Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PAIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Fast approximation to supershell partition functions: Explicit forms of the coefficients

In a previous work, we derived a formula for supershell partition functions, which are the cornerstone of the Super-Transition-Array approach to radiative-opacity calculations. The new expression takes the form of a functional of the distribution of energies within the supershell and allows for fast and accurate computations, truncating the number of terms in the expansion. The latter involves coefficients (denoted Γ $k$ ) for which we obtained a recursion relation. In the present short paper, as a complement of the previous one, we give an explicit formula for the coefficients Γ $k$ . Another recursion relation is also provided, as well as an alternative expression involving Bell polynomials. In conclusion, the connections with cycle indexes of permutation groups and with elementary symmetric polynomials are outlined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the computation of moments in the Super-Transition-Arrays model for radiative opacity calculations

In the Super-Transition-Array statistical method for the computation of radiative opacity of hot dense matter, the moments of the absorption or emission features involve partition functions with reduced degeneracies, occurring through the calculation of averages of products of subshell populations. Here, in the present work, we discuss several aspects of the computation of such peculiar partition functions, insisting on the precautions that must be taken in order to avoid numerical difficulties. In a previous work, we derived a formula for supershell partition functions, which takes the form of a functional of the distribution of energies within the supershell and allows for fast and accurate computations, truncating the number of terms in the expansion. The latter involves coefficients for which we obtained a recursion relation and an explicit formula. We show that such an expansion can be combined with the recurrence relation for shifted partition functions. We also propose, neglecting the effect of fine structure as a first step, a positive-definite formula for the Super-Transition-Array moments of any order, providing an insight into the asymmetry and sharpness of the latter. The corresponding formulas are free of alternating sums. Several ways to speed up the calculations are also presented.

74 ATOMIC AND MOLECULAR PHYSICS↗

A new approach to include electron interaction effects in super transition array opacity theory

A method is presented for the improved calculation of super-shell partition functions which include the repulsive electron–electron interaction energy terms in the Boltzmann factor. Heretofore these interaction terms were approximately treated via the use of Feynman–Jensen inequalities. Further, such investigations are of particular interest for the super-transition-array approach of hot-plasma radiative opacity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Clinical and Dosimetric Predictors of Late Rectal Syndrome After 3D-CRT for Localized Prostate Cancer: Preliminary Results of a Multicenter Prospective Study

Purpose: To assess the predictors of late rectal toxicity in a prospectively investigated group of patients treated at 70-80 Gy for prostate cancer (1.8-2 Gy fractions) with three-dimensional conformal radiotherapy. Methods and Materials: A total of 1,132 patients were entered into the study between 2002 and 2004. Three types of rectal toxicity, evaluated by a self-administered questionnaire, mainly based on the subjective objective management, analytic late effects of normal tissue system, were considered: stool frequency/tenesmus/pain, fecal incontinence, and bleeding. The data from 506 patients with a follow-up of 24 months were analyzed. The correlation between a number of clinical and dosimetric parameters and Grade 2 or greater toxicity was investigated by univariate and multivariate (MVA) logistic analyses. Results: Of the 1,132 patients, 21, 15, and 30 developed stool frequency/tenesmus/pain, fecal incontinence, and bleeding, respectively. Stool frequency/tenesmus/pain correlated with previous abdominal/pelvic surgery (MVA, p = 0.05, odds ratio [OR], 3.3). With regard to incontinence, MVA showed the volume receiving {>=}40 Gy (V{sub 40}) (p = 0.035, OR, 1.037) and surgery (p = 0.02, OR, 4.4) to be the strongest predictors. V{sub 40} to V{sub 70} were highly predictive of bleeding; V{sub 70} showed the strongest impact on MVA (p = 0.03), together with surgery (p = 0.06, OR, 2.5), which was also the main predictor of Grade 3 bleeding (p = 0.02, OR, 4.2). Conclusions: The predictive value of the dose-volume histogram was confirmed for bleeding, consistent with previously suggested constraints (V{sub 50} <55%, V{sub 60} <40%, V{sub 70} <25%, and V{sub 75} <5%). A dose-volume histogram constraint for incontinence can be suggested (V{sub 40} <65-70%). Previous abdominal/pelvic surgery correlated with all toxicity types; thus, a modified constraint for bleeding (V{sub 70} <15%) can be suggested for patients with a history of abdominal/pelvis surgery, although further validation on a larger population with longer follow-up is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimising the error in eigenvalue calculations involving the Boltzmann transport equation using goal-based adaptivity on unstructured meshes

This article presents a method for goal-based anisotropic adaptive methods for the finite element method applied to the Boltzmann transport equation. The neutron multiplication factor, k{sub eff}, is used as the goal of the adaptive procedure. The anisotropic adaptive algorithm requires error measures for k{sub eff} with directional dependence. General error estimators are derived for any given functional of the flux and applied to k{sub eff} to acquire the driving force for the adaptive procedure. The error estimators require the solution of an appropriately formed dual equation. Forward and dual error indicators are calculated by weighting the Hessian of each solution with the dual and forward residual respectively. The Hessian is used as an approximation of the interpolation error in the solution which gives rise to the directional dependence. The two indicators are combined to form a single error metric that is used to adapt the finite element mesh. The residual is approximated using a novel technique arising from the sub-grid scale finite element discretisation. Two adaptive routes are demonstrated: (i) a single mesh is used to solve all energy groups, and (ii) a different mesh is used to solve each energy group. The second method aims to capture the benefit from representing the flux from each energy group on a specifically optimised mesh. The k{sub eff} goal-based adaptive method was applied to three examples which illustrate the superior accuracy in criticality problems that can be obtained.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Goal-based angular adaptivity applied to a wavelet-based discretisation of the neutral particle transport equation

A method for applying goal-based adaptive methods to the angular resolution of the neutral particle transport equation is presented. The methods are applied to an octahedral wavelet discretisation of the spherical angular domain which allows for anisotropic resolution. The angular resolution is adapted across both the spatial and energy dimensions. The spatial domain is discretised using an inner-element sub-grid scale finite element method. The goal-based adaptive methods optimise the angular discretisation to minimise the error in a specific functional of the solution. The goal-based error estimators require the solution of an adjoint system to determine the importance to the specified functional. The error estimators and the novel methods to calculate them are described. Several examples are presented to demonstrate the effectiveness of the methods. It is shown that the methods can significantly reduce the number of unknowns and computational time required to obtain a given error. The novelty of the work is the use of goal-based adaptive methods to obtain anisotropic resolution in the angular domain for solving the transport equation. -- Highlights: •Wavelet angular discretisation used to solve transport equation. •Adaptive method developed for the wavelet discretisation. •Anisotropic angular resolution demonstrated through the adaptive method. •Adaptive method provides improvements in computational efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A POD reduced order model for resolving angular direction in neutron/photon transport problems

This article presents the first Reduced Order Model (ROM) that efficiently resolves the angular dimension of the time independent, mono-energetic Boltzmann Transport Equation (BTE). It is based on Proper Orthogonal Decomposition (POD) and uses the method of snapshots to form optimal basis functions for resolving the direction of particle travel in neutron/photon transport problems. A unique element of this work is that the snapshots are formed from the vector of angular coefficients relating to a high resolution expansion of the BTE's angular dimension. In addition, the individual snapshots are not recorded through time, as in standard POD, but instead they are recorded through space. In essence this work swaps the roles of the dimensions space and time in standard POD methods, with angle and space respectively. It is shown here how the POD model can be formed from the POD basis functions in a highly efficient manner. The model is then applied to two radiation problems; one involving the transport of radiation through a shield and the other through an infinite array of pins. Both problems are selected for their complex angular flux solutions in order to provide an appropriate demonstration of the model's capabilities. It is shown that the POD model can resolve these fluxes efficiently and accurately. In comparison to high resolution models this POD model can reduce the size of a problem by up to two orders of magnitude without compromising accuracy. Solving times are also reduced by similar factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Results of Helical Tomotherapy in Patients with Complex-Shaped Meningiomas Close to the Optic Pathway

Meningiomas are the most common benign intracranial tumor. Meningiomas close to the optic pathway represent a treatment challenge both for surgery and radiotherapy. The aim of this article is to describe early results of helical tomotherapy treatment in complex-shaped meningiomas close to the optic pathway. Twenty-eight patients were consecutively treated. All patients were immobilized with a thermoplastic head mask and planned with the aid of a magnetic resonance imaging-computed tomography fusion. All treatments included daily image guidance. Pretreatment symptoms and acute toxicity were recorded. Median age was 57.5 years, and 92.8% patients had Eastern Cooperative Oncology Group performance status scale {<=}1. The most common localizations were the sella turcica, followed by the cavernous sinus and the sphenoid. The most common symptoms were derived from cranial nerve deficits. Tomotherapy was administered as primary treatment in 35.7% of patients, as an adjuvant treatment in 32.4%, and as a rescue treatment after postsurgical progression in 32.1% patients. Most patients were either inoperable or Simpson IV. Total dose varied between 5000 and 5400 cGy; fractionation varied between 180 and 200 cGy. Median dose to the planning target volume was 51.7 Gy (range, 50.2-55.9 Gy). Median coverage index was 0.89 (range, 0.18-0.97). Median homogeneity index was 1.05 (range, 1-1.12). Acute transient toxicity was grade 1 and included headache in 35.7% patients, ocular pain/dryness in 28.5%, and radiation dermatitis in 25%. Thus far, with a maximal follow-up of 3 years, no late effects have been seen and all patients have a radiological stabilization of the disease. Helical tomotherapy offered a safe and effective therapeutic alternative for patients with inoperable or subtotally resected complex-shaped meningiomas close to the optic pathway. Acceptable coverage and homogeneity indexes were achieved with appropriate values for maximal doses delivered to the eyes, lenses, and chiasm, despite the proximity of the tumor to these structures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design of SECAR a recoil mass separator for astrophysical capture reactions with radioactive beams

A recoil mass separator SECAR has been designed for the purpose of studying low-energy (p,γ) and (α,γ) reactions in inverse kinematics with radioactive beams for masses up to about A = 65. Their reaction rates are of importance for our understanding of the energy production and nucleosynthesis during explosive hydrogen and helium burning. The radiative capture reactions take place in a windowless hydrogen or He gas target at the entrance of the separator, which consists of four Sections . The first Section selects the charge state of the recoils. The second and third Sections contain Wien Filters providing high mass resolving power to separate efficiently the intense beam from the few reaction products. In the following fourth Section , the reaction products are guided into a detector system capable of position, angle and time-of-flight measurements. In order to accept the complete kinematic cone of recoil particles including multiple scattering in the target in the center of mass energy range of 0.2 MeV to 3.0 MeV, the system must have a large polar angle acceptance of ± 25 mrad. This requires a careful minimization of higher order aberrations. Furthermore, the present system will be installed at the NSCL ReA3 accelerator and will be used with the much higher beam intensities of the FRIB facility when it becomes available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an array of liquid-scintillator-based bar detectors: SABRE

We present that an array of neutron detectors based on liquid scintillator technology has been developed for nuclear reaction studies, in particular measurements with radioactive ion beams (RIBs). Reaction measurements with RIBs often involve low reaction yields and high gamma-induced backgrounds, which requires high solid angle coverage, high efficiency, and background reduction capability. The kinematics of the reaction neutrons require energy and position determination with good resolution, but preferably without a large number of readouts to minimize cost. To address these requirements, the Scintillation Array of Bars for Reaction Experiments (SABRE) consists of five 12” long, 2” diameter bar detectors filled with organic liquid scintillator and capped at both ends with individually read-out superbialkali photomultiplier tubes (PMTs). Finally, in-house purification of the scintillator mixtures resulted in improved light collection. Discussion of the liquid scintillator development and the design and commissioning of SABRE will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the JENSA gas-jet target for experiments with rare isotope beams

The JENSA gas-jet target was designed for experiments with radioactive beams provided by the rare isotope re-accelerator ReA3 at the National Superconducting Cyclotron Laboratory. The gas jet will be the main target for the Separator for Capture Reactions SECAR at the Facility for Rare Isotope Beams on the campus of Michigan State University, USA. We describe the advantages of a gas-jet target, detail the current recirculating gas system, and report recent measurements of helium jet thicknesses of up to about 10 19 atoms/cm 2 . A comparison with other supersonic gas-jet targets is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Compton scattering for gamma beam intensity measurements and perspectives at ELI-NP

Compton γ-ray sources have been used for over 30 years with new facilities being under construction or proposed. The gamma beam system under implementation at the Extreme Light Infrastructure - Nuclear Physics facility in Romania will deliver brilliant γ-ray beams with energies up to 19.5 MeV. Several instruments for measuring the parameters of the γ-ray beam are under development at ELI-NP. One of these instruments based on a High Purity Germanium detector is typically used for beam energy measurements at other facilities. Here we investigate the use of a High Purity Germanium detector to continuously monitor the intensity of the ELI-NP gamma beam by measuring the inelastic scattering of photons. This technique relies on both experimental and simulated data and it has been successfully tested during a recent experiment at the High Intensity γ-ray Source facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of neutron spectrum unfolding using deuterated liquid scintillator

The performance of the maximum likelihood expectation maximization method for unfolding neutron energy spectra using deuterated liquid scintillator is evaluated for future utilization with rare isotope beams. High-resolution neutron energy spectra as well as the detector response matrix were measured at the Edwards Accelerator Laboratory at Ohio University. Maximum-likelihood expectation maximization (MLEM) unfolded neutron spectra are compared with spectra from neutron time-of-flight. In conclusion, the effects of the MLEM stopping criteria and spectrum statistics are also investigated.

47 OTHER INSTRUMENTATION↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Object detection with deep learning for rare event search in the GADGET II TPC

In the pursuit of identifying rare two-particle events within the GADGET II Time Projection Chamber (TPC), this paper presents a comprehensive approach for leveraging Convolutional Neural Networks (CNNs) and various data processing methods. To address the inherent complexities of 3D TPC track reconstructions, the data is expressed in 2D projections and 1D quantities. This approach capitalizes on the diverse data modalities of the TPC, allowing for the efficient representation of the distinct features of the 3D events, with no loss in topology uniqueness. Additionally, it leverages the computational efficiency of 2D CNNs and benefits from the extensive availability of pre-trained models. Given the scarcity of real training data for the rare events of interest, simulated events are used to train the models to detect real events. To account for potential distribution shifts when predominantly depending on simulations, significant perturbations are embedded within the simulations. This produces a broad parameter space that works to account for potential physics parameter and detector response variations and uncertainties. These parameter-varied simulations are used to train sensitive 2D CNN object detectors. When combined with 1D histogram peak detection algorithms, this multi-modal detection framework is highly adept at identifying rare, two-particle events in data taken during experiment 21072 at the Facility for Rare Isotope Beams (FRIB), demonstrating a 100% recall for events of interest. Here, we present the methods and outcomes of our investigation and discuss the potential future applications of these techniques.

Convolutional neural network↗