Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Cryogenic CMOS circuits for single charge digital readout.

The readout of a solid state qubit often relies on single charge sensitive electrometry. However the combination of fast and accurate measurements is non trivial due to large RC time constants due to the electrometers resistance and shunt capacitance from wires between the cold stage and room temperature. Currently fast sensitive measurements are accomplished through rf reflectrometry. I will present an alternative single charge readout technique based on cryogenic CMOS circuits in hopes to improve speed, signal-to-noise, power consumption and simplicity in implementation. The readout circuit is based on a current comparator where changes in current from an electrometer will trigger a digital output. These circuits were fabricated using Sandia's 0.35 {micro}m CMOS foundry process. Initial measurements of comparators with an addition a current amplifier have displayed current sensitivities of < 1nA at 4.2K, switching speeds up to {approx}120ns, while consuming {approx}10 {micro}W. I will also discuss an investigation of noise characterization of our CMOS process in hopes to obtain a better understanding of the ultimate limit in signal to noise performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Weighted slit extraction of low-dispersion IUE spectral data

The weighted slit extraction has been chosen by the IUE project as the standard extraction for low-dispersion spectra in the final IUE archives. In order to properly weight the data within the extraction slit and obtain the optimal evaluation of the true spectrum, a noise model is derived for IUE data. The exclusion of cosmic rays is demonstrated and the improvement in signal-to-noise ratio is quantified for spectra taken with a wide range of flux level. Problematic spectra, such as trailed spectra, multiple spectra, discontinuous spectra, and emission-line spectra, are extracted to demonstrate the robust nature of the method. Comparisons are made between the standard IUE Standard Image Processing System (IUESIPS) extraction, nonstandard narrow slit extraction, trailed IUESIPS extraction, and weighted extraction for these data. Other weighted slit extractions are briefly discussed. The advantages of the weighted slit extraction are: (1) the extraction improves the signal-to-noise ratio of the spectrum while conserving total flux; (2) most of the cosmic rays are automatically removed; (3) the output includes an error estimate for each point in the flux spectrum; and (4) the algorithm can be run in a batch mode that requires no special input parameters.

Kinney, A. L.↗

Non parametric denoising methods based on wavelets: Application to electron microscopy images in low exposure time

The 3D reconstruction of the Cryo-Transmission Electron Microscopy (Cryo-TEM) and Energy Filtering TEM images (EFTEM) hampered by the noisy nature of these images, so that their alignment becomes so difficult. This noise refers to the collision between the frozen hydrated biological samples and the electrons beam, where the specimen is exposed to the radiation with a high exposure time. This sensitivity to the electrons beam led specialists to obtain the specimen projection images at very low exposure time, which resulting the emergence of a new problem, an extremely low signal-to-noise ratio (SNR). This paper investigates the problem of TEM images denoising when they are acquired at very low exposure time. So, our main objective is to enhance the quality of TEM images to improve the alignment process which will in turn improve the three dimensional tomography reconstructions. We have done multiple tests on special TEM images acquired at different exposure time 0.5s, 0.2s, 0.1s and 1s (i.e. with different values of SNR)) and equipped by Golding beads for helping us in the assessment step. We herein, propose a structure to combine multiple noisy copies of the TEM images. The structure is based on four different denoising methods, to combine the multiple noisy TEM images copies. Namely, the four different methods are Soft, the Hard as Wavelet-Thresholding methods, Bilateral Filter as a non-linear technique able to maintain the edges neatly, and the Bayesian approach in the wavelet domain, in which context modeling is used to estimate the parameter for each coefficient. To ensure getting a high signal-to-noise ratio, we have guaranteed that we are using the appropriate wavelet family at the appropriate level. So we have chosen âĂIJsym8âĂİ wavelet at level 3 as the most appropriate parameter. Whereas, for the bilateral filtering many tests are done in order to determine the proper filter parameters represented by the size of the filter, the range parameter and the spatial parameter respectively. The experiments reported in this paper demonstrate the performance of the Bilateral Filtering and the Bayesian approaches in terms of improving the SNRout and the image quality. Taken together, these results suggest that the Bayesian process has a potential to outperform all the used methods, where in the multiple noisy copies structure it gave us the best SNRout without change of the golden beads diameter. The Bayesian approach yielded enhanced average image without needing a huge amount of copies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of collective Thomson scattering system using 77 GHz gyrotron for bulk and tail ion diagnostics in the large helical device

Collective Thomson scattering (CTS) system is expected to be a strong diagnostic tool for measuring thermal and fast ion distribution function at a local point inside plasmas. The electron cyclotron resonance heating system using a gyrotron at the frequency range of 77 GHz has been installed at the large helical device (LHD). The feasibility of CTS system using the 77 GHz gyrotron is assessed in terms of scattering spectrum and a background noise of the electron cyclotron emission, which affect the signal to noise ratio, with the realistic plasma parameters and incident port locations of LHD. Based on the calculated scattering spectra for bulk and tail fast ion diagnostics, the scattering radiation receiver system with gyrotron frequency feedback circuit is proposed to avoid the frequency chirping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of a Decision-Directed Receiver with Unknown Priors

A decision-directed receiver (DDR) uses previous outputs (decisions) to estimate unknown parameters and, on the basis of these estimates, modifies the detector structure for subsequent decisions. Although the DDR is less complex to instrument than other adaptive schemes, inherent in the decision-directed approach is the possibility of a runaway. This occurs when the detector commits a sequence of decision errors resulting in a degradation of parameter estimates, which, in turn, results in a further deterioration of detector performance. Because of the dependencies introduced by the learning process, runaway is difficult to analyze. In this paper, a DDR with unknown a priori probabilities is considered. The priors are estimated by the relative frequency of decisions of that event. For binary detection, it is shown that there is a positive probability of a runaway (the estimates converge to 1 or 0), which equals 1 if the signal-to-noise ratio is below a critical value. A tight bound on the probability of a runaway is obtained by approximating the learning process by a random walk with independent increments. The analysis demonstrates that a runaway is quite improbable even for moderate signal-to-noise ratios. The analysis is extended to multiple signals and to the situation where the estimates of the priors are updated continuously through exponential weighting rather than allowed to converge.

Davisson, Lee D.↗

Sci—Thur PM: Imaging — 01: Position-sensitive noise characteristics in multi-pinhole cardiac SPECT imaging

Myocardial perfusion imaging (MPI) with Single Photon Emission Computed Tomography (SPECT) is invaluable in the diagnosis and management of heart disease. It provides essential information on myocardial blood flow and ischemia. Multi-pinhole dedicated cardiac-SPECT cameras offer improved count sensitivity, and spatial and energy resolutions over parallel-hole camera designs however variable sensitivity across the field-of-view (FOV) can lead to position-dependent noise variations. Since MPI evaluates differences in the signal-to-noise ratio, noise variations in the camera could significantly impact the sensitivity of the test for ischemia. We evaluated the noise characteristics of GE Healthcare's Discovery NM530c camera with a goal of optimizing the accuracy of our patient assessment and thereby improving outcomes. Theoretical sensitivity maps of the camera FOV, including attenuation effects, were estimated analytically based on the distance and angle between the spatial position of a given voxel and each pinhole. The standard deviation in counts, σ was inferred for each voxel position from the square root of the sensitivity mapped at that position. Noise was measured experimentally from repeated (N=16) acquisitions of a uniform spherical Tc-99m-water phantom. The mean (μ) and standard deviation (σ) were calculated for each voxel position in the reconstructed FOV. Noise increased ∼2.1× across a 12 cm sphere. A correlation of 0.53 is seen when experimental noise is compared with theory suggesting that ∼53% of the noise is attributed to the combined effects of attenuation and the multi-pinhole geometry. Further investigations are warranted to determine the clinical impact of the position-dependent noise variation.

60 APPLIED LIFE SCIENCES↗

Detection of the Pairwise Kinematic Sunyaev-Zel'dovich Effect with BOSS DR11 and the Atacama Cosmology Telescope

We present a new measurement of the kinematic Sunyaev-Zel'dovich effect using data from the Atacama Cosmology Telescope (ACT) and the Baryon Oscillation Spectroscopic Survey (BOSS). Using 600 square degrees of overlapping sky area, we evaluate the mean pairwise baryon momentum associated with the positions of 50,000 bright galaxies in the BOSS DR11 Large Scale Structure catalog. A non-zero signal arises from the large-scale motions of halos containing the sample galaxies. The data fits an analytical signal model well, with the optical depth to microwave photon scattering as a free parameter determining the overall signal amplitude. We estimate the covariance matrix of the mean pairwise momentum as a function of galaxy separation, using microwave sky simulations, jackknife evaluation, and bootstrap estimates. The most conservative simulation-based errors give signal-to-noise estimates between 3.6 and 4.1 for varying galaxy luminosity cuts. We discuss how the other error determinations can lead to higher signal-to-noise values, and consider the impact of several possible systematic errors. Estimates of the optical depth from the average thermal Sunyaev-Zel'dovich signal at the sample galaxy positions are broadly consistent with those obtained from the mean pairwise momentum signal.

De Bernardis, F.↗

Phasing the antennas of the Very Large Array (VLA) for reception of telemetry from Voyager 2 at Neptune encounter

The Very Large Array (VLA) radio telescope is being instrumented at 8.4 GHz to receive telemetry from Voyager 2 during its encounter with Neptune in 1989. The procedure in which the 27 antennas have their phases adjusted in near real time so that the signals from the individual elements of the array can be added coherently is examined. Calculations of the expected signal to noise ratio, tests of the autophasing process at the VLA, and off-line simulations of that process are all presented. Various possible procedures for adjusting the phases are considered. It is shown that the signal to noise ratio at the VLA is adequate for summing the signals from the individual antennas with less than 0.1 dB of loss caused by imperfect coherence among the antennas. Tropospheric variations during the summer of 1989 could cause enough loss of coherence to make the losses higher than 0.1 dB. Experiments show that the losses caused by the troposphere can probably be kept below 0.2 dB if the time delay inherent in the phase adjustment process is no longer than approx. 5 secs. This relatively small combining loss meets the goal estabished to minimize the bit error rate in the Voyager telemetry and implies adequate autophasing of the VLA.

Ulvestad, J. S.↗

Lock detection in Costas loops

Previous analyses of lock detector algorithms for Costas loops have ignored the effects of the inherent correlation between samples of the phase error process. In this paper, both analysis and simulations are used to quantify the effects of phase correlation on lock detection for the 'square law' and 'absolute value' type detectors. Results are obtained which depict the lock detection probability as a function of loop signal-to-noise ratio for a given false alarm rate. It is shown that the square law detector experiences less degradation due to phase jitter than the absolute value detector and that the degradation in detector signal-to-noise ratio is more pronounced for squarewave than for sinewave signals.

Mileant, A.↗

Adaptive low-bandwidth tracking of Galileo and Pioneer 10 carriers

In the Deep Space Network, tracking of residual carrier phase typically occurs with a fixed-bandwidth phase-locked loop using a bandwidth sufficiently wide to prevent loss of lock under worst-case conditions of signal dynamics, received signal phase noise, and receiver phase noise. Much of the time, however, such a high bandwidth is not required and may inflict unnecessarily heavy penalties on loop signal-to-noise ratios. This article describes a technique for improving tracking performance by permitting initial tracking at narrow bandwidths and gradually widening the loop as needed. The cost is a requirement for signal buffering, which is relatively inexpensive for low data rate applications. Results based on off-line processing of recorded carrier data from Galileo and Pioneer 10 are presented, and show potential 10-16 dB gains in loop SNR over worst-case fixed-bandwidth tracking.

Watola, D. A.↗

Development of a new approach based on midwave infrared spectroscopy for post-consumer black plastic waste sorting in the recycling industry

Highlights: • MWIR reflectance contact measurements were performed on post-consumer waste. • MWIR absorptions are found to be potentially suitable for black plastic resin classification. • MWIR is also potentially suitable for separation of coloured plastic and wood based products. • Atmospheric transmittance simulations suggest feasibility of stand-off measurements. - Abstract: Waste sorting is key to the process of waste recycling. Exact identification of plastic resin and wood products using Near Infrared (NIR, 1–1.7 µm) sensing is currently in use. Yet, dark targets characterized by low reflectance, such as black plastics, are hard to identify by this method. Following the recent success of Midwave Infrared (MWIR, 3–12 µm) measurements to identify coloured plastic polymers, the aim of this study was to assess whether this technique is applicable to sorting black plastic polymers and wood products. We performed infrared reflectance contact measurements of 234 plastic samples and 29 samples of wood and paper products. Plastic samples included black, coloured and transparent Polyethylene Terephthalate (PET), Polyethylene (PE), Polyvinyl Chloride (PVC), Polypropylene (PP), Polylactic acid (PLA) and Polystyrene (PS). The spectral signatures of the black and coloured plastic samples were compared with clear plastic samples and signatures documented in the literature to identify the polymer spectral features in the presence of coloured material. This information was used to determine the spectral bands that best suit the sorting of black plastic polymers. The main NIR-MWIR absorption features of wood, cardboard and paper were identified as well according to the spectral measurements. Good agreement was found between our measurements and the absorption features documented in the literature. The new approach using MWIR spectral features appears to be useful for black plastics as it overcomes some of the limitations in the NIR region to identify them. The main limitation of this technique for industrial applications is the trade-off between the signal-to-noise ratio of the sensor operating in standoff mode and the speed at which waste is moved under the sensor. This limitation can be resolved by reducing the system’s spectral resolution to 16 cm{sup −1}, which allows for faster spectra acquisition while maintaining a reasonable signal-to-noise ratio.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The SDSS-IV extended baryon oscillation spectroscopic survey: Luminous red galaxy target selection

Here, we describe the algorithm used to select the luminous red galaxy (LRG) sample for the extended Baryon Oscillation Spectroscopic Survey (eBOSS) of the Sloan Digital Sky Survey IV (SDSS-IV) using photometric data from both the SDSS and the Wide-field Infrared Survey Explorer. LRG targets are required to meet a set of color selection criteria and have z-band and i-band MODEL magnitudes z < 19.95 and 19.9 < i < 21.8, respectively. Our algorithm selects roughly 50 LRG targets per square degree, the great majority of which lie in the redshift range 0.6 < z < 1.0 (median redshift 0.71). We also demonstrate that our methods are highly effective at eliminating stellar contamination and lower-redshift galaxies. We perform a number of tests using spectroscopic data from SDSS-III/BOSS ancillary programs to determine the redshift reliability of our target selection and its ability to meet the science requirements of eBOSS. The SDSS spectra are of high enough signal-to-noise ratio that at least ~89% of the target sample yields secure redshift measurements. Finally, we present tests of the uniformity and homogeneity of the sample, demonstrating that it should be clean enough for studies of the large-scale structure of the universe at higher redshifts than SDSS-III/BOSS LRGs reached.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlinear interference noise in 100-Gbit s{sup -1} communication lines with the DP-QPSK modulation format

The nonlinear interference noise power was measured experimentally as a function of the signal power and the length of the fibre coherent 100-Gbit s{sup -1} communication line, in which chromatic dispersion is not optically compensated. An expression was derived for the optimal signal power corresponding to a maximal excess of the measured optical signal-to-noise ratio (OSNR) over the OSNR required for conditionally error-free operation. The dependence of signal optimal power measured experimentally well agrees with the theoretical formula derived. (optical information transmission)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applying Bayesian inference and deterministic anisotropy to retrieve the molecular structure ∣Ψ(R)∣2 distribution from gas-phase diffraction experiments

Abstract Currently, our general approach to retrieving molecular structures from ultrafast gas-phase diffraction heavily relies on complex ab initio electronic or vibrational excited state simulations to make conclusive interpretations. Without such simulations, inverting this measurement for the structural probability distribution is typically intractable. This creates a so-called inverse problem. Here we address this inverse problem by developing a broadly applicable method that approximates the molecular frame structure ∣Ψ( R , t )∣ 2 distribution independent of these complex simulations. We retrieve the vibronic ground state ∣Ψ( R )∣ 2 for both simulated stretched NO 2 and measured N 2 O. From measured N 2 O, we observe 40 mÅ coordinate-space resolution from 3.75 Å −1 reciprocal space range and poor signal-to-noise, a 50X improvement over traditional Fourier transform methods. In simulated NO 2 diffraction experiments, typical to high signal-to-noise levels predict 100–1000X resolution improvements, down to 0.1 mÅ. By directly measuring the width of ∣Ψ( R )∣ 2 , we open ultrafast gas-phase diffraction capabilities to measurements beyond current analysis approaches. This method has the potential to effectively turn gas-phase ultrafast diffraction into a discovery-oriented technique to probe systems that are prohibitively difficult to simulate.

74 ATOMIC AND MOLECULAR PHYSICS↗

Research and Development of Automated Eddy Current Testing for Composite Overwrapped Pressure Vessels

Eddy current testing (ET) was used to scan bare metallic liners used in the fabrication of composite overwrapped pressure vessels (COPVs) for flaws which could result in premature failure of the vessel. The main goal of the project was to make improvements in the areas of scan signal to noise ratio, sensitivity of flaw detection, and estimation of flaw dimensions. Scan settings were optimized resulting in an increased signal to noise ratio. Previously undiscovered flaw indications were observed and investigated. Threshold criteria were determined for the system software's flaw report and estimation of flaw dimensions were brought to an acceptable level of accuracy. Computer algorithms were written to import data for filtering and a numerical derivative filtering algorithm was evaluated.

Carver, Kyle L.↗

Fast Eigen-based signal combining algorithms for large antenna arrays

A Large array of small antennas can be used to enhance signals with very low signal-to-noise ratio and can also be used to replace large apertures. In this paper, a fast combining algorithm is proposed and analyzed to maximize the combined output signal-to-noise ratio.

Eigen signal combining array↗

Detection of single atoms and buried defects in three dimensions by aberration-corrected electron microscope with 0.5-A information limit.

The ability of electron microscopes to analyze all the atoms in individual nanostructures is limited by lens aberrations. However, recent advances in aberration-correcting electron optics have led to greatly enhanced instrument performance and new techniques of electron microscopy. The development of an ultrastable electron microscope with aberration-correcting optics and a monochromated high-brightness source has significantly improved instrument resolution and contrast. In the present work, we report information transfer beyond 50 pm and show images of single gold atoms with a signal-to-noise ratio as large as 10. The instrument's new capabilities were exploited to detect a buried {Sigma}3 {l_brace}112{r_brace} grain boundary and observe the dynamic arrangements of single atoms and atom pairs with sub-angstrom resolution. These results mark an important step toward meeting the challenge of determining the three-dimensional atomic-scale structure of nanomaterials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗