Computed versus measured ion velocity distribution functions in a Hall effect thruster

We compare time-averaged and time-varying measured and computed ion velocity distribution functions in a Hall effect thruster for typical operating conditions. The ion properties are measured by means of laser induced fluorescence spectroscopy. Simulations of the plasma properties are performed with a two-dimensional hybrid model. In the electron fluid description of the hybrid model, the anomalous transport responsible for the electron diffusion across the magnetic field barrier is deduced from the experimental profile of the time-averaged electric field. The use of a steady state anomalous mobility profile allows the hybrid model to capture some properties like the time-averaged ion mean velocity. Yet, the model fails at reproducing the time evolution of the ion velocity. This fact reveals a complex underlying physics that necessitates to account for the electron dynamics over a short time-scale. This study also shows the necessity for electron temperature measurements. Moreover, the strength of the self-magnetic field due to the rotating Hall current is found negligible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal mapping of ablated species in ultrafast laser-produced graphite plasmas

We studied the spatial and temporal distributions of ionic, neutral, and molecular species generated by femtosecond laser produced plasma under varying ambient nitrogen gas pressures. Plasmas were generated by irradiating planar graphite targets using 40 fs pulses of 800 nm radiation from a Ti:Sapphire laser. The results show that in the presence of an ambient gas, the molecular species spatial extension and lifetime are directly correlated to the evolution of excited ions. The present studies also provide valuable insights into the evolution history of various species and their excitation during ultrafast laser ablation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme ultraviolet spectroscopy and modeling of Cu on the SSPX Spheromak and laser plasma 'Sparky'

Impurities play a critical role in magnetic fusion research. In large quantities, impurities can cool and dilute plasma creating problems for achieving ignition and burn; however in smaller amounts the impurities could provide valuable information about several plasma parameters through the use of spectroscopy. Many impurity ions radiate within the extreme ultraviolet (EUV) range. Here, we report on spectra from the silver flat field spectrometer, which was implemented at the Sustained Spheromak Physics experiment (SSPX) to monitor ion impurity emissions. The chamber within the SSPX was made of Cu, which makes M-shell Cu a prominent impurity signature. The Spect3D spectral analysis code was utilized to identify spectral features in the range of 115-315 A and to more fully understand the plasma conditions. A second set of experiments was carried out on the compact laser-plasma x-ray/EUV facility 'Sparky' at UNR, with Cu flat targets used. The EUV spectra were recorded between 40-300 A and compared with results from SSPX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Streaked x-ray spectrometer having a discrete selection of Bragg geometries for Omega

The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO/QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic imaging system for measuring impurity line emission in a field-reversed configuration

A 16 chord optical tomography system has been developed and implemented in the flux coil generated-field reversed configuration (FRC). The chords are arranged in two fans of eight, which cover {approx}35% of the vessel area at the midplane. Each illuminate separate photomultiplier tubes (PMTs) which are fitted with narrow band-pass filters. In this case, filters are centered at 434.8 nm to measure emission from singly ionized argon. PMT crosstalk is negligible. Background noise due to electron radiation and H{sub {gamma}} line radiation is <10% of argon emission. The spatial resolution of the reconstruction is 1.5 cm. Argon is introduced using a puff valve and tube designed to impart the gas into the system as the FRC is forming. Reconstruction of experimental data results in time-dependent, 2D emissivity profiles of the impurity ions. Analysis of these data show radial, cross-field diffusion to be in the range of 10-10{sup 3} m{sup 2}/s during FRC equilibrium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute sensitivity calibration of vacuum and extreme ultraviolet spectrometer systems and Z{sub eff} measurement based on bremsstrahlung continuum in HL-2A tokamak

A grazing-incidence flat-field extreme ultraviolet (EUV) spectrometer has been newly developed in HL-2A tokamak. Typical spectral lines are observed from intrinsic impurities of carbon, oxygen, iron, and extrinsic impurity of helium in the wavelength range of 20 A-500 A. Bremsstrahlung continuum is measured at different electron densities of HL-2A discharges to calibrate absolute sensitivity of the EUV spectrometer system and to measure effective ionic charge, Z{sub eff}. The sensitivity of a vacuum ultraviolet (VUV) spectrometer system is also absolutely calibrated in overlapped wavelength range of 300 A-500 A by comparing the intensity between VUV and EUV line emissions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray tomography for real-time applications: present status at Tore Supra and possible future developments

This paper is focused on the soft x-ray (SXR) tomography system setup at Tore Supra (DTOMOX) and the recent developments made to automatically get precise information about plasma features from inverted data. The first part describes the main aspects of the tomographic inversion optimization process. Several observations are made using this new tool and a set of shape factors is defined to help characterizing the emissivity field in a real-time perspective. The second part presents a detailed off-line analysis comparing the positions of the magnetic axis obtained from a magnetic equilibrium solver, and the maximum of the reconstructed emissivity field for ohmic and heated pulses. A systematic discrepancy of about 5 cm is found in both cases and it is shown that this discrepancy increases during sawtooth crashes. Finally, evidence of radially localized tungsten accumulation with an in-out asymmetry during a lower hybrid current drive pulse is provided to illustrate the DTOMOX capabilities for a precise observation of local phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of collisional radiative models for edge electron density reconstruction from Li I (2s-2p) emission profiles

Four collisional radiative models (CRMs) for reconstruction of the edge electron density profile from the measured Li I (2s-2p) emission profile of an accelerated lithium beam are compared using experimental data from DIII-D. It is shown for both L- and H-mode plasmas that edge density profiles reconstructed with the CRMs DDD2, ABSOLUT, [Sasaki et al. Rev. Sci. Instrum. 64, 1699 (1993)] and a new model developed at DIII-D agree in a density scan from n{sub e}{sup ped}= (2.0-6.5) Multiplication-Sign 10{sup 19} m{sup -3} within 20%, 20%, <5%, and 40%, respectively, of the pedestal density measured with Thomson scattering. Profile shape and absolute density vary in a scan of the effective ion charge Z{sub eff}= 1-6 up to a factor of two but agree with Thomson data for Z{sub eff}= 1-2 within the error bars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of a multichannel millimeter wave interferometer for the Compact Toroidal Hybrid experiment

A three-channel 1 mm wave interferometer has been designed, assembled, and installed on the Compact Toroidal Hybrid torsatron (CTH). The interferometer design makes novel use of a subharmonic mixer for detection, which simplifies alignment. It employs a single electronically tunable source that is repetitively chirped using a sawtooth waveform of frequency up to 1 MHz. The 15.25 GHz drive oscillator is multiplied in two stages to 122 GHz before a final doubler stage brings it to 244 GHz. Local oscillator (LO) power at 122 GHz is directed through waveguide to the LO input of the subharmonic mixer of each viewing chord, simplifying alignment. Phase detection is performed by directly digitizing the amplified mixer outputs at 50 MHz and processing them with a software algorithm. Initial measurements made with the central chord of the new interferometer agree with those from the existing 4 mm system at low densities. The 1 mm system performs well in current-driven discharges reaching densities over 10{sup 19} m{sup -3}, whereas the lower frequency interferometer is found to be less reliable due to loss of fringes. This is a critical improvement for experiments studying the onset, avoidance, and vacuum magnetic transform dependence of disruptions in the CTH device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in compact proton spectrometers for inertial-confinement fusion and plasma nuclear science

Compact wedge-range-filter proton spectrometers cover proton energies {approx}3-20 MeV. They have been used at the OMEGA laser facility for more than a decade for measuring spectra of primary D{sup 3}He protons in D{sup 3}He implosions, secondary D{sup 3}He protons in DD implosions, and ablator protons in DT implosions; they are now being used also at the National Ignition Facility. The spectra are used to determine proton yields, shell areal density at shock-bang time and compression-bang time, fuel areal density, and implosion symmetry. There have been changes in fabrication and in analysis algorithms, resulting in a wider energy range, better accuracy and precision, and better robustness for survivability with indirect-drive inertial-confinement-fusion experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual transmission grating based imaging radiometer for tokamak edge and divertor plasmas

The designs of single transmission grating based extreme ultraviolet (XUV) and vacuum ultraviolet (VUV) imaging spectrometers can be adapted to build an imaging radiometer for simultaneous measurement of both spectral ranges. This paper describes the design of such an imaging radiometer with dual transmission gratings. The radiometer will have an XUV coverage of 20-200 A with a {approx}10 A resolution and a VUV coverage of 200-2000 A with a {approx}50 A resolution. The radiometer is designed to have a spatial view of 16 Degree-Sign , with a 0.33 Degree-Sign resolution and a time resolution of {approx}10 ms. The applications for such a radiometer include spatially resolved impurity monitoring and electron temperature measurements in the tokamak edge and the divertor. As a proof of principle, the single grating instruments were used to diagnose a low temperature reflex discharge and the relevant data is also included in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of characterizing laser-ablated carbon plasmas via planar laser induced fluorescence

Planar laser induced fluorescence (PLIF) imaging can potentially assess ion distributions and coupling in the context of super-Alfvenic ablation plasma expansions into magnetized background plasmas. In this feasibility study, we consider the application of PLIF to rapidly expanding carbon plasmas generated via energetic laser ablation of graphite. By utilizing hydrodynamic and collisional-radiative simulations, we identify schemes accessible to commercially available tunable lasers for the C I atom, the C II ion, and the C V ion. We then estimate the signal-to-noise ratios yielded by the schemes under reasonable experimental configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time resolved optical emission images of an atmospheric pressure plasma jet with transparent electrodes

We study development of plasma packages in atmospheric pressure plasma jet from their formation as a discharge close to the instantaneous cathode, following their motion between and inside the electrodes up to their emergence at the edge of the glass tube and formation of a plasma bullet. Inside both electrodes, plasma is concentrated close to the walls and is bright, while outside it is located at the axis. This paper opens issues of the geometry of electrodes, fields, and atomic processes, allowing some predictions to be made about pertinent mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating the pressure of laser-induced plasma shockwave by stimulated Raman shift of lattice translational modes

The current paper investigates stimulated Raman scattering (SRS) when laser-induced plasma is formed in heavy water by focusing an intense pulsed 532 nm Nd:YAG laser beam at room temperature. An unexpected low-frequency SRS line attributed to the lattice translational modes of ice-VII (D{sub 2}O) is observed. The pressure of the plasma shockwave is estimated using low-frequency SRS line shift.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependence of terahertz power from laser-produced plasma on laser intensity

Power of terahertz radiation from plasma which is generated from air irradiated by coupled ({omega}, 2{omega}) femtosecond laser pulses is analyzed for high laser intensities, for which non-linear plasma effects on the pulse propagation become essential, with multidimensional particle-in-cell simulations including the self-consistent plasma kinetics. The growth rate of THz power becomes slower as the laser intensity increases. A reason of such a lowering of efficiency in THz emission is found to be ionization of air by the laser pulse, which results in poor focusing of laser pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond laser-plasma interaction with prepulse-generated liquid metal micro-jets

Ultra-short laser pulse interaction with a micro-structured surface of a melted metal is a promising source of hard X-ray radiation. Micro-structuring is achieved by a weak prepulse which produces narrow high density micro-jets. Interaction of the main laser pulse with such jets is shown to be a 100 times more efficient X-ray source than ordinary metal targets. This paper presents the results of optical and x-ray studies of laser-plasma interaction physics under such conditions supported by numerical simulations of fast electron generation.

07 ISOTOPE AND RADIATION SOURCES↗

Stable formation of ultrahigh power-density 248 nm channels in Xe cluster targets

The optimization of relativistic and ponderomotive self-channeling of ultra-powerful 248 nm laser pulses launched in underdense plasmas with an appropriate longitudinal gradient in the electron density profile located at the initial stage of the self-channeling leads to (1) stable channel formation and (2) highly efficient power compression producing power densities in the 10{sup 19}-10{sup 20} W/cm{sup 3} range. The comparison of theoretical studies with experimental results involving the correlation of (a) Thomson images of the electron density with (b) x-ray images of the channel morphology demonstrates that more than 90% of the incident 248 nm power can be trapped in stable channels and that this stable propagation can be extended to power levels significantly exceeding the critical power of the self-channeling process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrades of the high resolution imaging x-ray crystal spectrometers on experimental advanced superconducting tokamak

Two imaging x-ray crystal spectrometers, the so-called 'poloidal' and 'tangential' spectrometers, were recently implemented on experimental advanced superconducting tokamak (EAST) to provide spatially and temporally resolved impurity ion temperature (T{sub i}), electron temperature (T{sub e}) and rotation velocity profiles. They are derived from Doppler width of W line for Ti, the intensity ratio of Li-like satellites to W line for Te, and Doppler shift of W line for rotation. Each spectrometer originally consisted of a spherically curved crystal and a two-dimensional multi-wire proportional counter (MWPC) detector. Both spectrometers have now been upgraded. The layout of the tangential spectrometer was modified, since it had to be moved to a different port, and the spectrometer was equipped with two high count rate Pilatus detectors (Model 100 K) to overcome the count rate limitation of the MWPC and to improve its time resolution. The poloidal spectrometer was equipped with two spherically bent crystals to record the spectra of He-like and H-like argon simultaneously and side by side on the original MWPC. These upgrades are described, and new results from the latest EAST experimental campaign are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗