Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Technology Solutions for New Homes Case Study: Indirect Solar Water Heating Systems in Single-Family Homes

In 2011, Rural Development, Inc. (RDI) completed the construction of Wisdom Way Solar Village (WWSV), which is a development of 20 very efficient homes in Greenfield, Massachusetts. The homes feature R-40 walls, triple-pane windows, R-50 attic insulation, and airtight construction. All homes also have photovoltaic (PV) systems and solar domestic hot water (SDHW) systems. Auxiliary water heating is provided by tankless gas water heaters. With the SDHW systems, RDI hoped to eliminate most of the need for gas for water heating and get the homes closer to zero energy.

building america↗

Predicting Future Soiling Losses Using Environmental Data: Preprint

Soiling consists of the accumulation of dust and dirt on the surfaces of photovoltaic (PV) modules and causes a reduction in the energy conversion. Investors generally consider an average yearly soiling loss to estimate the energy yield and the economic revenue of a site for a new PV installation. If soiling could be estimated from wide available parameters, describing the pollution and the rainfall pattern at a site, more accurate losses could be predicted, reducing the uncertainty in the estimation of the energy yield and therefore the finance rates offered for new PV systems. The present work investigates the correlations between present environmental parameters and future soiling losses.

14 SOLAR ENERGY↗

Addressing the split incentive challenge for rooftop solar PV and battery energy storage in multifamily rental buildings (CRADA 638 Final Report)

This project advances the understanding of how roof solar PV systems and battery energy storage systems (BESS) can be effectively deployed in multifamily residential buildings, a sector that has historically faced barriers due to misaligned incentives between landlords and tenants. By leveraging high-resolution building stock data and simulation tools, the research demonstrates how energy consumption patterns vary across building types, climates, and occupant characteristics, and how these variations influence the optimal sizing and operation of distributed energy resources. A key contribution is the development of a publicly accessible, web-based tool named RESIDE (Residential Energy Systems & Infrastructure Data Evaluation) that allows users to explore building energy use and evaluate solar and battery configurations without requiring specialized expertise. This significantly lowers the barrier to entry for stakeholders such as property owners, utilities, and policymakers. From a technical perspective, the project shows that integrating rooftop solar PV with battery energy storage can substantially reduce electricity costs and peak demand through strategies such as energy arbitrage and peak shaving. The modeling framework incorporates real-world constraints, including time-of-use electricity pricing and battery degradation, providing realistic and actionable insights. Economically, the results indicate that properly sized systems can deliver meaningful cost savings, improving the feasibility of energy investments in multifamily housing. More broadly, the project benefits the public by supporting the transition to affordable and reliable energy, particularly in rental multifamily housing where adoption has traditionally lagged.

14 SOLAR ENERGY↗

New Approaches to Distributed PV Interconnection: Implementation Considerations for Addressing Emerging Issues

As the cost of installing distributed solar photovoltaics (PV) has fallen, the number of requests to interconnect PV systems to distribution grids has risen substantially in many utility service areas. In response, states and utilities are modifying their interconnection practices to address new DER challenges. This report examines emerging issues associated with interconnecting residential- and commercial-scale PV to facilitate sharing of lessons learned and best practices across jurisdictions. It covers issues related to allocating and understanding costs, understanding grid conditions to inform PV siting, interconnecting storage, automating processes, and requiring the availability of advanced inverter functions that can help increase PV hosting capacity. This report builds on an earlier study that reviews interconnection practices and costs across the western states (Bird et al. 2018). Both reports were developed as part of a larger, joint project between the Western Interstate Energy Board and the National Renewable Energy Laboratory, funded by the U.S. Department of Energy's Solar Energy Technologies Office, that examines barriers to distributed PV in the 11 states within the Western Interconnection.

14 SOLAR ENERGY↗

Review of Standby and Ancillary Services in the Context of Behind-the-Meter Photovoltaics

The New Mexico Public Regulatory Commission (NMPRC) requested information on the following topics: Overview of ancillary and standby services. Examples of how ancillary and standby services are defined, used, and analyzed in other jurisdictions. Considerations regarding how ancillary and standby services may be economically valued. Background information on how ancillary and standby services differ from fixed costs to serve owners of behind-the-meter solar photovoltaic (BTM PV) systems.

14 SOLAR ENERGY↗

Space Environment Testing of Photovoltaic Array Systems at NASA's Marshall Space Flight Center

To successfully operate a photovoltaic (PV) array system in space requires planning and testing to account for the effects of the space environment. It is critical to understand space environment interactions not only on the PV components, but also the array substrate materials, wiring harnesses, connectors, and protection circuitry (e.g. blocking diodes). Key elements of the space environment which must be accounted for in a PV system design include: Solar Photon Radiation, Charged Particle Radiation, Plasma, and Thermal Cycling. While solar photon radiation is central to generating power in PV systems, the complete spectrum includes short wavelength ultraviolet components, which photo-ionize materials, as well as long wavelength infrared which heat materials. High energy electron radiation has been demonstrated to significantly reduce the output power of III-V type PV cells; and proton radiation damages material surfaces - often impacting coverglasses and antireflective coatings. Plasma environments influence electrostatic charging of PV array materials, and must be understood to ensure that long duration arcs do not form and potentially destroy PV cells. Thermal cycling impacts all components on a PV array by inducing stresses due to thermal expansion and contraction. Given such demanding environments, and the complexity of structures and materials that form a PV array system, mission success can only be ensured through realistic testing in the laboratory. NASA's Marshall Space Flight Center has developed a broad space environment test capability to allow PV array designers and manufacturers to verify their system's integrity and avoid costly on-orbit failures. The Marshall Space Flight Center test capabilities are available to government, commercial, and university customers. Test solutions are tailored to meet the customer's needs, and can include performance assessments, such as flash testing in the case of PV cells.

Phillips, Brandon S.↗

Houston, We Have a Problem-and a Solution: Solar Performance Initiative Helps Federal Building Boost Rooftop Production

In 2014, the Mickey Leland Federal Building in Houston, Texas installed a 192 kW PV system on top of its parking structure. To monitor and optimize its performance, the General Services Administration, which manages the site, responded to the Federal Energy Management Program’s request for federal agency participation in the Federal Energy Management Program Solar PV Performance Initiative.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Achieving a 100% Renewable Grid: Operating Electric Power Systems with Extremely High Levels of Variable Renewable Energy

What does it mean to achieve a 100% renewable grid? Several countries already meet or come close to achieving this goal. Iceland, for example, supplies 100% of its electricity needs with either geothermal or hydropower. Other countries that have electric grids with high fractions of renewables based on hydropower include Norway (97%), Costa Rica (93%), Brazil (76%), and Canada (62%). Hydropower plants have been used for decades to create a relatively inexpensive, renewable form of energy, but these systems are limited by natural rainfall and geographic topology. Around the world, most good sites for large hydropower resources have already been developed. So how do other areas achieve 100% renewable grids? Variable renewable energy (VRE), such as wind and solar photovoltaic (PV) systems, will be a major contributor, and with the reduction in costs for these technologies during the last five years, large-scale deployments are happening around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Ready: Strategies for Interconnecting Large-Scale PV in New York City

This Grid Ready Solar project is intended to help create transparency for building owners and developers, so they can better understand and more quickly navigate the interconnection process for large-scale photovoltaic (PV) projects on Con Edison's electrical grid in New York City. Phase 1 of the project provided high-level technical screens of grid interconnection requirements in an attempt to streamline the interconnection of large-scale solar PV systems to the New York City grid. In Phase 2 of the Grid Ready project, the focus of this report, Sustainable CUNY worked with NREL to evaluate a range of solutions for improving the economics of large-scale (over 200 kW) PV within the five boroughs of New York City that are in Con Edison's service territory, as identified on the NY Solar Map.

14 SOLAR ENERGY↗

Weather impacts on solar PV operations summary of the current body of knowledge and implications for further investigation

There is growing concern that severe weather events are negatively affecting solar photovoltaic (PV) systems and pose ongoing and unrecognized risks. Clearly research is needed to quantify and characterize the risks so that properly calibrated improvements can be implemented. To begin this process, this report is a collection of information of severe weather impacts on solar PV available today taken from research, insurance data, and field inspections. While it is not comprehensive enough to draw conclusions, this information provides a baseline for action and indicates an urgent need to investigate further.

14 SOLAR ENERGY↗

Muckleshoot Indian Tribe-Energy Deployment (MITED) Project

The Muckleshoot Indian Tribe (MIT) collaborated with our Project Partner, GRID Alternatives (GRID), to install 132 kilowatts of direct current (kW-DC) of rooftop solar on three Tribal facilities. The three facilities are the Tribe’s Youth Drop-In Center, Canoe Shed, and Water Treatment Facility. The solar PV systems were originally anticipated to offset approximately 45% of the aggregate annual electricity usage of the three buildings. A major aspect of the MIT-ED project was providing hands-on paid training to five Muckleshoot Building Maintenance workers in solar PV installations, operations, and maintenance. The scope of work aligns with the Tribe’s goals of building local capacity and providing real world work experience and potential career opportunities in solar PV to its citizens. The Building Maintenance Department committed five of its current FTE employees to the project. GRID provided guidance for the MIT project team on identifying paid trainees as well as end goals of skill development through training, including a long-term Operations and Maintenance (O&M) plan tailored to the Tribe’s goals of local capacity building and stewardship of natural resources.

14 SOLAR ENERGY↗

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Impact of Wide-Scale Implementation of Net Zero-Energy Homes on the Western Grid

Pacific Northwest National Laboratory conducted a study on the impact of wide-scale implementation of net zero-energy homes (ZEHs) in the western grid. Although minimized via utilization of advanced building technologies, ZEHs still consume energy that must be balanced on an annual basis via self-generation of electricity which is commonly assumed to be from rooftop photovoltaics (PV). This results in a ZEH having a significantly different electricity demand profile than a conventional home. Wide-spread implementation of ZEHs will cause absolute demand levels to fall compared to continued use of more conventional facilities; however, the shape of the demand profile will also change significantly. Demand profile changes will lead to changes in the hourly value of electric generation. With significant penetration of ZEHs, it can be expected that ZEHs will face time of day rates or real time pricing that reflect the value of generation and use. This will impact the economics of ZEHs and the optimal design of PV systems for subsequent ZEHs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Terms, Trends, and Insights: PV Project Finance in the United States, 2017

This brief is a compilation of data points and market insights that reflect the state of the project finance market for solar photovoltaic (PV) assets in the United States as of the third quarter of 2017. This information can generally be used as a simplified benchmark of the costs associated with securing financing for solar PV as well as the cost of the financing itself (i.e., the cost of capital). This work represents the second DOE sponsored effort to benchmark financing costs across the residential, commercial, and utility-scale PV markets, as part of its larger effort to benchmark the components of PV system costs.

14 SOLAR ENERGY↗

A Practical Irradiance Model for Bifacial PV Modules: Preprint

A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors (CFs) to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using the RADIANCE ray tracing program.

14 SOLAR ENERGY↗