Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SINGLE IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Crystal Field Studies on MgGa{sub 2}O{sub 4}:Ni{sup 2+}

The energy levels scheme of octahedrally coordinated Ni{sup 2+} ion in single crystal, powder nano-single crystal, ceramics and glass-ceramics of MgGa{sub 2}O{sub 4} host matrix, has been calculated in the exchange charge model of crystal field. The parameters of the crystal field acting on the Ni{sup 2+} ion are calculated from the crystal structure data, after optimization of the geometry of the system. The energy level schemes have been calculated by diagonalization of the crystal field Hamiltonian of this system. The obtained results were compared with experimental data; a good agreement were demonstrated, which confirm the validity of the model and used method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The ReA electron-beam ion trap charge breeder for reacceleration of rare isotopes

ReA is a post-accelerator at the National Superconducting Cyclotron Laboratory at Michigan State University. ReA is designed to reaccelerate rare isotopes to energies of a few MeV/u following production by projectile fragmentation and thermalization in a gas cell. The facility consists of four main components: an electron-beam ion trap (EBIT) charge breeder, an achromatic charge-over-mass (Q/A) separator, a radio-frequency quadrupole accelerator, and a superconducting radio-frequency linear accelerator. The EBIT charge breeder was specifically designed to efficiently capture continuous beams of singly charged ions injected at low energy (<60 keV), charge breed in less than 50 ms, and extract highly charged ions to the Q/A separator for charge-state selection and reacceleration through the accelerator structures. The use of highly charged ions to reach high beam energies is a key aspect that makes ReA a compact and cost-efficient post-accelerator. The EBIT is characterized by a high-current electron gun, a long multi-electrode trap structure and a dual magnet to provide both the high electron-beam current density necessary for fast charge breeding of short-lived isotopes as well as the high capture probability of injected beams. This paper presents an overview and the status of the ReA EBIT, which has extracted for reacceleration tests stable {sup 20}Ne{sup 8+} ion beams produced from injected gas and more recently {sup 39}K{sup 16+} beams by injecting stable {sup 39,41}K{sup +} ions from an external ion source.

43 PARTICLE ACCELERATORS↗

Temporal evolution of ion energy distribution functions and ion charge states of Cr and Cr-Al pulsed arc plasmas

To study the temporal evolution of ion energy distribution functions, charge-state-resolved ion energy distribution functions of pulsed arc plasmas from Cr and Cr-Al cathodes were recorded with high time resolution by using direct data acquisition from a combined energy and mass analyzer. The authors find increases in intensities of singly charged ions, which is evidence that charge exchange reactions took place in both Cr and Cr-Al systems. In Cr-Al plasmas, the distributions of high-charge-state ions exhibit high energy tails 50 μs after discharge ignition, but no such tails were observed at 500 μs. The energy ratios of ions of different charge states at the beginning of the pulse, when less neutral atoms were in the space in front of the cathode, suggest that ions are accelerated by an electric field. The situation is not so clear after 50 μs due to particle collisions. The initial mean ion charge state of Cr was about the same in Cr and in Cr-Al plasmas, but it decreased more rapidly in Cr-Al plasmas compared to the decay in Cr plasma. The faster decay of the mean ion charge state and ion energy caused by the addition of Al into a pure Cr cathode suggests that the mean ion charge state is determined not only by ionization processes at the cathode spot but also by inelastic collision between different elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy ions in space (M0001)

The ojectives are to investigate three components of heavy nuclei in space: (1) a recently observed anomalous component of low-energy nuclei of N, O, and Ne; (2) the heavy nuclei in the Van Allen radiation belts; and (3) the UH nuclei (Z 30) of the galactic radiation. The study of the anomalous flux of N, O, and Ne nuclei in the unexplored energy region above 100 MeV/u is expected to provide new insights into the source of this component. Its observation in this experiment will confirm that these ions are singly charged. Knowledge of the energy spectra of the heavy nuclei observed in the Van Allen belts is expected to enhance the understanding of the origin of the belts (e.g., injection and local acceleration pocesses). The observation of these heavy ions could show, for the first time, that low-energy particles of extraterrestrial origin can diffuse to the innermost parts of the magnetosphere. Measurements of the UH component are expected to contribute information concerning its source, interstellar propagation, and the galactic storage time.

Adams, J. H., Jr.↗

Effect of swift heavy ion irradiation on optical absorption properties of SWCNTs

In the present work, experimental investigations on the optical absorption properties of swift heavy ion irradiated single walled carbon nanotubes (SWCNTs) have been carried out. The uniform thin films of SWCNTs have been deposited on quartz substrate by Langmuir Blodgett (LB) method in a layer by layer manner. The irradiation of thin films is carried out by nickel ion beam of energy 60 MeV at different fluences. The variation in the S{sub 11}, S{sub 22}, and M{sub 11} band in optical spectra of SWCNTs has been studied before and after irradiation. The decrease in intensity/area of the bands corresponding to both semiconducting and metallic SWCNTs has been observed with increasing fluence.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Neutral but Impactful: Gallium Cluster-Induced Nanopores from Beam-Blanked Gallium Ion Sources

Neutral atoms originating from liquid metal ion sources are an often-overlooked source of contamination and damage in focused ion beam microscopy. Beyond ions and single atoms, these sources also generate atom clusters. While most studies have investigated charged clusters, here we demonstrate that neutral clusters are also formed. These neutral clusters bypass the electrostatic beam blanking system, allowing them to impinge on samples even when the ion beam is blanked. We investigate this phenomenon using thin (≤20 nm) freestanding membranes of hexagonal boron nitride, silicon, and silicon nitride as targets. Randomly dispersed nanopores that form upon neutral cluster exposure are revealed. The average nanopore diameter is ∼2 nm with a narrow size distribution, suggesting that the atom clusters have a preferred size. Various electron microscopy techniques are used to characterize the nanopores, including high-resolution transmission electron microscopy, multislice ptychography, and electron energy-loss spectroscopy. Finally, we show how electron irradiation in the transmission electron microscope can be used to both remove any amorphous material that may clog the pores and to controllably grow the pores to specific sizes. Tunable nanopores such as these are interesting for nanofluidic applications requiring size-selective membranes.

Byrne, Dana O↗

Equilibration of the planar modes of ultracold two-dimensional ion crystals in a Penning trap

In this work, planar thermal equilibration is studied using direct numerical simulations of ultracold two-dimensional ion crystals in a Penning trap with a rotating wall. The large magnetic field of the trap splits the modes that describe in-plane motion of the ions into two branches: high-frequency cyclotron modes dominated by kinetic energy and low-frequency E × B modes dominated by potential energy associated with thermal position displacements. Using an eigenmode analysis we extract the equilibration rate between these two branches as a function of the ratio of the frequencies that characterize the two branches and observe this equilibration rate to be exponentially suppressed as the ratio increases. Under experimental conditions relevant for current work at NIST, the predicted equilibration time is orders of magnitude longer than any relevant experimental timescales. We also study the coupling rate dependence on the initial energy of the planar modes and the number of ions. In addition, we show how increasing the rotating wall strength improves crystal stability. These details of in-plane mode dynamics help set the stage for developing strategies to efficiently cool the in-plane modes and improve the performance of single plane ion crystals for quantum information processing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculations for Calibration of a Mass Spectrometer

A computer program performs calculations to calibrate a quadrupole mass spectrometer in an instrumentation system for identifying trace amounts of organic chemicals in air. In the operation of the mass spectrometer, the mass-to-charge ratio (m/z) of ions being counted at a given instant of time is a function of the instantaneous value of a repeating ramp voltage waveform applied to electrodes. The count rate as a function of time can be converted to an m/z spectrum (equivalent to a mass spectrum for singly charged ions), provided that a calibration of m/z is available. The present computer program can perform the calibration in either or both of two ways: (1) Following a data-based approach, it can utilize the count-rate peaks and the times thereof measured when fed with air containing known organic compounds. (2) It can utilize a theoretical proportionality between the instantaneous m/z and the instantaneous value of an oscillating applied voltage. The program can also estimate the error of the calibration performed by the data-based approach. If calibrations are performed in both ways, then the results can be compared to obtain further estimates of errors.

Lee, Seungwon↗

Shell Model for Atomistic Simulation of Lithium Diffusion in Mixed Mn/Ti Oxides

Mixed Mn/Ti oxides present attractive physicochemical properties such as their ability to accommodate Li for application in Li-ion batteries. In this work, atomic parameters for Mn were developed to extend an existing shell model of the Li-Ti-O system and allow simulations of pure and lithiated Mn and mixed Mn/Ti oxide polymorphs. The shell model yielded good agreement with experimentally-derived structures (i.e. lattice parameters and inter-atomic distances) and represented an improvement over existing potential models. The shell model was employed in molecular dynamics (MD) simulations of Li diffusion in the 1×1 c direction channels of LixMn1 yTiyO2 with the rutile structure, where 0 ≤ x ≤ 0.25 and 0 ≤ y ≤ 1. In the infinite dilution limit, the arrangement of Mn and Ti ions in the lattice was found to have a significant effect on the activation energy for Li diffusion in the c channels due to the destabilization of half of the interstitial octahedral sites. Anomalous diffusion was demonstrated for Li concentrations as low as x = 0.125, with a single Li ion positioned in every other c channel. Further increase in Li concentration showed not only the substantial effect of Li-Li repulsive interactions on Li mobility but also their influence on the time dependence of Li diffusion. The results of the MD simulations can inform intrinsic structure-property relationships for the rational design of improved electrode materials for Li-ion batteries.

Environmental Molecular Sciences Laboratory↗

Multiple species beam production on laser ion source for electron beam ion source in Brookhaven National Laboratory

Extracted ion beams from the test laser ion source (LIS) were transported through a test beam transport line which is almost identical to the actual primary beam transport in the current electron beam ion source apparatus. The tested species were C, Al, Si, Cr, Fe, Cu, Ag, Ta, and Au. The all measured beam currents fulfilled the requirements. However, in the case of light mass ions, the recorded emittance shapes have larger aberrations and the RMS values are higher than 0.06 π mm mrad, which is the design goal. Since we have margin to enhance the beam current, if we then allow some beam losses at the injection point, the number of the single charged ions within the acceptance can be supplied. For heaver ions like Ag, Ta, and Au, the LIS showed very good performance.

43 PARTICLE ACCELERATORS↗

Fine-Tuning the Activity of Metal–Organic Framework Supported Cobalt Catalysts for the Oxidative Dehydrogenation of Propane

Few-atom cobalt-oxide clusters, when dispersed on a Zr-based metal–organic framework (MOF) NU-1000, have previously been shown to be active for the oxidative dehydrogenation (ODH) of propane at low temperatures (< 230 °C), affording a selective and stable propene production catalyst. In our current work, a series of promoter ions with varying Lewis acidity, including Ni(II), Zn(II), Al(III), Ti(IV) and Mo(VI), are anchored as metal-oxide,hydroxide clusters to NU-1000 via SIM (solvothermal deposition within MOFs–specifically the nodes) followed by incorporation of Co(II) ions via vapor-phase AIM (atomic layer deposition (ALD) in MOFs). This process yields a series of NU-1000-supported bimetallic-oxo,hydroxo,aqua clusters. Using difference envelope density (DED) analyses, the spatial locations of the promoter ions and catalytic cobalt ions are determined. For all samples the SIM-anchored promoter ions are sited between pairs of Zr 6 nodes along the MOF c-axis (channel-aligned axis) whereas the location of the AIM-anchored cobalt ions varies depending on the identity of promoter metal ion. With Ni(II)-, Al(III)-, or Ti(IV)-containing clusters as promoters, the oxy-cobalt species are sited atop the promoter sites; with Mo(VI) they grow exclusively on the MOF nodes sites (hexa-Zr(IV)- oxo,hydroxo,aqua units); with Zn(II) they grow on both the node and promoter. The NU-1000- supported bimetallic-oxide clusters are active for propane ODH after thermal activation under O 2 to open a cobalt coordination site and to oxidize Co(II) to Co(III), as evidenced by operando Xray absorption spectroscopy at the Co K-edge. The cobalt component is exclusively responsible for the observed catalysis. In accord with the decreasing Lewis acidity of the promoter ion, catalytic activity increases in the order: Mo(VI)<Ti(IV)<Al(III)<Zn(II)<Ni(II). The finding is attributed to increasing ease of formation Co(III)-O• species and stabilization of a cobalt(III)- oxyl/propane transition state as the Lewis acidity of the promoter ions decreases. (The promoterfree catalyst is sited on the oxy-Zr(IV) node of the MOF and is inferior catalytically to the strongly promoted versions of the catalyst.) The relative Lewis acidities of the promoters are inferred from the initial pKa values of aqua complexes of the corresponding single metal ions. Departures from the (ODH-rate)/(promoter-pKa) correlation are paralleled by differences in cobalt catalyst siting or structure. The combined results point to an increasing ability to fine-tune, with close to atomic specificity, the structure-dependent activity of MOF-supported heterogeneous catalysts for gas phase chemical reactions. When coupled with mechanistic studies–computational or experimental–this ability may translate into informed prediction of improved catalysts for propane ODH and other chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single Atom as a Mirror of an Optical Cavity

By tightly focusing a laser field onto a single cold ion trapped in front of a far-distant dielectric mirror, we could observe a quantum electrodynamic effect whereby the ion behaves as the optical mirror of a Fabry-Perot cavity. We show that the amplitude of the laser field is significantly altered due to a modification of the electromagnetic mode structure around the atom in a novel regime in which the laser intensity is already changed by the atom alone. We propose a direct application of this system as a quantum memory for single photons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of ion beam from laser ion source for RHIC EBIS.

Laser ion source (LIS) is a candidate of the primary ion source for the RHIC EBIS. LIS will provide intense charge state 1+ ions to the EBIS for further ionization. We measured plasma properties of a variety of atomic species from C to Au using the second harmonics of Nd:YAG laser (532 nm wave length, up to 0.5 J/6 ns). Since properties of laser produced plasma is different from different species, laser power density for singly charged ion production should be verified experimentally for each atomic species. After plasma analysis experiments, Au ions was extracted from plasma and emittance of the ion beam was measured using a pepper pot type emittance monitor.

43 PARTICLE ACCELERATORS↗

Thermodynamic and kinetic properties of layered-CaCo2O4 for the Ca-ion batteries: a systematic first-principles study

One of the more promising directions in multivalent energy storage is systems based on Ca ion intercalation due to the potential for high voltage and capacity. A major challenge for enabling such a battery is to find cathode materials capable of fast ionic diffusion and reversible insertion of Ca ions. Here, on the basis of first-principles calculations, we have demonstrated that layered CaCo 2 O 4 exhibits favorable thermodynamic and kinetic properties that should enable topotactic Ca ion intercalation reactions. The P3-type layered Ca x Co 2 O 4 (0 < x < 1) with either of space groups of P 1 or P 2 1 / m are stable at multiple Ca concentrations and show a smooth voltage plateau higher than 3 V up to X = 0.5. The energy barriers of the single Ca ion migration are as low as 0.36 eV and 0.27 eV at the dilute and high vacancy concentration limits, respectively. Therefore, although varying the vacancy environments of the diffusing atom influences the migration barriers, they do not exceed 0.6 eV. Stochastic analysis of Ca hopping events performed by ab initio molecular dynamics (AIMD) simulation has shown that the migration barriers are lower than 0.32 eV. Therefore, the Ca diffusivity at room temperature extrapolated from the AIMD results is comparable to Li diffusivity (>10 -10 cm 2 s -1 ) in conventional Li cathode materials, suggesting the feasibility of layered Ca x Co 2 O 4 as multivalent cathode materials. Finally, the structural factors that enable fast diffusion are discussed.

25 ENERGY STORAGE↗

NSTAR Ion Thruster Plume Impact Assessments

Tests were performed to establish 30-cm ion thruster plume impacts, including plume characterizations via near and farfield ion current measurements, contamination, and sputtering assessments. Current density measurements show that 95% of the beam was enclosed within a 22 deg half-angle and that the thrust vector shifted by less than 0.3 deg during throttling from 2.3 to 0.5 kW. The beam flatness parameter was found to be 0.47, and the ratio of doubly charged to singly charged ion current density decreased from 15% at 2.3 kW to 5% at 0.5 kW. Quartz sample erosion measurements showed that the samples eroded at a rate of between 11 and 13 pm/khr at 25 deg from the thruster axis, and that the rate dropped by a factor of four at 40 deg. Good agreement was obtained between extrapolated current densities and those calculated from tantalum target erosion measurements. Quartz crystal microbalance and witness plate measurements showed that ion beam sputtering of the tank resulted in a facility material backflux rate of -10 A/hr in a large space simulation chamber.

Myers, Roger M.↗

A Dual Source Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer of ExoMars 2018

We present details on the objectives, requirements, design and operational approach of the core mass spectrometer of the Mars Organic Molecule Analyzer (MOMA) investigation on the 2018 ExoMars mission. The MOMA mass spectrometer enables the investigation to fulfill its objective of analyzing the chemical composition of organic compounds in solid samples obtained from the near surface of Mars. Two methods of ionization are realized, associated with different modes of MOMA operation, in a single compact ion trap mass spectrometer. The stringent mass and power constraints of the mission have led to features such as low voltage and low frequency RF operation [1] and pulse counting detection.

Brickerhoff, William B.↗

Changes in electric field noise due to thermal transformation of a surface ion trap

Here, we aim to illuminate how the microscopic properties of a metal surface map to its electric field noise characteristics. In our system, prolonged heat treatments of a metal film can induce a rise in the magnitude of the electric field noise generated by the surface of that film. We refer to this heat-induced rise in noise magnitude as a thermal transformation. The underlying physics of this thermal transformation process is explored through a series of heating, milling, and electron treatments performed on a single surface ion trap. Between these treatments, 40 Ca + ions trapped 70 μm above the surface of the metal are used as detectors to monitor the electric field noise at frequencies close to 1 MHz. An Auger spectrometer is used to track changes in the composition of the contaminated metal surface. With these tools we investigate contaminant deposition, chemical reactions, and atomic restructuring as possible drivers of thermal transformations.

36 MATERIALS SCIENCE↗