Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

An experimental study of synthetic Hydroxybastnäsite-(La) solubility and speciation in carbonate bearing aqueous solutions at 175–250 °C

The transport and enrichment of rare earth element (REE) ore bodies are dependent on the stability of aqueous metal ligand complexes and the solubility of REE bearing minerals. REE ores are commonly associated with igneous systems having aqueous fluids with high carbonate concentrations and REE solubilities have been shown to be dependent on temperature and associate anion aqueous ligands present in solution. Furthermore, this work presents solubility experiments of hydroxybastnäsite-(La) at elevated temperatures in aqueous solutions of varying carbonate concentrations. At lower temperatures, hydroxybastnäsite-(La) solubility is controlled by neutral mono-carbonate LaCO 3 OH° but at higher temperatures and activities of carbonate species, charged di-carbonate La(CO 3 ) 2 - increases and predominates. This divergence, and the difference in solubility products of other hydroxybastnäsite-(REE) phases, provides a potential mechanism for REE fractionation in carbonate dominated aqueous solutions. To illustrate one such mechanism the solubility data of hydroxybastnäsite-(La) is compared with previously reported data of hydroxybastnäsite-(Nd) at elevated temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A proposal for a new scenario framework to support research and assessment in different climate research communities

In this paper, we propose a scenario framework that could provide a scenario thread through the different climate research communities (climate change vulnerability, impact, and adaptation (VIA) and mitigation) in order to provide assessment of mitigation and adaptation strategies and other VIA challenges. The scenario framework is defined across two main axes. One is defined by the radiative forcing levels (climate signal) of the Representative Concentration Pathways (RCPs). The second axis is defined by socio-economic development and comprises elements that affect the capacity for adaptation and mitigation but also exposure to climate impacts. The proposed set of scenarios derived from this framework are limited in number, allow for comparison across various mitigation and adaptation levels, address a range of vulnerability characteristics, provide information across climate forcing and vulnerability states and spans a full century time scale. Scenario assessment based on the proposed framework would strengthen cooperation between integrated-assessment modelers, climate modelers and the VIA research community, and most importantly, facilitate the development of more consistent and comparable research within and across communities.

54 ENVIRONMENTAL SCIENCES↗

Basophile: Accurate Fragment Charge State Prediction Improves Peptide Identification Rates

In shotgun proteomics, database search algorithms rely on fragmentation models to predict fragment ions that should be observed for a given peptide sequence. The most widely used strategy (Naive model) is oversimplified, cleaving all peptide bonds with equal probability to produce fragments of all charges below that of the precursor ion. More accurate models, based on fragmentation simulation, are too computationally intensive for on-the-fly use in database search algorithms. We have created an ordinal-regression-based model called Basophile that takes fragment size and basic residue distribution into account when determining the charge retention during CID/higher-energy collision induced dissociation (HCD) of charged peptides. This model improves the accuracy of predictions by reducing the number of unnecessary fragments that are routinely predicted for highly-charged precursors. Basophile increased the identification rates by 26% (on average) over the Naive model, when analyzing triply-charged precursors from ion trap data. Basophile achieves simplicity and speed by solving the prediction problem with an ordinal regression equation, which can be incorporated into any database search software for shotgun proteomic identification.

59 BASIC BIOLOGICAL SCIENCES↗

Modelling K shell spectra from short pulse heated buried microdot targets

K shell X-ray emission measurements have been used to diagnose plasma conditions in short-pulse heated buried microdot targets on the Orion high power laser. These experiments have been used to validate simulations of short pulse laser-solid interaction that combine hybrid PIC modelling of the laser absorption with radiation-hydrodynamics simulations including an electron transport model. Comparison of these simulations with streaked K shell spectroscopy show the importance of including radial gradients in fitting the spectra. An example is presented of the emission of sulphur from a 50 µm diameter microdot sample buried in a plastic foil. Previously agreement between simulation and experiment was obtained only by treating the absorbed energy, electron temperature and beam divergence as fitting parameters. Overall, the good agreement obtained in this work used the measured laser energy and laser pulse length and calculated the laser-solid target interaction from first principles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The use of geometric effects in diagnosing ion density in ICF-related dot spectroscopy experiments

Here, we describe a method to calculate the ion density of High Energy Density (HED) cylindrical plasmas used in dot spectroscopy experiments. This method requires only spectroscopic measurements of the Heα region obtained from two views (Face-on and Side-on). We make use of the fact that the geometry of the plasma affects the observed flux of optically thick lines. The ion density can be derived from the aspect ratio (height-to-radius) of the cylinder and the optical depth of the Heα-y line (1s2p 3 P 1 → 1s 2 1 S 0 ). The aspect ratio and the optical depth of the y line are obtained from the spectra using ratios measured from the two directions of emission of the optically thick Heα-w line (1s2p 1 P 1 → 1s 2 1 S 0 ) and the ratio of the optically thick to thin lines. The method can be applied to mid-Z elements at ion densities of 10 19 – 10 20 cm -3 and temperatures of a the order of keV, which is a relevant regime for Inertial Confinement Fusion (ICF)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of femtosecond broadband X-rays from laser wakefield acceleration as a source for pump-probe X-ray absorption studies

Here, we present X-ray absorption measurements near the K-edge of laser heated aluminum in a pump-probe configuration using X-rays generated in a laser wakefield accelerator. A 30 fs duration laser pulse from the Hercules laser system was split into two beamlines, with one used to heat a 4 $μ$m thickness Al foil and the second to drive a laser wakefield accelerator. The laser-heated plasma was probed at various pump- probe delays using the femtosecond duration X-rays generated by betatron oscillations of the electrons in the wakefield. We observe an apparent blue-shift of the K-edge occurring on a sub-picosecond timescale in the transmission spectra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data-driven offshore CO 2 saline storage assessment methodology

The world produces approximately 50 billion tonnes of greenhouse gases annually. This is measured in CO 2 -equivalents, and geologic CO 2 storage has the potential to advance decarbonization and mitigate greenhouse gas emissions. New technologies to assess offshore carbon storage are needed to address resource, regulatory, and commercial needs. Although most efforts to assess storage resources focus on onshore criteria, offshore reservoirs offer significant storage potential and distinct development challenges. Potential advantages of offshore carbon storage include being further from human population centers and less potential to interact with groundwater. The U.S. Department of Energy's method for evaluating storage capacity in non-oil-bearing saline reservoirs has been enhanced to support assessments for offshore environments in the Offshore CO 2 Saline Storage methodology (OCSS). This methodology applies data-driven capabilities to estimate saline storage capacity while accounting for features specific to offshore reservoirs. Features include changes in CO 2 density and sedimentary differences that impact estimates of permanence and capacity. The Offshore CO 2 Saline Storage Calculator mechanizes OCSS to estimate storage capacity. This paper presents the methodology and estimates for 18 geologic domains in the Gulf of Mexico. Potential storage distributions, sensitivity analyses, and the incorporation of spatial data and tools to support safe site selection are also discussed.

58 GEOSCIENCES↗

Cost of a potential hydrogen-refueling network for heavy-duty vehicles with long-haul application in Germany 2050

Long-distance road-freight transport emits a large share of Germany's greenhouse gas (GHG) emissions. A potential solution for reducing GHG emissions in this sector is to use green hydrogen in fuel cell electric vehicles (FC-HDV) and establish an accompanying hydrogen refueling station (HRS) network. In this paper, we apply an existing refueling network design model to a HDV-HRS network for Germany until 2050 based on German traffic data for heavy-duty trucks and estimate its costs. Comparing different fuel supply scenarios (pipeline vs. on-site), the on-site scenario results show a network consisting of 137 stations at a cost of 8.38 billion € per year in 2050 (0.40 € per vehicle km), while the centralized scenario with the same amount of stations shows a cheaper cost with 7.25 billion euros per year (0.35 € per vehicle km). Finally, the hydrogen cost (LCOH) varies from 5.59 €/kg (pipeline) to 6.47 €/kg (on-site) in 2050.

08 HYDROGEN↗

Machine-learning and first-principles investigation of lightweight medium-entropy alloys for hydrogen-storage applications

The transition to a low-carbon economy demands efficient and sustainable energy-storage solutions, with hydrogen emerging as a promising clean-energy carrier and with metal hydrides recognized for their hydrogen-storage capacity. Here, we leverage machine learning (ML) to predict hydrogen-to-metal (H/M) ratios and solution energy by incorporating thermodynamic parameters and local lattice distortion (LLD) as key features. Our best-performing ML model provides improvements to H/M ratios and solution energies over a broad class of medium-entripy alloys (easily extendable to multi-principal-element alloys), such as Ti–Nb-X (X = Mo, Cr, Hf, Ta, V, Zr) and Co–Ni-X (X = Al, Mg, V). Ti–Nb–Mo alloys reveal compositional effects in H-storage behavior, in particular Ti, Nb, and V enhance H-storage capacity, while Mo reduces H/M and hydrogen weight percent by 40–50 %. We attributed results in molybdenum-rich alloys to slow hydrogen kinetics, as validated by our pressure-composition-temperature (PCT) isotherm experiments on pure Ti and Ti 5 Mo 95 alloys. Density functional theory (DFT) and molecular dynamics (MD) simulations also confirm that Ti and Nb promote H diffusion, whereas Mo hinders it, highlighting the interplay between electronic structure, lattice distortions, and hydrogen uptake. Notably, our Gradient Boosting Regression model identifies LLD as a critical factor in H/M predictions. Here, to aid material selection, we present two periodic tables illustrating elemental effects on (a) H 2 wt% and (b) solution energy, derived from ML, and provide a reference for identifying alloying elements that enhance hydrogen solubility and storage.

08 HYDROGEN↗

Bayesian optimal experimental design for constitutive model calibration

Computational simulation is increasingly relied upon for high/consequence engineering decisions, which necessitates a high confidence in the calibration of and predictions from complex material models. However, the calibration and validation of material models is often a discrete, multi-stage process that is decoupled from material characterization activities, which means the data collected does not always align with the data that is needed. To address this issue, an integrated workflow for delivering an enhanced characterization and calibration procedure—Interlaced Characterization and Calibration (ICC)—is introduced and demonstrated. Further, this framework leverages Bayesian optimal experimental design (BOED), which creates a line of communication between model calibration needs and data collection capabilities in order to optimize the information content gathered from the experiments for model calibration. Eventually, the ICC framework will be used in quasi real-time to actively control experiments of complex specimens for the calibration of a high-fidelity material model. This work presents the critical first piece of algorithm development and a demonstration in determining the optimal load path of a cruciform specimen with simulated data. Calibration results, obtained via Bayesian inference, from the integrated ICC approach are compared to calibrations performed by choosing the load path a priori based on human intuition, as is traditionally done. The calibration results are communicated through parameter uncertainties which are propagated to the model output space (i.e. stress–strain). In these exemplar problems, data generated within the ICC framework resulted in calibrated model parameters with reduced measures of uncertainty compared to the traditional approaches.

42 ENGINEERING↗

Treatment Parameters and Outcome in 680 Treatments of Internal Radiation With Resin {sup 90}Y-Microspheres for Unresectable Hepatic Tumors

Purpose: Radioembolization (RE) using {sup 90}Y-microspheres is an effective and safe treatment for patients with unresectable liver malignancies. Radiation-induced liver disease (RILD) is rare after RE; however, greater understanding of radiation-related factors leading to serious liver toxicity is needed. Methods and Materials: Retrospective review of radiation parameters was performed. All data pertaining to demographics, tumor, radiation, and outcomes were analyzed for significance and dependencies to develop a predictive model for RILD. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria Adverse Events Version 3.0 scale. Results: A total of 515 patients (287 men; 228 women) from 14 US and 2 EU centers underwent 680 separate RE treatments with resin {sup 90}Y-microspheres in 2003-2006. Multifactorial analyses identified factors related to toxicity, including activity (GBq) Selective Internal Radiation Therapy delivered (p < 0.0001), prescribed (GBq) activity (p < 0.0001), percentage of empiric activity (GBq) delivered (p < 0.0001), number of prior liver treatments (p < 0.0008), and medical center (p < 0.0001). The RILD was diagnosed in 28 of 680 treatments (4%), with 21 of 28 cases (75%) from one center, which used the empiric method. Conclusions: There was an association between the empiric method, percentage of calculated activity delivered to the patient, and the most severe toxicity, RILD. A predictive model for RILD is not yet possible given the large variance in these data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness of Educational Intervention on the Congruence of Prostate and Rectal Contouring as Compared With a Gold Standard in Three-Dimensional Radiotherapy for Prostate

Purpose: To examine effects of a teaching intervention on precise delineation of the prostate and rectum during planning of three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: A pretest, posttest, randomized controlled group design was used. During pretest all participants contoured prostate and rectum on planning CT. Afterward, they participated in two types of workshops. The experimental group engaged in an interactive teaching session focused on prostate and rectum MR anatomy compared with CT anatomy. The control group focused on 3D-CRT planning without mention of prostate or rectal contouring. The experimental group practiced on fused MR-CT images, whereas the control group practiced on CT images. All participants completed the posttest. Results: Thirty-one trainees (12 male, 19 female) were randomly assigned to two groups, 17 in the experimental arm, and 14 in the control group. Seventeen felt familiar or very familiar with pelvic organ contouring, 12 somewhat, and 2 had never done it. Thirteen felt confident with organ contouring, 13 somewhat, and 5 not confident. The demographics and composition of groups were analyzed with chi{sup 2} and repeated-measures analysis of variance with the two groups (experimental or control) and two tests (pre- or posttest) as factors. Satisfaction with the course and long-term effects of the course on practice were assessed with immediate and delayed surveys. All performance variables showed a similar pattern of results. Conclusions: The training sessions improved the technical performance similarly in both groups. Participants were satisfied with the course content, and the delayed survey reflected that cognitively participants felt more confident with prostate and rectum contouring and would investigate opportunities to learn more about organ contouring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity Analysis of Postoperative Image-Guided Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: To report on the acute and late gastrointestinal (GI) and genitourinary (GU) toxicity associated with a unique technique of image-guided radiotherapy (IGRT) in patients undergoing postprostatectomy irradiation. Methods and Materials: Fifty patients were treated with intensity-modulated radiation therapy (IMRT) after radical prostatectomy. Daily image guidance was performed to localize the prostate bed using kilovoltage imaging or cone-beam computed tomography. The median prescription dose was 68 Gy (range, 62-68 Gy). Toxicity was graded every 3 to 6 months according to the Common Terminology Criteria for Adverse Events version 3.0. Results: The median follow-up was 24 months (range, 13-38 months). Grade 2 acute GI and GU events occurred in 4 patients (8%) and 7 patients (14%), respectively. No Grade 3 or higher acute GI or GU toxicities were observed. Late Grade 2 GI and GU events occurred in 1 patient (2%) and 8 patients (16%), respectively. Only a single (2%) Grade 3 or higher late toxicity was observed. Conclusions: Image-guided IMRT in the postprostatectomy setting is associated with a low frequency of acute and late GI/GU toxicity. These results compare more favorably to radiotherapy techniques that do not use in-room image-guidance, suggesting that daily prostate bed localization may reduce the incidence of adverse events in patients undergoing postprostatectomy irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Complication Probability Modeling of Acute Hematologic Toxicity in Cervical Cancer Patients Treated With Chemoradiotherapy

Purpose: To test the hypothesis that increased pelvic bone marrow (BM) irradiation is associated with increased hematologic toxicity (HT) in cervical cancer patients undergoing chemoradiotherapy and to develop a normal tissue complication probability (NTCP) model for HT. Methods and Materials: We tested associations between hematologic nadirs during chemoradiotherapy and the volume of BM receiving {>=}10 and 20 Gy (V{sub 10} and V{sub 20}) using a previously developed linear regression model. The validation cohort consisted of 44 cervical cancer patients treated with concurrent cisplatin and pelvic radiotherapy. Subsequently, these data were pooled with data from 37 identically treated patients from a previous study, forming a cohort of 81 patients for normal tissue complication probability analysis. Generalized linear modeling was used to test associations between hematologic nadirs and dosimetric parameters, adjusting for body mass index. Receiver operating characteristic curves were used to derive optimal dosimetric planning constraints. Results: In the validation cohort, significant negative correlations were observed between white blood cell count nadir and V{sub 10} (regression coefficient ({beta}) = -0.060, p = 0.009) and V{sub 20} ({beta} = -0.044, p = 0.010). In the combined cohort, the (adjusted) {beta} estimates for log (white blood cell) vs. V{sub 10} and V{sub 20} were as follows: -0.022 (p = 0.025) and -0.021 (p = 0.002), respectively. Patients with V{sub 10} {>=} 95% were more likely to experience Grade {>=}3 leukopenia (68.8% vs. 24.6%, p < 0.001) than were patients with V{sub 20} > 76% (57.7% vs. 21.8%, p = 0.001). Conclusions: These findings support the hypothesis that HT increases with increasing pelvic BM volume irradiated. Efforts to maintain V{sub 10} < 95% and V{sub 20} < 76% may reduce HT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Bone Marrow Radiation Dose on Acute Hematologic Toxicity in Cervical Cancer: Principal Component Analysis on High Dimensional Data

Purpose: To study the effects of increasing pelvic bone marrow (BM) radiation dose on acute hematologic toxicity in patients undergoing chemoradiotherapy, using a novel modeling approach to preserve the local spatial dose information. Methods and Materials: The study included 37 cervical cancer patients treated with concurrent weekly cisplatin and pelvic radiation therapy. The white blood cell count nadir during treatment was used as the indicator for acute hematologic toxicity. Pelvic BM radiation dose distributions were standardized across patients by registering the pelvic BM volumes to a common template, followed by dose remapping using deformable image registration, resulting in a dose array. Principal component (PC) analysis was applied to the dose array, and the significant eigenvectors were identified by linear regression on the PCs. The coefficients for PC regression and significant eigenvectors were represented in three dimensions to identify critical BM subregions where dose accumulation is associated with hematologic toxicity. Results: We identified five PCs associated with acute hematologic toxicity. PC analysis regression modeling explained a high proportion of the variation in acute hematologicity (adjusted R{sup 2}, 0.49). Three-dimensional rendering of a linear combination of the significant eigenvectors revealed patterns consistent with anatomical distributions of hematopoietically active BM. Conclusions: We have developed a novel approach that preserves spatial dose information to model effects of radiation dose on toxicity, which may be useful in optimizing radiation techniques to avoid critical subregions of normal tissues. Further validation of this approach in a large cohort is ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irradiation-Dependent Effects on Tumor Perfusion and Endogenous and Exogenous Hypoxia Markers in an A549 Xenograft Model

Purpose: Hypoxia is a major determinant of tumor radiosensitivity, and microenvironmental changes in response to ionizing radiation (IR) are often heterogenous. We analyzed IR-dependent changes in hypoxia and perfusion in A549 human lung adenocarcinoma xenografts. Materials and Methods: Immunohistological analysis of two exogenously added chemical hypoxic markers, pimonidazole and CCI-103F, and of the endogenous marker Glut-1 was performed time dependently after IR. Tumor vessels and apoptosis were analyzed using CD31 and caspase-3 antibodies. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and fluorescent beads (Hoechst 33342) were used to monitor vascular perfusion. Results: CCI-103F signals measuring the fraction of hypoxic areas after IR were significantly decreased by approximately 50% when compared with pimonidazole signals, representing the fraction of hypoxic areas from the same tumors before IR. Interestingly, Glut-1 signals were significantly decreased at early time point (6.5 h) after IR returning to the initial levels at 30.5 h. Vascular density showed no difference between irradiated and control groups, whereas apoptosis was significantly induced at 10.5 h post-IR. DCE-MRI indicated increased perfusion 1 h post-IR. Conclusions: The discrepancy between the hypoxic fractions of CCI-103F and Glut-1 forces us to consider the possibility that both markers reflect different metabolic alterations of tumor microenvironment. The reliability of endogenous markers such as Glut-1 to measure reoxygenation in irradiated tumors needs further consideration. Monitoring tumor microvascular response to IR by DCE-MRI and measuring tumor volume alterations should be encouraged.

62 RADIOLOGY AND NUCLEAR MEDICINE↗