Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

PERFORMANCE OF A LIQUID XENON CALORIMETER CRYOGENIC SYSTEM FOR THE MEG EXPERIMENT

The {mu}-particle rare decay physics experiment, the MU-E-GAMMA (MEG) experiment, will soon be operational at the Paul Scherrer Institute in Zurich. To achieve the extremely high sensitivity required to detect gamma rays, 800 L of liquid xenon is used as the medium in the calorimeter, viewed by 830 photomultiplier tubes (PMT) immersed in it. The required liquid xenon purity is of the order of ppb of water, and is obtained by using a cryogenic centrifugal pump and cold molecular sieves. The heat load of the calorimeter at 165 K is to be approximately 120 W, which is removed by a pulse-tube cryocooler developed at KEK and built by Iwatani Industrial Gas Corp., with a cooling power of about 200 W at 165 K. The cryogenic system is also equipped with a 1000-L dewar. This paper describes the results of an initial performance test of each cryogenic component.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-Complete Retention of Technetium During Vitrification of Hanford Low Activity Waste With Recycle - 17315

Technetium is one of the more volatile radionuclides for which retention in low activity waste (LAW) glass under the high temperature conditions during vitrification can vary depending on feed composition, feed chemistry, and melter operating parameters. High retention of technetium in the glass is desirable in order to minimize the fraction of technetium that is directed to secondary waste streams, which include liquid off-gas treatment system effluents. Consequently, test data are crucial to assess and underpin the assumptions underlying such mass balance projections, the compositions of secondary waste streams, and, in particular, the effects of recycle on increasing the incorporation of technetium in the glass products and minimizing the fraction in non-glass waste forms. Previous testing performed on a scaled melter system that incorporates prototypical off-gas treatment components and real-time recycle of the liquid effluents back to the melter feed demonstrated that recycle resulted in significant increases of the incorporation of technetium into the LAW glass product and behavior that was in good agreement with process models for the system. However, the maximum technetium retention achieved in those tests was less than predicted. Tests conducted in the present work demonstrated, for the first time, near-complete retention of technetium in the LAW glass product with recycle. Holdup of technetium in the vacuum evaporator, which concentrates the liquid effluents prior to their recycle to the melter feed, was identified as the primary reason for the previously observed shortfall. The fate of other volatile constituents was also assessed. In particular, in addition to technetium, rhenium, which is frequently used as a non-radioactive surrogate for technetium, was included in these tests. This allows for a direct comparison of the behavior of rhenium and technetium during vitrification and in the down-stream processes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Testing the Relative Oxidizing Hazard of Wipes and KMI Zeolite

This report includes the results from testing performed on the relative oxidizing hazard of a number of organic sorbing wipe materials, as well as KMI zeolite. These studies were undertaken to address a need by the Los Alamos National Laboratory (LANL) Hazardous Materials Management group, which requires a material that can sorb small spills in a glovebox without creating a disposal hazard due to the potential for oxidation reactions, as requested in Request for Testing of Wipes and Zeolite for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-002) and Request for Testing of Chamois Material for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-005). This set oftests is a continuation of previous testing described in Results from Preparation and Testing of Sorbents Mixed with (DWT-RPT-003), which provided data for the Waste Isolation Pilot Plant's Basis of Knowledge. The Basis of Knowledge establishes criteria for evaluating transuranic (TRU) waste that contains oxidizing chemicals.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards improved and more routine Earth system model evaluation in CMIP

The Coupled Model Intercomparison Project (CMIP) has successfully provided the climate community with a rich collection of simulation output from Earth system models (ESMs) that can be used to understand past climate changes and make projections and uncertainty estimates of the future. Confidence in ESMs can be gained because the models are based on physical principles and reproduce many important aspects of observed climate. More research is required to identify the processes that are most responsible for systematic biases and the magnitude and uncertainty of future projections so that more relevant performance tests can be developed. At the same time, there are many aspects of ESM evaluation that are well established and considered an essential part of systematic evaluation but have been implemented ad hoc with little community coordination. Given the diversity and complexity of ESM analysis, we argue that the CMIP community has reached a critical juncture at which many baseline aspects of model evaluation need to be performed much more efficiently and consistently. We provide a perspective and viewpoint on how a more systematic, open, and rapid performance assessment of the large and diverse number of models that will participate in current and future phases of CMIP can be achieved, and announce our intention to implement such a system for CMIP6. Accomplishing this could also free up valuable resources as many scientists are frequently "re-inventing the wheel" by re-writing analysis routines for well-established analysis methods. A more systematic approach for the community would be to develop and apply evaluation tools that are based on the latest scientific knowledge and observational reference, are well suited for routine use, and provide a wide range of diagnostics and performance metrics that comprehensively characterize model behaviour as soon as the output is published to the Earth System Grid Federation (ESGF). The CMIP infrastructure enforces data standards and conventions for model output and documentation accessible via the ESGF, additionally publishing observations (obs4MIPs) and reanalyses (ana4MIPs) for model intercomparison projects using the same data structure and organization as the ESM output. This largely facilitates routine evaluation of the ESMs, but to be able to process the data automatically alongside the ESGF, the infrastructure needs to be extended with processing capabilities at the ESGF data nodes where the evaluation tools can be executed on a routine basis. Efforts are already underway to develop community-based evaluation tools, and we encourage experts to provide additional diagnostic codes that would enhance this capability for CMIP. And, at the same time, we encourage the community to contribute observations and reanalyses for model evaluation to the obs4MIPs and ana4MIPs archives. The intention is to produce through the ESGF a widely accepted quasi-operational evaluation framework for CMIP6 that would routinely execute a series of standardized evaluation tasks. Over time, as this capability matures, we expect to produce an increasingly systematic characterization of models which, compared with early phases of CMIP, will more quickly and openly identify the strengths and weaknesses of the simulations. This will also reveal whether long-standing model errors remain evident in newer models and will assist modelling groups in improving their models. Finally, this framework will be designed to readily incorporate updates, including new observations and additional diagnostics and metrics as they become available from the research community.

54 ENVIRONMENTAL SCIENCES↗

GLYCOLIC ACID PHYSICAL PROPERTIES, IMPURITIES, AND RADIATION EFFECTS ASSESSMENT

The DWPF is pursuing alternative reductants/flowsheets to increase attainment to meet closure commitment dates. In fiscal year 2009, SRNL evaluated several options and recommended the further assessment of the nitric/formic/glycolic acid flowsheet. SRNL is currently performing testing with this flowsheet to support the DWPF down-select of alternate reductants. As part of the evaluation, SRNL was requested to determine the physical properties of formic and glycolic acid blends. Blends of formic acid in glycolic acid were prepared and their physical properties tested. Increasing amounts of glycolic acid led to increases in blend density, viscosity and surface tension as compared to the 90 wt% formic acid that is currently used at DWPF. These increases are small, however, and are not expected to present any difficulties in terms of processing. The effect of sulfur impurities in technical grade glycolic acid was studied for its impact on DWPF glass quality. While the glycolic acid specification allows for more sulfate than the current formic acid specification, the ultimate impact is expected to be on the order of 0.03 wt% sulfur in glass. Note that lower sulfur content glycolic acid could likely be procured at some increased cost if deemed necessary. A paper study on the effects of radiation on glycolic acid was performed. The analysis indicates that substitution of glycolic acid for formic acid would not increase the radiolytic production rate of H{sub 2} and cause an adverse effect in the SRAT or SME process. It has been cited that glycolic acid solutions that are depleted of O{sub 2} when subjected to large radiation doses produced considerable quantities of a non-diffusive polymeric material. Considering a constant air purge is maintained in the SRAT and the solution is continuously mixed, oxygen depletion seems unlikely, however, if this polymer is formed in the SRAT solution, the rheology of the solution may be affected and pumping of the solution may be hindered. A series of tests to determine whether the polymer will be formed is currently being outlined. The first phase will be a simple experiment where a simulated SRAT supernatant containing the 80:20 blend of glycolic - formic acid could be irradiated in the Co-60 gamma source at SRNL to a very large dose resembling the dose received by the radioactive SRAT solution after several weeks. The resulting solution could then be heated to simulate refluxing in the SRAT process. Finally a radioactive demonstration of the SRAT process should be performed in the SRNL Shielded Cells to confirm successful execution of the glycolic - formic acid flowsheet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of an Additively Manufactured Respirator for Personnel Protection from Particulates

Additively manufactured respirators (AMRs) made using rigid plastic can be fitted with repurposed filter media to yield a wearable mask capable of passing a quantitative fit test with criteria set for commercial, N95 health care particulate respirators. This has been verified through an evaluation study assessing AMR masks fabricated using open-source design files and a commercial fused-filament fabrication machine, using N95 filter cloth and a P100 respirator cartridge. A few examples of filter media not designed for human respiratory protection were also evaluated in an AMR mask but did not demonstrate filtering sufficient to pass the N95 test criteria. All attributes of an AMR mask system must be considered during design and when testing performance, including the mask frame, gasket, and the cord used to secure the mask to the face. AMR masks are not the same as commercially available respiratory masks. If AMR masks are used as personal protective equipment (PPE) during a crisis when there is a shortage of regular PPE it is important that wearers are fully informed of the differences, tradeoffs, and risks associated with their use. Quantitative fit testing and proper training on how to don and doff the AMR mask are important to help achieve the best possible outcome when they are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Role of Mathematical Methods in Efficiency Calibration and Uncertainty Estimation in Gamma Based Non-Destructive Assay - 12311

Mathematical methods are being increasingly employed in the efficiency calibration of gamma based systems for non-destructive assay (NDA) of radioactive waste and for the estimation of the Total Measurement Uncertainty (TMU). Recently, ASTM (American Society for Testing and Materials) released a standard guide for use of modeling passive gamma measurements. This is a testimony to the common use and increasing acceptance of mathematical techniques in the calibration and characterization of NDA systems. Mathematical methods offer flexibility and cost savings in terms of rapidly incorporating calibrations for multiple container types, geometries, and matrix types in a new waste assay system or a system that may already be operational. Mathematical methods are also useful in modeling heterogeneous matrices and non-uniform activity distributions. In compliance with good practice, if a computational method is used in waste assay (or in any other radiological application), it must be validated or benchmarked using representative measurements. In this paper, applications involving mathematical methods in gamma based NDA systems are discussed with several examples. The application examples are from NDA systems that were recently calibrated and performance tested. Measurement based verification results are presented. Mathematical methods play an important role in the efficiency calibration of gamma based NDA systems. This is especially true when the measurement program involves a wide variety of complex item geometries and matrix combinations for which the development of physical standards may be impractical. Mathematical methods offer a cost effective means to perform TMU campaigns. Good practice demands that all mathematical estimates be benchmarked and validated using representative sets of measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility of Percutaneous Intrahepatic Split by Microwave Ablation (PISA) After Portal Vein Embolization for Hypertrophy of Future Liver Remnant: The Radiological Stage-1 ALPPS

PurposeTo assess the feasibility of radiological stage-1 ALPPS, associating liver partition and portal vein ligation for staged hepatectomy, by combining portal vein embolization (PVE) with percutaneous intrahepatic split by ablation (PISA).Materials and MethodsThree patients (mean age 65.0 ± 7.3 years) underwent PVE and PISA. PISA was performed 21 days after PVE by microwave ablation to create a continuous intrahepatic cutting plane. Abdominal CT examinations were performed before and after PVE and PISA. The future liver remnant (FLR) volume was calculated by semiautomatic segmentation, and increase was reported as a percentage of the pre-procedural volume. The FLR/body weight (FLR/BW) ratio was calculated; a ratio greater than 0.8% was considered sufficient for guaranteeing adequate liver function after surgery. The liver function before and after PISA was also evaluated by 99mTc-mebrofenin hepatobiliary scintigraphy. Patients’ laboratory tests, performance status, ability to walk were assessed before and after PVE and PISA procedures.ResultsNo procedure-related complications were recorded. The FLR volume increase in each patient was 42.0, 33.1 and 30.4% within 21 days of PVE and 109.3, 68.1 and 71.7% within 10 days after PISA. The FLR/BW ratios were 0.76, 0.66, 0.63% and 1.13, 0.83, 0.83% after PVE and PISA procedures, respectively. Two patients underwent successful right hepatectomy; in one patient, despite 1.13% FLR/BW, surgery was not performed because of the absolute rejection of blood transfusion due to the patient’s religious convictions.ConclusionRadiological stage-1 ALPPS is a feasible, minimally invasive option to be further investigated to become an effective alternative to surgical stage-1 ALPPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of MQXF Quench Heater Insulation Strength and Test of Modified Design

The HL-LHC interaction region magnet triplets (Q1,Q2, and Q3) will be composed of superconducting Nb 3 Sn quadrupoles. The MQXF quadrupole protection system is based on CLIQ (Coupling-Loss Induced Quench system) and outer layer quench heaters. Furthermore, this paper reports a summary of quench heaters to coil high voltage tests performed on MQXF short and long coils in air after fabrication, and in air and He gas after magnet training. Breakdown voltage values demonstrate good margin with respect to the Electrical design criteria for the HL-LHC inner triplet mag-nets. A modification in the quench heater installation-with an extra layer of fiber glass between the coil and the quench heater trace-has been proposed and tested in a mirror magnet to further increase electrical margins. Results demonstrated improvements of high voltage margin at the expense of a clear increase of hot spot temperature.The baseline heater to coil insulation was assessed to be able to guarantee safe operation for the Nb 3 Sn quadrupole magnets for the interaction regions of HL-LHC.

43 PARTICLE ACCELERATORS↗

MEASUREMENT OF AMMONIA RELEASE FROM SALTSTONE

SRNL was requested by WSRC Waste Solidification Engineering to characterize the release of ammonia from saltstone curing at 95 C by performing experimental testing. These tests were performed with an MCU-type Tank 50H salt simulant containing 0, 50, and 200 mg/L ammonia. The testing program showed that above saltstone made from the 200 mg/L ammonia simulant, the vapor space ammonia concentration was about 2.7 mg/L vapor at 95 C. An upper 95% confidence value for this concentration was found to be 3.9 mg/L. Testing also showed that ammonia was chemically generated from curing saltstone at 95 C; the amount of ammonia generated was estimated to be equivalent to 121 mg/L additional ammonia in the salt solution feed. Even with chemical generation, the ammonia release from saltstone was found to be lower than its release from salt solution only with 200 mg/L ammonia.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-P-43: A Knowledge Based Approach to Guidelines for Software Safety

Purpose: In the fall of 2012, a survey was distributed to medical physicists across Canada. The survey asked the respondents to comment on various aspects of software development and use in their clinic. The survey revealed that most centers employ locally produced (in-house) software of some kind. The respondents also indicated an interest in having software guidelines, but cautioned that the realities of cancer clinics include variations, that preclude a simple solution. Traditional guidelines typically involve periodically repeating a set of prescribed tests with defined tolerance limits. However, applying a similar formula to software is problematic since it assumes that the users have a perfect knowledge of how and when to apply the software and that if the software operates correctly under one set of conditions it will operate correctly under all conditions Methods: In the approach presented here the personnel involved with the software are included as an integral part of the system. Activities performed to improve the safety of the software are done with both software and people in mind. A learning oriented approach is taken, following the premise that the best approach to safety is increasing the understanding of those associated with the use or development of the software. Results: The software guidance document is organized by areas of knowledge related to use and development of software. The categories include: knowledge of the underlying algorithm and its limitations; knowledge of the operation of the software, such as input values, parameters, error messages, and interpretation of output; and knowledge of the environment for the software including both data and users. Conclusion: We propose a new approach to developing guidelines which is based on acquiring knowledge-rather than performing tests. The ultimate goal is to provide robust software guidelines which will be practical and effective.

60 APPLIED LIFE SCIENCES↗

Evaluation of Aluminum-Boron Carbide Neutron Absorbing Materials for Interim Storage of Used Nuclear Fuel

The objective of this work was to understand the corrosion behavior of Boral® and Bortec® neutron absorbers over long-term deployment in a used nuclear fuel dry cask storage environment. Corrosion effects were accelerated by flowing humidified argon through an autoclave at temperatures up to 570°C. Test results show little corrosion of the aluminum matrix but that boron is leaching out of the samples. Initial tests performed at 400 and 570°C were hampered by reduced flow caused by the rapid build-up of solid deposits in the outlet lines. Analysis of the deposits by XRD shows that the deposits are comprised of boron trioxide and sassolite (H 3 BO 3 ). The collection of boron- containing compounds in the outlet lines indicated that boron was being released from the samples. Observation of the exposed samples using SEM and optical microscopy show the growth of new phases in the samples. These phases were most prominent in Bortec® samples exposed at 570°C. Samples of Boral® exposed at 570°C showed minimal new phase formation but showed nearly the complete loss of boron carbide particles. Boron carbide loss was also significant in Boral samples at 400°C. However, at 400°C phases similar to those found in Bortec® were observed. The rapid loss of the boron carbide particles in the Boral® is suspected to inhibit the formation of the new secondary phases. However, Material samples in an actual dry cask environment would be exposed to temperatures closer to 300°C and less water than the lowest test. The results from this study conclude that at the temperature and humidity levels present in a dry cask environment, corrosion and boron leaching will have no effect on the performance of Boral® and Bortec® to maintain criticality control.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Construction of an embankment with a fly and bottom ash mixture: field performance study

Fly ash and bottom ash are coal combustion by-products (CCBPs) that are generated in large quantities throughout the world. It is often economical to dispose ash as mixtures rather than separately; that notwithstanding, only a few studies have been performed to investigate the behavior of fly and bottom ash mixtures, particularly those with high contents of fly ash. Also, there is very limited data available in the literature on the field performance of structures constructed using ash mixtures. This paper describes the construction and the instrumentation of a demonstration embankment built with an ash mixture (60:40 by weight of fly ash:bottom ash) on State Road 641, Terre Haute, Ind. Monitoring of the demonstration embankment was conducted for a period of 1 year from the start of construction of the embankment. The settlement of the embankment stabilized approximately 5 months after the end of its construction. According to horizontal inclinometer readings, the differential settlement at the top of the embankment is about 5 mm. Results from field quality control tests performed during construction of the demonstration embankment and monitoring data from vertical and horizontal inclinometers and settlement plates indicate that the ash mixture investigated can be considered an acceptable embankment construction material.

01 COAL, LIGNITE, AND PEAT↗

Filter Measurement System for Nuclear Material Storage Canisters - Midyear Report FY 2013

A test system is being developed at Los Alamos National Laboratory to measure the aerosol collection efficiency of filters in the lids of canisters for storing special nuclear materials (Figure 1). Two FTS (filter test rig) systems are being constructed; one system (the “TA-55 system”) will be used in the LANL TA-55 facility with canister lids that have been exposed to nuclear material. The other FTS device (the “TA-3 system”) will be used in the LANL Radiation Protection group RP-2 Aerosol Engineering Facility. The “TA-3 system” will have an expanded analytical capability, compared to the “TA-55 system” system that will be used for operational performance testing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structure and Properties of VT6 Alloy Obtained by Layered Selective Sintering of a Powder

This paper is focused on a clarification and analysis of the regularities of formation of the structure and properties of samples of the titanium-based alloy VT6, obtained by methods of conventional metallurgy and formed by layered selective electron-beam sintering in vacuum (using the Arcam A2X (3D printer) system (Arcam, Sweden)) of VT6 titanium powder with particle size 40–100 μm. Additional modification of the samples was realized by irradiating the surface with an intense pulsed electron beam (15 keV, 45 J/cm{sup 2}, 200 μs, 10 pulses, 0.3 s{sup –1}, 3.5·10{sup –2} Pa). It is shown that the action of a pulsed electron beam on the surface of samples formed by layered selective electron-beam sintering leads to a significant reduction in the porosity of the surface layer of the material and formation in the surface layer of a polycrystalline structure (grain size 15–60 μm) with a substructure in the form of crystallization cells (cell size 0.5–1.2 μm). Electron-beam processing of samples prepared by methods of conventional metallurgy for the indicated electron-beam parameters leads to the formation in the surface layer of a polycrystalline structure (grain size 50–800 μm) with a laminar intragrain substructure. Mechanical tests, performed by stretching flat samples, showed that the highest combination of mechanical strength and plasticity is possessed by samples obtained by layered selective electron-beam sintering with subsequent irradiation by an intense pulsed electron beam.

36 MATERIALS SCIENCE↗

Preliminary Study on TRISO Fuel Cross Section Generation

Cross section self-shielding methodologies for TRISO fuel were assessed to provide accurate multigroup cross sections for a high-fidelity reactor physics code so that the code is able to accurately model and simulate advanced reactors with TRISO fuel. Initially, the two existing methodologies (the SCALE method and the Sanchez-Pomraning method) were studied and implemented to MC2-3 for detailed performance tests. Additionally, a new spatial self-shielding method, named the iterative local spatial self-shielding (ILSS) method, for particulate fuels was developed based on the disadvantage factor and implemented to MC2-3 as well. The new method approximately accounts for the effect of randomly distributed particles on the particle shadowing effect using a homogenized compact region surrounding a particle of interest at the center. The self-shielded cross sections of the particle at the center are determined iteratively since the cross sections of the homogenized compact region are calculated using them. For the energy range above 100 keV where the fuel-to-moderator ratio is more important than the random distribution of particles, a single particle unit-cell model is used by preserving the average amount of moderator per fuel particle in the system. The three self-shielding methods implemented in MC2-3 were tested using numerical benchmark problems made based on fuel compact problems of a prismatic-type very high temperature reactor. Test results indicated that the ILSS method produced slightly better results than the SCALE and Sanchez-Pomraning methods, compared to the Serpent-2 Monte Carlo results obtained with 25 independent random particle configurations. The SCALE and Sanchez-Pomraning methods tend to underestimate the heterogeneity effect by 150 and 100 pcm, respectively, while the new ILSS method overestimates the heterogeneity effect by 70 pcm. In future, the new self-shielding method will be extended to perform pebble calculations and compare results with those from the SCALE and Sanchez-Pomraning methods. Furthermore, the new method will be optimized for practical applications to on-the-fly resonance treatment for lattice or whole-core calculations for advanced reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experiments and Simulation of a Borehole in Salt to Understand Heat, Brine, and Vapor Migration - 19192

Disposition of heat-generating nuclear waste (HGNW) remains a continuing technical and sociopolitical challenge. Numerous concepts for HGNW management have been proposed and examined internationally, including an extensive focus on geologic disposal. One proposed geologic material is salt because of its low permeability and viscoplastic deformation that causes self-repair of damage done to the salt by waste emplacement activities. Evaluating the safety and technical challenges of storing HGNW in a salt repository is an ongoing process involving experiments and supporting numerical simulation. Currently an experiment is underway at the Waste Isolation Pilot Plant (WIPP) to explore how the presence of a heat generating source affects phenomena such as brine migration, vapor transport, and mechanical changes to the bedded salt. A sub-horizontal heated borehole test is in progress in the underground at the WIPP that includes a centrally located 10.2 cm diameter borehole with an adjustable heater surrounded with smaller diameter boreholes instrumented with thermocouples. The central borehole contains an inflatable packer, heating block, brine sampler, and constantly flowing nitrogen gas circulation system. Air-injection tests performed in the central borehole provide pressure measurements that are used to constrain permeability of the system. The steady-state temperatures, as well as the rise and fall of temperature when the heater is cycled on and off, have been measured for up to 60 days. In the borehole, dry nitrogen gas circulation evaporates water and outflows to a desiccant container where water mass is measured daily during the experiment to quantify vapor removal. Although this test is a 'shake-down' for a planned second round of fresh borehole testing, we have gathered a rich dataset. These data allow us to build simulations using the Finite Element Heat and Mass transfer code (FEHM) to evaluate the experimental results, determine field-scale parameters, and identify code improvements to reproduce important physical processes that may not be accounted for at present. A 3-D numerical mesh, built using LaGrit software (lagrit.lanl.gov; Miller et al., 2007), includes increasing resolution around the central borehole. Modeling of the experiment allows for determining the local thermal conductivity and permeability of any damaged bedded salt around the borehole, where damage from drilling may change the permeability, porosity and saturation conditions, by parameter testing and inverse methods. Additionally, assumptions about brine and vapor flow and transport are being tested by comparing measured and simulated results. The combination of experimental data and model results provide additional data to help support the safety case for safe and effective HGNW disposition in bedded salt formations. Initial results from this experiment show that water flow into the borehole is within previous experimental results. Further, we have found that the design of the heater block is restricting energy to flow into the rock salt. Thus, this test has proven useful in design of the next generation experiment where infrared heating may be used to bypass issues caused by air gaps located around the current stainless steel block heater. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗