Direct observation of unstained wet biological samples by scanning-electron generation X-ray microscopy

Analytical tools of nanometre-scale resolution are indispensable in the fields of biology, physics and chemistry. One suitable tool, the soft X-ray microscope, provides high spatial resolution of visible light for wet specimens. For biological specimens, X-rays of water-window wavelength between carbon (284 eV; 4.3 nm) and oxygen (540 eV; 2.3 nm) absorption edges provide high-contrast imaging of biological samples in water. Among types of X-ray microscope, the transmission X-ray microscope using a synchrotron radiation source with diffractive zone plates offers the highest spatial resolution, approaching 15-10 nm. However, even higher resolution is required to measure proteins and protein complexes in biological specimens; therefore, a new type of X-ray microscope with higher resolution that uses a simple light source is desirable. Here we report a novel scanning-electron generation X-ray microscope (SGXM) that demonstrates direct imaging of unstained wet biological specimens. We deposited wet yeasts in the space between two silicon nitride (Si{sub 3}N{sub 4}) films. A scanning electron beam of accelerating voltage 5 keV and current 1.6 nA irradiates the titanium (Ti)-coated Si{sub 3}N{sub 4} film, and the soft X-ray signal from it is detected by an X-ray photodiode (PD) placed below the sample. The SGXM can theoretically achieve better than 5 nm resolution. Our method can be utilized easily for various wet biological samples of bacteria, viruses, and protein complexes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiant Flux of Near Field in Temperature Measurements

In this work we present a calculation of the radiant flux exiting from an object which is at a constant temperature. The flux calculation is based in the propagation model of irradiance and it permit to predict the small variations in measurements of infrared radiation sources when the pyrometer is going far from the source, this variation is known as distance effect. The classical radiometry defines the quantity radiance, which is used in temperature measurements of objects through the infrared radiation they emit. Unfortunately the radiance does not permit to take into account the variations of the radiant flux measured by the pyrometer due to the wave propagation of the radiation given that the radiance definition is based in ray propagation, the geometrical model. Due to the anterior in this work we present a radiant flux calculation using wave model and considering the approximation of the near field or Fresnel approximation. We show experimental results that confirm our proposal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TinyTPC - A test stand for photosensitive dopants

LArTPCs highly doped with Xenon could be interesting platforms for probing MeV- and sub-MeV physics including neutrinoless-double beta decay. A main hurdle is the small fraction of scintillation photons that are collected, which significantly impacts LArTPCs' energy resolution. One solution is the use of photosensitive dopants, which convert light to charge. A team from Rutgers University and FNAL have built a test stand (TinyTPC) with a LArPix pixelated anode plane and an active mass of 2.1 kg to study these charge enhancements. Our plan is to measure the TinyTPC’s energy resolution with and without dopants for radioactive gamma sources, which is crucial for accurate calorimetric energy reconstruction of low-energy physics signals. The doping agent that will be used is isobutylene and the radiation sources are Co-60, Y-88, and Th-228.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing Black Hole Mergers

Binary black hole mergers are a promising source of gravitational waves for interferometric gravitational wave detectors. Recent advances in numerical relativity have revealed the predictions of General Relativity for the strong burst of radiation generated in the final moments of binary coalescence. We explore features in the merger radiation which characterize the final moments of merger and ringdown. Interpreting the waveforms in terms of an rotating implicit radiation source allows a unified phenomenological description of the system from inspiral through ringdown. Common features in the waveforms allow quantitative description of the merger signal which may provide insights for observations large-mass black hole binaries.

Baker, John↗

Understanding Radiation Environment at Earth and Beyond: Overview of Two Projects

The impact of radiation dramatically increases at high altitudes in the Earth’s atmosphere and in space. Therefore, monitoring and access to radiation environment measurements are critical for estimating the radiation exposure risks of aircraft and spacecraft crews and the impact of space weather disturbances on electronics. Addressing these needs requires reliable access to multi-source radiation environment data and enhanced visualization and search capabilities. The Radiation Data Portal provides an interactive web-based application for convenient search and visualization of inflight radiation measurements.

SMD↗

In-Situ Testing Methods for Mixed-Mode Harsh Environments

Future NASA missions are driving a need for instrumentation and space electronics that will operate at extreme temperatures, with low mass and extended deployments. This need results in devices that will experience dose damage at both low and high temperatures that will suppress annealing and induce accelerated wear out issues. Therefore, the ability to perform radiation tests on devices at temperature is critical. This paper analyses the methods and process to enable these test as developed at the JPL Dynamitron Facility. Since electronics are the radiation source for this facility, the steps to ensure parity with cobalt-60 testing are discussed. Also discussed are the implications for system level testing and mixed radiation mode testing for highly integrated and scaled devices.

Scheick, Leif Z↗

Radiation Data Portal: Enhancing Data Discoverability and Analysis for Understanding Space Radiation in Earth Environment

The impact of radiation dramatically increases at high altitudes in the Earth’s atmosphere and in space. Therefore, monitoring and access to radiation environment measurements are critical for estimating the radiation exposure risks of aircraft and spacecraft crews and the impact of space weather disturbances on electronics. Addressing these needs requires reliable access to multi-source radiation environment data and enhanced visualization and search capabilities. The Radiation Data Portal provides an interactive web-based application for convenient search and visualization of in-flight radiation measurements.

Heliophysics↗

Evidence of high-n hollow-ion emission from Si ions pumped by ultraintense x-rays from relativistic laser plasma

We report on the first observation of high- n hollow ions (ions having no electrons in the K or L shells) produced in Si targets via pumping by ultra-intense x-ray radiation produced in intense laser-plasma interactions reaching the radiation dominant kinetics regime (RDKR). The existence of these new types of hollow ions in high-energy density plasma has been found via observation of highly resolved x-ray emission spectra of silicon plasma. This has been confirmed by plasma kinetics calculations, underscoring the ability of powerful radiation sources to fully strip electrons from the innermost shells of light atoms. Hollow-ions spectral diagnostics provide a unique opportunity to characterize powerful x-ray radiation of laboratory and astrophysical plasmas. With the use of this technique we provide evidence for the existence of the RDKR via observation of asymmetry in the observed radiation of hollow ions from the front and rear sides of the target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrared, X-ray, and XUV astrophysics

An observational program covering wavelengths from the near infrared to 1 millimeter is reviewed. The program of millimeter observations largely consisted of analyzing previous observations since the summer humidity was too high for new observations. Maps of millimeter emission from W3, Sgr B2, W49 and M42 were made. Five extragalactic sources were detected and are discussed. Energy distributions of several of the discrete sources at the Galactic Center were studied. A 5-year visual/infrared program on Markarian galaxies is discussed which showed the presence of both thermal and nonthermal infrared radiation sources and established correlations between the infrared sources and the emission line regions. The Nova Cygnus 1975, caught during its rise as well as subsequent dimming, is also discussed. Several other continuing programs are described, including studies of dark clouds and CO maser sources.

Source record↗

A hot wire radiant energy source for mapping the field of view of a radiometer

The design and performance of a calibration device that allows the measurement of a radiometer's field of view are described. The heart of the device is a heated 0.0254-mm (0.001-inch) diameter filament that provides a variable, isothermal line source of radiant energy against a cold background. By moving this discrete line source across the field of view of a radiometer, the radiometer's spatial response can be completely mapped. The use of a platinum filament provides a durable radiation source whose temperature is stable and repeatable to 10 K over the range of 600 to 1200 K. By varying the energy emitted by the filament, the field of view of radiometers with different sensitivities (or multiple channel radiometers) can be totally mapped.

Edwards, S. F.↗

Fade measurements at L-band and UHF in mountainous terrain for land mobile satellite systems

Fading results related to land mobile satellite communications at L-band (1502 MHz) and UHF (870 MHz) are described. These results were derived from an experiment performed in a series of canyon passes in the Boulder, Colorado region of the US. The experimental configuration involved a helicopter as the source platform, which maintained a relatively fixed geometry with a mobile van containing the receiver and data-acquisition system. An unobstructed line of sight between the radiating sources and the receiving van was, for the most part, also maintained. In this configuration, the dominant mechanism causing signal fading (or enhancement) is a result of multipath. The resulting fade distributions demonstrated that at the 1 percent and 5 percent levels, 5.5- and 2.6-dB fades were on the average exceeded at L-band and 4.8- and 2.4-dB at UHF, respectively, for a path elevation angle of 45 deg. The canyon results as compared with previous roadside-tree-shadowing results demonstrate that the deciding factor dictating fade margin for future land mobile satellite systems is tree shadowing rather than fades caused by multipath.

Vogel, Wolfhard J.↗

Foam With Direction: Unraveling the Anisotropic Radiation Shielding Properties of 2D Boron Nitride Nanoplatelet Foams

Neutron radiation exposure is one of the main challenges faced during space missions. There is a critical need for advanced lightweight radiation shielding materials. Two-dimensional (2D) boron nitride nanoplatelets (BNNP) are excellent candidates for polymer matrix nanofillers due to their superior neutron shielding and thermal and mechanical properties. Furthermore, the 2D material anisotropic behavior unlocks the potential for composite property tailoring. This study fabricated ultra- lightweight lamellar BNNP foams (density 0.05 g cm –3 and 97.5% porous) via freeze-drying processing. The neutron shielding effectiveness or mass absorption coefficient of the BNNP foams with walls perpendicular to the direction of the radiation source was 14.47 cm 2 g –1 , while that of the foam with parallel configuration was only 8.51 cm 2 g –1 . The orientation-dependent neutron radiation shielding properties were modeled using the Beer-Lambert law for porous composite materials. The BNNP foam in this study has the potential to benefit advanced tailorable radiation shielding technologies for future aerospace missions.

Radiation shielding↗

Magnetostatic and magnetohydrodynamic modeling of planar wire arrays

For the past 2 years the planar wire array loads have proven their ability to create powerful x-ray radiation sources at the pulsed power facilities with the current level ranging from 1 to 3 MA. Several key features of the implosion and ablation dynamics of the planar wire arrays distinguish them from the wire arrays of the conventional cylindrical design. The uneven current partition through the array wires in planar geometry results in a significant difference between the ablation rates of the outermost and the innermost array wires. This difference is even higher in a double row planar array geometry. According to the three-dimensional magnetohydrodynamic simulations the effect of the delayed ablation of the inner array wires can result in effective mitigation of the Rayleigh-Taylor instability modes. The high number (200-300) of wires in a cylindrical array is preferable to ensure fine azimuthal symmetry of an array implosion. However this requirement is not a great concern for the planar wire array loads, which implode along the plane of wires. Hence, the low-wire-number planar array loads are naturally optimized for the Z-pinch experiments at short pulse (100 ns) 1 MA facilities. The application of planar wire array loads at high current accelerators is attractive for the purposes of the inertial confinement fusion because of the relative compactness of these loads and their potential for radiation pulse shaping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchrotron X-ray Diffraction Investigation of the Anomalous Behavior of Ice During Freezing of Aqueous Systems

Simple aqueous systems, i.e., phosphate-glycine buffers and pure water, were studied at subambient temperatures by X-ray difractometry using a high-intensity synchrotron radiation source at the Advanced Photon Source of Argonne National Laboratory. Complex X-ray diffraction (XRD) patterns, with two or more poorly resolved peaks in place of each of the four diagnostic peaks of hexagonal ice, 100, 002, 101, and 102, referred as 'splitting', were observed in the majority of cases. The splitting of up to 0.05 {angstrom} (d-spacing) was detected for 100, 002, and 101 peaks, whereas 102 peak was less affected. Deformation of the lattice of hexagonal ice, probably due to local stress created on the ice/ice or ice/container interface during water-to-ice transformation, is proposed as a possible mechanism for the observed splitting of XRD peaks. Using molecular modeling, it was estimated that the observed shifts in the peak positions are equivalent to applying a hydrostatic pressure of 2-3 kbars. The splitting can be used to quantify stresses during freezing, which could improve our understanding of the role of water-to-ice transformation on the destabilization of proteins and other biological systems.

43 PARTICLE ACCELERATORS↗

X-ray Spectroscopy of K- and L-shell Z-pinch and Astrophysical Plasmas

In recent years, there have been significant advances in instrumental capabilities for making X-ray spectroscopic measurements of astrophysical plasmas. There have been corresponding improvements in X-ray diagnostics for advanced multi-mega-ampere pulse power machines that produce increasingly large radiative yields from gas-puff and wire array Z pinch plasmas. Analysis used for Z pinches can be used to study ICF and also astrophysical plasmas where laboratory measurements and simulations are the only means to interpret observed data. The astrophysical data for Fe, the most cosmically abundant high Z element, can provide a wealth of information about cosmic plasmas. Fe is also the key element in stainless steel (SS) wire arrays that are investigated as an intense X-ray radiation source at the Z machine at Sandia National Laboratories. The implosion dynamics of an array of wires on the Z and/or refurbished Z accelerator produces an abundance of radiation from the K- and L-shell ionization stages. These dynamic plasmas are inherently non-LTE, with opacity and other factors influencing the X-ray output. As the plasma assembles on axis, a number of time resolved snapshots provide temperature and density profiles and map the emitting region. We will analyze the ionization dynamics and generate K- and L-shell spectra using the conditions generated in the Z and/or refurbished Z accelerator, described by a 1-D non-LTE radiation-hydrodynamics model. Diagnostics based on spectral shape of L-shell emissions are inherently more difficult than those based on K-shell emissions because of more complex multiplet structures and line overlaps. The non-LTE populations are obtained by using detailed atomic models that include all important excitation, ionization, and recombination processes. We will highlight the connection between laboratory Z-pinch plasma simulations and astrophysical plasmas.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiobiological studies using gamma and x rays.

There are approximately 500 self-shielded research irradiators used in various facilities throughout the U.S. These facilities use radioactive sources containing either 137Cs or 60Co for a variety of biological investigations. A report from the National Academy of Sciences[1] described the issues with security of particular radiation sources and the desire for their replacement. The participants in this effort prepared two peer-reviewed publications to document the results of radiobiological studies performed using photons from 320-kV x rays and 137Cs on cell cultures and mice. The effectiveness of X rays was shown to vary with cell type.

Potter, Charles Augustus↗

Focusing of white synchrotron radiation using large-acceptance cylindrical refractive lenses made of single – crystal diamond

Large-aperture cylindrical refractive lenses were manufactured by laser cutting of single-crystal diamond. Five linear single lenses with apertures of 1 mm and the depth of the structure of 1.2 mm were fabricated and tested at the ESRF ID06 beamline performing the focusing of white-beam synchrotron radiation. Uniform linear focus was stable during hours of exposure, representing such lenses as pre-focusing and collimating devices suitable for the front-end sections of today synchrotron radiation sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The cluster charge identification in the GEM detector for fusion plasma imaging by soft X-ray diagnostics

The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals, and cluster charge values corresponding to the energy spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗