Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Zero Valent Iron for Reductive Removal of Technetium-99 from Aqueous Sulfate Solutions - 20347

This research investigates the reductive removal of technetium-99 ({sup 99}Tc) by zero valent iron (ZVI) from low activity waste (LAW) off-gas condensate simulant as a secondary treatment after recovery from vitrification planned at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Due to its high volatility, only a fraction of Tc{sup (VII)} will be incorporated into glass waste forms. Volatilized Tc will be captured by an off-gas treatment system with current plans to recycle off-gas condensate back to the vitrification facility. The scheme with off-gas recycling will increase Tc loading in the glass waste, but will also increase the concentrations of sulfate, halides, and other problematic constituents impeding overall LAW processing and increasing volume of the glass product. This study focuses on Tc{sup (VII)} removal by ZVI as a feasible pathway to minimize off-gas condensate recycling, which may result in a reduction in the volumes of LAW waste to be immobilized and subsequent cost savings. ZVI is an established treatment agent for redox-active contaminants such as trichloroethylene, nitrate, arsenic, chromium, phenol, and others. It is a commercially available and cost-effective material. Our previous experiments showed that ZVI is very efficient for the reductive removal of {sup 99}Tc. In this work we studied ZVI oxidation under aerobic conditions at pH 7 with 0.1 M Na{sub 2}SO{sub 4} solution (ionic strength, IS, 0.3 M) in the presence and absence of {sup 99}Tc. The concentration of {sup 99}Tc and the changes in pH, dissolved oxygen (DO), and oxidation-reduction potential (ORP) of the simulated solutions were monitored over 8 days. The formation of iron oxide phases was probed by X-ray diffraction (XRD). Obtained results suggest that ZVI contact time with {sup 99}Tc containing solutions for 6 hours resulted in nearly complete removal of {sup 99}Tc from the aqueous phase. XRD analysis showed that the oxidation of ZVI is rapid with formation of magnetite (Fe{sub 3}O{sub 4}) with minor percentage of goethite and maghemite. This work is a part of a larger set of studies investigating the feasibility of {sup 99}Tc reductive removal from the LAW off-gas condensate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crystalline Silicotitanate Batch Contact Testing with Ba, Ca, Pb, and Sr

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank Side Cesium Removal system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. Processing of actual tank waste supernate showed effectively complete uptake of Sr and Ba by CST and significant uptake of Ca. Further, Campbell et al. (2019) analyzed CST post-column testing and found significant (>1E-2 mmoles/g) uptake of Ca and Pb along with some Ba, Cd, Fe, Sr, and U. This led to concern that selected metals, particularly the +2 cations, Ca, Sr, Ba, and Pb may be consuming Cs exchange sites and possibly reducing CST capacity for Cs. Exchange of +2 cations was assumed to be associated with the M(OH) + species for the metal (M) ion in the caustic solution. A series of batch contact testing was conducted to evaluate the exchange behavior of Ba, Ca, Pb, and Sr onto CST. The Cs exchange behavior was also tested as a benchmark for direct comparisons. The CST was provided in the sodium form by Honeywell UOP, as IONSIV TM R9140-B, Lot 2002009604, 18 x 50 mesh. A <30-mesh aliquot was collected to match the sieve fraction expected for use in upcoming small column test configurations. Kinetic exchange rate and isotherms were measured at metal concentrations benchmarked from the AP-107 tank waste feed composition and as limited by the metal solubility in the alkaline solution. Two simplified matrices were tested: 1) 1.0 M NaOH/4.6 M NaNO 3 and 2) 0.1 M NaOH/5.5 M NaNO 3 ; these matrices represented the expected 5.6 M Na concentration of process feed and served to address the hydroxide concentration effect on exchange behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Autonomous Control of Space Nuclear Reactors

Nuclear reactors to support future robotic and manned missions impose new and innovative technological requirements for their control and protection instrumentation. Long-duration surface missions necessitate reliable autonomous operation, and manned missions impose added requirements for failsafe reactor protection. There is a need for an advanced instrumentation and control system for space-nuclear reactors that addresses both aspects of autonomous operation and safety. The Reactor Instrumentation and Control System (RICS) consists of two functionally independent systems: the Reactor Protection System (RPS) and the Supervision and Control System (SCS). Through these two systems, the RICS both supervises and controls a nuclear reactor during normal operational states, as well as monitors the operation of the reactor and, upon sensing a system anomaly, automatically takes the appropriate actions to prevent an unsafe or potentially unsafe condition from occurring. The RPS encompasses all electrical and mechanical devices and circuitry, from sensors to actuation device output terminals. The SCS contains a comprehensive data acquisition system to measure continuously different groups of variables consisting of primary measurement elements, transmitters, or conditioning modules. These reactor control variables can be categorized into two groups: those directly related to the behavior of the core (known as nuclear variables) and those related to secondary systems (known as process variables). Reliable closed-loop reactor control is achieved by processing the acquired variables and actuating the appropriate device drivers to maintain the reactor in a safe operating state. The SCS must prevent a deviation from the reactor nominal conditions by managing limitation functions in order to avoid RPS actions. The RICS has four identical redundancies that comply with physical separation, electrical isolation, and functional independence. This architecture complies with the safety requirements of a nuclear reactor and provides high availability to the host system. The RICS is intended to interface with a host computer (the computer of the spacecraft where the reactor is mounted). The RICS leverages the safety features inherent in Earth-based reactors and also integrates the wide range neutron detector (WRND). A neutron detector provides the input that allows the RICS to do its job. The RICS is based on proven technology currently in use at a nuclear research facility. In its most basic form, the RICS is a ruggedized, compact data-acquisition and control system that could be adapted to support a wide variety of harsh environments. As such, the RICS could be a useful instrument outside the scope of a nuclear reactor, including military applications where failsafe data acquisition and control is required with stringent size, weight, and power constraints.

Merk, John↗

Small to Full Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

The U.S. Department of Energy’s (DOE) Hanford Site houses 56 million gallons of high-level radioactive waste generated from plutonium production from 1944 to 1988. The supernatant waste, currently stored in underground tanks, is intended to be vitrified following filtration and 137 Cs removal at the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Vitrification Facility. The WTP Pretreatment Facility will not be operational for several years. The Tank Side Cesium Removal (TSCR) system is a technology demonstration that will remove cesium from tank waste supernate to support directly feeding LAW to the vitrification facility. The 137 Cs removal is important to meet the WTP LAW contract specification and ultimately for creating a contact-handled waste form. The waste acceptance criteria (WAC) limit for the WTP LAW Facility is <3.18E-5 Ci 137 Cs per mole Na. The TSCR system is skid mounted and employs two key technologies: dead end filtration for solids removal and ion exchange (IX) for cesium removal. Filtration is necessary to protect the functionality of the IX columns. The IX process utilizes sodium form crystalline silicotitanate (CST) IX media produced by UOP Honeywell, LLC (Des Plaines, IL) under the product name IONSIV R9140-B, 18 x 50 mesh, in a lead-lag-polish column configuration. Each column contains a CST bed height of 92 inches and a volume of approximately 157 gallons of CST IX media. The full-scale TSCR operation will run at a residence time of 1.9 bed volumes (BV)/h, which results in a superficial velocity of 7.3 cm/min and a flowrate of ~5 gal/min. Column testing at small (2.5% of the full bed height), medium (12% of the full bed height), and full-height scales has been previously conducted to evaluate process variables and scale up performance of Cs exchange onto the CST. Cesium load performances from various sieve cuts at the small scale indicated that a 30-mesh sieve cut be tested to determine if it better reflects the 12% and full-height column performances at the small scale. Two process flowrates were tested in the small-column configuration with <30-mesh CST and simulant solutions. These tests were compared to full-height column tests at the same residence times to assess CST particle size effect on column scaling. Table S.1 summarizes the observed column performance determined for the two flowrates juxtaposed to the previous work with 5.6 M Na simulant at higher scales (used as benchmarks). The WAC breakthroughs between the small and full-height tests at 1.3 BV/h differed by ~59 BVs. The WAC breakthroughs for small, medium, and full-height tests at 1.8 BV/h were consistent at 240 BVs. The 50% Cs breakthroughs were nominally equivalent for all column tests. The common transition zones and onsets of Cs breakthrough at the 1.8 BV/h tests indicated that the Cs mass transfers were equivalent and thus the <30-mesh CST Cs load performance at the small scale successfully modeled that of the full-height system. It is recommended that the <30-mesh CST be used in subsequent 10-mL CST bed tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation of Glycolate in the Defense Waste Processing Facility (DWPF) Recycle Collection Tank - 20305

The Savannah River Site's Defense Waste Processing Facility (DWPF) operations are being upgraded with the introduction of the Nitric-Glycolic Flowsheet. Glycolic acid has been shown superior to formic acid as the reducing acid used during chemical processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology and 3) adjustment of melter oxidation/reduction potential. Further, the potential for catalytic hydrogen generation in DWPF processing is virtually eliminated. DWPF process condensates are collected and returned to the SRS Concentration, Storage and Transfer Facilities (CSTF). The Recycle Collection Tank (RCT) collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle may contain a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, chemical oxidation within the RCT has been investigated as an option for mitigating the transfer of glycolate. Sodium permanganate has been down-selected as the best option for oxidation of glycolate. Testing was performed using both 2-L and 22-L reactors (16,800:1 and 1,530:1 scale by volume) with non-radioactive waste simulants to approximate the expected RCT compositions. RCT simulants were evaluated at various process pH and temperature conditions. Also, RCT operations, namely the sequence of addition of corrosion inhibitors (NaOH and NaNO{sub 2}) versus a permanganate strike, were evaluated. Glycolate was introduced via a sludge simulant to mimic both expected entrainment and abnormal process foam-over conditions - the range being between 68 and 5100 mg/kg glycolate. Glycolate destruction was monitored by ion chromatography (IC). The corresponding manganese behavior was monitored in real-time using in situ ultraviolet-visible (UV-Vis) spectroscopy. RCT glycolate content can be reduced to below the IC detection limit within 90 minutes for all concentrations investigated. Ion Chromatography analysis revealed that under alkaline conditions, glycolate is primarily oxidized to oxalate with no significant formation of CO{sub 2} or carbonate, and nitrite is not oxidized to nitrate. Initially, complete oxidation of organics species and nitrite was assumed. Determination of the mechanistic chemical reaction has allowed the required amount of permanganate to be more accurately predicted and the total addition to be significantly reduced. UV-Vis measurements reveal that permanganate (Mn{sup 7+}) is reduced to manganate (Mn{sup 6+}) in the RCT. The oxidant stoichiometry is defined by using the initial permanganate to glycolate (P/G) molar ratio. At low initial glycolate concentration (68 and 140 mg/kg), the minimum required initial permanganate to glycolate (P/G) molar ratio was found to be 5-6. With high initial glycolate concentrations (5100 mg/kg) a lower (P/G) molar ratio of ∼2.5 was needed. The final portion of this effort supporting the nitric/glycolic flowsheet will be to test actual (fully radioactive) RCT samples as per the above simulant tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Literature Review on Next Generation Solvent Isopar ® L Vapor Pressure Curve and the Partitioning of its Modifier and Extractant

The Next Generation Solvent (NGS) is set to replace the Original Caustic Side Solvent Extractant (CSSX) at the Salt Waste Processing Facility (SWPF). The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC), formerly Savannah River Remediation (SRR), to perform a literature review on the following topics to address flammability concerns with the current solvent: Isopar ® L vapor pressure curve for NGS, partitioning ratio for the extractant MaxCalix and the modifier Cs-7SB, and high cesium concentration impacts on NGS radiolysis and potential solvent degradation rates in high cesium concentrations. The following conclusions and recommendations are made based on previous experimental work and literature: (1) Current SWPF flammable gas generation calculations use an Isopar ® L vapor pressure curve based on experimental testing with the Original CSSX solvent. No such testing to date has been performed with NGS. It is suggested that the decrease in Cs-7SB concentration for NGS compared to the Original CSSX solvent would lead to a slightly higher vapor pressure at all temperatures in SWPF vessels. A bounding NGS vapor pressure curve has been provided; it is recommended to see if these values would challenge current flammability controls and to perform testing if needed.(2) The partitioning ratio for Cs-7SB is known in the Original CSSX solvent with dilute nitric acid and caustic solutions. No tests could be found for the partitioning of Cs-7SB to dilute boric acid solutions; however, a similar partitioning ratio is expected. Due to the lipophilic alkyl chains on MaxCalix, it is expected to be even less soluble than BOBCalixC6 in the aqueous phase and should not be considered a significant contributor to the f organic term. Additionally, the reaction rate of N,N’,N’’-Tris(3,7-dimethyloctyl)guanidine (TiDG) or its degradation products with a hydrogen radical should be estimated/determined if they are found to be significant contributors to the f organic term. (3) NGS is expected to see much higher Cs concentrations at SWPF in comparison to its use at the Modular CSSX Unit (MCU). These higher Cs concentrations could influence radiolytic degradation rates of the solvent. NGS appears to be fairly stable to radiolytic degradation based on previous testing and its use at MCU. However, there has not been radiolytic flammable gas generation testing with NGS to date. There is a risk that the continued use of G-values obtained for flammable gases produced from the irradiation of the Original CSSX solvent is not bounding for NGS, but this is considered a very low risk due to the similarities in the composition of the solvents, as well as the conservatisms in the experimental design of the Original CSSX testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Microbial Communities as Indicators of Microbially Induced Corrosion Potential in Stainless Steel Piping

The 200 West Area Pump-and-Treat (200W P&T) facility is part of the final remedy decision for the 200 ZP-1 Operable Unit (OU) and is the interim remedial action for 200-UP-1 OU at the Hanford Site. The facility also treats water from other sources across the site, including 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. The facility originally operated a biological treatment process for nitrate that resulted in systemic biofouling and loss of injection well capacity, requiring frequent and costly well rehabilitation. Biofouling has also contributed to corrosion of welds and pitting of stainless-steel piping at the facility. The biological treatment for nitrate was suspended at the end of 2019 calendar year to eliminate negative impacts from biological treatments which improve facility operations and treatment of carbon tetrachloride. Evaluation of the 200W P&T facility’s response to operational improvements, specifically the suspension of the biological treatment, provides information on the potential for continued microbially induced corrosion (MIC). To this end, historical data sets (2015-2017) were compared with molecular biological analyses of 200W P&T water samples from 2018-2020 to quantify trends in total microbial biomass and specific microbial indicator species (iron, sulfate, nitrate, and manganese reducing bacteria) known to cause and enhance metal corrosion. Results showed unequivocal reductions (in excess of 90%) in all microbiological indicators measured following the suspension of the biological treatment. Although abundance measurements for all corrosive MIC populations initially declined after removal of the treatment system, nitrate-reducing bacteria (nirK) and sulfate-reducing bacteria remain highly abundant in the system, an order of magnitude higher than the number of cells present prior to the removal of the biological treatment system [5.14e (1.4) cells/L, vs. 1.14e (0.07) cells/L, reported as average (±SD) for n=3]. In addition, there was an unexpected inflection point in 2019 where all microbial indicators increased unexpectedly in abundance in 2020 by as much as two orders of magnitude compared to 2019 samples. Given the limited number of water samples available for this analysis, the cause of the increase in microbial indicators post-biological treatment has not yet been determined. Systematic sampling of the facility for continued monitoring is recommended so that the responses of MIC populations can be evaluated to ensure that further corrosion is avoided, allowing the 200W P&T facility to operate safely and efficiently at design capacity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Summary Report for the Remote-Handled Low-Level Waste Disposal Facility—FY2021

This Fiscal Year (FY) 2021 annual summary report (ASR) documents the continued adequacy of the performance assessment (PA), the composite analysis (CA) and associated operating disposal-authorization statement (ODAS) technical basis documents for the Remote Handled (RH) Low-Level Waste (LLW) Disposal Facility at Idaho National Laboratory. Annual review of the adequacy of the PA and CA for the RHLLW Disposal Facility ensures that conclusions of the analyses remain valid in accordance with requirements of Department of Energy (DOE) Order 435.1, “Radioactive Waste Management.” In FY 2021, no significant operational changes or other activities occurred that would cause deviation from the assumptions in the PA and CA pertaining to disposal geometry, verification of waste characteristics, tracking disposal inventories against total limits, facility closure design, or institutional controls. Sixteen total waste-canister shipments were received at the RHLLW Disposal Facility, and 16 total waste canisters were emplaced.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY 2020 Radionuclide Migration Project Status

The Waste Management Project provides safe, compliant, and cost-effective waste management services for the Hanford Site and the U.S. Department of Energy (DOE) complex. Part of these services includes safe disposal of low-level waste and mixed low-level waste at the Hanford Low-Level Waste Burial Grounds in accordance with the requirements of DOE Order 435.1, Radioactive Waste Management. To partially satisfy these requirements, performance assessment analyses were completed and approved. DOE Order 435.1 also requires continuing data collection to increase confidence in the critical assumptions used in these analyses to characterize the operational features of the disposal facility that are relied on to satisfy the performance objectives identified in the order.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Summary Report for the Remote-Handled Low-Level Waste Disposal Facility—FY 2020

This Fiscal Year (FY) 2020 annual summary report documents the continued adequacy of the performance assessment (PA), the composite analysis (CA) and associated operating disposal-authorization statement (ODAS) technical basis documents for the Remote Handled (RH) Low-Level Waste (LLW) Disposal Facility at Idaho National Laboratory. Annual review of the adequacy of the PA and CA for the RHLLW Disposal Facility ensures that conclusions of the analyses remain valid in accordance with requirements of Department of Energy (DOE) Order 435.1 Change 1, “Radioactive Waste Management.” In FY 2020, no significant operational changes or other activities occurred that would cause deviation from the assumptions in the PA and CA pertaining to disposal geometry, verification of waste characteristics, tracking disposal inventories against total limits, facility closure design, or institutional controls. Fifteen total waste-canister shipments were received at the RHLLW Disposal Facility, and 15 total waste canisters were emplaced.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Process Emissions during Thermal Cutting of Clad Metals from the Nuclear Sector - 20183

Typically, reactor pressure vessels as well as steam generators comprising low alloyed steel with a cladding of stainless steel. Recently the permissible values for Cr (VI) in the air of the working areas have been reduced in Germany from 100 μg/m{sup 3} to 1 μg/m{sup 3} air. This results in the danger that even with low-alloy steel with claddings these limit values would be exceeded when using flame cutting technologies. In order to ensure compliance with the permissible limit values, exhaust gas systems with gas cleaning measures are provided. The process emission test shall replace the assumptions required for the design of these systems with measured values. NUKEM Technologies Engineering Services GmbH (NUKEM) has chosen autogenous flame cutting as an example of a thermal cutting system for process emission testing, as there are no proven values in the literature for the Cr (VI) and NiOx emissions produced. The autogenous flame cutting can be used for a variety of cutting tasks within decommissioning projects. In order to simulate the material to be cut, mock ups were generated and cut from information about the material specification for the reactor pressure vessel from existing nuclear power plants including possible claddings. The cutting length needed for analysis in the test will be maximum 100 mm. The airborne emissions from the thermal cutting process will be captured and analyzed as follows: - Dust emission: The generated particles will be collected by a hood equipped with strong suction device and suitable filter elements. The resulting filter is gravimetrically measured before and after the tests. - Particle Size Distribution: The airborne particle size distribution measurement will result in figures for the size and number of particles arising from the thermal cutting process. - Gas Analysis: The gas analysis enables the determination of e.g. CO{sub 2}, CO, O{sub 3}, NO, NO{sub 2}. - Cr (VI) and NiOx Analysis: For the Cr (VI) and NiOx analysis, samples of the filter residue will be taken. As a result Cr (VI) in relation to total Cr as well as the Ni content will be determined by ICP-optically emission spectroscopy and put in relation to the total dust amount. The process emissions test itself as well as the necessary gas analyses and spectroscopic analyses were carried out at the Institute of Materials Science (IW) of Leibniz Universitaet Hannover (LUH). The results of the process emission tests are used to confirm the design of the gas cleaning systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RANT Waste Container Receipt, Inspection, and Transfer

This procedure provides instructions for the receipt, inspection, and transfer of transuranic (TRU) waste containers within the Radioassay and Nondestructive Testing (RANT) Facility. Performance of this procedure meets the Surveillance Requirements (SRs) 4.1.1, 4.1.2, 4.1.3, 4.2.1, 4.2.2, 4.2.3 and 4.2.4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Baseline Monitoring Data for the Remote-Handled Low-Level Waste Disposal Facility at Idaho National Laboratory

The purpose of this document is to summarize environmental monitoring data collected at the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility during the first four years of facility operations (FY 2019 through FY 2022). This summary provides a “baseline” condition for the facility, which can be used to distinguish contaminant releases from the RHLLW Disposal Facility from pre existing contamination as well as potential future releases from other sources (i.e., upgradient aquifer sources), as specified in the facility monitoring plan. Sufficient data has been collected over the first four years of operation of the RHLLW Disposal Facility to establish baseline conditions for future compliance monitoring of aquifer wells and performance monitoring of vadose zone lysimeters. Except for seven elevated tritium measurements from lysimeter HFEF-South believed to have been impacted by waste disposals, all data was deemed appropriate for establishing baseline concentrations. Monitoring of the aquifer detected indicator analytes gross alpha and gross beta and target analytes tritium and C-14. There were a few C-14 detections prior to an increase in the required detection level (RDL) after the first round of sampling. I-129 and Tc-99 were not detected above RDLs in aquifer samples. Lysimeter samples detected indicator analytes gross alpha and gross beta and target analyte tritium. Target analytes C-14, I-129, and Tc-99 were not detected above RDLs in lysimeter samples. Except for tritium, baseline concentrations of indicator and target analytes measured during the first four years of RHLLW facility operations are expected to represent conditions through the expected 20 year operating period of the facility. Elevated tritium in the aquifer, a result of past discharges of tritium at upgradient facilities, showed a decline over the first four years of operations, and levels are expected to continue to decline with time as a result of dilution and decay. Current tritium levels in lysimeter samples may be elevated due to tritium in the water applied during construction and infiltration testing of the facility. As a result, tritium concentrations in lysimeters may decline with time as a result of dilution and decay. Statistical measures (i.e., mean, standard deviation, and 99% upper confidence level [UCL]) were calculated for all detected analytes using the four years of concentration data. These measures will be used to evaluate future monitoring results and to demonstrate the facility is performing, or not performing, as established in the facility performance assessment (PA). Future monitoring results will also be combined with the baseline data in this report to further establish temporal trends and natural variability in the measurements. Based on the data collected during the baseline period, it is recommended the gross alpha action level for performance monitoring increase from 10 to 20 pCi/L due to several baseline measurements exceeding the preliminary action level of 10. An action level of 20 pCi/L is slightly greater than the 99% UCL, is protective of the aquifer, and would reduce unnecessary sampling. It is also recommended that tritium be added to the lysimeter analyte list for post-baseline period monitoring. Tritium, while not a dose concern, is a good tracer that can provide valuable information on water flow in and around the RHLLW Disposal Facility. Recommendations for a tritium action level are provided if considered necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Mixed Waste Treatment Project Overcomes Challenges to Complete Treatment of Debris Waste - 20616

The Advanced Mixed Waste Treatment Project (AMWTP), operated by Fluor Idaho for the Department of Energy Idaho Operations Office, completed the last of its debris waste treatment in the fall of 2019. Concluding that work-scope was certainly not without its challenges. Fluor Idaho and its employees had to adapt to treating extremely challenging waste types, such as high-fissile gram materials and potentially pyrophoric and reactive wastes coming down the stretch. It also had to complete the sizing of large waste boxes from Mound Laboratories in inner-contamination enclosures designed to capture the extremely fine, 'flighty' plutonium-238 in its high-efficiency particulate air filters. Very few waste treatment facilities in the DOE Complex have completed their missions. In fact, most large-scale waste treatment facilities are still under construction with many months or years remaining before 'hot operations' begin. AMWTP is unique because it functioned as a 'one-stop shop.' Transuranic and low-level waste characterization, treatment, certification, and shipping all occurred there. AMWTP concluded the most challenging part of its mission and will continue to ship material out of the state of Idaho for the next decade. This paper will provide a background of the AMWTP mission, and the adaptations to its operating permit, equipment, or treatment processes to address challenging waste types. AMWTP will leave behind a legacy of being one of the most successful waste treatment facilities in the history of the DOE Complex. The facility was well-conceived, well-constructed, and well-executed; it was done right from start to finish. During the course of its waste treatment mission, the facility was required to adapt to changing conditions by treating extremely challenging waste types. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Azimuthal Drive Asymmetry in Inertial Confinement Fusion Implosions on the National Ignition Facility

Data from nuclear diagnostics present correlated signatures of azimuthal implosion asymmetry in recent indirect-drive inertial confinement fusion (ICF) implosion campaigns performed at the National Ignition Facility (NIF). The mean hot-spot velocity, inferred from the Doppler shift of 14 MeV neutrons produced by deuterium-tritium (DT) fusion, is systematically directed toward one azimuthal half of the NIF target chamber, centered on φ ≈ 7 0 ° . Areal density ( ρ R ) asymmetry of the converged DT fuel, inferred from nuclear activation diagnostics, presents a minimum ρ R in the same direction as the hot-spot velocity and with Δ ρ R amplitude correlated with velocity magnitude. These two correlated observations, which are seen in all recent campaigns with cryogenic layers of DT fuel, are an understood signature of asymmetry in the fuel convergence, implying a systematic azimuthal drive asymmetry across a wide range of shot and target configurations. The direction of the implied radiation asymmetry is observed to cluster toward the hohlraum diagnostic windows. Furthermore, this low-mode asymmetry degrades hot-spot conditions at peak convergence and limits implosion performance and yield

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Annual Summary Report for the Remote-Handled Low-Level Waste Disposal Facility—FY 2022

This Fiscal Year (FY) 2022 annual summary report (ASR) documents the continued adequacy of the performance assessment (PA), the composite analysis (CA) and associated operating disposal-authorization statement (ODAS) technical-basis documents for the Remote-Handled (RH) Low-Level Waste (LLW) Disposal Facility at Idaho National Laboratory. Annual review of the adequacy of the PA and CA for the RHLLW Disposal Facility ensures that conclusions of the analyses remain valid in accordance with requirements of Department of Energy (DOE) Order 435.1, “Radioactive Waste Management.” In FY 2022, no significant operational changes or other activities occurred that would cause deviation from the assumptions in the PA and CA pertaining to disposal geometry, verification of waste characteristics, tracking disposal inventories against total limits, facility-closure design, or institutional controls. Fifteen waste canister shipments were received at the RHLLW Disposal Facility, and 15 waste canisters were emplaced in disposal vaults.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Influence of Alkalinity on the Uptake of Cs{sup +} and Sr{sup 2+} by Cation-substituted Natisites in Sodium-bearing Conditions - 20336

The titanosilicate natisite (Na{sub 2}TiSiO{sub 5}) is a kinetic phase of the mineral sitinakite (Na{sub 2}Ti{sub 2}O{sub 3}SiO{sub 4}.2H{sub 2}O), which is a reference material in the removal of Cs and Sr from radioactive high-level waste. Natisite is disregarded in the literature as a candidate sorbent for Cs and Sr, despite being more thermally stable than sitinakite, which is a critical property for this application. Replacing portion of the Ti in natisite by other metals is believed to enhance natisite sorption properties. In nuclear waste remediation, Cs and Sr are contained in high-salinity liquid wastes that can either be highly acidic or alkaline. In the present study, Al-, Sn-, and Zr-natisites were synthesized, and compared to pure natisite and sitinakite in batch experiments. Five concentrations of NaOH and NaNO{sub 3} (i.e. source of Na{sup +}) mimicking conditions of high alkalinity, and competing Na{sup +} ions, respectively, were evaluated. Sorption results demonstrate that sitinakite is generally more effective than all four natisites in removing Cs and Sr. However, sitinakite uptake mechanism seems to deteriorate at increasing concentrations of base and Na{sup +}. Although less selective than sitinakite, all natisite sorbents provided a less dramatic decline in Cs and Sr uptake through increasing molarities. Overall, there was an improvement in the sorption of Cs and Sr by the metal-substituted materials over natisite and, in neither of the testing solutions, natisite outperformed its substituted variants. In highly alkaline solutions, Sn- and Zr-Natisite provided for exceptional removal for Sr, removing more than twice the amount sorbed by sitinakite at 0.1 M NaOH. The results obtained for Sr uptake by all four natisite materials in alkaline solutions are promising, especially considering the highly alkaline nature of wastes from the nuclear industry. Future studies should investigate the sorption mechanisms responsible for natisite selectivity for Sr at high pH. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First look at neutron emission shape characteristics of ignition hotspots at the National Ignition Facility (invited)

The nuclear imaging system has been capturing neutron images of inertial confinement fusion (ICF) driven implosions for over a decade at the National Ignition Facility. This imaging system has evolved from one to three nearly orthogonal lines-of-sight, allowing for the study of three-dimensional shape characteristics of ignition shots. Limited-view tomography algorithms help visualize the burning hotspot in 3D and assess neutron source geometry using Legendre mode parameters. With its neutron, gamma-ray, and x-ray image reconstruction capabilities, NIS has provided critical insight into mechanisms that have limited implosion performance, such as fill tube diameter for ignition-type targets. This comprehensive diagnostic suite opens a window into the shape characteristics of ignition shots and how symmetry affects ICF implosion performance. In more recent ignition shots, neutron yields have visibly increased. Analyzing the shape and size of the reconstructed neutron source has shown an expansion of the burn volume, which is indicative of more efficient alpha heating during the implosion process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗