Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Scanning tunneling microscopy of the atomically smooth (001) surface of vanadium pentoxide V{sub 2}O{sub 5} crystals

The (001) cleavage surface of vanadium pentoxide (V{sub 2}O{sub 5}) crystal has been studied by scanning tunneling spectroscopy (STM). It is shown that the surface is not reconstructed; the STM image allows geometric lattice parameters to be determined with high accuracy. The nanostructure formed on the (001) cleavage surface of crystal consists of atomically smooth steps with a height multiple of unit-cell parameter c = 4.37 Å. The V{sub 2}O{sub 5} crystal cleavages can be used as references in calibration of a scanning tunneling microscope under atmospheric conditions both along the (Ñ…, y) surface and normally to the sample surface (along the z axis). It is found that the terrace surface is not perfectly atomically smooth; its roughness is estimated to be ~0.5 Å. This circumstance may introduce an additional error into the microscope calibration along the z coordinate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Perspectives on deterministic control of quantum point defects by scanned probes

Control over individual point defects in solid-state systems is becoming increasingly important, not only for current semiconductor industries but also for next generation quantum information science and technologies. To realize the potential of these defects for scalable and high-performance quantum applications, precise placement of defects and defect clusters at the nanoscale is required, along with improved control over the nanoscale local environment to minimize decoherence. These requirements are met using scanned probe microscopy in silicon and III-V semiconductors, which suggests the extension to hosts for quantum point defects such as diamond, silicon carbide, and hexagonal boron nitride is feasible. Here we provide a perspective on the principal challenges toward this end, and new opportunities afforded by the integration of scanned probes with optical and magnetic resonance techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Report – Study of Shortwave Spectra in Fully 3D Environment. Synergy Between Scanning Radars and Spectral Radiation Measurements

ARM set out 20 years ago to “close” the radiation problem, that is, to improve radiation models to the point where they could routinely predict the observed spectral radiation fluxes knowing the optical properties of the surface and of gases, clouds and aerosols in the atmosphere. Only then could such radiation models form a proper springboard for global climate model (GCM) parameterizations of spectral radiation. Sustained efforts have more or less achieved that goal with regard to longwave radiation; ASR models now routinely predict ARM spectral longwave radiances to 1–2%. Similar efforts in the shortwave have achieved far less; the successes are mainly for carefully selected 1D stratiform cloud cases. Such cases amount, even with the most optimistic interpretation, to no more than 30% of all cases at SGP. The problem has not been lack of effort but lack of appropriate instruments.The new ARM stimulus-funded instruments, with their new capabilities, will dramatically improve this situation and once again make progress possible on the shortwave problem. The new shortwave spectrometers will provide a reliable, calibrated record including the near infrared – and for other climatic regimes than SGP. The new scanning radars will provide the 3D cloud view, making it possible to tackle fully 3D situations. Thus, our main theme for the project is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars and shortwave spectrometers with the arsenal of radiative transfer tools.

54 ENVIRONMENTAL SCIENCES↗

U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

36 MATERIALS SCIENCE↗

U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

36 MATERIALS SCIENCE↗

Scanning Quantum Cryogenic Atom Microscope (Final Technical Report)

The SQCRAMscope, Scanning Quantum Cryogenic Atom Microscope, is a novel scanning probe microscope we developed during this DOE fund period. It is now capable of imaging transport in cryogenically cooled solid-state samples, as we have recently demonstrated with iron-based pnictide superconductors. As such, it opens a new frontier in the quantum-based metrology of materials and is the first example of the direct marriage of ultracold AMO physics with condensed matter physics. We predict the SQCRAMscope will become an important element in the toolbox for exploring strongly correlated and topologically nontrivial materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Revisiting matrix-based inversion of scanning mobility particle sizer (SMPS) and humidified tandem differential mobility analyzer (HTDMA) data

Abstract. Tikhonov regularization is a tool for reducing noise amplification during data inversion. This work introduces RegularizationTools.jl, a general-purpose software package for applying Tikhonov regularization to data. The package implements well-established numerical algorithms and is suitable for systems of up to ∼ 1000 equations. Included is an abstraction to systematically categorize specific inversion configurations and their associated hyperparameters. A generic interface translates arbitrary linear forward models defined by a computer function into the corresponding design matrix. This obviates the need to explicitly write out and discretize the Fredholm integral equation, thus facilitating fast prototyping of new regularization schemes associated with measurement techniques. Example applications include the inversion involving data from scanning mobility particle sizers (SMPSs) and humidified tandem differential mobility analyzers (HTDMAs). Inversion of SMPS size distributions reported in this work builds upon the freely available software DifferentialMobilityAnalyzers.jl. The speed of inversion is improved by a factor of ∼ 200, now requiring between 2 and 5 ms per SMPS scan when using 120 size bins. Previously reported occasional failure to converge to a valid solution is reduced by switching from the L-curve method to generalized cross-validation as the metric to search for the optimal regularization parameter. Higher-order inversions resulting in smooth, denoised reconstructions of size distributions are now included in DifferentialMobilityAnalyzers.jl. This work also demonstrates that an SMPS-style matrix-based inversion can be applied to find the growth factor frequency distribution from raw HTDMA data while also accounting for multiply charged particles. The outcome of the aerosol-related inversion methods is showcased by inverting multi-week SMPS and HTDMA datasets from ground-based observations, including SMPS data obtained at Bodega Marine Laboratory during the CalWater 2/ACAPEX campaign and co-located SMPS and HTDMA data collected at the US Department of Energy observatory located at the Southern Great Plains site in Oklahoma, USA. Results show that the proposed approaches are suitable for unsupervised, nonparametric inversion of large-scale datasets as well as inversion in real time during data acquisition on low-cost reduced-instruction-set architectures used in single-board computers. The included software implementation of Tikhonov regularization is freely available, general, and domain-independent and thus can be applied to many other inverse problems arising in atmospheric measurement techniques and beyond.

54 ENVIRONMENTAL SCIENCES↗

Topography and transport properties of oligo(phenylene ethynylene) molecular wires studied by scanning tunneling microscopy

Conjugated phenylene(ethynylene) molecular wires are of interest as potential candidates for molecular electronic devices. Scanning tunneling microscopic study of the topography and current-voltage (I-V) characteristics of self-assembled monolayers of two types of molecular wires are presented here. The study shows that the topography and I-Vs, for small scan voltages, of the two wires are quite similar and that the electronic and structural changes introduced by the substitution of an electronegative N atom in the central phenyl ring of these wires does not significantly alter the self-assembly or the transport properties.

Polymers/chemistry↗

Modification and Development of a Control Mechanism for the Scanning Microwave Limb Sounder

The scanning microwave limb sounder (SMLS) is the latest instrument to probe the Earth's atmosphere to come out of the Microwave Limb Sounder (MLS) team. Once deployed to the upper stratosphere, it will use microwave detection to measure geo-atmospheric variables such as temperature, pressure, and chemical composition. In addition to previous missions that used vertical limb scans to observe altitudinal variations, the SMLS will rotate laterally allowing it to establish two-dimensional variable dependencies with a single run. A program was originated by a previous intern that will automatically control the movement of the two rotational axes along with a switching mirror and chopper once the instrument is in flight. However, it lacked the code essential to control system's ability to function fully and reliably. By modifying and rewriting parts of the code I sought to have a finished ready-for-flight control system that would be easy to navigate. Three of the major alterations I made including instituting a gyroscope, implementing a restart button, and instigating the automatic creation of a file log with each run to record the position and orientation of the SMLS.

Scanning Microwave Limb Sounder (SMLS)↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

Application of Radon Transform to Multi-Angle Measurements Made by the Research Scanning Polarimeter: A New Approach to Cloud Tomography. Part I: Theory and Tests on Simulated Data.

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP was a prototype for the Aerosol Polarimetry Sensor (APS) launched on-board the NASA Glory satellite. Currently the retrieval algorithms developed for the RSP are being adopted for the measurements of the space-borne polarimeters on the upcoming NASA’s Plankton, Aerosol, Cloud Ocean Ecosystem (PACE)satellite mission. The RSP’s uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid water cloud droplet sizes using the polarized rainbow structure. It also provides geometric constraints on the cumulus cloud’s 2D cross section yielding the cloud’s geometric shape estimates. In this study we further build on the latter technique to develop a new tomographic approach to retrieval of cloud internal structure from remote sensing measurements. While tomography in the strict definition is a technique based on active measurements yielding a tomogram (directional optical thickness as a function of angle and offset of the view ray), we developed a “semi-tomographic” approach in which tomogram of the cloud is estimated from passive observations instead of being measured directly. This tomogram is then converted into 2D spatial distribution of the extinction coefficient using inverse Radon transform (filtered back projection) which is the standard tomographic procedure used e.g., in medical CT scans. This algorithm is computationally inexpensive compared to techniques relying on highly-multi-dimensional least-square fitting; it does not require iterative 3D RT simulations. The resulting extinction distribution is defined up to an unknown constant factor, so we discuss the ways to calibrate it using additional independent measurements. In the next step we use the profile of the droplet size distribution parameters from the cloud’s side (derived by fitting the polarized rainbows) to convert the 2D extinction distribution into that of the droplet number concentration. We illustrate and validate the proposed technique using 3D-RT-simulatedRSP observations of a LES-generated Cu cloud. Quantitative comparisons between the retrieved and the original optical and microphysical parameters are presented.

clouds↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Irradiated Low-Enriched Uranium Fuel Measurements with a Gamma-Ray Scanning System

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Static Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. A goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This paper documents the modeling of the system and the calculation of the number of fissions per gram along the axial length of the SERTTA-C rodlet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

Exploring Physics of Ferroelectric Domain Walls in Real Time: Deep Learning Enabled Scanning Probe Microscopy

The functionality of ferroelastic domain walls in ferroelectric materials is explored in real-time via the in situ implementation of computer vision algorithms in scanning probe microscopy (SPM) experiment. The robust deep convolutional neural network (DCNN) is implemented based on a deep residual learning framework (Res) and holistically nested edge detection (Hed), and ensembled to minimize the out-of-distribution drift effects. The DCNN is implemented for real-time operations on SPM, converting the data stream into the semantically segmented image of domain walls and the corresponding uncertainty. Further the pre-defined experimental workflows perform piezoresponse spectroscopy measurement on thus discovered domain walls, and alternating high- and low-polarization dynamic (out-of-plane) ferroelastic domain walls in a PbTiO 3 (PTO) thin film and high polarization dynamic (out-of-plane) at short ferroelastic walls (compared with long ferroelastic walls) in a lead zirconate titanate (PZT) thin film is reported. This work establishes the framework for real-time DCNN analysis of data streams in scanning probe and other microscopies and highlights the role of out-of-distribution effects and strategies to ameliorate them in real time analytics.

36 MATERIALS SCIENCE↗

Extracting interface locations in multilayer polymer waveguide films using scanning angle Raman spectroscopy

There is an increasing demand for nondestructive in situ techniques that measure chemical content, total thickness, and interface locations for multilayer polymer films, and SA Raman spectroscopy in combination with appropriate data models can provide this information. A scanning angle (SA) Raman spectroscopy method was developed to measure the chemical composition of multilayer polymer waveguide films and to extract the location of buried interfaces between polymer layers with 7–80-nm axial spatial resolution. The SA Raman method measures Raman spectra as the incident angle of light upon a prism-coupled thin film is scanned. Six multilayer films consisting of poly(methyl methacrylate)/polystyrene or poly(methyl methacrylate)/polystyrene/poly(methyl methacrylate) were prepared with total thicknesses ranging from 330-1260 nm. The interface locations were varied by altering the individual layer thicknesses between 140-680 nm. The Raman amplitude ratio of the 1605 cm -1 peak for PS and 812 cm -1 peak for PMMA was used in calculations of the electric field intensity within the polymer layers to model the SA Raman data and extract the total thickness and interface locations. There is an average 8% and 7% difference in the measured thickness between the SA Raman and profilometry measurements for bilayer and trilayer films, respectively.

36 MATERIALS SCIENCE↗