Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLUME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Multichannel 0 → 2 and 1 → 2 transition amplitudes for arbitrary spin particles in a finite volume

We present a model-independent, non-perturbative relation between finite-volume matrix elements and infinite-volume $\textbf{0}\rightarrow\textbf{2}$ and $\textbf{1}\rightarrow\textbf{2}$ transition amplitudes. Our result accommodates theories in which the final two-particle state is coupled to any number of other two-body channels, with all angular momentum states included. The derivation uses generic, fully relativistic field theory, and is exact up to exponentially suppressed corrections in the lightest particle mass times the box size. This work distinguishes itself from previous studies by accommodating particles with any intrinsic spin. To illustrate the utility of our general result, we discuss how it can be implemented for studies of $N+\mathcal{J}~\rightarrow~(N\pi,N\eta,N\eta',\Sigma K,\Lambda K)$ transitions, where $\mathcal{J}$ is a generic external current. The reduction of rotational symmetry, due to the cubic finite volume, manifests in this example through the mixing of S- and P-waves when the system has nonzero total momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic heterogeneities, boson peak and activation volume in glass-forming liquids

There are various arguments and models connecting the characteristic length associated with the boson peak vibrations to the length scale of dynamical heterogeneity Lhet. is usually defined as the ratio of the transverse sound velocity to the boson peak frequency. Here we present pressure, temperature, and molecular weight dependencies of , estimated using light scattering, in a few molecular and polymeric glass formers. These dependencies are compared with respective dependencies of the activation volume V # in the same materials. Good agreement is found for the pressure and molecular weight dependencies of and V # measured at the glass transition temperature Tg. These results provide more evidence for a possible relationship between the sensitivity of structural relaxation to density (activation volume) and the heterogeneity volume. However, contrary to the expectations for Lhet, does not decrease with temperature above Tg in most of the studied materials. The temperature dependence of is compared to that of Lhet in glycerol and orthoterphenyl (OTP) estimated from literature data. The analysis shows a clear difference in the behavior of (T) and V #(T) at temperatures above Tg, although V #(T)1/3 and Lhet(T) have similar temperature dependence. Possible reasons for the observed difference are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scale setting of SU⁡(𝑁) Yang–Mills theory, topology and large-𝑁 volume independence

We set the scale of SU⁡(𝑁) Yang-Mills theories for 𝑁 =3, 5, 8 and in the large-𝑁 limit via gradient flow, as a first step towards the computation of the large-𝑁 Λ-parameter using step scaling. We adopt twisted boundary conditions to achieve large-𝑁 volume reduction and the Parallel Tempering on Boundary Conditions algorithm to tame topological freezing. This setup allows accurate determinations of the gradient-flow scales down to lattice spacings as fine as ∼0.025 fm for all the explored values of 𝑁, a regime that has never been reached with ergodic algorithms. Moreover, we are able to precisely estimate the finite-size systematics related to topological freezing, and to show the suppression of finite-volume effects expected by virtue of large-𝑁 twisted volume reduction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Water Volume Fraction Calculation in Multiphase Flows Using Electrical Capacitance Tomography Sensors

Real-time monitoring of water volume fraction in multiphase flows is an important problem for a number of industrial applications. The water phase in the multiphase flows may correspond to either the dispersed phase or the continuous phase. In the past, several lowcost and nonintrusive techniques based on the electrical capacitance tomography (ECT) has been developed to image and monitor in real-time multiphase flows containing water. Furthermore, such monitoring becomes increasingly challenging for high salinity levels, and no reliable ECTbased method is presently available which could work for obtaining water volume fraction in multiphase flows for all water salinity levels. In this paper, we propose a new approach based on the Hanai’s formula for complex dielectric constant and taking advantage of the Maxwell- Wagner-Sillars effect to obtain, to a good approximation, water volume fractions in multiphase flows containing water as either dispersed or continuous phase.

02 PETROLEUM↗

Uncertainty-Informed Volume Visualization using Implicit Neural Representation

The increasing adoption of Deep Neural Networks (DNNs) has led to their application in many challenging scientific visualization tasks. While advanced DNNs offer impressive generalization capabilities, understanding factors such as model prediction quality, robustness, and uncertainty is crucial. These insights can enable domain scientists to make informed decisions about their data. However, DNNs inherently lack ability to estimate prediction uncertainty, necessitating new research to construct robust uncertainty-aware visualization techniques tailored for various visualization tasks. In this work, we propose uncertainty-aware implicit neural representations to model scalar field data sets effectively and comprehensively study the efficacy and benefits of estimated uncertainty information for volume visualization tasks. We evaluate the effectiveness of two principled deep uncertainty estimation techniques: (1) Deep Ensemble and (2) Monte Carlo Dropout (MC-Dropout). These techniques enable uncertainty-informed volume visualization in scalar field data sets. Our extensive exploration across multiple data sets demonstrates that uncertainty-aware models produce informative volume visualization results. Moreover, integrating prediction uncertainty enhances the trustworthiness of our DNN model, making it suitable for robustly analyzing and visualizing real-world scientific volumetric data sets.

Saklani, Shanu↗

Early Time Evolution of Circumferential Perturbation of Initial Particle Volume Fraction in Explosive Cylindrical Multiphase Dispersion

When an annular bed of solid particles that surrounds a cylindrical high-energy explosive core gets radially dispersed after detonation, the expanding front of particles undergoes instabilities. One of the possible causes of the instabilities is an inhomogeneous initial distribution of particles. This study explores this possibility by introducing two-dimensional perturbations to the initial distribution of particles within the annular bed and quantifying the growth of these perturbations over time using two-dimensional simulations. The initial perturbations are in the form of superposition of up to three sinusoidal azimuthal modal variations in the initial particle volume fraction (PVF, ratio of particle to cell volume). These are observed to impact the particle distribution at later times through a channeling instability whose effects are: (i) to decrease the velocity in regions of larger particle volume (PV) and (ii) to facilitate circumferential particle migration into the slow moving high PV sectors. These departures from axisymmetry are quantified by introducing two metrics. The effect of varying the number of azimuthal modes contained in the initial PVF perturbation, along with their amplitudes, wavelengths, and relative phases is investigated. The proposed metrics do not vary substantially with the relative phases; however, there is a strong variation in the metrics due to changes in the wavenumber. Unimodal perturbations were found to amplify both metrics the most.

Engineering↗

Determination of volume fractions in two-phase flows from sound speed measurement

Accurate measurement of the composition of oil-water emulsions within the process environment is a challenging problem in the oil industry. Ultrasonic techniques are promising because they are non-invasive and can penetrate optically opaque mixtures. This paper presents a method of determining the volume fractions of two immiscible fluids in a homogenized two-phase flow by measuring the speed of sound through the composite fluid along with the instantaneous temperature. Two separate algorithms are developed by representing the composite density as (i) a linear combination of the two densities, and (ii) a non-linear fractional formulation. Both methods lead to a quadratic equation with temperature dependent coefficients, the root of which yields the volume fraction. The densities and sound speeds are calibrated at various temperatures for each fluid component, and the fitted polynomial is used in the final algorithm. We present results when the new algorithm is applied to mixtures of crude oil and process water from two different oil fields, and a comparison of our results with a Coriolis meter; the difference between mean values is less than 1%. Analytical and numerical studies of sensitivity of the calculated volume fraction to temperature changes and calibration errors are also presented.

02 PETROLEUM↗

Potential underestimation of the internal target volume (ITV) from free-breathing CBCT

Purpose: Localization prior to delivery of SBRT to free-breathing patients is performed by aligning the planning internal target volume (ITV) from 4DCT with an on-board free-breathing cone-beam CT (FB-CBCT) image. The FB-CBCT image is assumed to also generate an ITV that captures the full range of motion, due to the acquisition spanning multiple respiratory cycles. However, the ITV could potentially be underestimated when the ratio of time spent in inspiration versus time spent in expiration (I/E ratio) deviates from unity. Therefore, the aim of this study was to investigate the effect of variable I/E ratios on the FB ITV generated from a FB-CBCT scan. Methods: This study employed both phantom and patient imaging data. For the phantom study, five periodic respiratory cycles were simulated with different I/E ratios. Six patient respiratory cycles with variable I/E ratios were also selected. All profiles were then programmed into a motion phantom for imaging and modified to exhibit three peak-to-peak motion amplitudes (0.5, 1.0, and 2.0 cm). Each profile was imaged using two spherical targets with 1.0 and 3.0 cm diameters. 2D projections were acquired with full gantry rotation of a kiloVoltage (kV) imager mounted onto the gantry of a modern linear accelerator. CBCT images were reconstructed from 2D projections using a standard filtered back-projection reconstruction algorithm. Quantitative analyses for the phantom study included computing the change in contrast along the direction of target motion as well as determining the area (which is proportional to the target volume) inside of the contour extracted using a Canny edge detector. For the patient study, projection data that were previously acquired under an investigational 4D CBCT slow-gantry imaging protocol were used to generate both FB-CBCT and 4D CBCT images. Volumes were then manually contoured from both datasets (using the same window and level) for quantitative comparison. Results: The phantom study indicated a reduction in contrast at the inferior edge of the ITV (corresponding to inspiration) as the ratio decreased, for both simulated and patient respiratory cycles. For the simulated phantom respiratory cycles, the contrast reduction of the smallest I/E ratio was 27.6% for the largest target with the smallest amplitude and 89.7% for the smallest target with the largest amplitude. For patient respiratory cycles, these numbers were 22.3% and 94.0%, respectively. The extracted area from inside of the target contours showed a decreasing trend as the I/E ratio decreased. In the patient study, the FB-CBCT ITVs of both lung tumors studied were underestimated when compared with their corresponding 4D CBCT ITV. The underestimations found were 40.1% for the smaller tumor and 24.2% for the larger tumor. Conclusions: The ITV may be underestimated in a FB-CBCT image when a patient's respiratory pattern is characterized by a disparate length of time spent in inspiration versus expiration. Missing the full target motion information during on-board verification imaging may result in localization errors.

61 RADIATION PROTECTION AND DOSIMETRY↗

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-379: Concave Approximations of Target Volume Dose Metrics for Intensity- Modulated Radiotherapy Treatment Planning

Purpose: The widely used treatment plan metric Dx (mimimum dose to the hottest x% by volume of the target volume) is simple to interpret and use, but is computationally poorly behaved (non-convex), this impedes its use in computationally efficient intensity-modulated radiotherapy (IMRT) treatment planning algorithms. We therefore searched for surrogate metrics that are concave, computationally efficient, and accurately correlated to Dx values in IMRT treatment plans. Methods: To find concave surrogates of D95—and more generally, Dx values with variable x values—we tested equations containing one or two generalized equivalent uniform dose (gEUD) functions. Fits were obtained by varying gEUD ‘a’ parameter values, as well as the linear equation coefficients. Fitting was performed using a dataset of dose-volume histograms from 498 de-identified head and neck IMRT treatment plans. Fit characteristics were tested using a crossvalidation process. Reported root-mean-square error values were averaged over the cross-validation shuffles. Results: As expected, the two-gEUD formula provided a superior fit, compared to the single-gEUD formula. The best approximation uses two gEUD terms: 16.25 x gEUD[a=0.45] – 15.30 x gEUD[a=1.75] – 0.69. The average root-mean-square error on repeated (70/30) cross validation was 0.94 Gy. In addition, a formula was found that reasonably approximates Dx for x between 80% and 96%. Conclusion: A simple concave function using two gEUD terms was found that correlates well with PTV D95s for these head and neck treatment plans. More generally, a formula was found that represents well the Dx for x values from 80% to 96%, thus providing a computationally efficient formula for use in treatment planning optimization. The formula may need to be adjusted for other institutions with different treatment planning protocols. We conclude that the strategy of replacing Dx values with gEUD-based formulas is promising.

60 APPLIED LIFE SCIENCES↗

SU-C-204-03: In-Vivo Range Verification and Tissue Response to Proton Radiotherapy Using Prompt Gamma Volume Histograms

Purpose: To study if prompt gamma (PG) volume histograms created from PG images acquired during treatment delivery can be used to identify changes to beam range and tissue composition in response to proton radiotherapy. Methods: Monte Carlo simulations of a single field from a single treatment fraction (100 cGy) for prostate cancer were performed for the cases of: 1) an ideal patient setup, 1) a setup shift in the superior direction and 2) a reduction in oxygen concentration in the tumor. For each case, the 3 -Dimsional dose delivery and elemental PG emission in the patient for the treatment fraction were recorded and imported into a commercial treatment planning system. Changes in the dose volume histograms (DVH), as well as the PG volume histograms (PG-VH) for the PG emission from oxygen and for the total PG emission (from all elements) were analyzed. Results: For the 1 cm superior shift, the prostate DVH and total PG-VH both shifted toward lower doses with the shape of the curves remaining nearly unchanged, resulting in the DVH V95 dropping from 100 cGy to 90 cGy. For the total PG-VH, the V95 fell from 50 to 38. For the reduced oxygen case, both the DVH and PG-VH had a much different shape than for the ideal case, with a significant downward slope in the curves as a function of dose. Conclusions: The shift in the prostate PG-VH for a superior shift in the patient setup correlated well with the DVH indicating it is possible to detect setup errors by analyzing the PG-VH from prompt gamma images obtained during daily proton treatment delivery. Additionally, it may be possible to detect changes in the elemental concentrations of irradiated tissues by analyzing the shape of the PG-VH.

60 APPLIED LIFE SCIENCES↗

SU-D-213-04: Accounting for Volume Averaging and Material Composition Effects in An Ionization Chamber Array for Patient Specific QA

Purpose: This study explores novel methods to address two significant challenges affecting measurement of patient-specific quality assurance (QA) with IBA’s Matrixx Evolution™ ionization chamber array. First, dose calculation algorithms often struggle to accurately determine dose to the chamber array due to CT artifact and algorithm limitations. Second, finite chamber size and volume averaging effects cause additional deviation from the calculated dose. Methods: QA measurements were taken with the Matrixx positioned on the treatment table in a solid-water Multi-Cube™ phantom. To reduce the effect of CT artifact, the Matrixx CT image set was masked with appropriate materials and densities. Individual ionization chambers were masked as air, while the high-z electronic backplane and remaining solid-water material were masked as aluminum and water, respectively. Dose calculation was done using Varian’s Acuros XB™ (V11) algorithm, which is capable of predicting dose more accurately in non-biologic materials due to its consideration of each material’s atomic properties. Finally, the exported TPS dose was processed using an in-house algorithm (MATLAB) to assign the volume averaged TPS dose to each element of a corresponding 2-D matrix. This matrix was used for comparison with the measured dose. Square fields at regularly-spaced gantry angles, as well as selected patient plans were analyzed. Results: Analyzed plans showed improved agreement, with the average gamma passing rate increasing from 94 to 98%. Correction factors necessary for chamber angular dependence were reduced by 67% compared to factors measured previously, indicating that previously measured factors corrected for dose calculation errors in addition to true chamber angular dependence. Conclusion: By comparing volume averaged dose, calculated with a capable dose engine, on a phantom masked with correct materials and densities, QA results obtained with the Matrixx Evolution™ can be significantly improved. In addition, necessary correction factors are reduced, allowing for more reliable and meaningful patient-specific QA measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-288: Dose Volume Population Histogram (DVPH): A New Method to Evaluate Intensity Modulated Proton Therapy Plans With Geometrical Uncertainties

Purpose: In Proton therapy, especially intensity modulated proton therapy(IMPT), the dose distribution shape is very sensitive to errors due to sharp dose gradients at the Bragg peaks. The concept of the conventional margin is based on the assumption that dose distribution is shifted rather than deformed due to geometrical uncertainties. The goal of this study is to access the validity of the margin concept as well as propose a new approach using Dose Volume Population Histogram (DVPH) in evaluating IMPT plans. Methods: For a prostate case, an intensity modulated proton therapy is optimized based on the conventional PTV based objective function. The plan is evaluated based on the PTV DVH and CTV DVPH (dose volume population histogram) which explicitly taking into account geometric uncertainties. The DVPH is calculated based on 2197 dose distributions at different CTV possible positions for both random and systematic errors. The DVPH with a 90% confidence level is used for the comparison. Results: The minimum dose of the CTV DVPH with a 90% confidence level is only about 18% of the prescribed dose, while the minimum dose of the PTV is 95%. For bladder DVHs, the D50 and D35 is 26% and 30%, compared to 65% and 70% of the prescribed dose from the bladder DVPH with 90% confidence level. Conclusion: The results showed that the PTV concept for ensuring the prescribed dose actually delivered to the CTV is invalid in proton therapy. The good PTV DVH might Result in an underdose to the target and should not be used for IMPT optimization. For OARs, the conventional evaluation approach underestimates dose volume end points. The new concept DVPH has been proved to provide a more accurate DVH evaluation in proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-538: CyberKnife with MLC for Treatment of Large Volume Tumors: A Feasibility Study

Purpose: CyberKnife is a well-documented modality for SRS and SBRT treatments. Typical tumors are small and 1–5 fractions are usually used. We determined the feasibility of using CyberKnife, with an InCise multileaf collimator option, for larger tumors undergoing standard dose and fractionation. The intent was to understand the limitation of using this modality for other external beam radiation treatments. Methods: Five tumors from different anatomical sites with volumes from 127.8 cc to 1,320.5 cc were contoured and planned on a Multiplan V5.1 workstation. The target average diameter ranged from 7 cm to 13 cm. The dose fractionation was 1.8–2.0 Gy/fraction and 25–45 fractions for total doses of 45–81 Gy. The sites planned were: pancreas, head and neck, prostate, anal, and esophagus. The plans were optimized to meet conventional dose constraints based on various RTOG protocols for conventional fractionation. Results: The Multiplan treatment planning system successfully generated clinically acceptable plans for all sites studied. The resulting dose distributions achieved reasonable target coverage, all greater than 95%, and satisfactory normal tissue sparing. Treatment times ranged from 9 minutes to 38 minutes, the longest being a head and neck plan with dual targets receiving different doses and with multiple adjacent critical structures. Conclusion: CyberKnife, with the InCise multileaf collimation option, can achieve acceptable dose distributions in large volume tumors treated with conventional dose and fractionation. Although treatment times are greater than conventional accelerator time; target coverage and dose to critical structures can be kept within a clinically acceptable range. While time limitations exist, when necessary CyberKnife can provide an alternative to traditional treatment modalities for large volume tumors.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-08: Evaluation of Dose Mass Histogram as a More Representative Dose Description Method Than Dose Volume Histogram in Lung Cancer Patients

Purpose: Dose-volume-histogram (DVH) is widely used for plan evaluation in radiation treatment. The concept of dose-mass-histogram (DMH) is expected to provide a more representative description as it accounts for heterogeneity in tissue density. This study is intended to assess the difference between DVH and DMH for evaluating treatment planning quality. Methods: 12 lung cancer treatment plans were exported from the treatment planning system. DVHs for the planning target volume (PTV), the normal lung and other structures of interest were calculated. DMHs were calculated in a similar way as DVHs expect that the voxel density converted from the CT number was used in tallying the dose histogram bins. The equivalent uniform dose (EUD) was calculated based on voxel volume and mass, respectively. The normal tissue complication probability (NTCP) in relation to the EUD was calculated for the normal lung to provide quantitative comparison of DVHs and DMHs for evaluating the radiobiological effect. Results: Large differences were observed between DVHs and DMHs for lungs and PTVs. For PTVs with dense tumor cores, DMHs are higher than DVHs due to larger mass weighing in the high dose conformal core regions. For the normal lungs, DMHs can either be higher or lower than DVHs depending on the target location within the lung. When the target is close to the lower lung, DMHs show higher values than DVHs because the lower lung has higher density than the central portion or the upper lung. DMHs are lower than DVHs for targets in the upper lung. The calculated NTCPs showed a large range of difference between DVHs and DMHs. Conclusion: The heterogeneity of lung can be well considered using DMH for evaluating target coverage and normal lung pneumonitis. Further studies are warranted to quantify the benefits of DMH over DVH for plan quality evaluation.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-05: Spatial Co-Localization of F-18 NaF Vs. F-18 FDG Defined Disease Volumes

Purpose: Both [F-18]NaF and [F-18]FDG show promise for quantitative PET/CT assessment in metastatic prostate cancer to bone. Broad agreement between the tracers has been shown but voxel-wise correspondence has not been explored in depth. This study evaluates the spatial co-localization of [F-18]NaF PET and [F-18]FDG PET in bone lesions. Methods: Seventy-three lesion contours were identified in six patients receiving dynamic NaF PET/CT and FDG PET/CT scans two hours apart using identical fields-of-view. Tracer uptake (SUV) reflecting 60 minutes post-injection was modeled from kinetic parameters. Lesions were segmented by a physician separately on NaF PET and FDG PET. PET images were rigidly aligned using skeletal references on CT images. Lesion size, degree of overlap, voxel-wise tracer uptake values (SUV), and CT density distributions were compared using Dice coefficient, Positive Predictive Value (PPV), and Spearman rank correlation tests. Results: Across all patients, 42 lesions were identified on NaF PET (median 1.4 cm{sup 3}, range <1–204 cm{sup 3}) compared to 31 using FDG PET (median 1.8 cm{sup 3}, range <1–244 cm{sup 3}). Spatial cooccurrence was found in 25 lesion pairs. Lesions on NaF PET had PPV of 0.91 and on FDG a PPV of 0.65. Overall, NaF-defined lesions were 47% (±24%) larger by volume with moderate overlap to FDG, resulting in mean Dice coefficient of 34% (±22%). In areas of overlap, voxel-wise correlation of NaF and FDG SUV was moderate (ρ=0.56). Expanding to regions of non-spatial overlap, voxels contained in FDG-only contours were almost exclusively low HU (median 118), compared to dense regions of NaF-only voxels (median 250). In sclerotic sub-volumes (HU > 300) NaF-defined contours encompassed 83% of total FDG volume. Conclusion: Moderate voxel-wise correlation of FDG and NaF PET/CT uptake was observed. Spatial discrepancies in FDG and NaF PET/CT imaging of boney metastases could be influenced by poor sensitivity of FDG PET/CT in sclerotic regions. Funded by Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Formation of Vortex Flows in Liquid Crystal Phases Encapsulated in Microliter Volumes under the Action of Focused Laser Radiation

A theoretical description of the process of formation of vortex flows v(t, r) and the evolution of the director field n̂ in microliter liquid crystal (LC) volumes with a free surface under the influence of a temperature gradient ∇T(t, r), which is initiated by focused laser radiation, has been proposed. Thermomechanical contributions to both the stress tensor and viscous moment which are acting per unit volume of the LC phase were taken into account in the framework of the nonlinear generalization of the classical Ericksen−Leslie theory, which allowed describing the origin and formation of vortex flows in nematics formed by 4-n-pentyl- 4'-cyanobiphenyl molecules. Various hydrodynamic modes of vortex formation in microsized LC volumes under the action of focused laser radiation have been investigated by numerical methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗