hourly to seasonal, thereby gaining insights into the particle sources affecting the atmosphere in this region. DOE-funded datasets that were analyzed in this study include total particle number concentrations, submicron aerosol scattering coefficients, dry aerosol size distributions, and more recently, time-resolved submicron aerosol chemical composition. Data are also available for the number concentrations of particles that are activated in a cloud condensation nucleus instrument at a series of setpoint supersaturations, providing direct observations of the number concentrations of “CCN”. This variable is the quantity that is generally desired for inclusion in numerical models that seek to represent and predict the impacts of varying aerosol characteristics on the formation and microphysical properties of clouds. One limitation of the use of direct CCN observations is that they are not available for supersaturations larger than about 1%, which is insufficient for deep convection and may be insufficient even for shallow convection, depending on the nature of the available CCN and the dynamics of the cloud. We developed a data-based approach to representing the full aerosol size spectrum with size-dependent hygroscopicity, and used this to extrapolate CCN spectra beyond the limited measurements. Five years of SGP aerosol data (2009 -2013) were analyzed. As a side product of our work, we identified and communicated several previously-unflagged data quality issues. The resulting merged aerosol distributions, along with fits for seasonal averages, were published and submitted to the ARM archive as a special value-added product (VAP; submitted as a PI product). CCN spectra were computed for the same data period and will similarly be published and submitted to the archive for use by the community. We also note that our methodologies and findings have been discussed at several Joint ARM User Facility/Atmospheric System Research (ASR) Principal Investigators Meetings and that recent ARM/ASR aerosol data reporting strategies have included similar ideas for data merging, indicating that this work has had a lasting impact on ARM aerosol data acquisition and reporting. The proposed work advances the science of the interactions of aerosols, clouds and precipitation, with direct application to improve representation of such interactions for clouds in regional and global climate models. The archived data will continue to serve research studies in the future.

54 ENVIRONMENTAL SCIENCES↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Modeling the Functional Forms of Grid Disturbances

This report introduces a functional form that may be used to quantitatively predict the impacts of new grid tools and changing system qualities on the likelihoods, durations, and depths of various grid disturbances. Each disturbance scenario is modeled to have three component stages—avoidance, reactance and recovery, which together parametrically estimate one disturbance’s impacts. The modeled scenario is then placed and replicated within an analysis period to represent the likelihood or frequency of the scenario and its consequent impacts. Whereas analysts have struggled to define and apply metrics for grid resilience, the functional form introduced by this report shares units of measurement with accepted grid-status measures (e.g., numbers of customers currently experiencing a service outage). Furthermore, the integrated and averaged functional form over an analysis period provides a meaningful normalized performance metric (e.g., customer outage minutes per year) that is ultimately independent of the duration of the period of. The approach may be applied similarly regardless of the severity or frequency of the disturbances that are being analyzed. Because metrics can be chosen to be identical in both the hypothetical future and the actual historical past, the historical past eventually becomes the test of the future predictions, at least in a statistical sense. The authors originally developed this approach to facilitate analysis of the effects of transactive energy (TE) systems effects on electric power grid resilience. TE systems invite energy suppliers and consumers to actively collaborate toward the discovery of, and their responses to, the locational value of energy. The findings from this process are often embodied as energy prices, the dynamics of which indicate the locational value of energy and can further represent important grid service needs. While some academic papers claim to quantify the value of a specific TE system design toward grid resilience, the answer, in general, has been elusive. Not only do multiple and conflicting definitions of resilience and reliability exist, but countless TE systems are being invented. We conclude the following: (1) The ideal analysis should harmonize rather than differentiate resilience and reliability. Therefore, this report uses the more general term disturbance whenever the overloaded terms resilience and reliability can be avoided. (2) The effectiveness of TE systems must be mapped to underlying qualities of a TE system, thereby avoiding presumptions that every TE design offers similar advantages. The authors seek to evaluate the parametric effects of TE system qualities (e.g., spatial granularity, granularity of time steps, length of future prediction horizon) on avoiding, reacting to, and recovering from grid disturbances. Furthermore, any advantages (or disadvantages) must be fairly compared with the many alternative tools, systems, and strategies that might offer comparable benefits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Real-time Plume Monitoring for Deep Sea Mineral Extraction​

In the emerging industry of deep-sea mining for minerals and deposits (e.g. polymetallic nodules for nickel, cobalt, copper, and manganese), more data is required to understand the effects of sediment plume generation and predict the distribution of disturbed sediment. There are two main sources of plume generation, the first being at the active mining site where the “collector” directly removes the top layer of the sea floor. The other is the “midwater plume” consisting of unwanted sediment that was collected during extraction that is pumped back into the aphotic zone. The vast majority of plume generation is caused by the collector, causing detrimental and long-lasting impacts on seafloor ecosystems due to the lack of wave activity or strong currents at the sea floor. Therefore, it is crucial to invest in the infrastructure to support the study and constant monitoring over a large area of the sea floor where plume generation is present. Due to the limited number of usable channels and power requirements, current subsea wireless communications technologies are not well suited to instrumenting the large areas of the sea floor needed to monitor plume migration. The scope of this effort is to transition experimental demonstrations of high-bandwidth, full-duplex scalable underwater laser communications to the seafloor in an open ocean environment. Specifically tackling challenges associated with the dynamic nature of the subsea world, including but not limited to, deployment logistics, sustainability, and range. The goal is to enable the internet of underwater things for deep sea industries by broadening the capabilities of subsea communications. By using high-precision laser transmitters, many of the challenges current subsea optical systems face can be circumvented, such as power consumption, interference, and bandwidth limitations. This approach lends itself to wireless interlinking multi-node networks, in series or parallel, facilitating the implementation of a wide array of sensor types. This interlinking allows all the data gathered from the network to be processed through a single hardline uplink to the surface, lowering the complexity required for near real-time data processing. Additionally, the laser control systems produce metadata that can be used to help characterize the water column between the nodes. Combining data from various sensors such as turbidity, temperature, current velocity with metadata such as beam attenuation and deflection can produce a high-resolution model of sea floor conditions around an active mining zone. The resulting near real-time model can be used to optimize location and flow rate of the mining operation to minimize and quantify the environmental impact.

Mons, Ishan↗

Inference of Rock Flow and Mechanical Properties from Injection-Induced Microseismic Events During Geologic CO 2 Storage

Monitoring microseismic activities during CO 2 injection into geologic formations is important for ensuring the safety of the storage operations. The resulting data provide insight into the response of the storage formation to CO 2 injection and can be used to infer the underlying rock flow and mechanical properties. In this paper, assimilation of microseismic data is performed for dynamic characterization of the storage formation by using a stochastic simulation model to forecast the microseismic response of a geologic formation during CO 2 injection. Two modeling approaches are adopted to predict the space-time distribution of the injection-induced microseismicity. The first model is based on pore pressure relaxation assumption, while the second model uses coupled flow and geomechanics simulation to establish the complex physical relation between the storage formation properties and the corresponding microseismic responses during CO 2 injection. The stochastic predictive models in each case are used in ensemble data assimilation frameworks to estimate rock properties from the observed microseismic data. Two data assimilation methods are considered: (i) a new ensemble-based stochastic point process filter (EnPPF) that can directly integrate discrete microseismic events, and (ii) a variant of ensemble smoother, known as the ensemble smoother with multiple data assimilation (ES-MDA), which requires continuous representation of microseismic events for assimilation. The two methods are successfully applied to a geologically realistic model of the Farnsworth Field in Texas, with complex geologic flow units and interacting fault systems.

42 ENGINEERING↗

INSIGHTS INTO MARINE UNICELLULAR CYANOBACTERIAL AND NON-CYANOBACTERIAL DIAZOTROPHS THROUGH SINGLE-CELL ANALYSES

Nutrient availability affects primary productivity, and nitrogen (N) is the limiting nutrient over large regions of the ocean. Biological N fixation (BNF) is the conversion of atmospheric dinitrogen (N2) to bioavailable forms of N (ammonium and amino acids). A select group of Bacteria and Archaea, known as diazotrophs, are the only organisms capable of this conversion. BNF is a critical source of N in nutrient-depleted (oligotrophic) marine waters. As such, BNF studies are a fundamental component for better understanding primary productivity and carbon cycling, as well as parameterizing predictive future global ocean models. Unicellular diazotrophs are widespread in marine systems and, in some cases, important contributors of BNF. This dissertation investigates unicellular diazotrophs at the single-cell level, including: UCYN-A, a cyanobacterial diazotroph that lives in symbiosis with an algal host, non-cyanobacterial diazotrophs (NCDs), which are putative heterotrophs, as well as a specific NCD known as Gamma A, a commonly occurring organism throughout the tropics and subtropics that belongs to the class Gammaproteobacteria. The single-cell investigations used in these studies can provide high-resolution insights that are not possible from community-level analyses of BNF, such as the N2 fixation rate of individual cells and cell morphology. Singlecell nanoscale secondary ion mass spectrometry (nanoSIMS) analyses were used in chapter 2 and 3 to investigate the cell-specific N2 fixation rates of (2) UCYN-A in the viii cold waters of the Bering and Arctic Seas where N2 fixation was not previously believed to be possible, and (3) NCDs in the North Pacific Subtropical Gyre where we demonstrated the first direct evidence of NCD N2 fixation on open ocean particles. Chapter 4 focused on the uncultivated NCD, Gamma A, using geneFISH to visualize single cells in natural seawater samples. We successfully identified Gamma A by developing a fluorescent in situ hybridization (FISH) probe targeting the diazotrophic functional marker gene nifH, revealing Gamma A cells are most often attached to particles. Together these studies provide new insights into the distributions, activities, and physiologies of geographically widespread, unicellular diazotrophs, thus improving our understanding of their roles as sources of fixed N in the surface ocean.

Harding, K.↗

Integration of seismic-pressure-petrophysics inversion of continuous active-seismic monitoring data for monitoring and quantifying CO 2 plume (Final Report)

The overall objective of this project is to develop and validate an integrated package of joint seismic-pressure-petrophysics inversion (jSPPI) of continuous active-source seismic monitoring dataset capable of providing real-time monitoring of CO 2 plume during geologic carbon sequestration (GCS). The three specific developments include: (a) the methodologies for fast seismic full waveform inversion of continuous active source seismic monitoring, (CASSM) datasets for simultaneously estimating velocity and attenuation, and with data assimilation; (b) joint Bayesian petrophysical inversion of seismic models and pressure data for providing and updating CO 2 saturation models; (c) the methods using multiple datasets including (Crainfield and Frio-II borehole) synthetic, laboratory, and field CASSM datasets. The outcomes of jSPPI include (a) a workflow for processing CASSM data, (b) Bayesian inversion algorithms using CASSM data and pressure response data, and (c) integration with data assimilation algorithms for continuously updating site-specific models used for prediction and reservoir management. The validation of joint FWI will be conducted using synthetic models based on the Cranfield and Frio experiments as well as field CASSM datasets collected as part of the Frio-II pilot injection. To quantify and map the mass and distribution of CO 2 (saturation), we will jointly invert velocity and attenuation measurements from the FWI with a Bayesian approach using a rock physics model for attenuation (e.g., White’s attenuation model with two selected patch sizes (White, 1976; Dutta and Seriff, 1979)). The Bayesian inversion will be applied to each time step in the CASSM survey in an updating scheme, which integrates with an ensemble of reservoir simulations at each step. A more complete experimental validation dataset will be collected as part of a mesoscale (2-3 m) gas-CO 2 injection experiment utilizing a higher frequency version of the CASSM system developed for laboratory studies; the integrated inversion will be demonstrated using this dataset which will provide both a dense geometry as well as more precise secondary confirmation measurements (e.g. saturation) typically not available in the field. The resulting real-time map of CO 2 saturation is able to provide a deeper scientific understanding of the complex, time-varying dynamics of subsurface fluid flow migration path as well as the rapid detection of CO 2 leakage hazards.

25 ENERGY STORAGE↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data: Preprint

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Distinct Kinetic Signatures of Photodesorption from Metal Nanoparticles

Visible photon fluxes can influence the rate and selectivity of heterogeneously catalyzed reactions on metal nanoparticle surfaces. Models describing the influence of photon fluxes have typically introduced photon flux dependent apparent thermal kinetic parameters (reaction orders, activation energies, binding energies, etc.). This has relied on empirical fitting of reaction rate data, making mechanistic interpretations of how photon fluxes influence elementary step rates challenging and inconsistent with fundamental descriptions of photochemistry on metal surfaces developed from surface science studies. Using the CO adsorption–desorption quasi-equilibrium reaction on Pt/Al 2 O 3 catalysts as a model system, we measured steady state adsorbed CO (CO*) coverages under isothermal and isobaric (1 mbar CO) conditions as a function of temperature (473–573 K) and of 440 nm photon flux ((0.1–5.2) × 10 3 # hv Pt site –1 s –1 ) using in situ IR spectroscopy. Steady state CO* coverage on Pt was photon flux dependent with increasing photon flux causing decreasing coverage, consistent with photons driving CO* desorption rates faster than thermal CO* desorption rates. However, photon flux dependent CO* coverages were essentially temperature independent, inconsistent with models that describe photon effects using perturbations to apparent thermal kinetic parameters. Instead, 120 steady state CO* coverages as a function of temperature and photon flux are quantitatively described by a kinetic model in which the overall desorption rate is a summation of independent thermal and photon induced CO* desorption rates. Site-resolved analysis reveals distinct kinetic parameters for photon driven desorption of CO* from well-coordinated, under-coordinated, and highly under-coordinated Pt sites, with temperature-dependent apparent quantum efficiencies (AQE) consistent with temperature dependence of vibrational quanta distribution of adsorbed CO. The rigorous kinetic rate laws for independent photon and thermal driven pathways allow for predictive modeling of the influence of photon fluxes on the rates of CO* desorption under catalytic conditions. Further, the analysis provides evidence that steady state continuous wave photon fluxes can drive desorption/adsorption reactions on metal surfaces out of thermal equilibrium, reconciling surface science observations of molecular photodesorption with applied catalysis. The work establishes a general kinetic framework to be considered for photon driven processes on metals, and defines catalyst, reaction, and photon flux characteristic design principles for breaking Sabatier limitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of Photovoltaic Systems Recorded by Open Solar Performance and Reliability Clearinghouse (oSPARC)

This article analyzes data from 2,200 photovoltaic systems collected through the Open Solar Performance and Reliability Clearinghouse (oSPARC, 2018) to draw conclusions about the measured performance of the systems, how it compares to expectations, and how wide the variation is. The systems range in size from 2 kW to 1,200 kW, with an average size of 229 kW, and were activated in oSPARC between March 13, 2007 and Dec. 16, 2016. Data regarding co-incident insolation and ambient temperature are provided through the oSPARC platform for the population of systems and summarized here. Results indicate that - after correcting for measured insolation, derating for temperature, and correcting for balance-of-system efficiency and degradation as a result of system age - the performance ratio of these 2,200 systems averages 91.7%. Adjusting for known parameters such as age and efficiency, the ratio would ideally be 100%. Thus, the 'underperformance' of this system sample is measured at 9.3% and suggests that as much as 9.3% could be recovered if the systems were caused to perform as expected through optimal operation and maintenance. Efforts to correlate the performance ratio with environmental conditions resulted in very low coefficients of regression, but the method already normalizes for actual site insolation and temperature, which are responsible for much of the site-specific variation. An exemption is air-quality nonattainment areas, where the measured performance of plants averages 86.9% and is consistently lower than the average of 95.9% in areas that are in compliance with air quality standards, likely because of particulate matter such as diesel soot exacerbating the soiling rate.

14 SOLAR ENERGY↗

Editorial: Particulate Matter Emissions From Conventional and Reformulated Fuel Combustion: Advances in Experiments and Simulations

Particulate matter (PM or soot) emissions generated by combustion of conventional and reformulated fuels adversely impact the environment and human health (Bond et al., 2013; Landrigan et al., 2018; World Health Organization (WHO), 2016), generating public awareness and motivating efforts towards the mitigation of their harmful effects. Soot formation is one of the most complex phenomena in combustion, involving interactions between combustion chemistry, fluid mechanics, mass/heat transport, and particle dynamics, spanning different spatial and temporal scales. A fundamental understanding of soot formation process is thus necessary to achieve a strong reduction of PM emissions and design cleaner and more efficient combustion systems. This has motivated a longstanding and ongoing research activity aimed at improving our understanding of the physical and chemical processes involved in soot formation, well reviewed in these recent works (Wang and Chung, 2019; Michelsen et al., 2020; Martin et al., 2022). Despite the wide interest, the transition from gas-phase molecules to incipient soot particles is still elusive and the successive particle growth and oxidation processes are far from being fully understood, especially in conditions relevant to real-world applications. Recent advances in combustion PM emission diagnostic and computational capabilities helped in improving the predictability of fundamental chemical and aerosol models for practical applications, thus tackling some of the above-mentioned challenges. The aim of this research topic is to display the ongoing research efforts in addressing the existing gaps on particulate formation from various fuel sources and in conditions typical of practical combustion applications (e.g. flames, engines, pool fires), through both experimental and numerical approaches.

42 ENGINEERING↗

The Value of Sharing and Consolidating Critical Community, Electricity, and Natural Hazard Information

The California Public Utilities Commission (CPUC) sought support for the development of database schema specifications for a bi-directional data portal that would foster cross-jurisdictional collaboration necessary to improve resilient energy infrastructure planning processes. This technical assistance activity involved Berkeley Lab researchers reviewing 34 local/tribal government hazard mitigation plans to assess (1) the natural hazards that communities are most concerned about; (2) the variety of–and terminology used to describe–critical community infrastructure; and (3) the availability of GIS information that could be incorporated into CPUC-mandated "Microgrid Planning Portals". In addition, we develop a common, but generic data taxonomy showing what fields to collect to encourage consolidating and sharing of this information in the future. Finally, we partnered with the Bishop Paiute tribal government to demonstrate the value of combining electricity infrastructure, natural hazard layers, and critical community infrastructure into a series of maps. The project demonstrated that a single system containing both electric utility and community infrastructure data—as well as information about natural hazards—will help the state of California, the IOUs, first responders, and long-term planners better prepare for—and thus lower their exposure to these ongoing and emerging hazards. The project also identified a number of challenges that will need to be overcome before it is possible to stand up a single system to display this information.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis and design of DC-link capacitor in cascaded H-bridge multilevel active front-end converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. DC-link capacitors come with an expiration date which is dependent on the operating power and voltage values. Lack of information about the lifetime of the dc-link capacitor creates uncertainty in the duration of online operation of the converter, thus increasing the probability of a contingency outage. The lifetime of the capacitor can range from only a few seconds of online operation of the station due to under-sizing, to a compromised quality of power flowing through other solid state devices which may not have been designed for the transients that are caused by over-sizing of the dc-link capacitor. A better estimate of the lifetime of these capacitors can help maximize usage and maintain scheduled outages more efficiently, without disruption in service.

24 POWER TRANSMISSION AND DISTRIBUTION↗