Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLLUTANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

3D graphene aerogels-supported Ag and Ag@Ag3PO4 heterostructure for the efficient adsorption-photocatalysis capture of different dye pollutants in water

Highlights: • 3D graphene aerogels-supported Ag and Ag@Ag3PO4 heterostructure are synthesized. • The composite is effective in adsorption-photocatalysis cationic and anionic dyes. • The apparent adsorption-photocatalysis removal sequence is NR > RhB > MB > MO. • The contributions of adsorption and photocatalysis is different for different dyes. • The composite exhibits the highest catalytic activities with excellent stability. - Abstract: In this paper, we successfully synthesized 3D graphene aerogels-supported Ag and Ag@Ag{sub 3}PO{sub 4} heterostructure (3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA) by the hetero-growth of Ag{sub 3}PO{sub 4} on partly Ag nanoparticles in macroporous 3D graphene aerogels (3D GA), aiming for the efficient adsorption-photocatalysis capture of both cationic (RhB, MB, and NR) and anionic (MO) dyes from aqueous solutions. For the removal of different dyes, the contributions of adsorption and photocatalysis is different and the apparent removal sequence is NR > RhB > MB > MO on the prepared 3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA. Compared with bare Ag{sub 3}PO{sub 4} particles, Ag{sub 3}PO{sub 4}/GO, and Ag/Ag@Ag{sub 3}PO{sub 4}/GO, the prepared 3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA exhibits the highest catalytic activities for the visible light degradation of RhB and MO. The possible mechanism for improved photocatalytic degradation of dyes by the 3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA is proposed based on the active species trapping experiments. Moreover, the good stability and convenient recycling of the prepared 3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA composite further make it have potential application prospect in eliminating organic contaminants.

36 MATERIALS SCIENCE↗

The Moss Techniques for Air Pollution Study in Bulgaria

The paper presents new results on atmospheric deposition of 41 elements in four areas of Bulgaria during the European moss survey in 2005. The results have been obtained by the moss biomonitoring technique. Ninety seven moss samples were analyzed by instrumental neutron activation analysis (ENAA) and atomic absorption spectrometry (AAS).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ecological risk assessment of elemental pollution in sediment from Tunku Abdul Rahman National Park, Sabah

Eleven (11) surface sediment samples were collected from Tunku Abdul Rahman National Park, Sabah. The neutron activation analysis (NAA) and inductively coupled plasma-mass spectrometry (ICP-MS) techniques were applied for the determinations metal contents and their distributions in sediment samples. The results shown that Arsenic (As) concentrations are enriched at all sampling stations except for station TAR 09, with enrichment factor (EF) values ranged from 1.1 to 7.2. The elements such as Cd, Cr, Sb and U showed enrichment at a few stations and other elements (Cr, Cu, Pb, Th, Zn) shown as background levels in all stations. Degrees of contamination in this study were calculated base on concentrations of six elements (As, Cd, Cr, Cu, Pb, and Zn). TAR 11 station can be categorized as very high degree of contamination with degree of contamination value of 43.2. TAR 07 station can be categorized as a considerable degree of contamination (contamination value of 16.9). Six stations (TAR 01, 03, 04, 05, 06, 08, 10) showed moderate degree of contamination, with contamination values ranging from 8.0 to 16.0. TAR 02 and TAR 09 stations showed low degree of contaminations (< 8.0). TAR 11 showed very high ecological risk index (R{sub I}) with RI value is 916. TAR 07 and TAR 10 showed moderate ecological risk index with R{sub I} value 263 and 213, respectively. Other stations showed low ecological risk with RI values ranging from 42.3 to 117 (< 150). Very high ecological risk index could give an adverse effect to the benthic organism. The data obtained from the enrichment factor, degree of contamination and ecological risk index provided vital information, which can be used for future comparison. Information from the present study will be useful to the relevant government agencies and authorities in preparing preventive action to control direct discharge of heavy metals from industries, agro-base activities and domestic waste to the rivers and the sea.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Determination of heavy metal pollution in Zonguldak (Turkey) by moss analysis (hypnum cupressiforme)

This paper explores the first attempt at determining the levels of atmospheric heavy metal contamination in the Zonguldak province through the analysis of moss (Hypnum cupressiforme Hedw.). Sampling was performed at 24 sites after a wet period to avoid contamination from soil compounds in the province. Dried samples, which were unwashed but cleaned of soil particles and other extraneous material, were digested with HNO{sub 3}/HClO{sub 4}. Concentrations of heavy metals (Fe, Cu, Pb, Cr, Co, Ni, and As) were analyzed by ICP-OES to estimate the geographic distribution of the atmospheric heavy metal depositions. The general order of the concentrations of the heavy metal content in Hypnum cupressiforme Hedw. was observed to be Fe > Pb > Cu > Ni > Cr > As > Co. Mean levels of the measured elements were higher when compared to European levels. Arsenic, iron, and chromium were the most elevated elements when compared with European data. The mean concentrations of these elements in the studied area were 8.3 (Co), 6.7 (Fe), 5.2 (Cr), 4.6 (As), and 2.7 (Ni) times the background levels of the reference site (C3). Among the studied heavy metals, only lead showed little variation in measured values due to traffic in the area. Main sources of increased heavy metal content of the moss samples were found to be: I) the Catalagzi Power Plant (CATES); ii) the Eregli Iron-Steel Plant (ERDEMIR); iii) space heating; and iv) traffic-related emissions. Results are presented in the form of color-scaled contour maps using a Geographic Information System (GIS)-based mapping technique.

01 COAL, LIGNITE, AND PEAT↗

Analysis of organic pollutant degradation in pulsed plasma by coherent anti-Stokes Raman spectroscopy

The degradation of p-benzoquinone (p-BQ) in water was investigated by the coherent anti-Stokes Raman spectroscopy (CARS) method, in which the change of the anti-Stokes signal intensity corresponding to the vibrational transitions of the molecule is monitored during and after solution plasma processing (SPP). In the beginning of SPP treatment, the CARS signal intensity of the ring vibrational molecular transitions at 1233 and 1660 cm{sup -1} increases under the influence of the electric field of the plasma, depending on the delay time between the plasma pulse and the laser firing pulse. At the same time, the plasma contributes to the degradation of p-BQ molecules by generating hydrogen and hydroxyl radicals, which decompose p-BQ into different carboxylic acids. After SPP, the CARS signal intensity of the vibrational bands of p-BQ ceased and the degradation of p-BQ was confirmed by UV-visible absorption spectroscopy and liquid chromatography analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UNIQUE APPROACH TO COMPLYING WITH VERY LOW NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM PERMIT LIMITS FOR COPPER

The NPDES permit issued to the Savannah River Site (SRS) in 2003 contained copper limits as low as six micrograms per liter. It also contained compliance schedules that provided SRS with anywhere from three to five years to select and implement projects that would enable compliance at several outfalls. Some outfall problems were much more difficult to correct than others. SRS personnel implemented several innovative projects in order to meet compliance schedule deadlines as inexpensively as possible. One innovation, constructing a humic acid feed system to increase effluent dissolved organic carbon (DOC) content, has proven to be very successful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pollutant Removal Efficiency of Residential Cooking Exhaust Hoods

Capture efficiency (CE) of exhaust from a natural gas cooking range was quantified for three common designs of residential range hoods in laboratory experiments: (A) microwave exhaust combination; (B) short hood with grease-screen-covered air inlet at bottom; and (C) deep, open hood exhausting at top. Devices were evaluated at varying installation heights, at highest and lowest fan settings, and with the hood installed 15 cm away from back wall with intent to improve CE for front burners. Each configuration was evaluated for the oven and for three cooktop burner combinations (two back, two front, one front and one back). At highest fan settings and standard installation against the wall, Hoods A and C captured back cooktop burner exhaust at > 90 percent and Hood B at > 80 percent. In this configuration, CE for front burner exhaust was 73-78 percent for Hoods A and C but only 46-63 percent for Hood B. CEs followed similar patterns but were substantially lower on the lowest fan speed. Installing the hood away from the wall improved CE for oven and front burners on Hood A at low speed, but substantially reduced CE for back burners for all hoods at low and high speed.

03 NATURAL GAS↗

Economic implications of incorporating emission controls to mitigate air pollutants emitted from a modeled hydrocarbon-fuel biorefinery in the United States

The implementation of the US Renewable Fuel Standard is expected to increase the construction and operation of new biofuel facilities. Allowing this industry to grow without adversely affecting air quality is an important sustainability goal sought by multiple stakeholders. However, little is known about how the emission controls potentially required to comply with air quality regulations might impact biorefinery cost and deployment strategies such as siting and sizing. In this study, we use a baseline design for a lignocellulosic hydrocarbon biofuel production process to assess how the integration of emission controls impacts the minimum fuel selling price (MFSP) of the biofuel produced. We evaluate the change in MFSP for two cases as compared to the baseline design by incorporating (i) emission controls that ensure compliance with applicable federal air regulations and (ii) advanced control options that could be used to achieve potential best available control technology (BACT) emission limits. Our results indicate that compliance with federal air regulations can be achieved with minimal impact on biofuel cost (~$0.02 per gasoline gallon equivalent (GGE) higher than the baseline price of $5.10 GGE -1 ). However, if air emissions must be further reduced to meet potential BACT emission limits, the cost could increase nontrivially. For example, the MFSP could increase to $5.50 GGE -1 by adopting advanced emission controls to meet potential boiler BACT limits. Finally, given tradeoffs among emission control costs, permitting requirements, and economies of scale, these results could help inform decisions about biorefinery siting and sizing and mitigate risks associated with air permitting.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pollution and Risk of PAHs in Surface Sediments from the Tributaries and Their Relation to Anthropogenic Activities, in the Main Urban Districts of Chongqing City, Southwest China

Concentrations, sources and risk of 16 priority polycyclic aromatic hydrocarbons (PAHs) were investigated in surface sediments from 19 representative tributaries in a regional scale of Chongqing City. The total concentration of 16 PAHs (ΣPAHs) ranged from 221 to 3205 ng g{sup −1} with a mean of 1055 ng g{sup −1}. Most tributaries of the Jialing River exhibited significantly higher ΣPAHs concentrations (mean 1864 ng g{sup −1}) compared to those flowing into the Yangtze River (mean 787 ng g{sup −1}). Isomeric ratio and hierarchical clustering analysis showed combustion may impact sedimentary PAHs at most center sites of the City, while PAHs at most sites were mixed of petrogenic and pyrogenic sources. Toxicity equivalency concentration for carcinogenic PAH were 2–4 times more than the Dutch limit. More comprehensive assessment of safety is suggested to reduce environmental risk of PAHs in sediments.

54 ENVIRONMENTAL SCIENCES↗

Historical Pollution and Source Contributions of PAHs in Sediment Cores from the Middle Reach of Huai River, China

To investigate the spatial and historical distributions, and source contributions of polycyclic aromatic hydrocarbon (PAHs) from the middle reach of Huai River, 15 surface sediments and two sediment cores were analyzed. The Σ{sub 16} PAHs levels in surface sediments varied from 533.15 to 1422.83 ng/g dw, and from 413.27 to 43951.56 ng/g dw in individual sediment layer of sediment cores. The temporal trends of PAHs in sediment cores are the good indicators of the anthropogenic emissions over the last 60 years. The stable carbon isotope ratios of PAHs indicate the primary PAHs sources were the combustion of wood and coal during 1950s–1970s, and automobile exhausts and the coal combustion emissions in recent decades.

54 ENVIRONMENTAL SCIENCES↗

Secondary Pollutants from Ozone Reaction with Ventilation Filters and Degradation of Filter Media Additives

Prior research suggests that chemical processes taking place on the surface of particle filters employed in buildings may lead to the formation of harmful secondary byproducts. We investigated ozone reactions with fiberglass, polyester, cotton/polyester and polyolefin filter media, as well as hydrolysis of filter media additives. Studies were carried out on unused media, and on filters that were installed for 3 months in buildings at two different locations in the San Francisco Bay Area. Specimens from each filter media were exposed to {approx}150 ppbv ozone in a flow tube under a constant flow of dry or humidified air (50percent RH). Ozone breakthrough was recorded for each sample over periods of {approx}1000 min; the ozone uptake rate was calculated for an initial transient period and for steady-state conditions. While ozone uptake was observed in all cases, we did not observe significant differences in the uptake rate and capacity for the various types of filter media tested. Most experiments were performed at an airflow rate of 1.3 L/min (face velocity = 0.013 m/s), and a few tests were also run at higher rates (8 to 10 L/min). Formaldehyde and acetaldehyde, two oxidation byproducts, were quantified downstream of each sample. Those aldehydes (m/z 31 and 45) and other volatile byproducts (m/z 57, 59, 61 and 101) were also detected in real-time using Proton-Transfer Reaction - Mass Spectrometry (PTR-MS). Low-ppbv byproduct emissions were consistently higher under humidified air than under dry conditions, and were higher when the filters were loaded with particles, as compared with unused filters. No significant differences were observed when ozone reacted over various types of filter media. Fiberglass filters heavily coated with impaction oil (tackifier) showed higher formaldehyde emissions than other samples. Those emissions were particularly high in the case of used filters, and were observed even in the absence of ozone, suggesting that hydrolysis of additives, rather than ozonolysis, is the main formaldehyde source in those filters. Emission rates of formaldehyde and acetaldehyde were not found to be large enough to substantially increase indoor concentrations in typical building scenarios. Nevertheless, ozone reactions on HVAC filters cannot be ignored as a source of low levels of indoor irritants.

54 ENVIRONMENTAL SCIENCES↗

Persistent organic pollutants as predictors of increased FSH:LH ratio in naturally cycling, reproductive age women

Highlights: • Endocrine disrupting chemicals pose a threat to female fecundity and reproduction. • Examined organochlorines and a marker of ovarian responsivity, FSH:LH ratio. • Increasing concentrations of estrogenic PCBs predict FSH:LH ratio > 2. • PCB congeners related to airborne exposure are associated with FSH:LH ratio > 2. Although several recent studies suggest endocrine disrupting compounds, such as polychlorinated biphenyls (PCBs), dichlorodiphenyldichloroethylene (p,p′, DDE), and hexachlorobenzene (HCB), target different organs and systems in the body, their impact on female reproductive function in humans is not well characterized. We seek to determine the relationship between several known endocrine disrupting compounds and a marker of ovarian responsivity, the FSH:LH ratio (higher ratio indicates less ovarian responsivity). For this analysis, 169 naturally cycling women between 21 and 38 years of age completed interviews and had their blood drawn on day 3 of their menstrual cycle for analyses of toxicants, gonadal sex hormones (E{sub 2} and P{sub 4}), and gonadotropins (FSH and LH). PCB congeners were classified into five groups based on their environmental persistence, distribution in human tissue, and toxicological action, reflecting the structure, mechanism, and known biological activity of individual PCB congeners. For every unit (ppb) increase in the level of the estrogenic PCB group, there was a 5-fold greater risk of a FSH:LH ratio ≥ 2, controlling for individual differences in age, percent body fat, cycle day 3 estradiol levels, parity, alcohol use and cigarette smoking in the past year (exp[ß] = 5; p = ≤0.01). PCB congeners identified as estrogenic were analyzed individually, and, of the 19 potentially estrogenic congeners, five were significantly, and positively related to an increased FSH:LH ratio. Four of these congeners are non-persistent, easily volatilize in the environment, and are easily metabolized, and hence, are indicative of very recent or current exposure. p,p′-DDE and HCB were not associated with FSH:LH ratio. We find a clinical indicator of ovarian responsivity, FSH:LH ratio, is associated with a specific group of estrogenic PCBs. These congeners may become airborne when they volatilize from dredged PCB-contaminated soil or from indoor PCB-containing window caulk and sealants in older buildings leading to inhalation exposure. PCB exposure, particularly to non-persistent, estrogenic congeners, may pose an unrecognized threat to female fecundity within the general population.

54 ENVIRONMENTAL SCIENCES↗

Lung cancer and particulate pollution: A critical review of spatial and temporal analysis evidence

Particulate matter (PM) has been recognized as one of the key risk factors of lung cancer. However, spatial and temporal patterns of this association remain unclear. Spatiotemporal analyses incorporate the spatial and temporal structure of the data within random effects models, generating more accurate evaluations of PM-lung cancer associations at a scale that can better inform lung cancer prevention programs.

54 ENVIRONMENTAL SCIENCES↗