Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Current advances in synchrotron radiation instrumentation for MX experiments

Following pioneering work 40 years ago, synchrotron beamlines dedicated to macromolecular crystallography (MX) have improved in almost every aspect as instrumentation has evolved. Beam sizes and crystal dimensions are now on the single micron scale while data can be collected from proteins with molecular weights over 10 MDa and from crystals with unit cell dimensions over 1000 Å. Furthermore it is possible to collect a complete data set in seconds, and obtain the resulting structure in minutes. The impact of MX synchrotron beamlines and their evolution is reflected in their scientific output, and MX is now the method of choice for a variety of aims from ligand binding to structure determination of membrane proteins, viruses and ribosomes, resulting in a much deeper understanding of the machinery of life. A main driving force of beamline evolution have been advances in almost every aspect of the instrumentation comprising a synchrotron beamline. In this review we aim to provide an overview of the current status of instrumentation at modern MX experiments. The most critical optical components are discussed, as are aspects of endstation design, sample delivery, visualisation and positioning, the sample environment, beam shaping, detectors and data acquisition and processing.

59 BASIC BIOLOGICAL SCIENCES↗

Phase I Three-Dimensional Conformal Radiation Dose Escalation Study in Newly Diagnosed Glioblastoma: Radiation Therapy Oncology Group Trial 98-03

Purpose: To evaluate in a Phase I trial the feasibility and toxicity of dose-escalated three-dimensional conformal radiotherapy (3D-CRT) concurrent with chemotherapy in patients with primary supratentorial glioblastoma (GBM). Methods and Materials: A total of 209 patients were enrolled. All received 46 Gy in 2-Gy fractions to the first planning target volume (PTV{sub 1}), defined as the gross tumor volume (GTV) plus 1.8 cm. A subsequent boost was given to PTV{sub 2}, defined as GTV plus 0.3 cm. Patients were stratified into two groups (Group 1: PTV{sub 2} <75 cm{sup 3}; Group 2: PTV{sub 2} {>=}75 cm{sup 3}). Four RT dose levels were evaluated: 66, 72, 78, and 84 Gy. Carmustine 80 mg/m{sup 2} was given during RT, then every 8 weeks for 6 cycles. Pretreatment characteristics were well balanced. Results: Acute and late Grade 3/4 RT-related toxicities were no more frequent at higher RT dose or with larger tumors. There were no dose-limiting toxicities (acute Grade {>=}3 irreversible central nervous system toxicities) observed on any dose level in either group. On the basis of the absence of dose-limiting toxicities, dose was escalated to 84 Gy in both groups. Late RT necrosis was noted at 66 Gy (1 patient), 72 Gy (2 patients), 78 Gy (2 patients), and 84 Gy (3 patients) in Group 1. In Group 2, late RT necrosis was noted at 78 Gy (1 patient) and 84 Gy (2 patients). Median time to RT necrosis was 8.8 months (range, 5.1-12.5 months). Median survival in Group 1 was 11.6-19.3 months. Median survival in Group 2 was 8.2-13.9 months. Conclusions: Our study shows the feasibility of delivering higher than standard (60 Gy) RT dose with concurrent chemotherapy for primary GBM, with an acceptable risk of late central nervous system toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In situ radiation damage studies of La{sub x}Sr{sub 1-3x/2}TiO{sub 3} perovskites

Seven perovskite samples in the La{sub x}Sr{sub 1-3x/2}TiO{sub 3} solid solution series were monitored in situ during irradiation with 1.0 MeV Kr{sup 2+} ions using the intermediate voltage electron microscope-Tandem User Facility (IVEM) at Argonne National Laboratory. All the perovskites pass through the crystalline-amorphous transformation. However, the critical temperature for amorphisation T{sub c} of the La{sub x}Sr{sub 1-3x/2}TiO{sub 3} perovskites varies nonlinearly with composition, decreasing from 394{+-}3 K for SrTiO{sub 3} to a minimum of 275{+-}1 K for La{sub 0.2}Sr{sub 0.7}TiO{sub 3}, then increasing with composition again to 865{+-}3 K for La{sub 0.67}TiO{sub 3}. In combination with the work of previous authors, the electron microscopy results and IVEM data in this study suggest that there is a vacancy-assisted recovery mechanism in the cubic perovskites with compositions in the range 0<x<0.2 that may not be directly associated with the cubic-tetragonal phase transformation and that vacancy-enhanced amorphisation occurs for both cubic and orthorhombic perovskites with compositions in the range x={approx}0.2-0.67.

36 MATERIALS SCIENCE↗

Testing Asymmetry in Plasma-Ball Growth Seeded by a Nanoscale Absorbing Defect Embedded in a SiO2 Thin-Film Matrix Subjected to UV Pulsed-Laser Radiation

Previous studies of ultraviolet, nanosecond-pulsed-laser damage in thin films revealed nanoscale absorbing defects as a major source of damage initiation. It was also demonstrated that damage (crater formation) is facilitated by plasma-ball formation around absorbing defects. In this work an attempt is made to verify the symmetry of the plasma ball by irradiating SiO2 thin film with embedded gold nanoparticles from the side of either the air/film or substrate/film interfaces. Crater-formation thresholds derived in each case support preferential plasma-ball growth in the direction of the laser-beam source. The strong impact of internal E-field distribution is identified.

Papernov, S↗

Radiation hardening of gated x-ray imagers for the National Ignition Facility (invited)

The National Ignition Facility will soon be producing x-ray flux and neutron yields higher than any produced in laser driven implosion experiments in the past. Even a non-igniting capsule will require x-ray imaging of near burning plasmas at 10{sup 17} neutrons, requiring x-ray recording systems to work in more hostile conditions than we have encountered in past laser facilities. We will present modeling, experimental data and design concepts for x-ray imaging with electronic recording systems for this environment (ARIANE). A novel instrument, active readout in a nuclear environment, is described which uses the time-of-flight difference between the gated x-ray signal and the neutron which induces a background signal to increase the yield at which gated cameras can be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The direct measurement of ablation pressure driven by 351-nm laser radiation

The instantaneous scaling of ablation pressure to laser intensity is directly inferred for ramp compression of diamond targets irradiated by 351-nm light. Continuously increasing pressure profiles from 100 to 970 GPa are produced by direct-drive laser ablation at intensities up to 7 × 1013 W/cm2. The free-surface velocity on the rear of the target is used to directly infer the instantaneous ablation-pressure profile at the front of the target. The laser intensity on target is determined by laser power measurements and fully characterized laser spots. The ablation pressure is found to depend on the laser intensity as P(GPa)=42(±3)[I(TW/cm2)]0.71(±0.01).

Fratanduono, D. E.↗

Time resolved 3D momentum imaging of ultrafast dynamics by coherent VUV-XUV radiation

We present a new experimental setup for measuring ultrafast nuclear and electron dynamics of molecules after photo-excitation and ionization. We combine a high flux femtosecond vacuum ultraviolet (VUV) and extreme ultraviolet (XUV) source with an internally cold molecular beam and a 3D momentum imaging particle spectrometer to measure electrons and ions in coincidence. We describe a variety of tools developed to perform pump-probe studies in the VUV-XUV spectrum and to modify and characterize the photon beam. First benchmark experiments are presented to demonstrate the capabilities of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control of the photoelectron dynamics for the effective conversion of short-pulse, frequency-modulated optical radiation into X-ray radiation

We report a theoretical investigation of high-order harmonic generation (HHG) in the ionisation of atoms by nonlinear frequency-modulated laser pulses of short duration. It is shown that the reduction in the instantaneous value of the laser pulse frequency can lead to a significant increase in the width of the plateau in the HHG spectrum. We have found optimal parameters of frequency modulation at which photons with energies of 1 keV are efficiently generated at a relatively low laser-pulse intensity. High HHG efficiency at optimal parameters is explained by the peculiarities of atomic ionisation dynamics and acceleration of photoelectrons by a frequency-modulated laser field. (extreme light fields and their applications)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation-induced damage and evolution of defects in Mo

The formation of defects in bcc Mo lattice as a result of 50-keV Xe bombardment is studied via atomistic simulation with an interatomic potential developed using the force-matching ab initio based approach. The defect evolution in the cascade is described. Diffusion and interaction of interstitials and vacancies are analyzed. Only small interstitial atom clusters form directly in the cascade. Larger clusters grow only via aggregation at temperatures up to 2000 K. Stable forms of clusters demonstrate one-dimensional diffusion with a very high diffusion coefficient and escape quickly to the open surface. Point vacancies have much lower diffusivity and do not aggregate. The possibility of a large prismatic vacancy loop formation near the impact surface as a result of fast recrystallization is revealed. The mobility of the vacancy dislocation loop segments is high, however, the motion of the entire loops is strongly hindered by neighbor point defects. This paper explains the existence of the large prismatic vacancy loops and the absence of the interstitial loops in the recent experiments with ion irradiation of Mo foils.

36 MATERIALS SCIENCE↗

Analysis of Radiation Effects in Silicon using Kinetic Monte Carlo Methods

The transient degradation of semiconductor device performance under irradiation has long been an issue of concern. Neutron irradiation can instigate the formation of quasi-stable defect structures, thereby introducing new energy levels into the bandgap that alter carrier lifetimes and give rise to such phenomena as gain degradation in bipolar junction transistors. Normally, the initial defect formation phase is followed by a recovery phase in which defect-defect or defect-dopant interactions modify the characteristics of the damaged structure. A kinetic Monte Carlo (KMC) code has been developed to model both thermal and carrier injection annealing of initial defect structures in semiconductor materials. The code is employed to investigate annealing in electron-irradiated, p-type silicon as well as the recovery of base current in silicon transistors bombarded with neutrons at the Los Alamos Neutron Science Center (LANSCE) “Blue Room” facility. Our results reveal that KMC calculations agree well with these experiments once adjustments are made, within the appropriate uncertainty bounds, to some of the sensitive defect parameters.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

SU-F-T-104: Determining the NTCP Parameters of Pharyngeal Constrictors and Proximal Esophagus for Radiation Induced Swallowing Problems Recorded Six Months After Radiation Therapy for Head and Neck Tumors

Purpose: To estimate the radiobiological parameters of four NTCP models that describe the dose-response relations of pharyngeal constrictors and proximal esophagus regarding the severity of patient reported swallowing problems 6 months post chemo-radiotherapy. To identify the section/structure that best correlates with the manifestation of the clinical endpoints. Finally, to compare the goodness-of-fit of those models. Methods: Forty-three patients were treated on a prospective multi-institutional phase II study for oropharyngeal squamous cell carcinoma. All the patients received 60 Gy IMRT and they reported symptoms using the novel patient reported outcome version of the CTCAE. We derived the individual patient dosimetric data of superior, medium and inferior sections of pharyngeal constrictors (SPC, MPC and IPC), superior and inferior sections of esophagus (SES and IES) as separate structures as well as combinations. The Lyman-Kutcher-Burman (LKB), Relative Seriality (RS), Logit and Relative Logit (RL) NTCP models were used to fit the patient data. The fitting of the different models was assessed through the area under the receiver operating characteristic curve (AUC) and the Odds Ratio methods. Results: The AUC values were highest for the SPC for Grade ≥ 2 (0.719 for the RS and RL models, and 0.716 for LKB and Logit). For Grade ≥ 1, the respective values were 0.699 for RS, LKB and Logit and 0.676 for RL. For MPC the AUC values varied between 0.463–0.477, for IPC between 0.396–0.458, for SES between 0.556–0.613 and for IES between 0.410–0.519. The Odds Ratio for the SPC was 15.6 (1.7–146.4) for RS, LKB and Logit for NTCP of 55%. Conclusion: All the examined NTCP models could fit the clinical data with similar accuracy. The SPC appear to correlate best with the clinical endpoints of swallowing problems. A prospective study could establish the use of NTCP values of SPC as a constraint in treatment planning.

60 APPLIED LIFE SCIENCES↗