STARE for scalable unification of diverse data within Earth, Space, and Planetary Science
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.
Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.
The Supper Proton-Proton Collider is a next-generation hadron collider that is now being designed. A baseline design aims for a peak luminosity of about 1*10^35 cm^-2 s^-1. The focus of this article is the effect of beam-beam interactions which are expected to strongly influence stability in the beams. We start with a discussion of a scheme to generate the crossing angles at the interaction points while also correcting the dispersion thus created. The optics constraints on the achievable \b{eta}* were studied. Weak-strong simulations were performed to study single particle dynamics via tune footprints, frequency map analysis and dynamic aperture calculations. The long-range interactions with the smallest separations are shown to determine the dynamic aperture. Empirical scaling laws for the dependence of the dynamic aperture on the transverse separations and on the number of long-range interactions are found. A tune scan shows several alternative working points with slightly better dynamic aperture than the baseline choice. Finally an option to significantly increase the dynamic aperture by increasing the crossing angle for different choices of \b{eta}* was studied.
Classifiers for dissolution events at a radiochemical processing facility are studied using gamma spectra measurements of effluents collected by a high purity germanium detector located at its off-gas stack. Data sets collected at the Oak Ridge National Laboratory’s Radiochemical Engineering Development Center under a Pu dissolution campaign spanning a three months period are utilized. Features corresponding to the activity levels of 15 radionuclides, including isotopes of iodine, krypton, and xenon, that are indicated by the target decay chains, are computed from the spectra at 1 hour intervals. A conceptualization diagram is developed to reflect the steps from the source to measurement to feature computation that depend on fission products indicated by decay chains, chemical processing, and effluents transport to the off-gas stack. A diverse set of eight classifiers based on different design principles are trained using the ground truth data for this campaign, and the outputs of top three classifiers, namely, classification trees, Ensemble of Trees (EOT), and k-nearest neighbor, are combined using EOT classifier-fuser. Our results show that for 5-fold cross validation, features associated with isotopes of xenon provide the lowest classification error among the different elements across the classifiers; the classification error is furthered improved when all 15 isotope features are used by each classifier, and it is again improved by the fusion of three classifiers. Further reduction in classification error is achieved by using a measurement window of 1-2 days which is identified based on half-life time estimates of the isotopes; it is long enough for the stabilization of feature estimates while being short enough not to be affected by the follow on dissolution events. As a net result of feature and classifier fusion, combined with the incorporation of decay chain and isotope half-life information, this approach achieves 98% detection rate while maintaining a false alarm rate under 2% for this data set.
This paper synthesizes a unifying framework that captures a large class of transactive energy systems studied in the literature. The framework consists of four key elements: agent preferences, control decisions, information structure, and solution concept. Among them, agent preference specifies the preferred outcome by each agent and models the conflict of interest in decision making. Control decision specifies the set of decisions for each agent to maximize its payoff. Information structure describes the information available to each agent before it makes a decision. Solution concept encodes the rationality assumptions of each agent in the system. These elements are important in identifying and distinguishing different transactive energy systems. In this paper, we use them to analyze a number of important ones, including the competitive equilibrium, Stackelberg game, reverse Stackelberg game, and mechanism design. Each class of these problems is formulated as a special case of the proposed transactive energy systems. Their connections and differences are discussed. Available tools and results for each category of problems are surveyed.
We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.
ART-GCR “Methods” activity is split between Experimental Validation data from the ANL NSTF and OSU HTTF (next three presentations). HTGR core simulation (this presentation). International collaboration within OECD Generation-IV (Gen-IV) and USA/Japan bi-lateral agreements (this presentation) HTGR Simulation Methods No new NE-52 funding for HTGR Methods support in FY20; ~$200K FY19 carry-over funds only. Consists of international code-to-code benchmarks (IAEA CRP on HTGR UAM and OECD/NEA MHTGR-350) and refinement of a few-group Pebble Bed Reactor (PBR) cross section (XS) generation methodology. Funding will be requested in FY21 to produce the final reports for the two benchmarks and continue the development of the PBR XS generation methodology. Additional (non-ART) HTGR-related support work at INL NEAMS: HTR-Application work package at INL Create a benchmark for the pebble shuffling and depletion algorithms being developed for NEAMS Griffin code. iFOA award with X-Energy: Develop independent Monte Carlo model of Xe-100 design. Independent design confirmatory analysis of Xe-100 design using NEAMS tools Griffin and Pronghorn. Support X-Energy design team to use their own legacy design tools (VSOP99 and MGT). Support NEAMS Griffin and Pronghorn development team for the iFOA needs (received $50K additional funding for required development).
Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.
Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.
In recent years, reinforcement learning (RL) methods have been greatly enhanced by leveraging deep learning approaches. RL methods applied to building control have shown potential in many applications due to their ability to complement or replace conventional methods such as model-based or rule-based controls. However, RL-based building control software is likely tailored either to one target building system or to a specific RL method so that significant additional effort would be required to customize the RL-based controller for use in other building systems or with other RL approaches. Also, RL-based building controls usually depend on building energy simulations to train controllers, so emulating building dynamics (i.e., thermal dynamics and control dynamics) and capturing sub-hourly dynamic profiles are crucial to further the development of effective RL-based building control methods. To address these challenges, we present an open source RL-based control software employing a high-fidelity hybrid EnergyPlus-Modelica building energy model which emulates building dynamics at 1-minute resolution. This software consists of decoupled components (environment, building emulator, control agent, and RL algorithm), which allows for quick prototyping and benchmarking of standard RL algorithms in different systems; for example, a single component can be replaced without revising all of the software. To demonstrate this software framework, we conducted a benchmark study using an EnergyPlus-Modelica building energy model for a Chicago office building with an RL-based controller to dynamically control the chilled water temperature setpoint and the air handling unit supply air temperature setpoint on selected floors.
The US Government currently has no plans to finance or build advanced nuclear reactors. Instead, the DOE performs research and development to raise the technological readiness of new concepts, fuels and component materials so that private industrial partners are more likely to design and build plants. Develop technologies that can enable new concepts and designs to achieve greater levels of safety and resilience, flexibility of use, sustainability and construction or operational affordability. Collaborate with industry to identify and conduct essential research to reduce technical risk associated with advanced reactor technologies. Sustain essential technical expertise and capabilities within national laboratories, universities, and industry to perform needed research. Collaborate with the Nuclear Regulatory Commission and Standards Developing Organizations (ASME, ANS, ANSI, etc.) to address gaps in codes and standards to support advanced reactor designs
The distribution system is going through significant changes. One of them is the high penetration of inverter-based distributed energy resources in the distribution system. Due to this high penetration, there is a need for a better protection system. Multiple organizations are working on creating novel protection techniques for distribution systems with high penetration of inverter-based DERs. One such innovative method is the use of traveling waves to detect and locate faults. Transmission system protection utilizes this approach, and commercial solutions exist for the transmission system. Using this approach in the distribution system is not straightforward and presents some challenges for implementation. This presentation will discuss the need for using wide-band models to model the traveling wave phenomenon in the distribution system.
Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.
Increasingly over the last decade, the management of end-use electricity demand has been examined as a potential source of services for the electric power grid beyond contracts with large commercial and industrial customers. Lighting represents about 17\% of U.S. commercial building annual electricity consumption; however, its potential rapid speed of response may position it to uniquely contribute to services that improve the reliability and resilience of the grid. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change state by adjusting power demand more quickly than most other building electricity end uses and could be used as a platform to monitor lighting electricity use and space conditions. But the potential of CLS to provide grid services has not been extensively studied. In this paper, we describe initial research to evaluate the potential of CLS for grid services. We develop a model for CLS using a set of parameters to represent operation behaviors and constraints: maximal power, minimal power, nominal power, ramp rate, and time delay. Parameter values are generated for representative building types. CLS demand curves are constructed, indirectly capturing building occupant preferences for lighting as functions of electricity price. The CLS model and the demand curves are incorporated into a Transactive Control and Coordination (TCC) Platform to simulate CLS providing grid services. Previous research has shown TCC to be a powerful tool to enable end uses to provide grid services through a hybrid economic-control approach. Initial quantitative results will be provided for CLS grid services potential.
For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.
Legacy inverters interfacing distributed energy re-sources are traditionally grid-following (GFL) in nature. GFL assets typically follow real power and reactive power set points. Recently, inverters with grid-forming (GFM) capability are gaining attention as GFM assets can increase the resiliency of the distribution system under stressed conditions. These GFM inverters can use photovoltaics, batteries, or fuel cells as their energy source. In this paper, we present information on inverters interfacing fuel cell assets, specifically with GFM capability. By introducing a fuel cell powered GFM coupled with hydrogen production and storage, the GFM can continuously provide GFM activities during periods of low renewable resource availability, and/or during power outages exceeding typical electric battery duration. Finally, we present information on the need for updates on interconnection and interoperability standards that can be leveraged by utilities for including fuel cell inverters in their asset mix.
Explore the source record for details and available documents.