SU-E-T-114: Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms

Purpose: To evaluate whether a 3D patient-specific phantom is better able to detect known MLC errors in a clinically delivered treatment plan than conventional phantoms. 3D printing may make fabrication of such phantoms feasible. Methods: Two types of MLC errors were introduced into a clinically delivered, non-coplanar IMRT, partial brain treatment plan. First, uniformly distributed random errors of up to 3mm, 2mm, and 1mm were introduced into the MLC positions for each field. Second, systematic MLC-bank position errors of 5mm, 3.5mm, and 2mm due to simulated effects of gantry and MLC sag were introduced. The original plan was recalculated with these errors on the original CT dataset as well as cylindrical and planar IMRT QA phantoms. The original dataset was considered to be a perfect 3D patient-specific phantom. The phantoms were considered to be ideal 3D dosimetry systems with no resolution limitations. Results: Passing rates for Gamma Index (3%/3mm and no dose threshold) were calculated on the 3D phantom, cylindrical phantom, and both on a composite and field-by-field basis for the planar phantom. Pass rates for 5mm systematic and 3mm random error were 86.0%, 89.6%, 98% and 98.3% respectively. For 3.5mm systematic and 2mm random error the pass rates were 94.7%, 96.2%, 99.2% and 99.2% respectively. For 2mm systematic error with 1mm random error the pass rates were 99.9%, 100%, 100% and 100% respectively. Conclusion: A 3D phantom with the patient anatomy is able to discern errors, both severe and subtle, that are not seen using conventional phantoms. Therefore, 3D phantoms may be beneficial for commissioning new treatment machines and modalities, patient-specific QA and end-to-end testing.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-08: In-Vivo EPID Dosimetry: Quantifying the Detectability of Four Classes of Errors

Purpose: EPID dosimetry is an emerging method for treatment verification and QA. Given that the in-vivo EPID technique is in clinical use at some centers, we investigate the sensitivity and specificity for detecting different classes of errors. We assess the impact of these errors using dose volume histogram endpoints. Though data exist for EPID dosimetry performed pre-treatment, this is the first study quantifying its effectiveness when used during patient treatment (in-vivo). Methods: We analyzed 17 patients; EPID images of the exit dose were acquired and used to reconstruct the planar dose at isocenter. This dose was compared to the TPS dose using a 3%/3mm gamma criteria. To simulate errors, modifications were made to treatment plans using four possible classes of error: 1) patient misalignment, 2) changes in patient body habitus, 3) machine output changes and 4) MLC misalignments. Each error was applied with varying magnitudes. To assess the detectability of the error, the area under a ROC curve (AUC) was analyzed. The AUC was compared to changes in D99 of the PTV introduced by the simulated error. Results: For systematic changes in the MLC leaves, changes in the machine output and patient habitus, the AUC varied from 0.78–0.97 scaling with the magnitude of the error. The optimal gamma threshold as determined by the ROC curve varied between 84–92%. There was little diagnostic power in detecting random MLC leaf errors and patient shifts (AUC 0.52–0.74). Some errors with weak detectability had large changes in D99. Conclusion: These data demonstrate the ability of EPID-based in-vivo dosimetry in detecting variations in patient habitus and errors related to machine parameters such as systematic MLC misalignments and machine output changes. There was no correlation found between the detectability of the error using the gamma pass rate, ROC analysis and the impact on the dose volume histogram. Funded by grant R18HS022244 from AHRQ.

60 APPLIED LIFE SCIENCES↗

Cluster Mass Calibration at High Redshift: HST Weak Lensing Analysis of 13 Distant Galaxy Clusters from the South Pole Telescope Sunyaev-Zel’dovich Survey

We present an HST/Advanced Camera for Surveys (ACS) weak gravitational lensing analysis of 13 massive high-redshift (z(median) = 0.88) galaxy clusters discovered in the South Pole Telescope (SPT) Sunyaev-Zel'dovich Survey. This study is part of a larger campaign that aims to robustly calibrate mass-observable scaling relations over a wide range in redshift to enable improved cosmological constraints from the SPT cluster sample. We introduce new strategies to ensure that systematics in the lensing analysis do not degrade constraints on cluster scaling relations significantly. First, we efficiently remove cluster members from the source sample by selecting very blue galaxies in V - I colour. Our estimate of the source redshift distribution is based on Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) data, where we carefully mimic the source selection criteria of the cluster fields. We apply a statistical correction for systematic photometric redshift errors as derived from Hubble Ultra Deep Field data and verified through spatial cross-correlations. We account for the impact of lensing magnification on the source redshift distribution, finding that this is particularly relevant for shallower surveys. Finally, we account for biases in the mass modelling caused by miscentring and uncertainties in the concentration-mass relation using simulations. In combination with temperature estimates from Chandra we constrain the normalization of the mass-temperature scaling relation ln (E(z) M-500c/10(14)M(circle dot)) = A + 1.5ln (kT/7.2 keV) to A = 1.81(-0.14)(+0.24)(stat.)+/- 0.09(sys.), consistent with self-similar redshift evolution when compared to lower redshift samples. Additionally, the lensing data constrain the average concentration of the clusters to c(200c) = 5.6(-1.8)(+3.7).

cosmology: observations↗

Evaluating the Uncertainty of Terrestrial Water Budget Components Over High Mountain Asia

This study explores the uncertainties in terrestrial water budget estimation over High Mountain Asia (HMA) using a suite of uncoupled land surface model (LSM) simulations. The uncertainty in the water balance components of precipitation (P), evapotranspiration (ET), runoff (R), and terrestrial water storage (TWS) is significantly impacted by the uncertainty in the driving meteorology, with precipitation being the most important boundary condition. Ten gridded precipitation datasets along with a mix of model-, satellite-, and gauge-based products, are evaluated first to assess their suitability for LSM simulations over HMA. The datasets are evaluated by quantifying the systematic and random errors of these products as well as the temporal consistency of their trends. Though the broader spatial patterns of precipitation are generally well captured by the datasets, they differ significantly in their means and trends. In general, precipitation datasets that incorporate information from gauges are found to have higher accuracy with low Root Mean Square Errors and high correlation coefficient values. An ensemble of LSM simulations with selected subset of precipitation products is then used to produce the mean annual fluxes and their uncertainty over HMA in P, ET, and R to be 2.11 ± 0.45, 1.26 ± 0.11, and 0.85 ± 0.36 mm per day, respectively. The mean annual estimates of the surface mass (water) balance components from this model ensemble are comparable to global estimates from prior studies. However, the uncertainty/spread of P, ET, and R is significantly larger than the corresponding estimates from global studies. A comparison of ET, snow cover fraction, and changes in TWS estimates against remote sensing-based references confirms the significant role of the input meteorology in influencing the water budget characterization over HMA and points to the need for improving meteorological inputs.

Yoon, Yeosang↗

Forces from Stochastic Density Functional Theory under Nonorthogonal Atom-Centered Basis Sets

We develop a formalism for calculating forces on the nuclei within the linear-scaling stochastic density functional theory (sDFT) in a nonorthogonal atom-centered basis set representation (Fabian et al. Wiley Interdiscip. Rev.: Comput. Mol. Sci. 2019, 9, e1412, 10.1002/wcms.1412) and apply it to the Tryptophan Zipper 2 (Trp-zip2) peptide solvated in water. We use an embedded-fragment approach to reduce the statistical errors (fluctuation and systematic bias), where the entire peptide is the main fragment and the remaining 425 water molecules are grouped into small fragments. We analyze the magnitude of the statistical errors in the forces and find that the systematic bias is of the order of 0.065 eV/Å (~1.2 × 10 -3 E h / a 0 ) when 120 stochastic orbitals are used, independently of system size. This magnitude of bias is sufficiently small to ensure that the bond lengths estimated by stochastic DFT (within a Langevin molecular dynamics simulation) will deviate by less than 1% from those predicted by a deterministic calculation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Weak-lensing mass calibration of redMaPPer galaxy clusters in Dark Energy Survey Science Verification data

We use weak-lensing shear measurements to determine the mean mass of optically selected galaxy clusters in Dark Energy Survey Science Verification data. In a blinded analysis, we split the sample of more than 8,000 redMaPPer clusters into 15 subsets, spanning ranges in the richness parameter $5 \leq \lambda \leq 180$ and redshift $0.2 \leq z \leq 0.8$, and fit the averaged mass density contrast profiles with a model that accounts for seven distinct sources of systematic uncertainty: shear measurement and photometric redshift errors; cluster-member contamination; miscentering; deviations from the NFW halo profile; halo triaxiality; and line-of-sight projections. We combine the inferred cluster masses to estimate the joint scaling relation between mass, richness and redshift, $\mathcal{M}(\lambda,z) \varpropto M_0 \lambda^{F} (1+z)^{G}$. We find $M_0 \equiv \langle M_{200\mathrm{m}}\,|\,\lambda=30,z=0.5\rangle=\left[ 2.35 \pm 0.22\ \rm{(stat)} \pm 0.12\ \rm{(sys)} \right] \cdot 10^{14}\ M_\odot$, with $F = 1.12\,\pm\,0.20\ \rm{(stat)}\, \pm\, 0.06\ \rm{(sys)}$ and $G = 0.18\,\pm\, 0.75\ \rm{(stat)}\, \pm\, 0.24\ \rm{(sys)}$. The amplitude of the mass-richness relation is in excellent agreement with the weak-lensing calibration of redMaPPer clusters in SDSS by Simet et al. (2016) and with the Saro et al. (2015) calibration based on abundance matching of SPT-detected clusters. Our results extend the redshift range over which the mass-richness relation of redMaPPer clusters has been calibrated with weak lensing from $z\leq 0.3$ to $z\leq0.8$. Calibration uncertainties of shear measurements and photometric redshift estimates dominate our systematic error budget and require substantial improvements for forthcoming studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Effective field theory approach to heavy quark fragmentation

Using an approach based on Soft Collinear Effective Theory (SCET) and Heavy Quark Effective Theory (HQET) we determine the b-quark fragmentation function from electron-positron annihilation data at the Z-boson peak at next-to-next-to leading order with next-to-next-to leading log resummation of DGLAP logarithms, and next-to-next-to-next-to leading log resummation of endpoint logarithms. This analysis improves, by one order, the previous extraction of the b-quark fragmentation function. We find that while the addition of the next order in the calculation does not much shift the extracted form of the fragmentation function, it does reduce theoretical errors indicating that the expansion is converging. Using an approach based on effective field theory allows us to systematically control theoretical errors. Furthermore, while the fits of theory to data are generally good, the fits seem to be hinting that higher order correction from HQET may be needed to explain the b-quark fragmentation function at smaller values of momentum fraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The intrinsic quasar luminosity function: Accounting for accretion disk anisotropy

Quasar luminosity functions are a fundamental probe of the growth and evolution of supermassive black holes. Measuring the intrinsic luminosity function is difficult in practice, due to a multitude of observational and systematic effects. As sample sizes increase and measurement errors drop, characterizing the systematic effects is becoming more important. It is well known that the continuum emission from the accretion disk of quasars is anisotropic—in part due to its disk-like structure—but current luminosity function calculations effectively assume isotropy over the range of unobscured lines of sight. Here, we provide the first steps in characterizing the effect of random quasar orientations and simple models of anisotropy on observed luminosity functions. We find that the effect of orientation is not insignificant and exceeds other potential corrections such as those from gravitational lensing of foreground structures. We argue that current observational constraints may overestimate the intrinsic luminosity function by as much as a factor of ∼2 on the bright end. This has implications for models of quasars and their role in the universe, such as quasars' contribution to cosmological backgrounds.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-B-BRC-00: How to Identify and Resolve Potential Clinical Errors Before They Impact Patients Treatment: Lessons Learned

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

TH-B-BRC-01: How to Identify and Resolve Potential Clinical Errors

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

TH-B-BRC-02: Troubleshooting Issues with Linear Accelerator

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

TH-B-BRC-03: Measurement and Calibration Discrepancy: Advanced Warning Guidance

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

Simultaneous Sensing Error Recovery and Tomographic Inversion Using an Optimization-Based Approach

Tomography can be used to reveal internal properties of a 3D object using any penetrating wave. Advanced tomographic imaging techniques, however, are vulnerable to both systematic and random errors associated with the experimental conditions, which are often beyond the capabilities of the state-of-the-art reconstruction techniques such as regularizations. Because they can lead to reduced spatial resolution and even misinterpretation of the underlying sample structures, these errors present a fundamental obstacle to full realization of the capabilities of next-generation physical imaging. In this work, we develop efficient and explicit recovery schemes of the most common experimental error: movement of the center of rotation during the experiment. We formulate new physical models to capture the experimental setup, and we devise new mathematical optimization formulations for reliable inversion of complex samples. We demonstrate and validate the efficacy of our approach on synthetic data under known perturbations of the center of rotation.

Nonlinear optimization↗

MO-E-BRB-04: Real-Time Exit-Fluence Delivery Validation

Recent high profile reports of technical failures and human errors causing severe radiation- induced injuries and deaths come in support of the sustained efforts to ensure patient safety in the delivery of radiation treatments. In addition, highly conformal radiation therapies and escalated fraction doses mandate increased and sustained accuracy of the entire radiotherapy process. Consequently, and as a Result of AAPM and ASTRO led efforts patient specific quality assurance for specialized radiation treatments such as IMRT, SRS/SBRT and Arc Therapy had become a three-tier process: Pre-treatment, during treatment, and post treatment patient specific QA. Traditional patient QA consists of pre-treatment data transfer integrity dosimetric verifications and during-treatment geometric verifications. However, as treatment adaptation becomes closer to deployment in the clinics, during treatment validation via exit detectors had become a realistic QA option, permitting plan assessment in near real time. Post-treatment, machine logs allow comparisons of a range of mechanical parameters. A combination of these techniques could be used in evaluating inter-fraction, and intra-fraction delivery over a long time period such as an year, to evaluate the significant errors per site, per treatment technique. This type of data mining over longer periods of time provides the potential to recognize suboptimal radiation treatments, while allowing to identify systematic, possibly significant errors. This would allow creation of a data base of realized errors, small and large in dosimetry that could be for process or equipment improvement. This educational symposium will describe and review patient QA techniques, results, and strategies for patient specific quality assurance. Learning Objectives: review the goals of pre-treatment QA for various specialized procedures review methods and means for pre-treatment QA, limitations and tolerances review the scenarios where Varian/Tomo Log files could be used. review error detection via log file analysis Learn how exit detector signal recorded in log file could be used to improve patient safety understand real-time EPID-based transmission dosimetry methods understand the goals of real-time delivery monitoring CMS Innovation grant. Rapid response supportive and palliative care program for patients with advanced cancer, starts July, 2012; Accuray Inc. Exit detector based QA software evaluation, Sept, 2012-Sept, 2013; ROI GRant from ASTRO “Safety and Quality: IMRT treatment delivery accuracy”.

60 APPLIED LIFE SCIENCES↗

Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-202-02: Real-Time Verification and Error Detection for MLC Tracking Deliveries Using An Electronic Portal Imaging Device

Purpose: The added complexity of the real-time adaptive multi-leaf collimator (MLC) tracking increases the likelihood of undetected MLC delivery errors. In this work we develop and test a system for real-time delivery verification and error detection for MLC tracking radiotherapy using an electronic portal imaging device (EPID). Methods: The delivery verification system relies on acquisition and real-time analysis of transit EPID image frames acquired at 8.41 fps. In-house software was developed to extract the MLC positions from each image frame. Three comparison metrics were used to verify the MLC positions in real-time: (1) field size, (2) field location and, (3) field shape. The delivery verification system was tested for 8 VMAT MLC tracking deliveries (4 prostate and 4 lung) where real patient target motion was reproduced using a Hexamotion motion stage and a Calypso system. Sensitivity and detection delay was quantified for various types of MLC and system errors. Results: For both the prostate and lung test deliveries the MLC-defined field size was measured with an accuracy of 1.25 cm{sup 2} (1 SD). The field location was measured with an accuracy of 0.6 mm and 0.8 mm (1 SD) for lung and prostate respectively. Field location errors (i.e. tracking in wrong direction) with a magnitude of 3 mm were detected within 0.4 s of occurrence in the X direction and 0.8 s in the Y direction. Systematic MLC gap errors were detected as small as 3 mm. The method was not found to be sensitive to random MLC errors and individual MLC calibration errors up to 5 mm. Conclusion: EPID imaging may be used for independent real-time verification of MLC trajectories during MLC tracking deliveries. Thresholds have been determined for error detection and the system has been shown to be sensitive to a range of delivery errors.

60 APPLIED LIFE SCIENCES↗

Systematic softening in universal machine learning interatomic potentials

Machine learning interatomic potentials (MLIPs) have introduced a new paradigm for atomic simulations. Recent advancements have led to universal MLIPs (uMLIPs) that are pre-trained on diverse datasets, providing opportunities for universal force fields and foundational machine learning models. However, their performance in extrapolating to out-of-distribution complex atomic environments remains unclear. In this study, we highlight a consistent potential energy surface (PES) softening effect in three uMLIPs: M3GNet, CHGNet, and MACE-MP-0, which is characterized by energy and force underprediction in atomic-modeling benchmarks including surfaces, defects, solid-solution energetics, ion migration barriers, phonon vibration modes, and general high-energy states. The PES softening behavior originates primarily from the systematically underpredicted PES curvature, which derives from the biased sampling of near-equilibrium atomic arrangements in uMLIP pre-training datasets. Our findings suggest that a considerable fraction of uMLIP errors are highly systematic, and can therefore be efficiently corrected. We argue for the importance of a comprehensive materials dataset with improved PES sampling for next-generation foundational MLIPs.

36 MATERIALS SCIENCE↗

Processing Aleatory and Epistemic Uncertainties in Experimental Data From Sparse Replicate Tests of Stochastic Systems for Real-Space Model Validation

This paper presents a practical methodology for propagating and processing uncertainties associated with random measurement and estimation errors (that vary from test-to-test) and systematic measurement and estimation errors (uncertain but similar from test-to-test) in inputs and outputs of replicate tests to characterize response variability of stochastically varying test units. Also treated are test condition control variability from test-to-test and sampling uncertainty due to limited numbers of replicate tests. These aleatory variabilities and epistemic uncertainties result in uncertainty on computed statistics of output response quantities. The methodology was developed in the context of processing experimental data for “real-space” (RS) model validation comparisons against model-predicted statistics and uncertainty thereof. The methodology is flexible and sufficient for many types of experimental and data uncertainty, offering the most extensive data uncertainty quantification (UQ) treatment of any model validation method the authors are aware of. It handles both interval and probabilistic uncertainty descriptions and can be performed with relatively little computational cost through use of simple and effective dimension- and order-adaptive polynomial response surfaces in a Monte Carlo (MC) uncertainty propagation approach. A key feature of the progressively upgraded response surfaces is that they enable estimation of propagation error contributed by the surrogate model. Sensitivity analysis of the relative contributions of the various uncertainty sources to the total uncertainty of statistical estimates is also presented. Finally, the methodologies are demonstrated on real experimental validation data involving all the mentioned sources and types of error and uncertainty in five replicate tests of pressure vessels heated and pressurized to failure. Simple spreadsheet procedures are used for all processing operations.

97 MATHEMATICS AND COMPUTING↗