Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile

Quantum cascade lasers (QCLs) are unipolar semiconductor lasers, where the wavelength of emitted radiation is determined by the engineering of quantum states within the conduction band in coupled multiple-quantum-well heterostructures to have the desired energy separation. The recent development of terahertz QCLs has provided a new generation of solid-state sources for radiation in the terahertz frequency range. Terahertz QCLs have been demonstrated from 0.84 to 5.0 THz both in pulsed mode and continuous wave mode (CW mode). The approach employs a resonant-phonon depopulation concept. The metal-metal (MM) waveguide fabrication is performed using Cu-Cu thermo-compression bonding to bond the GaAs/AlGaAs epitaxial layer to a GaAs receptor wafer.

Chattopadhyay, Goutam↗

NASA Propulsion Sub-System Concept Studies and Risk Reduction Activities for Resource Prospector Lander

NASA's exploration roadmap is focused on developing technologies and performing precursor missions to advance the state of the art for eventual human missions to Mars. One of the key components of this roadmap is various robotic missions to Near-Earth Objects, the Moon, and Mars to fill in some of the strategic knowledge gaps. The Resource Prospector (RP) project is one of these robotic precursor activities in the roadmap. RP is a multi-center and multi-institution project to investigate the polar regions of the Moon in search of volatiles. The mission is rated Class D and is approximately 10 days, assuming a five day direct Earth to Moon transfer. Because of the mission cost constraint, a trade study of the propulsion concepts was conducted with a focus on available low-cost hardware for reducing cost in development, while technical risk, system mass, and technology advancement requirements were also taken into consideration. The propulsion system for the lander is composed of a braking stage providing a high thrust to match the lander's velocity with the lunar surface and a lander stage performing the final lunar descent. For the braking stage, liquid oxygen (LOX) and liquid methane (LCH4) propulsion systems, derived from the Morpheus experimental lander, and storable bi-propellant systems, including the 4th stage Peacekeeper (PK) propulsion components and Space Shuttle orbital maneuvering engine (OME), and a solid motor were considered for the study. For the lander stage, the trade study included miniaturized Divert Attitude Control System (DACS) thrusters (Missile Defense Agency (MDA) heritage), their enhanced thruster versions, ISE-100 and ISE-5, and commercial-off-the-shelf (COTS) hardware. The lowest cost configuration of using the solid motor and the PK components while meeting the requirements was selected. The reference concept of the lander is shown in Figure 1. In the current reference configuration, the solid stage is the primary provider of delta-V. It will generate 15,000-lbf of thrust with a single burn of ~ 80's seconds. The lander stage is a bi-propellant, pressure-regulated, pulsing liquid propulsion system to perform all other functions.

Trinh, Huu P.↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Method for ambiguity resolution in range-Doppler measurements

A method for resolving range and Doppler target ambiguities when the target has substantial range or has a high relative velocity in which a first signal is generated and a second signal is also generated which is coherent with the first signal but at a slightly different frequency such that there exists a difference in frequency between these two signals of Delta f(sub t). The first and second signals are converted into a dual-frequency pulsed signal, amplified, and the dual-frequency pulsed signal is transmitted towards a target. A reflected dual-frequency signal is received from the target, amplified, and changed to an intermediate dual-frequency signal. The intermediate dual-frequency signal is amplified, with extracting of a shifted difference frequency Delta f(sub r) from the amplified intermediate dual-frequency signal done by a nonlinear detector. The final step is generating two quadrature signals from the difference frequency Delta f(sub t) and the shifted difference frequency Delta f(sub r) and processing the two quadrature signals to determine range and Doppler information of the target.

Heymsfield, Gerald M.↗

Flywheel-powered X-ray generator

The use of a small flywheel appears to be a practical alternative to other power sources for mobile X-ray system applications. A 5 kg flywheel has been constructed which runs at 10 krpm and stores 30 KJ while requiring less than 500 W to bring the system up to speed. The wheel is coupled to an aircraft alternator and can yield pulsed power levels over 50 KWp. The aircraft alternator has the advantage of high frequency output which has also permitted the design of smaller high voltage transformers. A series of optical sensors detecting shaft position function as an electronic commutator so that the alternator may operate as a motor to bring the wheel up to operating speed. The system permits the generation of extremely powerful X-rays from a variety of low power sources such as household power outlets, automobile batteries or sources of poorly regulated electrical power such as those found in third world countries.

Siedband, M. P.↗

Interference of Backscatter from Two Droplets in a Focused Continuous Wave CO2 Doppler Lidar Beam

Interference due to the superposition of backscatter, beta, from two micron-sized droplets using a NASA/MSFC cw (continuous wave) CO2 Doppler lidar at 9.1 micrometer wavelength was detected for the first time. The resultant single beta signal from both droplets contained an interference structure with a well-defined periodicity which was accurately measured and compared with cw lidar theory. The agreement between measurements and theory is excellent, indicating that the interference arises because the droplets are moving at different speeds and, therefore, the relative droplet separation is not constant. This gives the superimposed beta signal from both droplets in the lidar beam moving in and out of constructive and destructive interference with a well-defined periodic structure. A measurement of a time-resolved signal pulse with an oscilloscope of the combined from two approx. 14.12 micrometers in diameter silicone oil droplets responding to the Gaussian lidar beam intensity at the lidar beam focus is shown. Full details of this laboratory experimental setup, particle generation method, measurement technique, and the cw lidar can be found elsewhere. The stream of silicone oil droplets resided at a Doppler-shift center frequency of f (sub D) approx. (3.4 plus or minus 0.2) MHz, giving droplet speed v approx.(21.9 plus or minus 1.3) ms (exp. -1). Also shown on a separate channel is the corresponding signature using an amplitude demodulator circuit designed to detect the amplitude envelope of f(sub D) within the pulse profile. beta from simultaneous droplet events show a complete cyclic interference structure of maximum and minimum. The average period T of the complete cycle of interference is 13.02 plus or minus.39 microseconds. Toward the right edge of the profile, the interference disappears because one of the droplets is leaving the lidar beam while the other one remains in the beam, thus, giving beta for a single droplet.

Jarzembski, Maurice A.↗

An improved pulse-height analyzer for energetic particle measurements in the upper atmosphere

An energetic particle spectrometer for measurements in the upper atmosphere by rocket is described. The system has two methods of processing data. One is a staircase generator using threshold detectors; the other is a peak detector. The system incorporates a logarithmic converter for better resolution at low amplitudes and better use of telemetry channels. The circuits are described and calibration procedures are given. Modifications are recommended for high flux environments. Appendices cover sampling error in the peak detector and modifications made to the receiver of the propagation experiment.

Dean, L.↗

Method of measuring the thickness of radioactive thin films

Thickness monitor consists of proportional X-ray counter coupled to pulse counting system, copper filter over face of counter, rotatable collimator containing radioactive source, and rotatable shutter. Monitor can be used as integral part of neutron generator. It has been used to measure titanium tritide film thicknesses from 0.1 to 30 micrometers.

Alger, D. L.↗

Burst simulator for laser-Doppler velocimeter

Device allows for precheck of velocimeter electronics. Device uses voltage-controlled oscillators to generate fundamental frequency and pedestal frequency independently. Magnitude of each signal is adjustable. System allows variable asymmetry in burst signal to point of producing "double-pulse burst."

Youngbluth, O., Jr.↗

Silicon solar cells by high-speed low-temperature processing

A new method for silicon solar cell fabrication is being developed around ion implantation and pulsed electron beam techniques. Cells are fabricated totally in a vacuum environment at room temperature. Major reductions result in the time, energy consumption, and waste material generation associated with solar cell production. Cells to date have exhibited air mass zero efficiencies exceeding 10 percent.

Kirkpatrick, A. R.↗

U.S. welding technology - Constraints to space implementation

U.S. and European efforts to develop welding techniques for satellite solar arrays are described. Soldering practices in the U.S. have benefitted from Mo solders, which are well fitted to Si solar cell material thermal characteristics. Analyses have indicated that welds are the preferred method for interconnections and bonds. Extensive work has been done with the parallel gap resistance method (RW), which involves process heat generated by passing a current through resistive layers. Confining the primary heat input to the interconnector/cell contact interface results in welds being formed beneath both electrodes. Pulse welding has become the dominant RW technique in Europe, while ultrasonic welding is used in the U.S.; silver is employed as the interconnect material on both continents. The bonding techniques have been developed empirically instead of theoretically. An IR inspection technique has been produced for monitoring the weld temperature.

Stella, P. M.↗

Method of and apparatus for double-exposure holographic interferometry

Double-exposure holographic interferometry is carried out using first and second lasers responsive to respective applied firing signals for producing respective pulsed output beams. An optical system is provided oriented such that the output beams of the lasers produce coinciding scene and reference beams. An initiator circuit generates and applies a firing signal to the first laser; and a timer/firing device responsive to the generation of a firing signal by the initiator circuit, generates and applies a firing signal to the second laser a predetermined period of time later.

Witherow, W. K.↗

A Unique Photon Bombardment System for Space Applications

The innovative Electromagnetic Radiation Collection and Concentration System (EMRCCS) described is the foundation for the development of a multiplicity of space and terrestrial system formats. The system capability allows its use in the visual, infrared, and ultraviolet ranges of the spectrum for EM collection, concentration, source/receptor tracking, and targeting. The nonimaging modular optical system uses a physically static position aperture for EM radiation collection. Folded optics provide the concentration of the radiation and source autotracking. The collected and concentrated electromagnetic radiation is utilized in many applications, e.g., solar spectrum in thermal and associative photon bombardment applications for hazardous waste management, water purification, metal hardening, hydrogen generation, photovoltaics, etc., in both space and terrestrial segment utilization. Additionally, at the high end of the concentration capability range, i.e., 60,000+, a solar-pulsed laser system is possible.

Klein, E. J.↗

Pulsed Magnetic Field Driven Gas Core Reactors for Space Power & Propulsion Applications

The present results indicated that: 1. A pulsed magnetic driven fission power concept, PMD-GCR is developed for closed (NER) and semi-open (NTR) operations. 2. In power mode, power is generated at alpha less than 1 for power levels of hundreds of KW or higher 3. IN semi open NTR mode, PMD-GCR generates thrust at I(sub sp) approx. 5,000 s and jet power approx. 5KW/Kg. 4. PMD-GCR is highly subcritical and is actively driven to critically. 5. Parallel path with fusion R&D needs in many areas including magnet and plasma.

Anghaie, Samim↗

Observation of Dust Stream Formation Produced by Low Current, High Voltage Cathode Spots

Macro-particle acceleration driven by low current, high voltage cathode spots has been investigated. The phenomenon was observed to occur when nanometer and micrometer-sized particles in the presence of a discharge plasma were exposed to a high voltage pulse. The negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provides the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. The particle impact craters observed at the surface of downstream witness badges were documented using SEM and light microscopy.

Foster, John E.↗

Chromosome map of the thermophilic archaebacterium Thermococcus celer

A physical map for the chromosome of the thermophilic archaebacterium Thermococcus celer Vu13 has been constructed. Thirty-four restriction endonucleases were tested for their ability to generate large restriction fragments from the chromosome of T. celer. Of these, the enzymes NheI, SpeI, and XbaI yielded the fewest fragments when analyzed by pulsed-field electrophoresis. NheI and SpeI each gave 5 fragments, while XbaI gave 12. The size of the T. celer chromosome was determined from the sum of the apparent sizes of restriction fragments derived from single and double digests by using these enzymes and was found to be 1,890 +/- 27 kilobase pairs. Partial and complete digests allowed the order of all but three small (less than 15 kilobase pairs) fragments to be deduced. These three fragments were assigned positions by using hybridization probes derived from these restriction fragments. The positions of the other fragments were confirmed by using hybridization probes derived in the same manner. The positions of the 5S, 16S, and 23S rRNA genes as well as the 7S RNA gene were located on this map by using cloned portions of these genes as hybridization probes. The 5S rRNA gene was localized 48 to 196 kilobases from the 5' end of the 16S gene. The 7S RNA gene was localized 190 to 504 kilobases from the 3' end of the 23S gene. These analyses demonstrated that the chromosome of T. celer is a single, circular DNA molecule. This is the first such demonstration of the structure of an archaebacterial chromosome.

Non-NASA Center↗