Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power System Dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Dynamic Multiplexed Control and Modeling of Optogenetic Systems Using the High-Throughput Optogenetic Platform, Lustro

The ability to control cellular processes using optogenetics is inducer-limited, with most optogenetic systems responding to blue light. To address this limitation, we leverage an integrated framework combining Lustro, a powerful high-throughput optogenetics platform, and machine learning tools to enable multiplexed control over blue light-sensitive optogenetic systems. Specifically, we identify light induction conditions for sequential activation as well as preferential activation and switching between pairs of light-sensitive split transcription factors in the budding yeast, Saccharomyces cerevisiae. We use the high-throughput data generated from Lustro to build a Bayesian optimization framework that incorporates data-driven learning, uncertainty quantification, and experimental design to enable the prediction of system behavior and the identification of optimal conditions for multiplexed control. This work lays the foundation for designing more advanced synthetic biological circuits incorporating optogenetics, where multiple circuit components can be controlled using designer light induction programs, with broad implications for biotechnology and bioengineering.

59 BASIC BIOLOGICAL SCIENCES↗

Century: Zap Energy’s 100-kW-Scale Repetitive Sheared-Flow-Stabilized Z -Pinch System with Liquid Metal Cooling

Zap Energy is developing the sheared-flow-stabilized (SFS) Z-pinch concept for commercial applications. The SFS Z pinch relies on plasma self-organization, in the sense that plasma dynamics play a critical role in confinement. Using plasma axial current for confinement and compression eliminates the need for external confinement or heating technologies. This compact magnetic confinement technology could, in turn, provide the basis for a cost-effective deuterium-tritium fusion power plant. In addition to a robust experimental program pushing plasma performance towards breakeven conditions, Zap Energy has parallel programs developing power handling systems suitable for future power plants. Technologies under development include high average-power repetitive pulsed power, high duty-cycle cathodes, and liquid metal wall systems. Century is the name of Zap Energy’s first effort to integrate these three components into an operational system capable of firing non-reacting hydrogen SFS Z-pinch plasmas into a liquid-metal-lined container at sustained repetition rates on the order of 0.1 Hz. Here, the pulsed power driver and liquid metal heat exchanger are both designed to sustain input powers of 100 kW. Construction and initial operations with an interim ~10 kW liquid metal heat exchanger are described.

Century↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Technical Characterization and Benefit Evaluation of 5G-Enabled Grid Data Transport and Applications

This report summarizes the Year 1 work of Pacific Northwest National Laboratory’s (PNNL’s) 5G Fabricated Resource and Asset Management Encompassment for energy infrastructure (Energy FRAME) project funded by the Department of Energy Office of Science’s Advanced Scientific Computing Research Program. 5G is a breakthrough technology that enables a fully mobile and connected society, and a 5G-enabled digital continuum will be one of the critical foundations for a clean energy economy and grid modernization. In collaboration with PNNL’s Advanced Wireless Communication team and Center for Advanced Technology Evaluation team, the project team has been evaluating the system performance of 5G testbeds in the PNNL 5G Innovation Studio, and has formulated a co-simulation test case of power system transmission, distribution, and communication (T&D&C) networks considering 5G technology and high penetration of distributed energy resources. The methodology developed in the 5G Energy FRAME project can be customized to fit different future grid scenarios to evaluate multiple (dynamic) configurations (computing, sensing, communication, environment) for different stakeholders. In summary, our main technical highlights in project Year 1 are as follows: 1) Technical characterization of 5G standalone architectures, 2) Formulation of co-simulation test case of T&D&C networks embedded with 5G, 3) Initial benefit evaluation of 5G communication platform for grid use cases, and 4) Additional extended discussions on edge computing, artificial intelligence and machine learning, and high-performance computing and cloud computing adoptions. In addition, a collection of system performance data is shared through the publicly available weblink, https://www.pnnl.gov/projects/5g-energy-frame/publications

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating power grid model hydropower feasibility with a river operations model

Production cost models (PCMs) simulate dispatch of generators across a large power grid and are used widely by planners to study the reliability of electricity supply. As energy systems transition away from the thermoelectric technologies that have traditionally balanced electricity supply and demand, hydropower and its representation in PCMs is of increasing importance. A limitation of PCMs applied to continental power grids with diverse generation portfolios is that hydropower generation is simulated without full consideration of complex river dynamics, leading to possible misrepresentation of grid flexibility and performance. In addition, data used in PCMs may reflect outdated operating policies. In this paper we propose a hydropower generation feasibility test for PCMs. The approach uses a detailed hydropower model to determine whether the hourly hydropower schedule from a PCM with simplified monthly parameterization can be attained after accounting for realistic river dynamics and operating policies, such as spill requirements and general water movement and balance through a cascade reservoir system. We perform this hydropower generation test for the ‘Big 10’ hydropower system on the Columbia River (part of the Western Interconnect of the United States), revealing 9% overestimation of available hydropower generation in a PCM solution in an average hydrologic year. Our evaluation provides insight on the cost and opportunities for better representing hydropower in PCMs.

54 ENVIRONMENTAL SCIENCES↗

Application of a Prize Mechanism to Address Data Utilization Challenges at Utilities

The electric industry sector is facing an “explosion” of data from a variety of sources. Electric sector stakeholders need to define how to capitalize on large datasets, both those they create and those from other sources (like data on weather, buildings, electric vehicles, etc.), to improve reliability and resilience and meet the changing system dynamics from renewable integration. For the electricity sector to fully utilize these vast new datasets, it must undergo a transformation in how it manages data quality, storage, and processing. The U.S. Department of Energy (DOE) Office of Electricity (OE) is committed to accelerating research, development, and demonstration of new technologies and tools within the electricity sector to advance reliability, resilience, and affordable operation of the power system. Through the prize mechanism, OE identified two widespread data-related challenges for utilities—load modeling and data analysis automation—and offered an opportunity for utilities and teams of software engineers to identify additional challenges faced by utilities. After completing one round of the American-Made Digitizing Utilities Prize, OE, the National Renewable Energy Laboratory (NREL) as the prize administrator, and Pacific Northwest National Laboratory (PNNL) as the domain experts have compiled the results and lessons learned to feed into the second round of the prize.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Carrier Localization and Spontaneous Formation of Two-Dimensional Polarization Domain in Halide Perovskites

Halide perovskites are known for their rich phase diagram and superior performance in diverse optoelectronics applications. The latter property is often attributed to the long electron-hole recombination time, whose underlying physical mechanism has been a long-standing controversy. In this Letter, we investigate the transport and localization properties of electron and hole carriers in a prototypical halide perovskite (CsPbBr 3 ), through ab initio tight-binding nonadiabatic dynamics approach for large-scale (tens of nm size) supercell calculations, to simulate electron and ion dynamics on the same footing. Here, we found distinct structural, lattice polarization, and electron-phonon coupling properties at low (below 100 K) and high temperatures, consistent with experimental observations. In particular, at low temperature we find spontaneous formation of polar grain boundaries in the nonpolar bulk systems, which result in two-dimensional polarization patterns that serve to localize and separate electrons and holes. We reveal phonon-assisted variable-range hopping mostly responsible for low-temperature transport, and their characteristic frequency correlates with temperature-dependent phonon power spectrum and energy oscillation frequency in nonadiabatic dynamics. We answer the critical questions of long electron-hole recombination lifetime at low temperature and offer the correlation among polarization domains, electron-phonon couplings, and photocarrier dynamics.

Carrier generation & recombination↗

Large-Signal Stability Improvement of Parallel Grid-Forming Inverter-Driven Black Start: Preprint

With the rapid increase of inverter-based resources in modern grids, advanced grid-forming (GFM) inverter capa- bilities, such as system restoration and operation under faults, are urgently needed to realize power electronics-dominant grids at scale. One such capability is inverter-driven black start using GFM inverters. This paper analyzes the ability of two recently proposed advanced GFM controls to help GFM inverters sustain system-wide, off-nominal conditions and remain synchronized until they can overcome the momentary overloading as more GFMs join the process without generator sequence coordination or communications and finally stabilize the grid. Through an extensive set of 1,200 full-order electromagnetic transient simu- lations, we evaluate the black-start process while employing the various GFM inverter controls. The results show that the GFM current limiter and primary control have a significant impact on the stability of the system during dynamic operating conditions and thus impact the success of inverter-driven system restoration.

current limit↗

From TPL assessment to design optimization: Wave energy converter control co-design applied to the RM3

The Reference Model (RM) project developed six marine energy converter concepts using a sequential design methodology, which, while widely adopted in the industry, often overlooks interactions between system components, resulting in suboptimal designs. One such example is the Reference Model 3 (RM3), a two-body point absorber wave energy converter (WEC). An assessment using the Technology Performance Level (TPL) revealed that RM3’s low power-to-cost ratio, partly due to expensive steel construction, limits its techno-economic performance. Here, this study aims to redesign RM3 by reducing its scale and employing control co-design to integrate WEC and Power Take-Off (PTO) dynamics, constraints, and cost considerations within an optimization framework. We demonstrate the limitations of RM3’s current PTO design and explore the benefits of scaling down to enhance techno-economic viability by lowering material costs. Using WecOptTool, we conduct a parameter sweep over gear ratios and spring stiffnesses for various Commercial Off-The-Shelf generators in irregular wave conditions. Our findings emphasize the importance of aligning PTO components with WEC dynamics, showing that control co-design and strategic scaling can improve RM3’s power-to-cost ratio. This study presents a transferable example of applied control co-design for other WECs, supporting early-stage developers in their design decisions.

Off the shelf components↗

Temperature and Dynamic Strain Measurements Using a Single SAWR Sensor

Dynamic strain sensing is relevant in numerous applications involving structural health monitoring, condition-based maintenance, operation efficiency preservation, and work environment safety. These sensors are particularly critical for high-temperature (HT) harsh-environment (HE) industries such as aerospace, automotive, power plants, and advanced manufacturing. In HT/HE, sensor implementation and measurement present challenges such as maintaining sensor stability, accounting for temperature cross-sensitivity, providing HT attachment, and packaging of the sensors and system. Surface acoustic wave resonator (SAWR) sensors can address these needs and offer additional benefits such as compact size and wireless interrogation capability. The SAWR sensitivity to dynamic strain is temperature dependent, making it necessary to measure the sensor temperature in order to use the correct dynamic strain calibration curve. In this work, a method for determining the temperature, dynamic strain magnitude, and dynamic strain spectral components using a single SAWR sensor is presented. Here, the established technique for determining operational temperature and dynamic strain magnitude/spectral components using only one SAWR simplifies the sensor measurement system, thus being very attractive for HT /HE applications.

47 OTHER INSTRUMENTATION↗

Dynamic Validation of CNN-Based Surrogate Models for Inverter-Based Resources in Open-Source Solvers

Traditionally, distribution system planning has focused on steady-state analyses, with limited consideration of dynamic behavior. However, as large or medium-scale inverter-based resources (IBRs), particularly grid-following (GFL) inverters in commercial or industry buildings, become more prevalent, understanding their dynamic impact is essential for grid planning and operation. This article presents an innovative deep-learning (DL)-approach using convolutional neural networks technique to model the GFL inverters. Developed from real grid-tied commercial IBR transient data, these dynamic DL models overcome proprietary constraints by requiring minimal knowledge of internal converter physics while maintaining high accuracy and flexibility. To demonstrate their applicability, the models were incorporated into GridLAB-D, an open-source, three-phase distribution analysis tool. This integration enables dynamic simulations of large-scale distribution networks with high IBR penetration stability analysis. Rigorous testing and validation, aligned with industry standards, confirmed the reliability and efficiency of this approach, paving the way for enhanced planning and operational assessments of modern power systems.

Deep-learning↗

Big Data Analytic for Cascading Failure Analysis

With the challenges of increased grid dynamics and more variability of power generation from renewable energy sources, rapidly increasing complexity in the grid model, and abundant data from measurements and simulations, the requirements for computational analysis have also increased dramatically. Power system operators and engineers need to analyze more scenarios, extract meaningful information from a larger set of data, and respond more quickly when faced with these new challenges for large-scale applications, such as contingency analysis. This paper proposes a novel big data analysis approach for power system cascading analysis, prevention, and remediation. The developed techniques will be capable of cascading analysis, better assessment of the system’s vulnerability level, as well as proposing potential remediation. Case studies using IEEE 118-bus system and a 500-bus system, with a comparison against a commercial tool, validate the advantages of the developed big data approach: accurate prediction, and more importantly, faster and effective correction actions.The developed techniques could be further used for other power system applications.

big data, cascading analysis, corrective action, m↗

Software for Transformative Remedial Action Scheme Tool (TRAST)

The transformative remedial action scheme tool (TRAST) can be applied to improve and validate the power system remedial action scheme (RAS), and further improve the performance of power system operation and control. This tool provides a full suite of advanced functionalities, which are given as follows: 1. Advanced statistical data analysis; 2. OPF-based automated power flow case generation; 3. Customized dynamic simulation in HPC/cloud platform; 4. Machine learning based RAS coefficient prediction; 5. A reliable RAS validation strategy in multiple commercial platforms.

Fan, Xiaoyuan↗

TRUST Nonlinear Dynamics Testbed Assessment

The following assessment evaluates the efficacy of the control script for carrying out a linear signal to generate a linear mechanical response of the system: the TRUST nonlinear dynamics (TRUSTND) testbed. The hardware has three main components: the controller (NI PXIe 8861) embedded in the National Instruments chassis (NI PXIe 1092), the signal amplifier (The Modal Shop Linear Power Amplifier 2050E09) to amplify the output of a custom LabVIEW script, and a shaker (The Modal Shop Electrodynamic Exciter 2075E) where wave spring specimens live and are tested within the attached aluminum testbed (center mass). Different kinds of signals (single-tone, swept frequency and white noise) were sent through this hardware in the E-1 lab space at TA-53. First, the linearity of the setup was tested by specifying a sine wave in the control script and checking the quality of the oscillations in a wave spring (McMaster-Carr 9714K19 [1]). When passing a sine wave through the amplifier was succeeded, the frequency response of the wave spring was tested with white noise for comparison to finite-element model predictions. The testbed outputs a repeatable, linear response to the input excitation when used with the wave spring. These measurements reduce the uncertainty associated with the testbed and test procedure to better characterize uncertainty associated with material behavior (SX358 foam samples) in future tests

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sink or Swim: A Tutorial on the Control of Floating Wind Turbines: Preprint

Within the rapidly growing wind energy sector, floating offshore wind turbines are expected to be the fastest growing portion. This is largely driven by the immense offshore wind resources that are mostly over deep water, where fixed-bottom concepts become cost prohibitive. However, compared to fixed-bottom wind turbines, floating wind turbines are more dynamic and exhibit potential instabilities, which requires advanced control technologies to ensure a safe and efficient operation. Beyond their existing objectives of maximizing power production while minimizing structural loads, floating wind turbine controllers must also avoid large platform oscillations and accommodate wave disturbances. This paper provides an overview of the challenges and opportunities in the control of floating offshore wind energy systems.

control↗

AI-Based Faster-Than-Real-Time Stability Assessment of Large Power Systems with Applications on WECC System

Achieving clean energy goals will require significant advances in regard to addressing the computational needs for next-generation renewable-dominated power grids. One critical obstacle that lies in the way of transitioning today’s power grid to a renewable-dominated power grid is the lack of a faster-than-real-time stability assessment technology for operating a fast-changing power grid. This paper proposes an artificial intelligence (AI) -based method that predicts the system’s stability margin information (e.g., the frequency nadir in the frequency stability assessment and the critical clearing time (CCT) value in the transient stability assessment) directly from the system operating conditions without performing the conventional time-consuming time-domain simulations over detailed dynamic models. Since the AI method shifts the majority of the computational burden to offline training, the online evaluation is extremely fast. This paper has tested the AI-based stability assessment method using multiple dispatch cases that are converted and tuned from actual dispatch cases of the Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. The results show that the AI-based method could accurately predict the stability margin of such a large power system in less than 0.2 milliseconds using the offline-trained AI agent. Therefore, the proposed method has great potential to achieve faster-than-real-time stability assessment for practical large power systems while preserving sufficient accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling system for reducing fatigue and dynamic amplification of loads in objects

A coupling system can include an energy transfer device and a load mitigation system. The energy transfer device can include a shaft, gear, chain or piston-cylinder arrangement to transfer the energy from a power supply to an object to be moved. The load mitigation system can be used to limit or prevent the transfer of forces from the object to the drive unit as a result of external loads being applied to the object. The load mitigation system can be pre-loaded such that external loads on the object having an excessive impulsive or resonant cyclic force greater than the pre-load force on the load mitigation system are reduced and only partially transferred to the energy transfer device and power supply. The load mitigation system can dampen both resonant loads and impulsive impact loads occurring at the object thereby preventing damage and extending life.

Blackmon, James B.↗