Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Portal Monitoring Considerations for Treaty Verification Applications

Portal monitoring is one method in a suite of options for treaty verification and can assist in verification of treaty accountable items (TAIs). Portal monitor technology spans a wide range of sensors, including radiation detectors, break-beams, or weight sensors. For radiation-detecting portal monitors, they are able to confirm absence / presence of a radiological signature and to track TAI direction of motion. Portal monitoring uses measurements from strategically placed sensors (e.g., radiation detectors) to record the entry or egress of TAIs. The implementation of portal monitoring relies on three key elements: perimeter definition, portal locations, and sensor technology, and can be implemented in either time-bound or continuous operations depending on what is permitted by the Treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

High-Resolution Aerial Radiation Mapping for Nuclear Decontamination and Decommissioning - 17371

Unmanned aerial vehicles (UAVs) are now widely employed as part of numerous applications including defence, search and rescue as well as within scientific fields such as high-altitude atmospheric sampling and remote sensing, to name but a few. However, their application to the high-resolution detection of radiation anomalies (specifically as part of the routine monitoring on nuclear sites) has been less well explored. In this work, we present the results of the radiation monitoring via a lightweight aerial platform on an active nuclear site (Sellafield Ltd.); having already deployed the device in the Fukushima-contaminated region. The system employed was able to detect regions of elevated radiation at the sub-meter scale as well as attributing the species responsible. Such a system presents an extremely powerful tool where it is not desirable, nor practical, to send human operators. Results presented show that the platform is easily capable of operating within the challenging and confined settings of a site such as Sellafield (or other similar sites worldwide). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-J-202: Secondary Radiation Measurements for Charged Particle Therapy Monitoring: Fragmentation of Therapeutic He, C and O Ion Beams Impinging On a PMMA Target

Purpose: In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on-line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here. Methods: We present the measurements of the secondary radiation generated by He, C and O beams impinging on a beam stopping PMMA target. The data has been collected at the Heidelberg Ionbeam Therapy center (HIT), where several millions of collisions were recorded at different energies, relevant for therapeutical applications. Results: The experimental setup, as well as the analysis strategies will be reviewed. The detected particle fluxes as a function of the primary beam energy and the emission angle with respect to the beam direction will be presented and compared to the results of other available measurements. In addition, the energy spectra and emission shapes of charged secondary particles will be shown and discussed in the context of the primary beam range monitoring technique that is being developed by the ARPG collaboration, within the INSIDE project funded by the Italian research ministry. The implications for dose monitoring applications will be discussed, in the context of the current (or planned) state-of- the-art detector solutions. Conclusion: The characterization of the radiation produced by 12C, 4He and 16O beams fully supports the feasibility of on-line range monitoring in the clinical practice of CPT by means of secondary particles detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for anomalous optical transition radiation linear polarization effects in beam-profile monitors

Investigations of the effects of optical transition radiation (OTR) polarization components on beam profiles are presented. The transverse profiles are examined using the OTR perpendicular and parallel polarization components with respect to the dimension of interest. We observed ~15% projected profile size reductions with the perpendicularly polarized components on a 65-μm beam image size case at 14 MeV, a 150-μm beam image size at 4.5 GeV, and a 1200-μm beam image size at 7 GeV. These effects are all several times larger than expected from the standard OTR point-spread function calculations. We propose the time-averaged induced current distribution which generates the OTR represents the actual beam size more faithfully with the perpendicular polarization component and recommend its routine use and subsequent deconvolution.

Lumpkin, A. H.↗

Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

Subcommittee 45B Radiation Protection Instrumentation of the International Electrotechnical Commission (IEC) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three IEC standards are published. The international participation and the main characteristics of the following three standards are discussed and presented: IEC 62327 Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation , IEC 62401 Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material and IEC 62244 Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Prospective Cohort Study of Gated Stereotactic Liver Radiation Therapy Using Continuous Internal Electromagnetic Motion Monitoring

Intrafraction motion can compromise the treatment accuracy in liver stereotactic body radiation therapy (SBRT). Respiratory gating can improve treatment delivery; however, gating based on external motion surrogates is inaccurate. The present study reports the use of Calypso-based internal electromagnetic motion monitoring for gated liver SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron Monitoring at the Area of IRC “Pamir-Chakaltaya” for Radiation Safety Control

The results of neutron monitoring at the high-altitude area of the International Research Center “Pamir-Chakaltay” at an altitude of 4370 meters above sea level are presented. Measurements with the help of radiometers PDA-Pack Eye, МКS-RМ1401К and RSU-01R revealed an excess of 5–7 times the neutron flux density at the 2-tier X-ray emulsion chamber in the hangar and in the storage areas of lead and rubber plates. At the same time, instrument readings experienced significant (up to 30%) fluctuations in time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimeter Area Monitoring Program (DAMP) Technical Basis Document

This document provides a technical basis for establishing a Dosimetry-based Area Monitoring Program (DAMP) at Lawrence Livermore National Laboratory (LLNL). A DAMP is part of a comprehensive routine monitoring program and provides information about radiation levels inside and outside of Radiologically-Controlled Areas (RCAs). The routine, hand-held radiation survey program driven by the Health Physics Discipline Action Plan (HP-DAP) helps to ensure radiological conditions within RCAs are well-characterized and routinely monitored; however, such surveys are a snapshot in time, whereas area monitoring dosimeters (AMDs) continuously monitor radiation doses in the areas where they are installed. Together, data from the hand-held radiation surveys and the DAMP provides a comprehensive picture of radiation environment at LLNL. A DAMP helps to verify the effectiveness of established engineered and administrative controls while documenting that radiation doses in RCAs are below that which requires individual monitoring. This document establishes the basis for determining which model of dosimeter to use, the exchange frequency, the occupancy factor, monitoring locations, and a method for evaluating AMD results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advances in remote monitoring technology for worker safety and personnel radiation exposure reduction - 15130

This paper will present an overview of advancements made in remote monitoring technology to increase worker safety and decrease personnel radiation exposure at hazardous work sites. The presentation will discuss the use of remote technology for risk reduction to working parties. Topics covered will be the use of technology as a human performance tool in pre and post job briefings, scheduling tool for work management and communication tool between working parties and radiation protection personnel that allow for micro-managing radiation exposure. The presentation will use actual technology field experience to illustrate best practices within the commercial nuclear industry and there applicability to the waste management sector. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote sounding of surface radiative fluxes in cirrus cloudy conditions

It has been long recognized that radiation and radiation perturbations play a critical role in the climate system. Surface radiative fluxes are useful parameters for monitoring global change, for understanding of the effects of clouds on the radiation field, and for improving parameterization of surface sensible and latent heat fluxes. Monitoring of the radiation budget at the top of the atmosphere has been one of the prime satellite programs for the last 30 years. However, monitoring radiative fluxes at the surface over the globe from space cannot be performed in a direct way at the present time. In particular, since clouds are the prime regulators of the radiative fluxes, uncertainties in the retrieved cloud parameters, which are inputs to radiative transfer models, can introduce significant errors in the computed radiative fluxes. Thus, remote sounding of surface radiative fluxes in cloudy conditions requires the development of both satellite cloud retrieval scheme and radiation models. In this paper, we present results of computed surface radiative fluxes in cirrus cloudy conditions using a cirrus cloud retrieval scheme and a detailed radiative transfer program. Comparisons have been made between the computed surface radiative fluxes and the ground-based radiometer measurements obtained during FIRE-II-IFO, which was carried out near Coffeyville, Kansas, during November and December, 1991.

Ou, S. C.↗

The Multi Optical Transition Radiation System

The determination and monitoring of the transverse phase space in ATF2 is crucial in order to meet their performances specifications. Since the beam sizes at the Interaction Point (IP) depend strongly on the aberrations in the Final Focus System (FFS), accurate measurement upstream of the FFS is required to tune the beam sizes at the IP. The beam sizes as well as the emittance are measured in several locations in the beam diagnostic section of the Extraction Line (EXT line) of ATF2. The vertical beam sizes in the diagnostic section are of the order of 10 {mu}m this means that the devices have to image spot sizes as small as 5 {mu}m, with 10% accuracy a 2 {mu}m resolution device is necessary. The ATF2 EXT line is a beam line with low power and low repetition rate that make usable devices using solid targets. In contrast to a ring machine, where an individual bunch can be measured many times as it passes around the ring, the beam size and the emittance measurement in the LC or in the beam lines have to be performed in a single pass. This requires that the wire scan device types (laser or solid) sample across successive bunches within a train, often with an over-estimation of the beam size due to beam position and intensity jitter, and can take up to half a minute to complete the measurement. Although some of these effects could be corrected, as the jitter effect could be subtracted by using the nearby BPMs signals, this can be avoided by using Optical Transition Radiation (OTR) Monitors. These monitors are based on the transition radiation effect, a light cone emitted when the charged particle crosses a metallic interface. This light is emitted in a specular fashion so it can be focused on to a CCD and produces an image of the beam. OTRs are able to take many fast measurements and therefore to measure the emittance with high statistics, giving a low error and a good understanding of the emittance jitter. In this article, simulations of the expected beam sizes and emittance, along with a technical description of the system, its hardware and software implementation are described. Additionally first measurement of the beam size and emittance of the Multi Optical Transition Radiation System located in the Extraction Line of ATF2 are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-G-TeP3-10: Radiation Induces Prompt Live-Cell Metabolic Fluxes

Purpose: To compare metabolic dynamics and HIF-1α expression following radiation between a cancerous cell line (UM-SCC-22B) and a normal, immortalized cell line, NOK (Normal Oral Keratinocyte). HIF-1 is a key factor in metabolism and radiosensitivity. A better understanding of how radiation affects the interplay of metabolism and HIF-1 might give a better understanding of the mechanisms responsible for radiosensitivity. Methods: Changes in cellular metabolism in response to radiation are tracked by fluorescence lifetime of NADH. Expression of HIF-1α was measured by immunofluorescence for both cell lines with and without irradiation. Radiation response is also monitored with additional treatment of a HIF-1α inhibitor (chrysin) as well as a radical scavenger (glutathione). Changes in oxygen consumption and respiratory capacity are also monitored using the Seahorse XF analyzer. Results: An increase in HIF-1α was found to be in response to radiation for the cancer cell line, but not the normal cell line. Radiation was found to shift metabolism toward glycolytic pathways in cancer cells as measured by oxygen consumption and respiratory capacity. Radiation response was found to be muted by addition of glutathione to cell media. HIF-1α inhibition similarly muted radiation response in cancer. Conclusion: The HIF-1 protein complex is a key regulator cellular metabolism through the regulation of glycolysis and glucose transport enzymes. Moreover, HIF-1 has shown radio-protective effects in tumor vascular endothelia, and has been implicated in metastatic aggression. Monitoring interplay between metabolism and the HIF-1 protein complex can give a more fundamental understanding of radiotherapy response.

60 APPLIED LIFE SCIENCES↗

Study of changes in properties of solar sail materials from radiation exposure

Techniques for monitoring changes in preparation of solar sail materials resulting from space radiation simulation, stressing (e.g., thermal, mechanical) and exposure to terrestrial environments are developed. The properties of interest are: metallic coating deterioration, polymeric film deterioration, interfacial debonding and possible metallic coating diffusion into the polymeric film. Four accelerated tests were devised to simulate the possible degradation processes mentioned above. These four tests are: a thermal shock test to simulate the wide variation of temperature expected in space (260 C to -100 C), a cyclic temperature test to stimulate the 6 minute temperature cycle anticipated in space, a mechanical vibration test to simulate mechanical bonding, folding and handling, and a humidity test to simulate terrestrial environment effects. The techniques for monitoring property changes are: visual and microscopic examination, ellipsometry, surface potential difference (SPD), photoelectron emission (PEE), and water contact angles.

Smith, T.↗

Online Image-based Monitoring of Soft-tissue Displacements for Radiation Therapy of the Prostate

Purpose: Emerging prolonged, hypofractionated radiotherapy regimens rely on high-dose conformality to minimize toxicity and thus can benefit from image guidance systems that continuously monitor target position during beam delivery. To address this need we previously developed, as a potential add-on device for existing linear accelerators, a novel telerobotic ultrasound system capable of real-time, soft-tissue imaging. Expanding on this capability, the aim of this work was to develop and characterize an image-based technique for real-time detection of prostate displacements. Methods and Materials: Image processing techniques were implemented on spatially localized ultrasound images to generate two parameters representing prostate displacements in real time. In a phantom and five volunteers, soft-tissue targets were continuously imaged with a customized robotic manipulator while recording the two tissue displacement parameters (TDPs). Variations of the TDPs in the absence of tissue displacements were evaluated, as was the sensitivity of the TDPs to prostate translations and rotations. Robustness of the approach to probe force was also investigated. Results: With 95% confidence, the proposed method detected in vivo prostate displacements before they exceeded 2.3, 2.5, and 2.8 mm in anteroposterior, superoinferior, and mediolateral directions. Prostate pitch was detected before exceeding 4.7 Degree-Sign at 95% confidence. Total system time lag averaged 173 ms, mostly limited by ultrasound acquisition rate. False positives (FPs) (FP) in the absence of displacements did not exceed 1.5 FP events per 10 min of continuous in vivo imaging time. Conclusions: The feasibility of using telerobotic ultrasound for real-time, soft-tissue-based monitoring of target displacements was confirmed in vivo. Such monitoring has the potential to detect small clinically relevant intrafractional variations of the prostate position during beam delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of Real-Time Internal Electromagnetic Position Monitoring Coupled With Dynamic Multileaf Collimator Tracking: An Intensity-Modulated Radiation Therapy Feasibility Study

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. Methods and Materials: A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Results: Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: {+-}3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Conclusions: Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-cost, multi-mode detector solutions

Low-cost radiation detectors capable of providing efficient gamma-ray and neutron detection are essential in passive nuclear monitoring systems such as radiation portal monitors (RPMs) and detection of Special Nuclear Materials (SNM) through Active Interrogation (AI). Here, three low-cost detector solutions are discussed—(1) Large-area polystyrene-based plastic scintillators for AI (2) Pulse Shape Discrimination (PSD) capable plastic scintillators doped with heavy-metals for imparting gamma-ray spectroscopy (3) Composite detector technology based on inorganic scintillator submerged into the plastic scintillator, for detection of thermal and fast neutrons in addition to gamma-ray spectroscopy. Composite detectors using inorganic component such as Cs 2 LiYCl 6 (CLYC), Cs 2 LiLaBr x Cl 6-x (CLLBC), or CsI:Tl have been developed up to 4” sizes. Neutron and gamma efficiencies are compared for samples with different inorganic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the infrared test method for the olympus thermal balance tests

The performance of the infrared (IR) rig used for the thermal balance testing of the Olympus S/C thermal model is discussed. Included in this evaluation are the rig effects themselves, the IRFLUX computer code used to predict the radiation inputs, the Monitored Background Radiometers (MBR's) developed to measure the absorbed radiation flux intensity, the Uniform Temperature Reference (UTR) based temperature measurement system and the data acquisition system. A preliminary set of verification tests were performed on a 1 m x 1 m zone to assess the performance of the IR lamps, calrods, MBR's and aluminized baffles. The results were used, in part, to obtain some empirical data required for the IRFLUX code. This data included lamp and calrod characteristics, the absorptance function for various surface types, and the baffle reflectivities.

Donato, M.↗