Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

947 records · Page 53

Solar Microflare with BATSE

Our work on detecting and cataloging solar microflares using an automated method is illustrated in the accompanying figure. The figure represents the solar microflare distribution during the period of April 1991 to November 1992, the height of solar activity after the launch of The Compton Gamma Ray Observatory (CGRO). It also shows the distribution extending below the distribution obtained at Goddard Space Flight Center (GSFC) by manual means. We have implemented significant refinements in the search algorithm. The algorithm in its simplest form searches for transient events and based upon the distribution of the signal among the different Burst and Transient Source Experiment (BATSE) detectors, we can assign it to be of solar origin if the signal distribution conforms to what one expects from a burst or transient from that direction. One of the major problems in the earlier effort was to search for microflares and large flares simultaneously. The requirement for a dynamic range of almost 10 (exp 4) resulted in ambiguous identifications at the low side of the distribution. We have since restricted the search to events with peak count rates under 2000 s (exp -1). Larger events are easily identified in the manual search, so we have chosen not to duplicate that work. The second problem was that missing counts existed below channel 0 in the Burst and Transient Source Experiment Large Area Detector data (BATSE LAD). These have been recovered and are now included in the search process. This provides data below 20 keV, and as we get closer to the thermal part of the spectrum, it provides greater sensitivity. The third problem was that too many BATSE detector were used in the search. Detectors with pointing directions far from the Sun, although detecting the event, had poorly known responses. Detectors greater than approximately 60 deg. off the Sun are no longer included in the search process. By reducing the systematic errors with the large off-axis detectors we can conduct more rigorous statistical tests of a candidate event to ascertain whether it originated from the solar direction. We have reprocessed the period in the early mission that covers solar maximum and constructed the microflare distribution shown in the figure. The results of the automated search start to deviate from the manual search results below about 1000 s (exp -1). Not only do we now have this distribution but we have a database of solar microflares that was used to construct the distribution. This database contains the signal at higher energy channels as well as that in channel zero (and below). From this one can, using software at GSFC, construct a photon spectrum for some of the larger microflares. It can also be used in other solar studies, especially those that correlate the X-ray flux with emission at other wavelengths. With some additional effort we hope to integrate this database into the corresponding one residing at the Solar Data Analysis Center at GSFC. The entire CGRO mission's data can now be reprocessed to obtain the microflare distribution at all phases of the solar cycle. This work is in progress. The results of this work will be presented in forthcoming scientific workshops and conferences.

Ryan, James M.↗

Micromechanical and fatigue in situ synchrotron characterization of an additively manufactured superalloy with porosity

Additive manufacturing (AM) has the potential to transform component production, but its widespread adoption is constrained by defects, such as pores, that compromise structural integrity. Here, this study investigates the influence of porosity on the micromechanical and fatigue response of AM Inconel 718 (IN718), a widely used aerospace superalloy. One baseline specimen with minimal stochastic porosity and another intentionally seeded with lack of fusion (LOF) pores were examined using high-energy X-ray diffraction microscopy (HEDM) and micro-computed tomography during cyclic loading. Fatigue cracks in the LOF specimen initiated more frequently and at lower cycle counts than in the baseline specimen. The number fraction of fatigue cracks that grew was comparatively higher in the LOF specimen. Grain-level metrics, including stress and diffraction spot widths, were quantified using far-field HEDM. Across the thousands of grains detected in both specimens, the pores in the LOF specimen increased the variability of stress and spot width evolution in the azimuthal direction, the latter serving as a surrogate measure of plastic deformation. However, no correlations emerged between these metrics and grain proximity to fatigue crack initiation sites or pores, underscoring the limitations of grain-averaged metrics for predicting fatigue. Nonetheless, the rich dataset reported here provides a foundation for future modeling efforts.

High-energy X-ray diffraction microscopy↗

Density scaling approximation for Monte-Carlo simulations of radioactive plumes

The release of radioactive gas into the atmosphere can diffuse into large volumes of air downwind from the point of release. The extent of radioactivity can cover thousands of cubic meters of air. For such large volumes, the weather models used to predict the down-wind distribution of the plume and the radiation transport models used to predict the radiation reaching ground-level from the plume can take tens of hours of computer time on multi-node institutional High-Performance Computing facilities. In this paper we focus on the radiation transport aspect of plume modeling. Here, we describe a phenomenological method for approximating the amounts of radiation that reach ground level from large volumes of a static radioactive plume that can be calculated on a stand-alone personal computer in much shorter computation times than those usually needed for such large volume evaluations. We refer to this method as the Density Scaling Approximation (DSA). Its ability to approximate ground-level count rates of large plumes comes from using a small-plume volume with a scaled-up value of air density to simulate the same number of scatterings that occur during transport in larger plume volumes at normal air density. We demonstrate the DSA by using a 100 m-diameter air-filled hemispherical dome geometry with a uniform volumetric activity of 135 Xe gas throughout the air-filled volume. The DSA for a larger dome diameter is obtained by evaluating the 100 m dome with an air density scaled up by the linear ratio of the larger diameter to the 100 m diameter. We find that this approximation works well for dome diameters up to 1200 m – the largest diameter studied and a size more than sufficient for accounting for all the radiation from 135 Xe. Moreover, most of our DSA results can be calculated over 500 times faster than corresponding full-sized geometry with normal air density. To help evaluate the accuracy of the DSA and gain insight into how well it can reproduce different regions of the spectra, we use three, easily understood regions of interest to compare the DSA results to the full-sized geometry at normal air density results. These regions are the full-energy peak, the region of single-Compton scattering, and the region of multiple-Compton scattering. We show how the dominance of the Compton scattering mechanism determines this division and thus provides insight into how Compton scattering is manifested in spectra from photon scattering through air in general, and how well the DSA approximation works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for hard X-ray directivity during the rise, peak, and decay phases of solar flares

We have identified 72 large solar flares (peak counting rates more than 1000 counts/s) observed by Hard X-ray Burst Spectroscopy (HXRBS) on-board the Solar Maximum Mission (SMM). Using a database of these flares, we have studied hard X-ray (50-850 keV) spectral center-to-limb variation and its evolution with time. The major results are the following: (1) During the rise phase, the center-to-limb spectral variation is small, with a hardness of delta delta = 0.02 +/- 0.25, and a statistical significance of 0.1 sigma. (2) During the peak phase, the center-to-limb variation is delta delta = 0.13 +/- 0.13, with a statistical significance of 1 sigma. (3) During the decay phase, the center-to-limb variation changes to softening. The softness is relatively large with delta delta = -0.25 +/- 0.21, and a statistical significance of 1.2 sigma. (4) The linear least-squares fits to the spectral center-to-limb variations do not have slopes significantly different from zero during all those three phases. (5) The center events and limb events spectral distributions are shown to be not different by using Kolmogorov-Smirnov two-samples test. (6) The fraction of events detected near the limb is marginally consistent with that expected from isotropically emitting flares. (7) On average, flares evolve as soft-hard-soft. These results suggest that there is no statistically significant evidence for hard X-ray directivity during the rise, peak, and decay phases of solar flares. The hard X-ray radiation pattern at those energies is almost isotropic during all those phases. This lack of directivity (or anisotropy) found in this study is not in agreement with the results discovered by Vestrand et al. (1987) in which they found energetic photon source is anisotropic, using SMM Gamma-Ray Spectrometer (GRS) data at a much higher energy band of 0.3-1 MeV. If we want to interpret the results of Vestrand et al. (1987) and our present results in a self-consistent way, we must conclude that at energies of greater than 50 keV, the Compton backscattering suppresses the hard X-ray anisotropy sufficiently so that no significant directivity can be measured during the rise, peak, and decay phases of solar flares. during the rise, peak, and decay phases of solar flares.

Li, Peng↗

The miniJPAS survey: A search for extreme emission-line galaxies

Context. Galaxies with extreme emission lines (EELGs) may play a key role in the evolution of the Universe, as well as in our understanding of the star formation process itself. For this reason an accurate determination of their spatial density and fundamental properties in different epochs of the Universe will constitute a unique perspective towards a comprehensive picture of the interplay between star formation and mass assembly in galaxies. In addition to this, EELGs are also interesting in order to explain the reionization of the Universe, since their interstellar medium (ISM) could be leaking ionizing photons, and thus they could be low z, analogous of extreme galaxies at high z . Aims. This paper presents a method to obtain a census of EELGs over a large area of the sky by detecting galaxies with rest-frame equivalent widths ≥300 Å in the emission lines [O II]λλ3727,3729Å, [O III]λ5007Å, and Hα. For this, we aim to use the J-PAS survey, which will image an area of ≈8000 deg 2 with 56 narrow band filters in the optical. As a pilot study, we present a methodology designed to select EELGs on the miniJPAS images, which use the same filter dataset as J-PAS, and thus will be exportable to this larger survey. Methods. We make use of the miniJPAS survey data, conceived as a proof of concept of J-PAS, and covering an area of ≈1 deg 2 . Objects were detected in the r SDSS images and selected by imposing a condition on the flux in a given narrow-band J-PAS filter with respect to the contiguous ones, which is analogous to requiring an observed equivalent width larger than 300 Å in a certain emission line within the filter bandwidth. The selected sources were then classified as galaxies or quasi-stellar objects (QSOs) after a comparison of their miniJPAS fluxes with those of a spectral database of objects known to present strong emission lines. This comparison also provided a redshift for each source, which turned out to be consistent with the spectroscopic redshifts when available (|Δz/(1 + z spec )| ≤ 0.01). Results. The selected candidates were found to show a compact appearance in the optical images, some of them even being classified as point-like sources according to their stellarity index. After discarding sources classified as QSOs, a total of 17 sources turned out to exhibit EW 0 ≥ 300 Å in at least one emission line, thus constituting our final list of EELGs. Our counts are fairly consistent with those of other samples of EELGs in the literature, although there are some differences, which were expected due to biases resulting from different selection criteria.

59 BASIC BIOLOGICAL SCIENCES↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Coating MCPs with AlN and GaN

A development effort underway at the time of reporting the information for this article is devoted to increasing the sensitivity of microchannel plates (MCPs) as detectors of photons and ions by coating the MCPs with nitrides of elements in period III of the periodic table. Conventional MCPs are relatively insensitive to slowly moving, large-mass ions for example, ions of biomolecules under analysis in mass spectrometers. The idea underlying this development is to coat an MCP to reduce its work function (decrease its electron affinity) in order to increase both (1) the emission of electrons in response to impingement of low-energy, large-mass ions and (2) the multiplying effect of secondary electron emission. Of particular interest as coating materials having appropriately low or even negative electron affinities are gallium nitride, aluminum nitride, and ternary alloys of general composition Al(x)Ga(1-x)N (where 0<x<1). These materials exhibit attractively high degrees of chemical, mechanical, and thermal stability plus acceptably high resistance to sputtering. The electron-excitation cross sections of these materials are expected to exceed those of several other materials (including diamond) that are, variously, in use or under development for the same purpose. Moreover, by doping these materials with silicon, one can render them partly electrically conductive, thereby suppressing the undesired accumulation of electric charge that could otherwise occur during bombardment by ions. For experiments, thin films of AlN and GaN both undoped and doped with Si were deposited on commercial MCPs by radio-frequency molecular-beam epitaxy (also known as plasma-assisted molecular-beam epitaxy) at temperatures <200 C. This deposition technique is particularly suitable because (1) MCPs cannot withstand the higher deposition-substrate temperatures used to decompose constituent compounds in some other deposition techniques and (2) in this technique, the constituent Al, Ga, and N are supplied in elemental form, so that there is no need for thermal decomposition at the substrate surface. The nitride films thus formed were, variously, amorphous or polycrystalline. The nitride films were coated with surface layers of gold <100 thick. The MCPs were tested in a standard configuration in which the output stage of a first MCP was coupled to the input stage of a second MCP. Each pair of MCPs was mounted in a standard holder that included front and back contact rings and an anode for collecting the output electrons of the second MCP. The MCP pairs were biased at potentials between 1.7 and 1.9 kV, and count rates measured after preamplification and discrimination. To enable a direct comparison, in one pair, the second MCP was uncoated while the first MCP was coated over half its surface. The coated and uncoated sides of the half-coated MCP were exposed to fluxes of argon ions at kinetic energies of 1.0 and 0.5 keV. At 1.0 keV, the count rate for the coated side was about 2.3 times greater than that for the uncoated side; at 0.5 keV, the count rate for the coated side was about 1.8 times greater than that for the uncoated side.

Bensaoula, Abdelhakim↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Acute effects of whole-body proton irradiation on the immune system of the mouse

The acute effects of proton whole-body irradiation on the distribution and function of leukocyte populations in the spleen and blood were examined and compared to the effects of photons derived from a (60)Co gamma-ray source. Adult female C57BL/6 mice were exposed to a single dose (3 Gy at 0.4 Gy/min) of protons at spread-out Bragg peak (SOBP), protons at the distal entry (E) region, or gamma rays and killed humanely at six different times thereafter. Specific differences were noted in the results, thereby suggesting that the kinetics of the response may be variable. However, the lack of significant differences in most assays at most times suggests that the RBE for both entry and peak regions of the Bragg curve was essentially 1.0 under the conditions of this study. The greatest immunodepression was observed at 4 days postexposure. Flow cytometry and mitogenic stimulation analyses of the spleen and peripheral blood demonstrated that lymphocyte populations differ in radiosensitivity, with B (CD19(+)) cells being most sensitive, T (CD3(+)) cells being moderately sensitive, and natural killer (NK1.1(+)) cells being most resistant. B lymphocytes showed the most rapid recovery. Comparison of the T-lymphocyte subsets showed that CD4(+) T helper/inducer cells were more radiosensitive than the CD8(+) T cytotoxic/suppressor cells. These findings should have an impact on future studies designed to maximize protection of normal tissue during and after proton-radiation exposure.

NASA Discipline Radiation Health↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗