Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Cryomodule Test Stand Reduced-Magnetic Support Design At Fermilab

In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be tested at Fermilab's Cryomodule Test Facility (CMTF) within the Cryomodule Test Stand (CMTS-1) cave. The problem of magnetic pollution became one of major issues during design stage of the LCLS-II cryomodule as the average quality factor of the accelerating cavities is specified to be $2.7 \times 10^{10}$. One of the possible ways to mitigate the effect of stray magnetic fields and to keep it below the goal of 5 mGauss involves the application of low permeable materials. Initial permeability and magnetic measurement studies regarding the use of 316L stainless steel material indicated that cold work (machining) and heat affected zones from welding would be acceptable.

43 PARTICLE ACCELERATORS↗

Observation of Stable Low Surface Resistance in Large-Grain Niobium SRF Cavities

Low surface resistance, or high unloaded quality factor (Q0), superconducting radio frequency (SRF) cavities are being pursued actively nowadays as their application in large-scale CW SRF accelerators can save capital and operational cost in cryogenics. There are different options in realization of such cavities. One of them is the large-grain (LG) niobium cavity. In this contribution, we present new experimental results in evaluation of LG niobium cavities cooled down in the presence of an external magnetic field. High Q0 values are achieved even with an ambient magnetic field of up to 100 mG. More over, it is observed that these high Q0 values are super-robust against repeated quench, literally not affected at all after the cavity being deliberately quenched for hundreds of times in the presence of an ambient magnetic field of up to 200 mG.

Geng, Rongli↗

MAGNETRON SPUTTERING OF Nb3Sn FOR SRF CAVITIES

Nb3Sn is a potential candidate for surface material of SRF cavities since it can enable the cavity to operate at higher temperatures with high quality factor and at an increased accelerating gradient. Nb-Sn films were deposited using magnetron sputtering of individual Nb and Sn targets onto Nb and sapphire substrates. The as-deposited films were annealed at 1200 °C for 3 hours. The films were characterized for their structure by X-ray Diffraction (XRD), morphology by Field Emission Scanning Electron Microscopy (FESEM), and composition by Energy Dispersive X-ray Spectroscopy (EDS) and Time of Flight Secondary Ion Mass Spectrometry (ToF-SIMS). The surface resistivity was measured down to cryogenic temperature to determine the superconducting transition temperature and its width. The composition of the multilayered films was controlled by varying the thickness of the Nb and Sn layers. The films showed crystalline Nb3Sn phases with Tc up to 17.6 K.

Eremeev, G.↗

Passive Microphonics Mitigation during LCLS-II Cryomodule Testing at Fermilab

The LCLS-II project calls for cryomodule production and testing at both Fermilab and JLab. Due to low beam loading and high cavity quality factor, the designed peak detuning specification is 10 Hz. Initial testing showed peak detuning up to 150 Hz with a complex and varying time-structure, showing both fast (1-2 second) and slow (1-2 hour) drifts in amplitude and spectrum. Extensive warm and cold testing showed Thermoacoustic Oscillations in the cryogenic valves were the primary source of the microphonics. This was mitigated by valve wipers and valve re-plumbing, resulting in a greatly improved cavity detuning environment. Additional modifications were made to the cavity mechanical supports and Fermilab test stand to improve detuning performance. These modifications and testing results will be presented.

43 PARTICLE ACCELERATORS↗

Development of Nb3Sn Coatings for Superconducting RF Cavities at Fermilab

Nb3Sn films are a promising alternative material for su-perconducting RF cavities, with proven high quality factors at medium fields and predictions for increased superheating field as well. In this contribution, we de-scribe the latest results from the Fermilab Nb3Sn SRF program. Early experiments have been focused on single cell 1.3 GHz cavities. We briefly review efforts to bring the parameters used in the coating process into a range where they produce uniform surfaces without regions showing signs of excess tin or thin/uncoated areas. We then present the latest cavity results, after modifications to the coating recipe based on feedback from film appear-ance and RF performance. These results show high Q0 at medium fields and a maximum field of ~18 MV/m.

43 PARTICLE ACCELERATORS↗

Development of Nb3Sn multicell cavity coatings

Nb3Sn films have the potential to replace niobium in SRF cavities. Besides single-cell cavity efforts to improve Nb3Sn films, we are working to replicate single-cell results onto the practical 5-cell CEBAF cavities. High quality factors (10E11 @ 2.0K and 10E10 @ 4.3 K) have been measured, but the cavities are typically limited by strong low-field Q-slopes and quenches. Two of the cavities were selected to be assembled into a "mock-up" cavity string unit, the standard step before installation into a cryomodule. Comparison of test results between VTA and pair test offered the first glimpse into post-processing effects on the cavity performance.

Eremeev, G.↗

Nb3Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for Energy recovery linac (ERL) applications. Nb3Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities fabricated at JLab and were proposed to be coated with Nb3Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavities needs to be improved to coat these cavities. This devel-opment advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb3Sn coated twin axis cavities.

Tiskumara, J.↗

Recent Progress Toward a Conduction-Cooled Superconducting Radiofrequency Electron Gun

High-repetition-rate electron sources have widespread applications. This contribution discusses the progress toward a proof-of-principle demonstration for a conduction-cooled electron source. The source consists of a simple modification of an elliptical cavity that enhances the field electric field at the photocathode surface. The source was cooled to cryogenic temperatures and preliminary measurements for the quality factor and accelerating field were performed. Additionally, we present future plans to improve the source along with simulated beam-dynamics performances.

43 PARTICLE ACCELERATORS↗

Modeling a Nb3Sn Cryounit in GPT at UITF

Nb₃Sn is a prospective material for future superconducting RF (SRF) accelerator cavities. The material can achieve higher quality factors, higher temperature operation and potentially higher accelerating gradients (E_{acc} 96 MV/m) compared to conventional niobium. In this work, we performed modeling of the Upgraded Injector Test Facility (UITF) at Jefferson Lab utilizing newly constructed Nb₃Sn cavities. We studied the effects of the buncher cavity and varied the gun voltages from 200-500 keV. We have calibrated and optimized the SRF cavity gradients and phases for the Nb₃Sn five-cell cavities energy gains with the framework of General Particle Tracer (GPT). Our calculations show the beam goes cleanly through the unit. There is full energy gain out of the second SRF cavity but not from the first SRF cavity due to non-relativistic phase shifts.

Pokharel, S.↗

Analysis of Low RRR SRF Cavities

Recent findings in the superconducting radio-frequency (SRF) community have shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. Success has been found in nitrogen-doping, diffusion of the native oxide into the niobium surface, and thin films of alternate superconductors atop a niobium bulk cavity. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of recent impurity-based improvements can be better understood and improved upon. Additionally, we perform a low temperature bake on the low RRR cavity to evaluate how the intentional addition of oxygen to the RF layer affects performance. We have found that low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. The results of this study have the potential to unlock a new understanding on SRF materials.

43 PARTICLE ACCELERATORS↗

Evaluating the Effects of Nitrogen Doping and Oxygen Doping on SRF Cavity Performance

Superconducting radiofrequency (SRF) cavities are resonators with extremely low surface resistance that enable accelerating cavities to have extremely high quality factors (Q₀). High Q₀ decreases the capital required to keep the accelerators cold by reducing power loss. The performance of SRF cavities is largely governed by the surface composition of the first §I{100}{nm} of the cavity surface. Impurities such as oxygen and nitrogen have been observed to yield high Q₀, but their precise roles are still being studied. Here, we compare the performance of cavities doped with nitrogen and oxygen in terms of surface composition and heating behavior with field. A simulation of the diffusion of oxygen into the bulk of the cavity was built using COMSOL Multiphysics software. Simulated results were compared to the actual surface composition of the cavities as determined from secondary ion mass spectrometry analysis. Understanding how these impurities affects performance allows us to have further insight into the underlying mechanisms that enable these surface treatments to yield high Q₀.

43 PARTICLE ACCELERATORS↗

The collaborative effects of intrinsic and extrinsic impurities in low RRR SRF cavities

The superconducting radio-frequency (SRF) community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing and material analysis reveals a microscopic picture of why low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. We performed surface treatments, low temperature baking and nitrogen-doping, on low RRR cavities to evaluate how the intentional addition of oxygen and nitrogen to the RF layer further improves performance through changes in the mean free path and impurity profile. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of SRF surface treatments.

43 PARTICLE ACCELERATORS↗

Origins of quench in buffered chemical polished and low temperature baked SRF cavities

Electropolishing (EP) and buffered chemical polishing (BCP) are conventional surface preparation techniques for superconducting radiofrequency (SRF) cavities that remove damaged material from the cavity surface. One main issue with EP and BCP treated SRF cavities is high field Q-slope (HFQS), a drop in quality factor at high gradients that limits quench field. High gradient performance in EP cavities can be improved by applying a low temperature bake (LTB), but LTB does not consistently remove HFQS in BCP cavities. There is no consensus as to the why LTB is not effective on BCP prepared cavities, and the cause of HFQS in BCP cavities is not well understood. We examine the origins of quench in EP, BCP, EP+LTB, and BCP+LTB treated SRF cavities. We also show the effect of these treatments on the onset of HFQS, heating within the cavity up to quench, concentration of free hydrogen, and surface roughness.

43 PARTICLE ACCELERATORS↗

A Preliminary Feasibility Study on Multi-Cavity Cryomodule Integration for the Electron Ion Collider Energy Recover Linac Cooler

The Electron-Ion Collider (EIC) is a state-of-the-art accelerator designed for collisions between highly polarized electrons and ions. To achieve optimal luminosity, the ion beam is cooled using an electron beam sourced from an energy recovery linac (ERL). In the current ERL baseline design, one BNL type RF cavity is used per cryomodule, leading to spatial and cost challenges. This study examines the feasibility of using more compact PERLE (Powerful Energy Recovery Linac for Experiments) type cavities, which can house multiple cavities within a single cryomodule, by evaluating their Beam Breakup (BBU) instability performance. Higher Order Modes (HOM) parameters were obtained through frequency scaling, assuming constant quality factor Q_L, R/Q, and linearly scaling HOM frequencies. To predict the BBU threshold current and ensure accuracy, two different BBU tracking simulations are used for cross-verification. Although the reduced footprint of PERLE-type cavities is advantageous, maintaining sufficient damping of HOMs remains crucial. Finally, we compare the HOM damping efficiency of both cavity types and suggest a pathway forward.

Deitrick, K.↗

Microscopic understanding of the effects of impurities in low RRR SRF cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

43 PARTICLE ACCELERATORS↗

Investigation of Low-Level Nitrogen in Niobium by Secondary Ion Mass Spectrometry

Understanding the improvement of the SRF cavity quality factor by low-level nitrogen addition (?N-doping?) is attracting much attention from researchers. Precise, repeatable measurement of the nitrogen profile in the parts-per-thousand to parts-per-million range is vital. Secondary Ion Mass Spectrometry (SIMS) is the approach of choice because of excellent sensitivity and depth resolution. Accurate quantitation must consider sample properties, such as surface topography and crystal structure, calibration of the instrument with reference materials, and data analysis. We report the results of a SIMS study in which polycrystal and single crystal coupons were N-doped, each accompanied by new SRF-grade niobium sheet equivalent to a single cell cavity.

Tuggle, Jay↗

Cavity Processing and Preparation of 650 MHz Elliptical Cell Cavities for PIP-II

The PIP-II project at Fermilab requires fifteen 650 MHz SRF cryomodules as part of the 800 MeV LINAC that will provide a high intensity proton beam to the Fermilab neutrino program. A total of fifty-seven high-performance SRF cavities will populate the cryomodules and will operate in both pulsed and continuous wave modes. These cavities will be processed and prepared for performance testing utilizing adapted cavity processing infrastructure already in place at Fermilab and Argonne. The processing recipes implemented for these structures will incorporate state-of-the art processing and cleaning techniques developed for 1.3 GHz SRF cavities for the ILC, XFEL, and LCLS-II projects. This paper describes the details of the processing recipes and associated chemistry, heat treatment, and cleanroom processes at the Fermilab and Argonne cavity processing facilities. This paper also presents single and multi-cell cavity test results with quality factors above 5·10¹⁰ and accelerating gradients above 30 MV/m.

43 PARTICLE ACCELERATORS↗

Experimental Study of Nucleation for Nb3Sn Diffusion Coatings on Niobium SRF cavities

Nb3Sn has the potential to achieve superior performance both in terms quality factor and accelerating gradient resulting in significant reduction in both initial and operating costs of SRF linacs. Cavity interior surface coatings are obtained by two-step vapor diffusion: nucleation followed by deposition. To gain more understanding of nucleation and its effect on the subsequent coating, we investigated the effect of varying parameters in a typical tin/tin chloride process. We report findings obtained by SEM/EDS, AFM, SAM and other materials characterization approaches.

Pudasaini, Uttar↗