Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Operator Insights and Usability Evaluation of Machine Learning Assistance for Power Grid Contingency Analysis

Introducing machine learning (ML) assistance into any established process comes with adoption barriers, including entrenched procedures, technological and human readiness levels, human-machine trust, and work culture resistance to change. These barriers are even greater in critical operations such as operating a national or regional power grid, in which both regulatory frameworks and the importance of maintaining reliability levels causes additional resistance to the adoption of new computational support. Developers of future systems and job aides must consider not only technical aspects, but also whether new systems are usable by power system operators. This work presents the methodology and results of a study to evaluate the usability and readiness of a prototype recommender system for power grid contingency analysis. We explore operator cognitive load and evaluate operator performance when solving a collection of scenarios both with and without recommender assistance. We also examine operator trust in the system. We report insights gained on the readiness of the system using a collection of evaluation techniques.

Human-Machine Teaming, Power Systems, usability ev↗

LDMS New Features for Deployment in Advanced Environments and Feedback for Operations

We describe how LDMS is being used to collect application data concurrent with system data and how the low-latency availability of this data for analysis can be used for real-time data analysis and feedback in order to support efficient, resilient, and reliable system operations. Finally, we will describe current related research areas.

Brandt, James Michael [Sandia National Laboratorie↗

Operational impacts of high penetration solar power on a real-world distribution feeder

Higher penetration of solar photovoltaic (PV), with their uncontrollable generation variability, imposes various grid stability challenges on distribution system operation. The primary problem is significant voltage rise in the distribution feeder that forces existing voltage control devices such as on-load tap-changers and line voltage regulators to operate more frequently. The consequence is the deterioration of the operating life of the voltage control mechanism. The objective of this paper is to investigate the voltage impact of increased penetration of PV systems on distribution load tap changer operations. Both steady-state and quasi-static power flow analyses have been conducted to assess the impact on load tap changes under different solar PV penetration levels. Two real-world distribution feeder circuits are used as a test system in this study. Simulations are carried out for up to one-year period with 1-minute time step using OpenDSS. A comparison study was performed to investigate potential voltage rise issues in the network by increasing total PV penetration from 0 to 100% in the feeder. Results show significant increase in the total number of tap operations as solar PV penetration increases. Impacts on nodal voltages and feeder net power are also presented.

Dong, Jin↗

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance - United States Pacific Command (PACOM) Guam, Task 3.3: Building Retuning Training

Document describes an onsite workshop and building retuning training conducted in Guam in August 2010. Document reports on issues identified during an audit of several buildings and recommendations to save energy throughout the site. During the workshop, it became apparent that as site personnel maintain the facilities at Guam, the following retuning efforts and strategies should be prioritized: (1) Controlling the mechanical systems operational hours and zone temperature set points appeared to present the best opportunities for savings; (2) Zone temperature set points in some buildings are excessively low, especially at night, when the zone temperatures are so cold that they approached the dewpoint; and (3) Manually-set outside air dampers are providing excessive outside air, especially for spaces that are unoccupied. Two of the larger schools, one on the Naval Base and one on Anderson AFB, are in need of a significant recommissioning effort. These facilities are relatively new, with direct digital controls (DDC) but are significantly out of balance. The pressure in one school is extremely negative, which is pulling humid air through the facility each time a door is opened. The draft can be felt several feet down the halls. The pressure in the other school is extremely positive relative to the outside, and you can stand 20-feet outside and still feel cool drafts of air exiting the building. It is recommended that humidity sensors be installed in all new projects and retrofitted into exist facilities. In this humid climate, control of humidity is very important. There are significant periods of time when the mechanical systems in many buildings can be unloaded and dehumidification is not required. The use of CO{sub 2} sensors should also be considered in representative areas. CO{sub 2} sensors determine whether spaces are occupied so that fresh air is only brought into the space when needed. By reducing the amount of outside air brought into the space, the humidity load is also substantially reduced. CO{sub 2} and humidity sensors, combined with outside air sensors, can be used to predict whether conditions are amenable to mold growth and to automatically adjust systems to help prevent mold without using extra energy. The goal of this training is to give the building operators the knowledge needed to make positive changes in the operation of building systems. As class participants apply this knowledge, building systems will run more efficiently, occupant comfort should improve, while saving energy and reducing greenhouse gas emissions.

54 ENVIRONMENTAL SCIENCES↗

Optimization-based technoeconomic comparison of multi-stage membrane distillation configurations for hypersaline produced water desalination

Unconventional oil and gas production raises concerns regarding sustainable management of high salinity wastewaters generated in this process. Membrane distillation (MD) is a thermal desalination process capable of treating hypersaline brines such as produced water. The low single pass recovery in MD systems operated in a single stage requires a large recycle stream to achieve the desired recovery, resulting in high energy consumption and operating cost. Multistage configurations in continuous recirculation operation mode offer the potential to reduce the energy intensity of MD systems. However, rigorous analysis is needed to assess the performance of MD configurations when operating in multi-stage mode. Here, we present an optimization-based comparison of economic and energetic performance for five configurations of MD (including DCMD, AGMD, PGMD, CGMD, and VMD) operating in multi-stage continuous recirculation mode. Our findings demonstrate that multistage operation reduces the treatment cost and energy intensity of all MD configurations compared to single stage MD, with the greatest benefit for VMD and PGMD. AGMD with five stages outperforms other configurations with 3.58 $/m 3 feed treatment cost, followed by VMD, CGMD, DCMD, and PGMD with 3.8, 4.2, 5.4, and 9.06$/m 3 feed treatment costs corresponding to twelve, eight, eight, and sixteen stages, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Total Power Factor Smart Contract with Cyber Grid Guard Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Wind Farm

In modern electrical grids, the numbers of customer-owned distributed energy resources (DERs) have increased, and consequently, so have the numbers of points of common coupling (PCC) between the electrical grid and customer-owned DERs. The disruptive operation of and out-of-tolerance outputs from DERs, especially owned DERs, present a risk to power system operations. A common protective measure is to use relays located at the PCC to isolate poorly behaving or out-of-tolerance DERs from the grid. Ensuring the integrity of the data from these relays at the PCC is vital, and blockchain technology could enhance the security of modern electrical grids by providing an accurate means to translate operational constraints into actions/commands for relays. This study demonstrates an advanced power system application solution using distributed ledger technology (DLT) with smart contracts to manage the relay operation at the PCC. The smart contract defines the allowable total power factor (TPF) of the DER output, and the terms of the smart contract are implemented using DLT with a Cyber Grid Guard (CGG) system for a customer-owned DER (wind farm). This article presents flowcharts for the TPF smart contract implemented by the CGG using DLT. The test scenarios were implemented using a real-time simulator containing a CGG system and relay in-the-loop. The data collected from the CGG system were used to execute the TPF smart contract. The desired TPF limits on the grid-side were between +0.9 and +1.0, and the operation of the breakers in the electrical grid and DER sides was controlled by the relay consistent with the provisions of the smart contract. The events from the real-time simulator, CGG, and relay showed a successful implementation of the TPF smart contract with CGG using DLT, proving the efficacy of this approach in general for implementing electrical grid applications for utilities with connections to customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A review of the potential impacts of climate change on bulk power system planning and operations in the United States

In this paper, climate change might impact various components of the bulk electric power system, including electricity demand; transmission; and thermal, hydropower, wind, and solar generators. Most research in this area quantifies impacts on one or a few components and does not link these impacts to effects on power system planning and operations. Here, we advance the understanding of how climate change might impact the bulk U.S. power system in three ways. First, we synthesize recent research to capture likely component-level impacts of climate change in the United States. Second, given the interconnected nature of the electric power system, we assess how aggregated component-level impacts might affect power system planning and operations. Third, we outline an agenda for future research on climate change impacts on power system planning and operations. Although component-level impacts vary in their magnitude, collectively they might significantly affect planning and operations. Most notably, increased demand plus reduced firm capacity across generation types might require systems to procure significant additional capacity to maintain planning reserve margins, and regional declines in renewable resources might need to be offset by increasing zero-carbon investment to meet decarbonization targets. Aggregated impacts might also affect operations, e.g., through shifts in dispatching and increased operational reserve requirements. Future research should aggregate component-level impacts at operational timescales, quantify impacts on wind and solar variability, and contextualize climate change impacts within ongoing shifts in the electric power system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cyber-Resilient Frequency Control of Power Grids with Energy Storage Systems

The integration of synchronous generators and energy storage systems operated through communication networks introduces new challenges and vulnerabilities to the electric grid, where cyber attacks can corrupt sensor measurements or control inputs and interrupt functions such as frequency regulation. This paper proposes a defense methodology for the design of resilient operating constraints imposed on each generation and storage unit in order to prevent any attack sequence from driving the system's frequency to unsafe conditions. The resilient operating constraints are found by using ellipsoidal approximations of the reachable set of the power system, leading to a convex optimization problem with linear matrix inequalities. Numerical results in a single-area power system with synchronous generation and energy storage demonstrate how the resilient constraints provide security guarantees against any type of attack affecting frequency measurements or controller setpoints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Continuous Flow Liquid Microjunction Surface Sampling Probe Connected On-line with HPLC/MS for Spatially Resolved Analysis of Small Molecules and Proteins

RATIONALE: A continuous flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by MS. Demonstrated here is the on-line coupling of such a probe with HPLC/MS enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. Methods: A continuous flow liquid microjunction surface sampling probe was connected to a 6-port, 2-position valve for extract collection and injection to an HPLC column. A QTRAP 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V ion source operated in positive ESI mode was used for all experiments. System operation was tested with extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues and proteins from dried sheep blood spots on paper. Results: Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s extractions). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin and chains. Conclusions: Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection.

dried blood spots↗

Optimal mitigation and control over power system dynamics for stochastic grid resilience

Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the western system coordinating council 9-bus test system using synthetic multi-device outage scenarios.

30 DIRECT ENERGY CONVERSION↗

SOMAFOAM: An OpenFOAM based solver for continuum simulations of low-temperature plasmas

Here, we report the development of SOMAFOAM, a finite volume framework for performing continuum simulations of low-temperature plasmas. The primary goal of this work is to discuss the features of SOMAFOAM along with representative results provided as examples for a range of operating conditions and geometries. This includes plasma and plasma–dielectric systems operating in direct current, radio frequency, and microwave regimes from pressures as low as 100 mTorr to atmospheric pressure. The code has several useful features including the ability to run massively parallel simulations using arbitrary geometries, structured/unstructured meshes, choice of models such as drift–diffusion/full-momentum at runtime, and species-dependent timesteps to name a few. The verification/validation studies presented include comparison with previously published continuum simulations (low-pressure direct current and radio frequency plasma), with experiments (Gaseous Electronics Conference Reference Cell and microwave microplasma ignited in a split ring resonator), and previously published kinetic simulations (low-pressure radio frequency plasma). Other examples provided include a direct current atmospheric pressure microplasma bounded by dielectric sidewalls and a helium–nitrogen plasma ignited using a needle electrode facing a dielectric. The performance of the code is also discussed with serial and distributed memory parallel runs demonstrated up to 512 cores. The design and implementation of the code in a modular object-oriented framework allows for easy extension and seamless coupling with other codes and can be expected to play an important role in both academia and industry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase I to II cross-induction of xenobiotic metabolizing enzymes: A feedforward control mechanism for potential hormetic responses

Hormetic responses to xenobiotic exposure likely occur as a result of overcompensation by the homeostatic control systems operating in biological organisms. However, the mechanisms underlying overcompensation that leads to hormesis are still unclear. A well-known homeostatic circuit in the cell is the gene induction network comprising phase I, II and III metabolizing enzymes, which are responsible for xenobiotic detoxification, and in many cases, bioactivation. By formulating a differential equation-based computational model, we investigated in this study whether hormesis can arise from the operation of this gene/enzyme network. The model consists of two feedback and one feedforward controls. With the phase I negative feedback control, xenobiotic X activates nuclear receptors to induce cytochrome P450 enzyme, which bioactivates X into a reactive metabolite X'. With the phase II negative feedback control, X' activates transcription factor Nrf2 to induce phase II enzymes such as glutathione S-transferase and glutamate cysteine ligase, etc., which participate in a set of reactions that lead to the metabolism of X' into a less toxic conjugate X''. The feedforward control involves phase I to II cross-induction, in which the parent chemical X can also induce phase II enzymes directly through the nuclear receptor and indirectly through transcriptionally upregulating Nrf2. As a result of the active feedforward control, a steady-state hormetic relationship readily arises between the concentrations of the reactive metabolite X' and the extracellular parent chemical X to which the cell is exposed. The shape of dose-response evolves over time from initially monotonically increasing to J-shaped at the final steady state-a temporal sequence consistent with adaptation-mediated hormesis. The magnitude of the hormetic response is enhanced by increases in the feedforward gain, but attenuated by increases in the bioactivation or phase II feedback loop gains. Our study suggests a possibly common mechanism for the hormetic responses observed with many mutagens/carcinogens whose activities require bioactivation by phase I enzymes. Feedforward control, often operating in combination with negative feedback regulation in a homeostatic system, may be a general control theme responsible for steady-state hormesis.

60 APPLIED LIFE SCIENCES↗

Nuclear-Reaction-Based Radiation Source For Explosives-And SNM-Detection In Massive Cargo

An automatic, nuclear-reaction-based, few-view transmission radiography method and system concept is presented, that will simultaneously detect small, operationally-relevant quantities of chemical explosives and special nuclear materials (SNM) in objects up to the size of LD-3 aviation containers. Detection of all threat materials is performed via the {sup 11}B(d,n+{gamma}) reaction on thick, isotopically-enriched targets; SNM are primarily detected via Dual Discrete-Energy Radiography (DDER), using 15.11 MeV and 4.43 MeV {sup 12}C{gamma}-rays, whereas explosives are primarily detected via Fast Neutron Resonance Radiography (FNRR), employing the broad-energy neutron spectra produced in a thick {sup 11}B-target. To achieve a reasonable throughput of {approx}20 containers per hour, ns-pulsed deuteron beam of the order of 0.5 mA intensity at energies of 5-7 MeV is required. As a first step towards optimizing parameters and sensitivities of an operational system, the 0 deg. spectra and yields of both {gamma}-rays and neutrons in this reaction have been measured up to E{sub d} = 6.65 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Field Measurement and Analysis of Frequency and RoCoF for Low-Inertia Power Systems

The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. Here, the dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

X-Ray Toolkit Mobile (Android)

X-Ray Toolkit Mobile (Android) is a software application for acquiring and processing digital images. The application runs on mobile devices running Android operating systems. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525 SAND2021-1981 O

Harris, JamesZ.↗

Evaluation of Non-electric Market Options for a Light-water Reactor in the Midwest. Light Water Reactor Sustainability program

This study has addressed the technical feasibility and economic viability of LWR hybrid system operations based on realistic market around a specific reactor site in the Upper Midwest United States within the Great Lakes Region and near an industrial center that could benefit from more direct use of nuclear energy. The diverse industrial user and the electricity grid to optimize the revenue of the nuclear plant, depending on specific day-ahead electricity-grid capacity commitments and reserve capacity agreement requirements. For this market arrangement to work, the non-grid user is sold electricity without paying grid service fees (i.e., being considered a house load). This mode of energy sharing may require approval of governing utility commissions, depending on whether the hybrid operations can affect grid supply and manufacturing, agriculture, and transportation systems in this region provides several advantages to converting a nuclear plant into a hybrid plant that produces hydrogen and other feedstock commodities, such as polyethylene or formic acid, for example. Large-scale hydrogen production can essentially service several refineries within 20-30 miles of the nuclear plant. This would results in a measurable reduction of air-pollutant emissions reduction in the region. In addition, a large, consistent supply of hydrogen would draw new industries to the area—especially other steel-reduction and ammonia plants. For example, the nation’s first synthetic-fuels plant could also be sited near this hydrogen plant to convert CO 2 collected from the several ethanol plants in the region into methanol-based chemical feedstock and biofuels. With these perspectives in mind, this study has evaluated the business case for the following hybrid plant options.

08 HYDROGEN↗

Dynamics Informed Optimization for Resilient Energy Systems

Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the Western System Coordinating Council (WSCC) 9-bus test system using synthetic multi-device outage scenarios. Towards integrating our modeling framework with real threats and more realistic power systems, we explore applying hybrid dynamics to power systems. Our work is applied to basic RL circuits with the ultimate goal of using the methodology to model protective tripping schemes in the grid. Finally, we survey mitigation techniques for HEMP threats and describe a GIS application developed to create threat scenarios in a grid with geographic detail.

24 POWER TRANSMISSION AND DISTRIBUTION↗