Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Data Sensitivities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Global tuning of hadronic interaction models with accelerator-based and astroparticle data

In high-energy and astroparticle physics, event generators play an essential role, even in the simplest data analyses. As analysis techniques become more sophisticated, e.g. based on deep neural networks, their correct description of the observed event characteristics becomes even more important. Physical processes occurring in hadronic collisions are simulated within a Monte Carlo framework. A major challenge is the modeling of hadron dynamics at low momentum transfer, which includes the initial and final phases of every hadronic collision. QCD-inspired phenomenological models used for these phases cannot guarantee completeness or correctness over the full phase space. These models usually include parameters which must be tuned to suitable experimental data. Until now, event generators have been developed and tuned mainly on the basis of data from high-energy physics experiments at accelerators. The wealth of data available from the latest generation of astroparticle experiments has not yet been fully exploited, and in many cases is not satisfactorily described. Both kinds of data sets are complementary as astroparticle experiments provide sensitivity especially to hadrons produced nearly parallel to the collision axis and cover center-of-mass energies up to several hundred TeV, well beyond those reached at colliders so far. In this report, we provide an overview of state-of-the-art event generators and their tuning, including the most relevant inputs from high-energy accelerator and astroparticle experiments. We present a road map that shows, for the first time, how the unified tuning of event generators with accelerator-based and astroparticle data can be performed.

Albrecht, J. [Ruhr U., Bochum, RAPP Ctr.; Ruhr U.,↗

Search for neutrinoless β-plus-EC decay of 120 Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale cryogenic experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than 130 Te. In this work we describe a search for neutrinoless positron-emitting electron capture (β + EC ) decay in 120 Te with a total TeO 2 exposure of 355.7 kg yr, corresponding to 0.2405 kg yr of 120 Te. Albeit 0νββ with two final-state electrons represents the most promising channel, the emission of a positron and two 511-keV γ 's make 0νβ + EC decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of 3.4 × 10 22 yr at 90% credibility interval (C.I.). After unblinding we find no evidence of 0νβ + EC signal and set a 90% C.I. Bayesian lower limit of 2.9 × 10 22 yr on 120 Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exclusive π 0 p electroproduction off protons in the resonance region at photon virtualities 0.4 GeV 2 ≤ Q 2 ≤ 1 GeV 2

The limited electroproduction process e p → e ' p ' π 0 was measured in the range of photon virtualities Q 2 = 0.4 – 1.0 GeV 2 and the invariant mass range of the p π 0 system of W = 1.1 – 1.8 GeV. These kinematics are covered in exclusive π 0 electroproduction off the proton with nearly complete angular coverage in the p π 0 center-of-mass system and with high statistical accuracy. Nearly 36 000 cross-section points were measured, and the structure functions σ T + ε σ L , σ L T , and σ T T , were extracted via fitting the φ π 0 dependence of the cross section. A Legendre polynomial expansion analysis demonstrates the sensitivity of our data to high-lying N * and Δ * resonances with M > 1.6 GeV. As part of a broad effort to determine the electrocouplings of the N * and Δ * resonances using both single- and double-pion electroproduction, this dataset is key for the reliable extraction of the high-lying resonance electrocouplings from the combined isospin analysis of the N π and π + π - p channels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Natural Resources Assessment for the SNS Second Target Station, Oak Ridge, Tennessee

The US Department of Energy’s Oak Ridge National Laboratory (ORNL) is a leading institution in advanced materials, supercomputing, neutrons, and nuclear science. As a research laboratory managed by UT-Battelle, LLC for DOE, ORNL has national priorities in energy, security, and scientific discovery that necessitate facility improvements and expansions. DOE is also committed to environmental stewardship. The laboratory is located on the ~32,000-acre Oak Ridge Reservation (ORR), much of which is categorized as a National Environmental Research Park and a state Wildlife Management Area. DOE works with the Tennessee Wildlife Resources Agency (TWRA), Tennessee Department of Environment and Conservation (TDEC), US Fish and Wildlife Service (USFWS), US Department of Agriculture, and other agencies to serve as an effective steward of the ORR. Accordingly, project managers must conform to environmental regulations, agreements, and policies at the federal, state, and institutional levels. Per 40 CFR (Code of Federal Regulations) 1508.14, potential effects on research and science education on the National Environmental Research Park represent potential impacts of federal actions. Moreover, federal actions that affect the quantity and quality of hunting opportunities and deer reduction harvest on the Oak Ridge Wildlife Management Area must be considered whenever other aspects of the human environment (as defined by NEPA) are affected. The Spallation Neutron Source (SNS) is a premiere facility at ORNL that provides advanced capabilities in neutron scattering to promote new discoveries and research opportunities in material sciences, physics, chemistry, biological sciences, and others. A conceptual design for a Second Target Station (STS) has been in consideration for several years. The STS is intended to complement and enhance existing ORNL capabilities, notably research and exploration of complex materials. The proposed STS will involve development of existing natural areas on the ORR, which might contain sensitive resources that require mitigation or avoidance in accordance with existing policies and regulation. This report summarizes current knowledge of natural and cultural resources within the STS project area. At the time of this report, the proposed STS project consisted of an operations area comprising 55.4 acres (22.4 ha) and a total review area for potential construction comprising ~224 acres (90.6 ha). The review area is located primarily within forested natural areas of the ORR with minor development in the form of power-line rights-of-way and secondary/graveled roads (Figure 1). The primary goal was to evaluate potential effects on sensitive resources that might result from development of the STS. In addition to onthe-ground surveys during summer 2009 and fall 2019 to summer 2020 by ORNL Natural Resources Management Program and Aquatic Ecology Group staff, this report makes use of historical (pre-1995) and contemporary (1995 to present) data from additional confirmed sources (e.g., TDEC). Likewise, forest conditions were compiled primarily from a 2013 forest inventory effort for Forest Management Compartment 17 and supplemented with limited ground observations in 2019. The individuals who obtained and compiled the data that are presented here are familiar with and routinely assess sensitive resources on the ORR.

54 ENVIRONMENTAL SCIENCES↗

Signs of nonmonotonic finite-volume corrections to 𝑔 𝐴

We study finite-volume (FV) corrections to determinations of 𝑔 𝐴 via lattice quantum chromodynamics (QCD) using analytic results and numerical analysis. We observe that 𝑆⁢𝑈⁡(2) heavy Baryon chiral perturbation theory does not provide an unambiguous prediction for the sign of the FV correction, which is not surprising when one also considers large-𝑁 𝑐 constraints on the axial couplings. We further show that nonmonotonic FV corrections are naturally allowed when one considers either including explicit Δ-resonance degrees of freedom or one works to higher orders in the chiral expansion. We investigate the potential impact of these FV corrections with a precision study of 𝑔 𝐴 using models of FV corrections that are monotonic and nonmonotonic. Using lattice QCD data that is approximately at the 1% level of precision, we do not see significant evidence of nonmonotonic corrections. Looking forward to the next phase of lattice QCD calculations, we estimate that calculations that are between the 0.1% and 1% level of precision may be sensitive to these FV artifacts. Finally, we present an update of the CalLat prediction of 𝑔 𝐴 in the isospin limit with subpercent precision, 𝑔$^{QCD}_{𝐴}$ = 1.2674⁢(96).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

White paper on light sterile neutrino searches and related phenomenology

This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of Three Neodymium Atomic Data Sets for Kilonova Modeling

We examine the impact of input neodymium (Nd) atomic data on the light curves and spectra of kilonovae (KNe), probing the sensitivity of kilonova observables to the atomic physics of this important lanthanide element. We use the SuperNu Monte Carlo radiative transfer code, simulating a simple semianalytic 1D kilonova (KN) with a pure Nd atmosphere, fixing the radiative transfer method while using input atomic data generated by three different codes: the LANL suite of atomic physics codes, HULLAC, and Autostructure. We see that the choice of atomic data significantly shapes the resulting light curves and spectra. Peak bolometric luminosities differ by a ratio of nearly 1.5 between HULLAC/Autostructure and LANL data sets. Moreover, we observe significant near- to mid-IR differences in the structure of the spectra. We specifically attribute these differences to the choice of atomic data for neutral Nd I. Many of the results here have been adapted from a presentation at “Radiative Transfer and Atomic Physics of Kilonovae” in Stockholm, 2023. We additionally present a LANL data set with energies calibrated to available values in the NIST Atomic Spectra Database, and demonstrate that this calibration also significantly affects IR spectral structure at late time. The substantial differences in KN observables that arise from tuning the atomic data of just one lanthanide element highlight the special attention that must be paid to atomic physics uncertainties when modeling KNe, from AT2017gfo to beyond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of quark- and gluon-like jet fractions using jet charge in PbPb and pp collisions at 5.02 TeV

The momentum-weighted sum of the electric charges of particles inside a jet, known as jet charge, is sensitive to the electric charge of the particle initiating the parton shower. This paper presents jet charge distributions in $ \sqrt{s_{\mathrm{NN}}} $ = 5.02 TeV lead-lead (PbPb) and proton-proton (pp) collisions recorded with the CMS detector at the LHC. These data correspond to integrated luminosities of 404 μb$^{−1}$ and 27.4 pb$^{−1}$ for PbPb and pp collisions, respectively. Leveraging the sensitivity of the jet charge to fundamental differences in the electric charges of quarks and gluons, the jet charge distributions from simulated events are used as templates to extract the quark- and gluon-like jet fractions from data. The modification of these jet fractions is examined by comparing pp and PbPb data as a function of the overlap of the colliding Pb nuclei (centrality). This measurement tests the color charge dependence of jet energy loss due to interactions with the quark-gluon plasma. No significant modification between different centrality classes and with respect to pp results is observed in the extracted quark- and gluon-like jet fractions.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ( 0νββ ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0νββ decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0νββ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

experimental nuclear physics↗

AugerPrime surface detector electronics

Operating since 2004, the Pierre Auger Observatory has led to major advances in our understanding of the ultra-high-energy cosmic rays. The latest findings have revealed new insights that led to the upgrade of the Observatory, with the primary goal of obtaining information on the primary mass of the most energetic cosmic rays on a shower-by-shower basis. In the framework of the upgrade, called AugerPrime, the 1660 water-Cherenkov detectors of the surface array are equipped with plastic scintillators and radio antennas, allowing us to enhance the composition sensitivity. To accommodate new detectors and to increase experimental capabilities, the electronics is also upgraded. This includes better timing with up-to-date GPS receivers, higher sampling frequency, increased dynamic range, and more powerful local processing of the data. In this paper, the design characteristics of the new electronics and the enhanced dynamic range will be described. The manufacturing and test processes will be outlined and the test results will be discussed. The calibration of the SD detector and various performance parameters obtained from the analysis of the first commissioning data will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conformational Dynamics of Bacteriochlorophyll c in Chlorosomes from the bchQ Mutant of Chlorobaculum tepidum

In contrast to the common viewpoint that bacteriochlorophyll (BChl) motion is largely absent within the chlorosome assembly, physics-based modeling points to a crucial role of the nanoscale librational motion of the macrocycle for the transfer of excitons. To elucidate this motion experimentally, compositional uniformity and high sensitivity are required. We focused on uniformly 13 C labeled chlorosome preparations from the bchQ mutant Chlorobaculum tepidum with significantly enhanced structural homogeneity. The librational motion is characterized using Rotational Echo DOuble Resonance (REDOR), and in addition, the impact of temperature on specific functionalities within BChl molecules is studied with 1-dimensional and 2-dimensional dipolar and scalar-based MAS NMR measurements. Results show the gradual freezing of the tails and side chains of the BChls with decreasing temperature. However, the librational motion analyzed by measuring the 5C–H dipolar coupling strength obtained from REDOR data sets persists at different temperatures. REDOR simulations show a close match to the experimental dephasing frequency of oscillation for a dipolar coupling strength of 17.5 ± 0.5 kHz which is considerably less than the dipolar coupling strength of 22.7 kHz in the rigid limit. Following a two-site jump model, we arrive at an estimate for BChl libration sampling at an angle of θ = 48 ± 4°, corroborating that the macrocycle indeed experiences significant librational motion on a time scale that is short compared to the NMR measurement time. This finding is in full quantitative support of the dominant rotational motion exhibited by the BChl macrocycle estimated from early MD simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Search for Pulsars around Sgr A* in the First Event Horizon Telescope Data Set

In 2017 the Event Horizon Telescope (EHT) observed the supermassive black hole at the center of the Milky Way, Sagittarius A* (Sgr A*), at a frequency of 228.1 GHz (λ = 1.3 mm). The fundamental physics tests that even a single pulsar orbiting Sgr A* would enable motivate searching for pulsars in EHT data sets. The high observing frequency means that pulsars—which typically exhibit steep emission spectra—are expected to be very faint. However, it also negates pulse scattering, an effect that could hinder pulsar detections in the Galactic center. Additionally, magnetars or a secondary inverse Compton emission could be stronger at millimeter wavelengths than at lower frequencies. We present a search for pulsars close to Sgr A* using the data from the three most sensitive stations in the EHT 2017 campaign: the Atacama Large Millimeter/submillimeter Array, the Large Millimeter Telescope, and the IRAM 30 m Telescope. We apply three detection methods based on Fourier-domain analysis, the fast folding algorithm, and single-pulse searches targeting both pulsars and burst-like transient emission. We use the simultaneity of the observations to confirm potential candidates. No new pulsars or significant bursts were found. Being the first pulsar search ever carried out at such high radio frequencies, we detail our analysis methods and give a detailed estimation of the sensitivity of the search. We conclude that the EHT 2017 observations are only sensitive to a small fraction (≲2.2%) of the pulsars that may exist close to Sgr A*, motivating further searches for fainter pulsars in the region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimate of background baseline and upper limit on the chiral magnetic effect in isobar collisions at $\sqrt{S_{NN}}$=200 GeV at the BNL Relativistic Heavy Ion Collider

For the search of the chiral magnetic effect (CME), STAR previously presented the results from isobar collisions ($^{96}_{44}$Ru + $^{96}_{44}$Ru, $^{96}_{40}$Zr + $^{96}_{40}$Zr) obtained through a blind analysis. The ratio of results in Ru+Ru to Zr+Zr collisions for the CME-sensitive charge-dependent azimuthal correlator (Δ⁢𝛾), normalized by elliptic anisotropy (𝑣2), was observed to be close to but systematically larger than the inverse multiplicity ratio. The background baseline for the isobar ratio, 𝑌= (Δ⁢𝛾/𝑣2) Ru /(Δ⁢𝛾/𝑣2) Zr , is naively expected to be (1/𝑁) Ru /(1/𝑁) Zr ; however, genuine two- and three-particle correlations are expected to alter it. We estimate the contributions to 𝑌 from those correlations, utilizing both the isobar data and hijing simulations. After including those contributions, we arrive at a final background baseline for 𝑌, which is consistent with the isobar data. Here, we extract an upper limit for the CME fraction in the Δ⁢𝛾 measurement of approximately 10% at a 95% confidence level on in isobar collisions at $\sqrt{S_{NN}}$=200 GeV, with an expected 15% difference in their squared magnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upper limit on the chiral magnetic effect in isobar collisions at the Relativistic Heavy-Ion Collider

The chiral magnetic effect (CME) is a phenomenon that arises from the QCD anomaly in the presence of an external magnetic field. The experimental search for its evidence has been one of the key goals of the physics program of the Relativistic Heavy-Ion Collider. The STAR Collaboration has previously presented the results of a blind analysis of isobar collisions ( Ru 44 96 + Ru 44 96 , Zr 40 96 + Zr 40 96 ) in the search for the CME. The isobar ratio ( Y ) of CME-sensitive observable, charge separation scaled by elliptic anisotropy, is close to but systematically larger than the inverse multiplicity ratio, the naive background baseline. This indicates the potential existence of a CME signal and the presence of remaining nonflow background due to two- and three-particle correlations, which are different between the isobars. In this postblind analysis, we estimate the contributions from those nonflow correlations as a background baseline to Y , utilizing the isobar data as well as Heavy Ion Jet Interaction Generator simulations. This baseline is found consistent with the isobar ratio measurement, and an upper limit of 10% at 95% confidence level is extracted for the CME fraction in the charge separation measurement in isobar collisions at s NN = 200 GeV. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dose Rate Analysis of the WCS Consolidated Interim Storage Facility

This report describes a confirmatory calculation for a proposed consolidated interim storage facility (CISF) to support the US Nuclear Regulatory Commission’s review of the license application submitted by the Interim Storage Partners. The scope of this report is limited to an assessment of the annual dose from direct radiation associated with Phase 1 of the Waste Control Specialists (WCS) CISF and the determination of the minimum controlled area boundary based on the 10 CFR 72.104 limit of 25 mrem annual dose to the whole body. The confirmatory dose rate calculations used the source term and shielding calculation capabilities of the SCALE 6.2.3 computer code system. The calculation method employed in the confirmatory calculations uses a detailed Monte Carlo radiation transport simulation from source to dose rate. This method differs from the two-step method used in the safety analysis report (SAR), which requires determination of the photon and neutron energy and angular distributions on the cask external surface and then the use of this surface source in a new radiation transport calculation to determine dose rate as a function of distance from the storage facility. A simulation was made using the complete site geometry (all casks present) but with only one cask containing source, and a total of 467 independent calculations were performed to obtain the dose rate maps produced by each storage cask. Basic input data and assumptions used in the SAR (e.g., cask design parameters and design basis assembly characteristics) were used in this confirmatory calculation for consistency with the SAR. Local atmospheric conditions for skyshine calculations were simulated using US standard atmosphere data, which describe average air temperature, pressure, and density as a function of altitude. The determined minimum required distances from the WCS Phase 1 CISF to a contour defined by the 25 mrem annual dose limit were approximately 623 m (0.387 miles) in the N-NE direction, 594 m (0.369 miles) in the SSW direction, and 533 m (0.331 miles) in the E-SE direction and the W-NW direction. The annual dose results of the confirmatory calculation are in relatively good agreement with the annual dose values presented in the WCS SAR. The annual dose produced by the Phase 1 CISF at the nearest site boundary, 0.75 miles away from the CISF, was estimated by this study to be approximately 6.02E-02 ± 2.0E-04 mrem, which is significantly smaller than the 25 mrem annual dose limit provided in 10 CFR 72.104. The SAR annual dose rate value for the nearest site boundary was 7.52E-2 mrem, which included 7.73E-03 mrem due to postulated leakage of the FO-, FC-, and FF-canisters. A comparison with the dose rate values reported in the SAR for 16 detector locations, D1 through D16, on the protected area boundary is also included in this report. This comparison shows that the SAR determined higher annual dose values for detectors D1 through D14 by 12% to 45% and lower annual dose values for detectors D15 and D16 by 18% and 8%, respectively, as compared with this ORNL confirmatory calculation. Sensitivity studies have been performed to support a comprehensive review of the application. In these studies, the effects on dose rate of the modeled air volume, density, and humidity were analyzed. The sensitivity calculations showed that the air volume used in the Monte Carlo simulations was adequate and that a larger air volume would not further increase the dose rate due to skyshine contributions. The sensitivity analysis showed that simulation of local atmospheric conditions is important for the accuracy of dose rate estimates at large distances from the facility. Air humidity was demonstrated to have negligible effects on dose rate values for the simulated local atmospheric conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗