Clock synchronization of a large multiprocessor system in the presence of malicious faults
An interconnection algorithm is presented for achieving clock synchronization in a multiprocessor system. The system is assumed to be maliciously faulty, i.e., some processors are out of synchronization and lie about their clock state to other intragroup or intergroup processors. A phase-locked clock network design is proposed which groups the clocks in the system into diverse clusters. The clusters are then treated as single clock units from the perspective of the network. The algorithm minimizes the number of interconnections while permitting synchronization of large multiprocessor systems controlling time-critical applications such as aircraft, nuclear reactors and industrial processes.