Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

A compact apparatus for studies of element and phase-resolved ferromagnetic resonance

We present a compact sample holder equipped with electromagnets and high frequency transmission lines; the sample holder is intended for combined x-ray magnetic circular dichroism (XMCD) and ferromagnetic resonance measurements (FMR). Time-resolved measurements of resonant x-ray detected FMR during forced precession are enabled by use of a rf excitation that is phase-locked to the storage ring bunch clock. Several applications of the combined XMCD+FMR technique are presented, demonstrating the flexibility of the experimental design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Knot undulator to generate linearly polarized photons with low on-axis power density

Heat load on beamline optics is a serious obstacle for devices designed to generate pure linearly polarized photons in third generation synchrotron radiation facilities. For permanent magnet undulators, this problem can be overcome by implementing a figure-eight design configuration. As yet there has been no good method to tackle this problem for electromagnetic elliptical undulators. Here, a novel design and operational mode is suggested, which can generate pure linearly polarized photons with very low on-axis heat load. Additionally, the minimum photon energy capability of linearly polarized photons can be significantly extended by this method.

43 PARTICLE ACCELERATORS↗

Calorimetric low temperature detectors for low-energetic heavy ions and their application in accelerator mass spectrometry

The energy-sensitive detection of heavy ions with calorimetric low temperature detectors was investigated in the energy range of E=0.1-1 MeV/amu, commonly used for accelerator mass spectrometry (AMS). The detectors used consist of sapphire absorbers and superconducting aluminum transition edge thermometers operated at T{approx}1.5 K. They were irradiated with various ion beams ({sup 13}C,{sup 197}Au,{sup 238}U) provided by the VERA tandem accelerator in Vienna, Austria. The relative energy resolution obtained was {Delta}E/E=(5-9)x10{sup -3}, even for the heaviest ions such as {sup 238}U. In addition, no evidence for a pulse height defect was observed. This performance allowed for the first time to apply a calorimetric low temperature detector in an AMS experiment. The aim was to precisely determine the isotope ratio of {sup 236}U/{sup 238}U for several samples of natural uranium, {sup 236}U being known as a sensitive monitor for neutron fluxes. Replacing a conventionally used detection system at VERA by the calorimetric detector enabled to substantially reduce background from neighboring isotopes and to increase the detection efficiency. Due to the high sensitivity achieved, a value of {sup 236}U/{sup 238}U=6.1x10{sup -12} could be obtained, representing the smallest {sup 236}U/{sup 238}U ratio measured at the time. In addition, we contributed to establishing an improved material standard of {sup 236}U/{sup 238}U, which can be used as a reference for future AMS measurements.

43 PARTICLE ACCELERATORS↗

Vacuum-compatible pulse selector for free-electron laser

We developed a vacuum-compatible pulse selector for a free-electron laser. A rotating cylinder with eight apertures in a vacuum is driven by a closed-loop stepping motor system through a magnetically coupled rotary feedthrough. A field programmable gate array is used to synchronize the cylinder rotation with a trigger signal of the accelerator at a maximum repetition rate of 60 Hz. We achieved to select specific pulses from a continuous pulse train of the SPring-8 Compact SASE Source.

43 PARTICLE ACCELERATORS↗

Calculations of synchrotron radiation emission in the transverse coherent limit

We present approximations for the synchrotron radiation emission for low emittance light sources, which provide a connection between user needs and the electron beam parameters. The results and calculations are a consequence of the phase coherence in the emission from the electrons. We derive the remarkable result that if the electron beam is energetic enough, the emitted flux is independent of the photon energy, electron beam energy, or bending radius in the transverse coherent limit. Similarly the brightness is identical for all machines at a given current.

43 PARTICLE ACCELERATORS↗

Repetitive production of positron emitters using deuterons accelerated by multiterawatt laser pulses

Positron emitters {sup 11}C, {sup 13}N, and {sup 15}O, which can be used in positron emission tomography, were produced using deuterons accelerated by irradiation of laser pulses {approx}70 TW in peak power and {approx}30 fs in duration with a repetition of 10 Hz during a period of as long as 200 s. Every laser pulse irradiates the fresh surface of a long strip of a solid-state thin film. Deuterons contained in the film are accelerated in the relativistic plasma induced by the pulse. The deuterons are repetitively incident on solid plates, which are placed near the film, to produce positron emitters by nuclear reactions. The radioactivities of the activated plates are measured after the termination of laser irradiation. In activation of graphite, boron-nitride, and melamine plates, the products had total activities of 64, 46, and 153 Bq, respectively. Contamination in the setup was negligible even after several thousands of laser shots. Our apparatus is expected to greatly contribute to the construction of a compact PET diagnostic system in the future.

43 PARTICLE ACCELERATORS↗

Generation of multicomponent ion beams by a vacuum arc ion source with compound cathode

This paper presents the results of time-of-flight mass spectrometry studies of the elemental and mass-to-charge state compositions of metal ion beams produced by a vacuum arc ion source with compound cathode (WC-Co{sub 0.5}, Cu-Cr{sub 0.25}, Ti-Cu{sub 0.1}). We found that the ion beam composition agrees well with the stoichiometric composition of the cathode material from which the beam is derived, and the maximum ion charge state of the different plasma components is determined by the ionization capability of electrons within the cathode spot plasma, which is common to all components. The beam mass-to-charge state spectrum from a compound cathode features a greater fraction of multiply charged ions for those materials with lower electron temperature in the vacuum arc cathode spot, and a smaller fraction for those with higher electron temperature within the spot. We propose a potential diagram method for determination of attainable ion charge states for all components of the compound cathodes.

43 PARTICLE ACCELERATORS↗

General design of the International Fusion Materials Irradiation Facility deuteron injector: Source and beam line

In the framework of the International Fusion Materials Irradiation Facility-Engineering Validation and Engineering Design Activities (IFMIF-EVEDA) project, CEA/IRFU is in charge of the design and realization of the 140 mA cw deuteron Injector. The electron cyclotron resonance ion source operates at 2.45 GHz and a 4 electrode extraction system has been chosen. A 2 solenoid beam line, together with a high space charge compensation have been optimized for a proper beam injection in the 175 MHz radio frequency quadrupole. The injector will be tested with proton and deuteron beam production either in pulsed mode or in cw mode on the CEA-Saclay site before to be shipped to Japan. Special attention was paid to neutron emission due to (d,D) reaction. In this paper, the general IFMIF Injector design is reported, pointing out beam dynamics, radioprotection, diagnostics, and mechanical aspects.

43 PARTICLE ACCELERATORS↗

Application of a simple asynchronous mechanical light chopper to multielectron coincidence spectroscopy

A simple asynchronous mechanical light chopper, based on modification of a turbo-molecular pump, has been developed to extend the interval between light pulses in single bunch operation at the Photon Factory storage ring. A pulse repetition rate of 80 kHz was achieved using a cylinder rotating at 48000 rpm, with 100 slits of 80 {mu}m width. This allows absolute timing of particles up to 12.48 {mu}s instead of the single-bunch period of 624 ns. We have applied the chopper together with a light pulse monitor to measure multielectron coincidence spectra using a magnetic bottle time-of-flight electron spectrometer. With such a system, the electron energies are determined without any ambiguity, the folding of coincidence spectra disappears and the effect of false coincidences is drastically reduced.

43 PARTICLE ACCELERATORS↗

The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS

Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount of bremsstrahlung radiation is significantly decreased.

43 PARTICLE ACCELERATORS↗

Simulation of parameter scaling in electron cyclotron resonance ion source plasmas using the GEM code

Although heating power and gas pressure are two of the two of primary experimental ''knobs'' available to users of electron cyclotron resonance ion sources, there is still no clear understanding of how they interact in order to provide optimal plasma conditions. FAR-TECH, Inc. has performed a series of simulations with its generalized electron cyclotron resonance ion source model in which the power and pressure were varied over a wide range. Analysis of the numerical data produces scaling laws that predict the plasma parameters as a function of the power and pressure. These scaling laws are in general agreement with experimental data.

43 PARTICLE ACCELERATORS↗

Windowless microfluidic platform based on capillary burst valves for high intensity x-ray measurements

We propose and describe a microfluidic system for high intensity x-ray measurements. The required open access to a microfluidic channel is provided by an out-of-plane capillary burst valve (CBV). The functionality of the out-of-plane CBV is characterized with respect to the diameter of the windowless access hole, ranging from 10 to 130 {mu}m. Maximum driving pressures from 22 to 280 mbar corresponding to refresh rates of the exposed sample from 300 Hz to 54 kHz is demonstrated. The microfluidic system is tested at beamline ID09b at the ESRF synchrotron radiation facility in Grenoble, and x-ray scattering measurements are shown to be feasible and to require only very limited amounts of sample, <1 ml/h of measurements without recapturing of sample. With small adjustments of the present chip design, scattering angles up to 30 deg. can be achieved without shadowing effects and integration on-chip mixing and spectroscopy appears straightforward.

43 PARTICLE ACCELERATORS↗

Demonstration of a highly coherent 13.9 nm x-ray laser from a silver tape target

A highly coherent 13.9 nm x-ray laser (XRL) is generated under an oscillator-amplifier configuration using a new tape target system and a driver laser system with a 0.1 Hz repetition rate. The output energy is comparable to the XRL generated with a silver-deposited slab target, and the pointing stability using the new tape target system is better than conventional slab targets.

43 PARTICLE ACCELERATORS↗

A short pulse (7 {mu}s FWHM) and high repetition rate (dc-5kHz) cantilever piezovalve for pulsed atomic and molecular beams

In this paper we report on the design and operation of a novel piezovalve for the production of short pulsed atomic or molecular beams. The high speed valve operates on the principle of a cantilever piezo. The only moving part, besides the cantilever piezo itself, is a very small O-ring that forms the vacuum seal. The valve can operate continuous (dc) and in pulsed mode with the same drive electronics. Pulsed operation has been tested at repetition frequencies up to 5 kHz. The static deflection of the cantilever, as mounted in the valve body, was measured as a function of driving field strength with a confocal microscope. The deflection and high speed dynamical response of the cantilever can be easily changed and optimized for a particular nozzle diameter or repetition rate by a simple adjustment of the free cantilever length. Pulsed molecular beams with a full width at half maximum pulse width as low as 7 {mu}s have been measured at a position 10 cm downstream of the nozzle exit. This represents a gas pulse with a length of only 10 mm making it well matched to for instance experiments using laser beams. Such a short pulse with 6 bar backing pressure behind a 150 {mu}m nozzle releases about 10{sup 16} particles/pulse and the beam brightness was estimated to be 4x10{sup 22} particles/(s str). The short pulses of the cantilever piezovalve result in a much reduced gas load in the vacuum system. We demonstrate operation of the pulsed valve with skimmer in a single vacuum chamber pumped by a 520 l/s turbomolecular pump maintaining a pressure of 5x10{sup -6} Torr, which is an excellent vacuum to have the strong and cold skimmed molecular beam interact with laser beams only 10 cm downstream of the nozzle to do velocity map slice imaging with a microchannel-plate imaging detector in a single chamber. The piezovalve produces cold and narrow ({Delta}v/v=2%-3%) velocity distributions of molecules seeded in helium or neon at modest backing pressures of only 6 bar. The low gas load of the cantilever valve makes it possible to design very compact single chamber molecular beam machines with high quality cold and intense supersonic beams. The high speed cantilever piezovalve may find broad applicability in experiments where short and strong gas pulses are needed with only modest pumping, the effective use of (expensive) samples, or the production of cold atomic and molecular beams.

43 PARTICLE ACCELERATORS↗

Recent operation status of Japan Proton Accelerator Research Complex H{sup -} ion source

A cesium-free H{sup -} ion source driven with a LaB{sub 6} filament is being operated at the Japan Proton Accelerator Research Complex for approximately three years without any serious trouble. In the beam commissioning or supply runs, the ion source has been operated in two different modes such as low current mode of 5 mA and high current mode of 30 mA. The total interruption time during the runs due to the ion source failure is approximately 50 h, which correspond to the ion source availability of 99%. After a long-term operation, the surface of the filament and the plasma electrode become discolored with dark partially. The result of surface analysis with field emission scanning electron microscope showed that most of the dark material is formed with boron. At the beam test performed in the interval of the run, we demonstrated that the H{sup -} current increased by miniaturizing the LaB{sub 6} filament.

43 PARTICLE ACCELERATORS↗

Recent results of the laser ion source facility at INFN-LNS and applications to nuclear and applied research

A pulsed neodymium-doped yttrium aluminum garnet laser ion source has been used as proton beams generator. The laser wavelength is 1064 nm, the pulse duration is 9 ns and the intensity reaches 10{sup 10} W/cm{sup 2}. Laser irradiates hydrogenated polymers targets located in a chamber at 10{sup -7} mbar. The ions are post-accelerated in a suitable chamber by 30 kV of voltage between the target, positively biased, and the following ground electrode. The extracted beams is characterized through a time-of-flight technique. Possible applications to the field of nuclear physics, such as nuclear excitation and de-excitations, nuclear reactions and nuclear fusion, will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Portable emittance measurement device

In Institute for Theoretical and Experimental Physics (ITEP) the portable emittance measurements device is developed. It provides emittance measurements both with ''pepper-pot'' and ''two slits'' methods. Depending on the method of measurements, either slits or pepper-pot mask with scintillator are mounted on the two activators and are installed in two standard Balzer's cross chamber with CF-100 flanges. To match the angle resolution for measured beam, the length of the stainless steel pipe between two crosses changes is adjusted. The description of the device and results of emittance measurements at the ITEP ion source test bench are presented.

43 PARTICLE ACCELERATORS↗

The third generation superconducting 28 GHz electron cyclotron resonance ion source VENUS (invited)

VENUS is a third generation electron cyclotron resonance (ECR) ion source, which incorporates a high field superconducting NbTi magnet structure, a 28 GHz gryotron microwave source and a state of the art closed cycle cryosystem. During the decade from initial concept to regular operation, it has demonstrated both the feasibility and the performance levels of this new generation of ECR ion sources and required innovation on magnet construction, plasma chamber design, and beam transport. In this paper, the development, performance, and major innovations are described as well as a look to the potential to construct a fourth generation ECR ion source.

43 PARTICLE ACCELERATORS↗