Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power System Operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

Toward Energy-Efficient HPC: Insights from Power Profiling a Cloud-Resolving Earth System Model

Power is a fundamental constraint as supercomputing advances to exascale. Efficient operation within strict power budgets requires application-aware power management based on a detailed understanding of application-level power behavior. This work analyzes the Energy Exascale Earth System Model (E3SM) atmosphere component, SCREAM, on Perlmutter (NERSC) and Frontier (OLCF). We characterize power variation across inputs, concurrency levels, and power caps, evaluate the energy impact of code optimizations, and attribute energy within the code using a newly developed GPU energy model. Results show that SCREAM’s peak power remains stable during its core execution phase and decreases gradually as concurrency increases. Power capping experiments reveal a performance–energy "sweet spot". On Perlmutter, limiting GPU power to 50% of thermal design power (TDP) achieves up to 15% energy savings with a 7% performance penalty. On Frontier, a 40% TDP cap yields up to 10% energy savings with less than 10% performance loss. Code optimizations reduce SCREAM energy by shortening run time without increasing power. Modeling reveals a critical insight: data movement accounts for approximately 70% of SCREAM’s GPU energy. This fundamentally shifts the optimization focus from FLOPS to data transfer reduction for this class of applications, offering the most impactful strategy for improving energy efficiency. This work establishes a foundation for practical, application-aware power management at exascale.

Zhao, Zhengji [Lawrence Berkeley National Laborato↗

FALCON: Framework for Anomaly Detection in Industrial Control Systems

Industrial Control Systems (ICS) are used to control physical processes in critical infrastructure. These systems are used in a wide variety of operations such as water treatment, power generation and distribution, and manufacturing. While the safety and security of these systems are of serious concern, recent reports have shown an increase in targeted attacks aimed at manipulating physical processes to cause catastrophic consequences. This trend emphasizes the need for algorithms and tools that provide resilient and smart attack detection mechanisms to protect ICS. In this paper, we propose an anomaly detection framework for ICS based on a deep neural network. The proposed methodology uses dilated convolution and long short-term memory (LSTM) layers to learn temporal as well as long term dependencies within sensor and actuator data in an ICS. The sensor/actuator data are passed through a unique feature engineering pipeline where wavelet transformation is applied to the sensor signals to extract features that are fed into the model. Additionally, this paper explores four variations of supervised deep learning models, as well as an unsupervised support vector machine (SVM) model for this problem. The proposed framework is validated on Secure Water Treatment testbed results. This framework detects more attacks in a shorter period of time than previously published methods.

97 - MATHEMATICS AND COMPUTING↗

A Tradeoff Analysis of Series / Parallel Three-Phase Converter Topologies for Wireless Extreme Chargers

In this paper, extreme fast charging (XFC) technology is studied considering the charge rates of 300 kW for wireless power transfer (WPT) applications. Tradeoff analysis of series and parallel connection of three-phase WPT system are presented by comparisons of voltage and current stresses on power electronics active / passive components. In addition, star (Y) / delta (Δ) connection configurations for three-phase wireless power transfer coupling coils are analyzed with series and LCC resonant compensation circuits. The system series and parallel connection controllability is also reviewed considering voltage and current balance techniques with output control. In a conclusion of evaluation analysis, it is revealed that each component of 300 kW wireless charging network must be designed for high fast charging system and the overall system operation need to be strategically planned for high power charging and infrastructure deployment.

Asa, Erdem↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

Power Generation Enhancement through Latching Control for a Sliding Magnet-Based Wave Energy Converter

A Surface-Riding Wave Energy Converter (SR-WEC) featuring a sliding magnet inside a pitching cylindrical hull is investigated as an easily deployable small power device to support small-scale marine operations. This study extends the earlier development of the system by authors to enhance power performance through the application of end spring and latching control. The inclusion of springs at the tube’s end enhances the magnet release and travel speeds as well as the average power output compared to systems without them. Further improvement of power output can also be achieved by employing optimal latching control. We introduced constant-angle and variable-angle unlatching strategies to determine optimal parameters in combination with passive and reactive power take-off (PTO) controls to assess their effectiveness. The optimized latching control and end spring can increase 60–80% more power output compared with the case without them under certain PTO damping. Additionally, we discussed the effects of limiting peak powers and associated energy leaks with latching.

Lee, Yongseok↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Survey of Cybersecurity Governance, Threats, and Countermeasures for the Power Grid

The convergence of Information Technologies and Operational Technology systems in industrial networks presents many challenges related to availability, integrity, and confidentiality. In this paper, we evaluate the various cybersecurity risks in industrial control systems and how they may affect these areas of concern, with a particular focus on energy-sector Operational Technology systems. There are multiple threats and countermeasures that Operational Technology and Information Technology systems share. Since Information Technology cybersecurity is a relatively mature field, this paper emphasizes on threats with particular applicability to Operational Technology and their respective countermeasures. We identify regulations, standards, frameworks and typical system architectures associated with this domain. We review relevant challenges, threats, and countermeasures, as well as critical differences in priorities between Information and Operational Technology cybersecurity efforts and implications. These results are then examined against the recommended National Institute of Standards and Technology framework for gap analysis to provide a complete approach to energy sector cybersecurity. We provide analysis of countermeasure implementation to align with the continuous functions recommended for a sound cybersecurity framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulation of the Multi-Wake Evolution of Two Sandia National Labs/National Rotor Testbed Turbines Operating in a Tandem Layout

The future of wind power systems deployment is in the form of wind farms comprised of scores of such large turbines, most likely at offshore locations. Individual turbines have grown in span from a few tens of meters to today’s large turbines with rotor diameters that dwarf even the largest commercial aircraft. These massive dynamical systems present unique challenges at scales unparalleled in prior applications of wind science research. Fundamental to this effort is the understanding of the wind turbine wake and its evolution. Furthermore, the optimization of the entire wind farm depends on the evolution of the wakes of different turbines and their interactions within the wind farm. In this article, we use the capabilities of the Common ODE Framework (CODEF) model for the analysis of the effects of wake–rotor and wake-to-wake interactions between two turbines situated in a tandem layout fully and partially aligned with the incoming wind. These experiments were conducted in the context of a research project supported by the National Rotor Testbed (NRT) program of Sandia National Labs (SNL). Results are presented for a layout which emulates the turbine interspace and relative turbine emplacement found at SNL’s Scaled Wind Technologies Facility (SWiFT), located in Lubbock, Texas. The evolution of the twin-wake interaction generates a very rich series of secondary transitions in the vortex structure of the combined wake. These ultimately affect the wake’s axial velocity patterns, altering the position, number, intensity, and shape of localized velocity-deficit zones in the wake’s cross-section. This complex distribution of axial velocity patterns has the capacity to substantially affect the power output, peak loads, fatigue damage, and aeroelastic stability of turbines located in subsequent rows downstream on the farm.

Baruah, Apurva (ORCID:0000000252354068)↗

Energy storage-based packetized delivery of electricity

Systems and methods for Energy Storage-based Packetized Delivery of Electricity (ES-PDE) are disclosed that are radically different from the operation of today's grid. Using ES-PDE, the loads are powered by the energy storage systems (ESS) the majority of the time and only receive packets of electricity periodically to charge the ESSs. Therefore, the grid operators can schedule the delivery of electricity packets to utilize the existing grid infrastructure. Since the customers are powered by the co-located ESSs they are not impacted by the grid operation in short term. Therefore, when grid outages occur, the customers still have power for some time, giving the grid more time to be fully restored.

Nguyen, Tu Anh↗

Data-driven Resilience Characterization of Control Dynamical Systems

In this paper, we define and quantify resiliency of a power network and propose data-driven algorithms for computing the same for the power grid. To do this, we use the Koopman operator framework to lift the controlled dynamical system to an abstract (possibly higher) dimensional space, where the evolution is linear. The linear system representation allows us to relate small time local controllability and observability of a general nonlinear control system to the controllability and observability of the lifted linear system. Finally, we define the resiliency of the underlying power grid in terms of the controllability and observability gramians of the lifted linear system. We illustrate the proposed approach to compute the resiliency metrics on time-series data obtained from a microgrid.

koopman operator, resilience, control↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind-induced torsion of parabolic trough collectors in operation

Parabolic trough collector (PTC) systems, a type of concentrating solar power (CSP), use parabolic mirrors to reflect the sun's rays toward an absorber tube to heat the fluid inside. PTCs track the sun throughout the day and are sensitive to angular misalignment, which reduces optical performance. Torsion of the PTC, exacerbated by wind loading, contributes to angular misalignment, which has been quantified by previous studies using numerical simulations and experimental tests. However, angular misalignment due to torsion and wind loading has not yet been studied in an operational plant, which can experience more extreme and variable conditions. This study characterizes the angular misalignment due to torsion at three rows of the Nevada Solar One CSP plant and investigates the influence of wind loading. These findings reveal substantial torsion along the PTC support structure that depends on wind conditions and orientation. Strong winds perpendicular to the PTCs increase the median angular displacement of the outermost row by up to 18 mrad and increase the standard deviation by up to 8 mrad when compared to weak wind conditions. These findings can inform enhanced PTC design, controls and modeling that will improve the performance, reliability and bankability of future CSP plants.

14 SOLAR ENERGY↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Energy-Flow-Environment Linkage Map

Understanding how flexibility in environmental requirements can facilitate co-optimization of hydropower production outcomes and environmental outcomes is critical for future grid decision-making and operations as renewable energy resources increase. The environmental and power system outcomes connectivity linkage maps presented here provide a framework for conceptually and quantitatively linking power system outcomes to environmental outcomes through hydropower flow decisions. The Executive Summary Map serves as a starting for exploring the links between hydropower system performance outcomes and environmental outcomes. The centralized topic is “Flow from Hydropower System,” and connects the hydropower operations through “Flow through turbines” and “Non-turbine flows”, and to environmental outcomes through Reservoir elevation” and “Flow downstream of the hydropower system”. To the left of these central topics, “Hydro-mechanical operations” are linked through “Hydro-electrical operations” to “Hydropower performance outcomes” (“Reliability”, “Resilience”, “Revenue”, “Emissions”). On the right, environmental outcomes are grouped together by their physical location: “Upstream Outcomes” (“Upstream geomorphology”, “Upstream recreation”, “Upstream habitat”, “Upstream biota and biodiversity”, “Upstream water quality and greenhouse gas”), Outcomes relevant to both “Upstream/downstream or dam interface” (“Navigation”, “Dam safety and maintenance", “Human health”, “Water supply”, “Flood control”, ”Fish passage”), and “Downstream outcomes“ (e.g., “Downstream geomorphology”, “Downstream recreations”, “Downstream habitat”, “Downstream biota and biodiversity”, “Downstream water quality and greenhouse gas”). Each of these subtopics (e.g., “Hydro-mechanical operations”, “Hydro-electrical operations”, “Upstream geomorphology”, “Upstream recreation”) is further explored through their corresponding submaps. The “Read Me” file provides more detail information on map navigation. The “Models and tools database” file provides detailed information of models and tools presented in the maps.

13 HYDRO ENERGY↗