Thermal comfort evaluated for combinations of energy-efficient personal heating and cooling devices

Personal comfort systems (PCS) have potential to fulfill building occupants' personal thermal comfort preferences with great efficiency. But to integrate them into building conditioning, there must be a broader selection of PCS devices available. Design guidance and standards are needed to assure that such devices provide high levels of comfort effectiveness and energy efficiency. This study addresses these needs. A suite of minimum-power PCS devices was built that target body parts significant to alliesthesia—a heated shoe insole, heated/cooled wristpad, small deskfan, and heated/cooled chair. They were tested in a climate chamber under cool and warm conditions using both thermal-manikin and human-subjects. Their efficiency at physically heating/cooling the body is high; the combined suite has a coefficient of performance (COP) of 3.6 for cooling and 0.88 for heating. The subjects' whole-body thermal acceptance and thermal comfort perception were improved by the devices in an additive manner; using the combined suite over 80% of people accepted ambient temperatures of 18°C and 29°C. The PCS ‘corrects’ the ambient temperature towards thermal neutrality by as much as 6.5 K cooling and 3.6 K heating, overcoming building occupants' typical interpersonal thermal differences and making possible large HVAC energy savings in buildings. The idea of temperature corrective power can be the basis of standards for PCS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Split-pane electrochromic window control based on an embedded photometric device with real-time daylighting computing

Well-designed electrochromic (EC) glazing control can improve the energy performance of buildings and visual comfort of occupants in highly glazed buildings. Here in this paper, we designed and demonstrated a compact integrated EC glazing automation system to control tint states of a split-pane EC window according to variations of sky conditions. The control is based on monitoring the luminance distribution of the sky and real-time lighting computation for a building interior, using an embedded photometric device (EPD). It optimizes tint states of EC glazing to offer sufficient daylight provision and temper discomfort glare for occupants, which potentially mitigates excessive solar heat gain. ’In-situ’ experiments were conducted in a full-scale testbed to demonstrate the daylighting performance under various sky conditions. Finally, experimental results showed 83% of the working time for work-plane illuminance (WPI) and 95% of the time for daylight glare probability (DGP) were constrained in comfort range (WPIϵ[500, 2000] lux, DGP ≤ 0.35) by the automated EC glazing (controlled by EPD) under clear skies; 68% of the time for WPI and 94% of the time for DGP in confined range under clear skies with thin clouds; 62% of the time for WPI and 85% of the time for DGP in confined range under partly cloudy skies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Association of residential energy efficiency retrofits with indoor environmental quality, comfort, and health: A review of empirical data

This paper reviews empirical data from evaluations of the influence of residential energy efficiency retrofits on indoor environmental quality conditions and self-reported thermal comfort and health. The data were extracted from 36 studies described in 44 papers plus two reports. Nearly all reviewed studies were performed in Europe or United States. Most studies evaluated retrofits of homes with low-income occupants. Indoor radon and formaldehyde concentrations tended to increase after retrofits that did not add whole-house mechanical ventilation. Study-average indoor concentrations of nitrogen dioxide and volatile organic compounds other than formaldehyde increased and decreased with approximately equal frequency. Average indoor temperatures during winter typically increased after retrofits, usually by less than 1.5 °C. Dampness and mold, usually based on occupant's reports, almost always decreased after retrofits. Subjectively reported thermal comfort, thermal discomfort, non-asthma respiratory symptoms, general health, and mental health nearly always improved after retrofits. For asthma symptoms, the evidence of improvement slightly outweighed the evidence of worsening. There was insufficient evidence to determine whether changes in thermal comfort and health outcomes varied depending on the type of energy efficiency retrofit. The published research has numerous limitations including a lack of data from retrofits in warm-humid climates and minimal data on changes in objective health outcomes. Suggestions for future research are provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impacts of building characteristics, social psychological and cultural factors on indoor environment quality productivity belief

Indoor environmental quality (IEQ) plays a key role in determining occupants' productivity at work; however, analyses of the interconnected factors among building physical, attitudinal, social and demographic components in one study are lacking. To fill this research gap, this study investigates these interconnected factors' influence on occupants’ IEQ-productivity belief, defined as a personal, subjective evaluation of the linkage between the impacts of five IEQ aspects (the quality of indoor temperature, air, natural and electric lighting, and acoustics) and productivity. A cross-sectional survey data was collected in university offices from six countries (Brazil, Italy, Poland, Switzerland, Taiwan and the U.S.). Results of multiple linear regression models indicate that IEQ satisfaction is the strongest positive predictor of the IEQ-productivity belief and this relationship is stronger in private offices. Country of residence is the second primary predictor. Several attitudinal-behavioral factors, including thermal comfort, perceived ease of controlling indoor environmental features, and attitudes toward sharing controls are all positively associated with IEQ-productivity belief. Interestingly, the level of control accessibility to light switches has the strongest impact as opposed to other controls. On the other hand, group norms and conformity intention are not significant predictors. Regarding demographics, men are more likely than women to perceive the IEQs to have positive impacts on their productivity, without considering other variables in the regression model; however, women are more likely than men to consider all IEQs as having positive impacts on productivity, after considering other variables. Furthermore, our findings provide suggestions for prioritizing wellness in the workplace since the early design stage.

99 GENERAL AND MISCELLANEOUS↗

Assessing the use of portable air cleaners for reducing exposure to airborne diseases in a conference room with thermal stratification

The COVID-19 pandemic has highlighted the need for strategies that mitigate the risk of aerosol disease transmission in indoor environments with different ventilation strategies. It is necessary for building operators to be able to estimate and compare the relative impacts of different mitigation strategies to determine suitable strategies for a particular situation. Using a validated CFD model, this study simulates the dispersion of exhaled contaminants in a thermally stratified conference room with overhead heating. The impacts of portable air-cleaners (PACs) on the room airflow and contaminant distribution were evaluated for different PAC locations and flow rates, as well as for different room setups (socially distanced or fully occupied). To obtain a holistic view of a strategy's impacts under different release scenarios, we simultaneously model the steady-state distribution of aerosolized virus contaminants from eight distinct sources in 18 cases for a total of 144 release scenarios. The simulations show that the location of the source, the PAC settings, and the room set-up can impact the average exposure and PAC effectiveness. For this studied case, the PACs reduced the room average exposure by 31%-66% relative to the baseline case. Some occupant locations were shown to have a higher-than-average exposure, particularly those seated near the airflow outlet, and occupants closest to sources tended to see the highest exposure from said source. We found that these PACs were effective at reducing the stratification caused by overhead heating, and also identified at least one sub-optimal location for placing a PAC in this space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of overhead HVAC and aerosol control strategies on coarse mode particle dispersion and exposure in a full-scale room experiment

Coarse mode respiratory aerosols can carry viral loads over long distances and have very different dynamics than submicron particles, but experimental studies under realistic conditions remain limited. Here, to study the differential impacts on exposure under different mixing conditions, we co-released 7–10 µm particles and carbon dioxide (CO 2 )—which served as an indicator of gas and submicron particle dynamics—in a 158 m 3 room at LBNL's FLEXLAB facility with an overhead heating, ventilation, and air conditioning (HVAC) system. The room was arranged as a distanced meeting then a classroom with eight heated manikins and a researcher. Spatial variability was measured using 16 particle counters and 22–26 CO 2 sensors throughout the space. Conditions included: HVAC off or supply air at 1000-1060 m 3 h -1 at neutral, cooling, or heating temperatures; with and without 20% outdoor air; and added HVAC filtration, portable air cleaners (PACs), or a physical barrier between the speaker and occupants. We found that good mixing via neutral or cooling supply air or use of PACs under heating lowered coarse particle exposure at some locations, but increased exposure for one-quarter to two-thirds of manikins compared to poor mixing under heating. A physical barrier reduced direct transfer of coarse particles during heating, but less during cooling. High spatial variability shows that a single measurement cannot represent occupant exposure. Instantaneous air mixing assumptions overstate the effectiveness of ventilation, HVAC filtration, and upper-room germicidal ultraviolet disinfection for coarse particles, as relatively few particles reach the return grille or upper room under most conditions.

Air mixing↗

Multisublattice cluster expansion study of short-range ordering in iron-substituted strontium titanate

Owing to the challenges in obtaining realistic atomic configurations in large chemical phase spaces, it is not straightforward to describe structure–property relations in materials exhibiting configurational disorder. One example is iron-substituted strontium titanate (SrTi 1–x Fe x O 3–d , STF), a promising perovskite-derivative cathode material in solid oxide fuel cells that exhibits full solid solubility 0 ≤ x ≤ 1 and a tendency to exhibit short-range order. Here we demonstrate a multisublattice cluster expansion (CE) framework and apply it to STF across the full composition range. The CE approach is distinct from more traditional CE formulations in that clusters are defined explicitly by the chemical species distributed among multiple sublattices, rather than via cluster functions of occupation variables with decoration. The modified CE approach makes it easy to distinguish meaningful chemical interactions that are harder to extract from conventional CE, since for the latter chemical identity in a cluster is expressed as a product of site occupations. The least absolute shrinkage and selection operator (LASSO) is implemented as a regression analysis tool to select key clusters and avoid overfitting. We demonstrate this formulation on STF, and show that it can accurately predict configurational energies in comparison to conventional CE. From the key clusters, we identify that short-range ordering between substitutional Fe and oxygen vacancies (V O ) results in the formation of Fe–VO strings. In addition, we consider the stability of STF through CE-based Monte Carlo (MC) simulations and confirm the presence of superstructures that were previously observed in transmission electron microscopy. In this work, analysis of atomic configurations from MC samples reveals variations in the oxidation state of Fe atoms, which can be explained by the ordering tendency of Fe and V O . The cluster description and selection formalism described here may be applied to other disordered multisublattice systems for accurate and efficient material modeling.

36 MATERIALS SCIENCE↗

The apparent absence of chemical sensitivity in the 4d and 5d X-ray absorption spectroscopy of uranium compounds

X-ray absorption spectroscopy (XAS) and related derivative measurements have been used to demonstrate that the Pu 5f states are strongly relativistic and have a 5f occupation number near 5. Owing to the success in this regime, it has been argued that the XAS measurements should be a powerful tool to probe 5f occupation variation, both as a function of elemental nature (actinide atomic number) and as a function of physical and chemical perturbation, e.g., oxidation state. We show that XAS and its related measurements fail in this latter aspect for a wide variety of uranium compounds and materials. Possible causes will be discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sharing is caring: An extensive analysis of parameter-based transfer learning for the prediction of building thermal dynamics

In recent years deep neural networks have been proposed as a lightweight data-driven model to capture high-dimensional, nonlinear physical processes to predict building thermal responses. However, the need of a large amount of data for the training process of deep neural networks clashes with the potential limited data availability in most existing or new buildings. Transfer learning aims to enhance the performance of a target learner exploiting knowledge from related and similar environments. This study conducted a suite of experiments that leveraged 250 data-driven models based on a synthetic dataset of a building archetype to study the influence of data availability, energy efficiency level, occupancy and climate for the transfer process of thermal dynamics. The performance of the transfer learning process was compared against a classical machine learning approach. Here, the results suggest that building thermal dynamics can be effectively transferred under the same climatic conditions, increasing performance when dealing with different occupancy schedules, efficiency levels and low data availability. Furthermore, the paper compares the performance of both transfer learning and machine learning approaches in an online fashion, to support the implementation in real-world deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cashew nut roasting: Chemical characterization of particulate matter and genotocixity analysis

Background: Particulate matter (PM) is potentially harmful to health and related to genotoxic events, an increase in the number of hospitalizations and mortality from respiratory and cardiovascular diseases. The present study conducted the first characterization of elemental composition and polycyclic aromatic hydrocarbon (PAH) analysis of PM, as well as the biomonitoring of genotoxic activity associated to artisanal cashew nut roasting, an important economic and social activity worldwide. Methods: The levels of PM{sub 2.5} and black carbon were also measured by gravimetric analysis and light reflectance. The elemental composition was determined using X-ray fluorescence spectrometry and PAH analysis was carried out by gas chromatography–mass spectrometry. Genotoxic activity was measured by the Tradescantia pallida micronucleus bioassay (Trad-MCN). Other biomarkers of DNA damage, such as nucleoplasmic bridges and nuclear fragments, were also quantified. Results: The mean amount of PM{sub 2.5} accumulated in the filters (January 2124.2 µg/m{sup 3}; May 1022.2 µg/m{sup 3}; September 1291.9 µg/m{sup 3}), black carbon (January 363.6 µg/m{sup 3}; May 70 µg/m{sup 3}; September 69.4 µg/m{sup 3}) and concentrations of Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Se, Br and Pb were significantly higher than the non-exposed area. Biomass burning tracers K, Cl, and S were the major inorganic compounds found. Benzo[k]fluoranthene, indene[1,2,3-c,d]pyrene, benzo[ghi]perylene, phenanthrene and benzo[b]fluoranthene were the most abundant PAHs. Mean benzo[a]pyrene-equivalent carcinogenic power values showed a significant cancer risk. The Trad-MCN bioassay revealed an increase in micronucleus frequency, 2–7 times higher than the negative control and significantly higher in all the months analyzed, possibly related to the mutagenic PAHs found. Conclusions: This study demonstrated that artisanal cashew nut roasting is a serious occupational problem, with harmful effects on workers' health. Those involved in this activity are exposed to higher PM{sub 2.5} concentrations and to 12 PAHs considered potentially mutagenic and/or carcinogenic. The Trad-MCN with T. pallida was sensitive and efficient in evaluating the genotoxicity of the components and other nuclear alterations may be used as effective biomarkers of DNA damage. - Highlights: • The cashew nut roasting generated high concentrations of particulate matter fine. • The biomass burning tracers K, Cl, S were the major inorganic compounds found. • It was identified 12 PAHs considered to be potentially mutagenic and/or carcinogenic. • The genotoxic potential of this activity was confirmed by the Trad MCN assay. • This activity is a serious occupational problem with harmful effects to health workers.

54 ENVIRONMENTAL SCIENCES↗

Mercury concentrations in urine of amerindian populations near oil fields in the peruvian and ecuadorian amazon

Background: Mercury is a global contaminant with toxic, persistent effects on human health. Petroleum extraction is an important source of elemental mercury; little is known about human exposure levels near oil fields in the Amazon basin. Objectives: To characterize mercury levels in people living near oil production sites in the Peruvian and Ecuadorian Amazon, controlling for fish consumption, occupation, source of water and socio-demographic characteristics. Methods: Analyze mercury levels in urine samples using cold vapour atomic fluorescence spectrometry from 76 indigenous men and women in eight riverine communities situated near oil wells or pipelines. Subjects answered a questionnaire soliciting socio-demographic, occupational and dietary information. Data were analyzed using multiple linear regression modeling. Results: The mean value of U-Hg was 2.61 μg/g creatinine (95% CI: 2.14–3.08), with 7% of the sample recording values above the global background standard suggested by The World Health Organization (5 μg/g creatinine). Women who used water from a surface source had two and a half times the amount of mercury in their urine (mean=3.70 μg/g creatinine, 95% CI: 2.26–5.15) compared with women who used other water sources (mean =1.39 μg/g creatinine, 95% CI: 0.51–2.25). Men who were involved in an oil clean-up operation had twice as much mercury in their urine (mean =3.07 μg/g creatinine, 95% CI: 1.97–4.16) as did those who worked on other tasks (mean =1.56 μg/g creatinine, 95% CI: 1.48–2.65). Mercury levels were not associated with the number of fish meals per week. Conclusions: Indigenous peoples of the Peruvian and Ecuadorian Amazon living near oil production sites generally had urine mercury levels within the global background standard suggested by the World Health Organization. Increased levels of mercury in urine were detected for men involved in oil spill remediation and for women who relied on surface water for household needs. These findings signal the need for strict safety measures to limit the amount of oil entering the waterways in Andean Amazonia so as to protect the health of indigenous people. - Highlights: • 7% of participants had levels of inorganic mercury at or exceeding levels suggested by WHO (5 μg/g creatinine). • U-Hg levels were 2.5 times higher among women using surface water than those who drew on water from a well, spring or rain. • Men who had worked cleaning up an oil spill had more than twice the amount of mercury in their urine as men who did not.

54 ENVIRONMENTAL SCIENCES↗

Radio frequency radiation-related cancer: assessing causation in the occupational/military setting

Highlights: • Carcinogenicity of radio frequency radiation (RFR) was examined. • The focus was on hemolymphatic cancers in the occupational and military settings. • Unusually high proportion of hemolymphatic cancers was found in a case series. • Similar unusually high proportions were reported in three previous cohort studies. • The findings support a case for classifying RFR as a human carcinogen. We reexamine whether radio frequency radiation (RFR) in the occupational and military settings is a human carcinogen.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Factors determining the exposure of dairy farmers to thoracic organic dust

Highlights: • Dairy farming exposes to thoracic dusts containing bacteria and moulds. • Specific tasks and farm characteristics control exposures to thoracic organic dusts. • Temperature and hygrometry also control the levels of organic dust exposure. Bronchial respiratory diseases are more common in dairy farmers than in the general population, perhaps because the repeated inhalation of organic dust contributes to the development of these disorders. However, the factors determining the exposure of farmers to particles that can enter the lower bronchial tract and interact with it, i.e. the thoracic fraction of the inhalable dust, remain to be identified. We therefore measured the exposure of dairy farmers to thoracic organic dust and identified the farm features and tasks that increased exposure. We measured thoracic particles (n = 110) and farm characteristics and occupational tasks in 29 Brittany dairy farms. The mean (GM) (geometric standard deviation, GSD) concentration of thoracic dust in air inhaled by farmers was 0.24 mg/m{sup 3} (2.8) and the concentrations of endotoxins, Gram-positive bacteria and fungi in the thoracic fraction were 128 EU/m{sup 3} (4.0), 960 CFU/m{sup 3} (6.3) and 690 CFU/m{sup 3} (5.4), respectively. Model-based estimates of the association between exposure, farm features and tasks indicated that manual grain and feed handling and mechanical bedding spreading significantly increased exposure to thoracic dust, endotoxins, bacteria and fungi. Exposure to bacteria and fungi was reduced by cowsheds divided into cubicles, whereas using automatic muck scrappers in alleyway and automatic milking tended to increase exposure to bacteria and endotoxins. Finally, exposure to endotoxin and fungi were reduced by warmer farm buildings and well-ventilated buildings having walls with large openings. In conclusions, major occupational tasks and specific farm features determine the exposure of Breton dairy farmers to thoracic organic dust.

54 ENVIRONMENTAL SCIENCES↗

Decarbonizing residential buildings in the United States: A comparative analysis of households and construction professionals

In this study, we present a comparative analysis of surveys distributed to home occupants and construction professionals in the U.S., focused on energy upgrades and electrification retrofits that support residential building decarbonization. The surveys were executed by separate research groups and combined for this study. The study examines the decision-making, sentiments, perceptions, experiences, and practices of both groups by analyzing data from three separate surveys. These surveys assess technologies, attitudes, awareness, motivations, barriers, and opportunities related to energy retrofits and electrification. The analysis highlights key differences in the perceptions and behaviors of households and construction professionals, revealing substantial barriers to achieving decarbonization goals. For example, households cite climate change and sustainability as key motivators for pursuing energy retrofits (89%), while construction industry professionals view these themes as less important for their clients (44%). This suggests an opportunity for the construction industry to align its messaging with the values that households prioritize, helping to advance residential decarbonization. Overall, the study identifies challenges faced by both groups, factors influencing the adoption of energy-efficient practices, and inconsistencies between occupant and construction industry professionals' views. These insights contribute to the development of targeted strategies and policies to accelerate the decarbonization of residential buildings in the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Si/Al ratio of ZSM-5 support on structure and activity of Mo species in methane dehydroaromatization

The effect of the Si/Al ratio of the ZSM-5 support on the structure and activity of Mo/HZSM-5 catalysts in methane dehydroaromatization (MDA) was studied. ZSM-5 (with Si/Al = 15, 25, and 40) supported Mo oxide catalysts (MoOx/ZSM-5) with 3 and 10 wt% Mo loading were prepared by incipient wetness impregnation followed by calcination in air at 500 °C. The as-prepared catalysts were activated by temperature programmed reduction in hydrogen in order to maximize Mo dispersion. To understand the structure-activity relationship, the fresh and spent samples were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), N2 adsorption isotherms, Scanning Transmission Electron Microscopy with Energy Dispersive X-Ray Spectroscopy (STEM-EDS), X-ray absorption spectroscopy (EXAFS and XANES), thermogravimetric analysis (TGA), and Raman spectroscopy. The results show that the Si/Al ratio does not influence the the local structure around the Mo centers. It does however affect the number of available Brønsted acid sites in the support and the amount of Mo species entering the zeolite channels. A lower Si/Al ratio and higher Mo loading resulted in a higher Mo occupation within the zeolite channels. The higher channel occupation directly correlated with higher benzene selectivity and yield, as well as a lower catalyst deactivation rate.