Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

James Webb Space Telescope Studies of Dark Energy

The Hubble Space Telescope (HST) has contributed significantly to studies of dark energy. It was used to find the first evidence of deceleration at z=1.8 (Riess et al. 2001) through the serendipitous discovery of a type 1a supernova (SN1a) in the Hubble Deep Field. The discovery of deceleration at z greater than 1 was confirmation that the apparent acceleration at low redshift (Riess et al. 1998; Perlmutter et al. 1999) was due to dark energy rather than observational or astrophysical effects such as systematic errors, evolution in the SN1a population or intergalactic dust. The GOODS project and associated follow-up discovered 21 SN1a, expanding on this result (Riess et al. 2007). HST has also been used to constrain cosmological parameters and dark energy through weak lensing measurements in the COSMOS survey (Massey et al 2007; Schrabback et al 2009) and strong gravitational lensing with measured time delays (Suyu et al 2010). Constraints on dark energy are often parameterized as the equation of state, w = P/p. For the cosmological constant model, w = -1 at all times; other models predict a change with time, sometimes parameterized generally as w(a) or approximated as w(sub 0)+(1-a)w(sub a), where a = (1+z)(sup -1) is the scale factor of the universe relative to its current scale. Dark energy can be constrained through several measurements. Standard candles, such as SN1a, provide a direct measurement of the luminosity distance as a function of redshift, which can be converted to H(z), the change in the Hubble constant with redshift. An analysis of weak lensing in a galaxy field can be used to derive the angular-diameter distance from the weak-lensing equation and to measure the power spectrum of dark-matter halos, which constrains the growth of structure in the Universe. Baryonic acoustic oscillations (BAO), imprinted on the distribution of matter at recombination, provide a standard rod for measuring the cosmological geometry. Strong gravitational lensing of a time-variable source gives the angular diameter distance through measured time delays of multiple images. Finally, the growth of structure can also be constrained by measuring the mass of the largest galaxy clusters over cosmic time. HST has contributed to the study of dark energy through SN1a and gravitational lensing, as discussed above. HST has also helped to characterize galaxy clusters and the HST-measured constraints on the current Hubble constant H(sub 0) are relevant to the interpretation of dark energy measurements (Riess et al 2009a). HST has not been used to constrain BAO as the large number of galaxy redshifts required, of order 100 million, is poorly matched to HST's capabilities. As the successor to HST, the James Webb Space Telescope (JWST; Gardner et al 2006) will continue and extend HST's dark energy work in several ways.

Gardner, Jonathan P.↗

Measurement accuracy of flow velocity via a digital-frequency-counter laser velocimeter processor

The laser velocimeter (LV) technique has so far been successfully applied to many flow situations to obtain mean velocity and turbulence level measurements. The paper deals with a unique LV system employing a digital frequency counter for measurements of turbulence spectra within the objectives of achieving higher accuracies and a wider range of velocities than were possible by previous analog systems. Systematic analysis of the effects of LV system errors in the accuracy of the turbulence power spectral measurements is performed and shown to agree reasonably with the experimental LV spectra results. Sufficient understanding of the accuracy and limitations of the digital frequency counter LV spectral measurement system is obtained. Among the major system errors encountered in a typical digital frequency counter LV processor, the truncation error is regarded as the most serious source of error. The quantizing step size defined as the ratio of Doppler frequency to processor clock frequency is an important parameter in determining the dynamic range of a turbulence power spectrum.

Wang, J. C. F.↗

Ground noise measurements during static and flyby operations of the Cessna 02-T turbine powered airplane

The field noise measurements on the Cessna 02-T turbine powered propeller aircraft are presented. The objective of the study was to obtain the basic noise characteristics of the aircraft during static ground runs and flyover tests, to identify the sources of the noise, and to correlate the noises with the aircraft operating conditions. The results are presented in the form of a overall noise levels, radiation patterns, and frequency spectra. The noise characteristics of the turbine powered aircraft are compared with those of the reciprocating engine powered aircraft.

Hilton, D. A.↗

Geometry versus growth: Internal consistency of the flat ΛCDM model with KiDS-1000

Here, we carry out a multi-probe self-consistency test of the flat Lambda Cold Dark Matter (ΛCDM) model with the aim of exploring potential causes of the reported tensions between high- and low-redshift cosmological observations. We divide the model into two theory regimes determined by the smooth background (geometry) and the evolution of matter density fluctuations (growth), each governed by an independent set of ΛCDM cosmological parameters. This extended model is constrained by a combination of weak gravitational lensing measurements from the Kilo-Degree Survey, galaxy clustering signatures extracted from Sloan Digital Sky Survey campaigns and the Six-Degree Field Galaxy Survey, and the angular baryon acoustic scale and the primordial scalar fluctuation power spectrum measured in Planck cosmic microwave background (CMB) data. For both the weak lensing data set individually and the combined probes, we find strong consistency between the geometry and growth parameters, as well as with the posterior of standard ΛCDM analysis. In the non-split analysis, for which one single set of parameters was used, tension in the amplitude of matter density fluctuations as measured by the parameter S 8 persists at around 3σ, with a 1.5% constraint of S 8 = 0.776$_{–0.008}^{+0.016}$ for the combined probes. We also observe a less significant preference (at least 2σ) for higher values of the Hubble constant, H 0 = 70.5$_{–1.5}^{+0.7}$ km s –1 Mpc –1 , as well as for lower values of the total matter density parameter Ω m = 0.289$_{–0.005}^{+0.007}$ compared to the full Planck analysis. Including the subset of the CMB information in the probe combination enhances these differences rather than alleviate them, which we link to the discrepancy between low and high multipoles in Planck data. Our geometry versus growth analysis does not yet yield clear signs regarding whether the origin of the discrepancies lies in ΛCDM structure growth or expansion history but holds promise as an insightful test for forthcoming, more powerful data.

79 ASTRONOMY AND ASTROPHYSICS↗

BICMOS power detector for pulsed Rf power amplifiers

A BiCMOS power detector for pulsed radio-frequency power amplifiers is proposed. Given the pulse waveform and a fraction of the power amplifier's input or output signal, the detector utilizes a low-frequency feedback loop to perform a successive approximation of the amplitude of the input signal. Upon completion of the successive approximation, the detector returns 9-bits representing the amplitude of the RF input signal. Using the pulse waveform from the power amplifier, the detector can dynamically adjust the rate of the binary search operation in order to return the updated amplitude information of the RF input signal at least every 1ms. The detector can handle pulse waveform frequencies from 50kHz to 10MHz with duty cycles in the range of 5- 50% and peak power levels of -10 to 10dBm. The signal amplitude measurement can be converted to a peak power measurement accurate to within ±0.6dB of the input RF power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Experimental investigation of microwave interaction with magnetoplasma in miniature multipolar configuration using impedance measurements

A miniature microwave plasma source employing both radial and axial magnetic fields for plasma confinement has been developed for micro-propulsion applications. Plasma is initiated by launching microwaves via a short monopole antenna to circumvent geometrical cutoff limitations. The amplitude and phase of the forward and reflected microwave power is measured to obtain the complex reflection coefficient from which the equivalent impedance of the plasma source is determined. Effect of critical plasma density condition is reflected in the measurements and provides insight into the working of the miniature plasma source. A basic impedance calculation model is developed to help in understanding the experimental observations. From experiment and theory, it is seen that the equivalent impedance magnitude is controlled by the coaxial discharge boundary conditions, and the phase is influenced primarily by the plasma immersed antenna impedance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pipe flow measurements of turbulence and ambiguity using laser-Doppler velocimetry

The laser-Doppler ambiguities predicted by George and Lumley (1973) have been verified experimentally for turbulent pipe flows. Experiments were performed at Reynolds numbers from 5000 to 15,000 at the center line and near the wall. Ambiguity levels were measured from power spectral densities of FM demodulated laser signals and were compared with calculations based on the theory. The turbulent spectra for these water flows after accounting for the ambiguity were equivalent to hot-film measurements at similar Reynolds numbers. The feasibility of laser-Doppler measurements very close to the wall in shear flows is demonstrated.

Berman, N. S.↗

Propulsion System Testing for the Iodine Satellite (iSAT) Demonstration Mission

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. 3, 4 Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature (less than 100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at −75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. An iodine-based system is not without its challenges. The primary challenge is that the entire feed system must be maintained at an elevated temperature to prevent the iodine from depositing (transitioning from the gas phase directly back into the solid phase), which will block the propellant feed lines. Furthermore, deposition will occur unless the temperature in the lines is not greater than the temperature of the propellant reservoir. The flow rate can be controlled by adjusting the heating applied to the reservoir, but as with any thermal control there is a relatively slow response to changes in the heating rate. In the present paper, we describe the propulsion and propellant feed system for the iodine satellite (iSAT) flight demonstration mission. The system is based around the Busek BHT-200 Hall thruster, which has been modified for chemical compatibility with iodine vapor. While the gross propellant flow rate is maintained by the heated propellant reservoir, the flow to the anode and cathode are adjusted using two heated Vacco proportional flow control valves (PFCV), which provide very fast response on the flow rate adjustment. The flight mission design layout will be presented, showing how the system will be packaged into the overall 12-U spacecraft and the techniques being employed to protect the remaining spacecraft hardware from the propulsion system (e.g., plasma impingement, iodine deposition, thermal loads). In addition to the flight system design, results of testing the thruster and cathode with both operating on iodine propellant are presented. The tests are conducted on a thrust stand (see Fig. 1) in a large vacuum chamber containing a beam dump chilled to below -100 C to 'cryopump' the propellant. The thruster performance during these tests is presented, with these data used to evaluate the feed system and guide further refinements. Results of relatively long duration testing are presented to demonstrate the capability to operate for the length of the iSAT mission and to perform a number of re-starts as will be required by the mission concept of operations.

Polzin, Kurt A.↗

Engineering Model Propellant Feed System Development for an Iodine Hall Thruster Demonstration Mission

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cu cm and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high (Delta)v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. 3, 4 Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature (< 100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp −6) torr at −75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. In the present paper, we describe the design and testing of the engineering model propellant feed system for iSAT (see Fig. 1). The feed system is based around an iodine propellant reservoir and two proportional control valves (PFCVs) that meter the iodine flow to the cathode and anode. The flow is split upstream of the PFCVs to both components can be fed from a common reservoir. Testing of the reservoir is reported to demonstrate that the design is capable of delivering the required propellant flow rates to operate the thruster. The tubing and reservoir are fabricated from hastelloy to resist corrosion by the heated gaseous iodine propellant. The reservoir, tubing, and PFCVs are heated to ensure the sublimed propellant will not re-deposit within the feed system. Heating is accomplished through a number of individual zones to control the overall power expended on heating the system and insulation is employed to minimize the amount of power used to heat the system prior to thruster operation.

Polzin, Kurt A.↗

Use of satellites to determine optimum locations for solar power stations

Ground measurements of solar radiation are too sparse to determine important mesoscale differences that can be of major significance in solar power station locations. Cloud images in the visual spectrum from the SMS/GOES geostationary satellites are used to determine the hourly distribution of sunshine on a mesoscale in the continental United States excluding Alaska. Cloud coverage and density as a function of time of day and season are considered through the use of digital data processing techniques. Low density cirrus clouds are less detrimental to solar energy collection than other types; and clouds in the morning and evening are less detrimental than those during midday hours of maximum insolation. The seasonal geographic distributions of sunshine are converted to Langleys of solar radiation received at the earth's surface through the use of transform equations developed from long-term measurements of these two parameters at 18 widely distributed stations. The high correlation between measurements of sunshine and radiation makes this possible. The output product will be maps showing the geographic distribution of total solar radiation on the mesoscale which is received at the earth's surface during each season.

Hiser, H. W.↗

Power Plant Water Risk and Adaptive Measures Database

Project objective was to understand water-related constraints affecting conventional powerplant operations, specifically coal-fired power plants. Of concern were threats related to drought and flood affecting both water supply and ability of plant to discharge wastewater. Also of interest were adaptive measures taken to mitigate identified threats. This spreadsheet contains the responses provided by the power plant operators and owners. Data have been "sanitized" (e.g., random plant ID, binned location and generation capacity information) to ensure anonymity of individual power plants.

Adaptive Measures↗

Human Performance Measures for the Evaluation of Nuclear Power Plant Control Room Interfaces: A Systematic Review - 265

The purpose of this study was to review the literature related to measuring human performance in the design and evaluation of the human-system interface (HSI) of nuclear power plant (NPP) control rooms and synthesize lessons learned and future directions for research and practice in this field. The design and evaluation of digital or hybrid HSI requires comprehensive measurement of human performance to ensure quality and safety of the nuclear power process control. Human factors evaluation frameworks have been proposed to guide the measurement of human performance constructs. However, there are few guides for selecting appropriate measures for those constructs. A systematic review of empirical research literature was conducted. Studies were identified through academic publication databases and grey literature searches. Eligible studies were coded and information regarding human performance measures was extracted and analyzed. A total of 80 studies met the criteria. Human performance measures extracted from the reviewed studies included measures of: behavioral performance; workload; situation awareness; human-human or human-machine cooperation; other cognitive performance indicators; and system performance. Behavioral performance (speed and accuracy), workload, and situation awareness were the most frequently measured constructs with validated and domain-specific instruments. The results of the literature review provided an overview of the human performance constructs and their corresponding measures for NPP control room HSI evaluation. These results can be used as an initial guide to establish appropriate and comprehensive measurements of human performance for such evaluations. Future directions in measure development are also discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Density fluctuation measurements by far-forward collective scattering in the MST reversed-field pinch

The multichannel polarimeter-interferometer system on the MST reversed-field pinch can be utilized to measure far-forward collective scattering from electron density fluctuations. The collective scattering system has 11 viewing chords with {approx}8 cm spacing. The source is a 432 {mu}m (694 GHz) far infrared laser and the scattered power is measured using a heterodyne detection scheme. Collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wavenumber range: k{sub Up-Tack} < 1.3 cm{sup -1}, corresponding k{sub Up-Tack }{rho}{sub s} < 1.3 ({rho}{sub s} is the ion-sound Larmor radius), the region of primary interest for turbulent fluctuation-induced transport. The perpendicular wavenumber consists of toroidal, poloidal, and radial contributions, which vary with chord position. Coherent modes associated with tearing instabilities and neutral-beam driven fast particles are observed along with broadband turbulence at frequencies up to 500 kHz. Changes in frequency are consistent with a Doppler shift due to parallel plasma flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Far-forward collective scattering measurements by FIR polarimeter-interferometer on J-TEXT tokamak

The multi-channel three-wave polarimeter-interferometer system on J-TEXT tokamak has been exploited to measure far-forward collective scattering from electron density fluctuations. The diagnostic utilizes far infrared lasers operated at 432 μm with 17-channel vertical chords (3 cm chord spacing), covering the entire cross section of plasma. Scattering laser power is measured using a high-sensitivity Schottky planar diode mixer which can also detect polarimetric and interferometric phase simultaneously. The system provides a line-integrated measurement of density fluctuations with maximum measurable wave number: k{sub ⊥max} ≤ 2 cm{sup −1} and time response up to 350 kHz. Feasibility of the diagnostic has been tested, showing higher sensitivity to detect fluctuation than interferometric measurement. Capability of providing spatial-resolved information of fluctuation has also been demonstrated in preliminary experimental applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristic Ultraviolet/Optical Timescales in Active Galactic Nuclei

The UV/optical light curves of active galactic nuclei (AGNs) may be roughly characterized by a periodic fractional flux variations of approx. 10% on timescales of 1 month. The physical mechanism(s) responsible remain ill defined. We present a structure function analysis, i.e., measure the power distribution over a range of timescales tau, of 13 AGNs to constrain the origin of UV/optical emission. On timescales tau approx. 5- 60 days, the mean UV and optical power density spectra (PDS) are equivalent. This may suggest that the underlying energy generating mechanism is identical. The combined W/optical PDS is P(f) proportional to f(sup -alpha)- with alpha = 2.13(sup +0.22, sub -0.06). For sources with measured X-ray PDS indices, we find they are indistinguishable from their UV/optical counterparts. This supports scenarios whereby X-rays are generated via Compton upscattering of UV photons, to later radiatively drive optical variations. At the same time, we present evidence for characteristic variability timescales tau(sub char) of approx. 5-100 days in 10 sources. These variability timescales combined with reverberation based masses M suggest a M - tau(sub char) relationship; higher mass systems have larger characteristic timescales. The UV tau(sub char) may possibly reflect dynamical or accretion disk thermal timescales. We find suggestive evidence for a dichotomy, at tau approx. 30 days and M approx. l0(exp 7) solar mass, between short- and long-time scale optical variations. These optical variations may be attributable to dynamical and accretion disk thermal or starburst activity timescales, respectively.

Collier, Stefan↗

Data assimilation for burnup distribution of PWR with three-dimensional variational algorithm and artificial neutral network

In this paper, a data-assimilation method has been proposed and applied for the burnup distribution of PWR. The burnup distribution is significant to the safety and economy of the reactor, as it is essential for the fuel-reloading design and optimization. Due to the burnup distribution cannot be measured directly during the reactor operation, the numerical simulation is widely applied to determine the burnup distribution. However, there is a deviation between the numerical simulation and the actual core due to some unavoidable factors, such as component manufacturing deviation, uneven flow distribution and so on. These differences would induce the errors to the simulation values of power distributions and hence to the burnup distribution. To address this problem, a data-assimilation method for the burnup distribution has been proposed with the application of power-distribution measurements. In our research, the three-dimensional variational (3DVAR) algorithm was applied for burnup-distribution calibration and the artificial neutral network (ANN) was applied to establish the relation between power distribution and corresponding burnup distribution. As engineering verification, the proposed data-assimilation method has been applied to the CNP1000 PWR operated in China. The numerical results indicated that the burnup-distribution errors can be reduced notably, as the maximum value of relative errors for power distribution can be reduced from 5.35% to 3.96%. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗